Introduction
Non-sharp-pointed foreign bodies that partially obstruct the esophagus require urgent (< 24 h) endoscopic retrieval. In this briefcase report, we report an alternative method of retrieving an unusual foreign object.
Case report
A 31-year-old female with bipolar disorder presented to our emergency department after the intentional ingestion of a belt buckle. Her only complaint was epigastric pain. A supine abdominal X-ray showed a buckle-shaped, radio-opaque foreign body projecting at the level of the diaphragm (Fig. 1A). Upper endoscopy under general anesthesia and intubation of the patient within 12 h of presentation revealed a partially obstructing belt buckle lodged in the distal esophagus (Fig. 1B). Due to esophageal spasm and difficulty grasping the buckle with the forceps, this was gently advanced into the stomach to allow for a better position to retrieve it from the bar of it to prevent the prong from opening up and causing damage in the stomach and esophageal walls. Neither glucagon nor a latex rubber hood was used. Several attempts at grasping the bar of the buckle failed to ensure an adequate grasp of it, given the slippery surface of the metal. Nevertheless, once an adequate grasp was obtained with the forceps, the belt buckle was slowly retrieved from the esophagus while slowly performing minimal torquing of the endoscope to ensure that the trauma to the esophageal wall was minimal. The object measured 1.25 inches at its largest diameter (Fig. 1C). Reinsertion of the endoscope revealed only minimal erythema and scattered ecchymoses in the esophageal wall, but no mucosal tear or perforation was noted. The patient had no post-procedural complications and was discharged home 2 days after the initial presentation.
Discussion
Non-sharp-pointed foreign bodies that partially obstruct the esophagus require urgent (< 24 h) endoscopic retrieval1. Endoscopic retrieval of foreign bodies wider than 1 inch is preferred as these may be less likely to pass the pylorus1,2. The push technique – whereas the foreign object is advanced into the stomach to facilitate retrieval – has been validated in the management of esophageal food bolus impactions in two large published series3,4. As in this case, with adequate visualization, the same technique may be applied to non-sharp-pointed foreign bodies lodged in the distal esophagus1. It is important to know that optimal evaluation of the foreign object to be retrieved, along with potentially dangerous parts of it (in our case, the prong of the buckle), is essential to allow for a safe and effective retrieval with the least possible damage to the surrounding structures.
Overtubes, latex rubber hoods, and clear caps can be used when faced with sharp-pointed objects to minimize injury to the esophageal and gastric walls2, but these tools have the limitation of not having enough capacity for bigger foreign objects like the one our patient had.
Although in our patient, we did not use glucagon to minimize esophageal peristalsis since this was not prominent, its use has been described in the literature as an aid for allowing esophageal food impactions to pass into the stomach2,5,6. Nevertheless, this has been shown to be effective only in one-third of the patients5 and in the absence of a fixed esophageal obstruction6. Furthermore, it can be used as an aid to decrease peristalsis to achieve better visualization and maneuverability of the endoscope during the extraction of foreign bodies. The use of glucagon should not delay definite endoscopic therapy, and its use is associated in some cases with nausea and emesis which can increase the risk of perforation2.
To the best of our knowledge, this is the first report of successful endoscopic retrieval of a belt buckle impacted in the distal esophagus.
Conclusions
In summary, esophageal foreign bodies are commonly encountered in practice. Optimal visualization and knowledge of the available tools for retrieval, alongside with the limitations of them, are key for successful retrieval and to avoid potential complications.
Specific author contributions
GM López-Portillo, Z Sobani, and SA Sánchez-Luna collected data and wrote the manuscript and revised the manuscript for intellectual content. SA Sánchez-Luna and G Parasher revised the manuscript for intellectual content and endoscopy imaging. SA Sánchez-Luna is the article guarantor. All authors involved in this report approved the final version.