SciELO - Scientific Electronic Library Online

 
vol.13 issue3Hexagonal scale invariant feature transform (H-SIFT) for facial feature extractionReliability optimization of electrical distribution systems using internal loops to minimize energy not-supplied (ENS) author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Journal of applied research and technology

On-line version ISSN 2448-6736Print version ISSN 1665-6423

J. appl. res. technol vol.13 n.3 Ciudad de México Jun. 2015

 

Articles

 

Comparison among some well known control schemes with different tuning methods

 

R. Kumar*, S.K. Singla, V. Chopra

 

Department of Electrical & Instrumentation Engineering, Thapar University, Patiala, Punjab, India. *Corresponding author. E-mail address: rajeev07ei35@gmail.com

 

Abstract

This paper presents a comparison between some well-known control schemes such as feedback, feedback plus feed-forward, cascade and cascade plus feed-forward for controlling a third-order process. The controller applied in various control schemes is a PID controller that has been tuned using Ziegler Nichols (ZN) and relay auto-tuning (RA) methods. The comparative analysis is based upon various performance measures such as rise time (tr), settling time (ts), maximum overshoot (Mp), steady-state error (ess), integral of absolute error (IAE), integral of square error (ISE), integral of time square error (ITSE), and integral of time absolute error (ITAE). Simulation results show that the RA method provides superior performance in case of feedback plus feed-forward and cascade control schemes. On the other hand, the ZN method proves to be better in case of cascade plus feed-forward control scheme.

Keywords: Feedback; Feed-forward; Cascade; PID controller; Ziegler Nichols; Relay auto-tuning.

 

DESCARGAR ARTÍCULO EN FORMATO PDF

 

References

Astrom, K.J., & Hagglund, T. (1995). PID Controllers: Theory, Design and Tuning. USA: Instrument Society of America.         [ Links ]

Bandi, M.A., & Mehta, N.B. (2012). Universal Controller Design Using Arm Controller. International Journal of Engineering Trends and Technology, 3, 74-75.         [ Links ]

Barakat, N., & Rajagopalan, R. (1996). Speed control of a DC motor using a feed-forward computed torque control scheme. Proceedings of the 1996 IEEE international symposium on intelligent control Dearborn (pp. 432-437).         [ Links ]

Bequette, B.Y. (2003). Process control modeling, design and simulation. New Delhi: PHI.         [ Links ]

Brown, R.E., Maliotis, G.N., & Gibby, J.A. (1993). PID self tuning controller for aluminium rolling mill. IEEE Transactions on Industry Applications, 29, 578-583.         [ Links ]

Chopra V., Singla, S.K., & Dewan, L. (2014). Comparative Analysis of Tuning a PID Controller using Intelligent Methods. Acta Polytechnica Hungarica, 11, 235-249.         [ Links ]

Mohammadzaheri, M., & Chen, L. (2009). A design approach for feedback-feedforward control systems (pp. 2266-2271). IEEE International Conference on Control and Automation, Christchurch.         [ Links ]

Ogata, K. (2009). Modern Control Engineering (5th ed.). New Delhi: PHI.         [ Links ]

Peng, C., Zhang, Z., Zou, J., Li, K., & Zhang, J. (2013). Internal model based robust inversion feed-forward and feedback 2 DOF control for LPV system with disturbance. Journal of Process Control, 23, 1415-1425.         [ Links ]

Rice, R., & Cooper, D. (2004). A Rule Based Design methodology for the control of non Self-Regulating Processes. Technical Papers of ISA.         [ Links ]

Song, S., Cai, W., & Wang, Y.G. (2003). Auto-tuning of cascade control systems. ISA Transactions, 42, 63-72.         [ Links ]

Sousa, J.M., & Babuska, R. (1997). Internal model control with a fuzzy model: application to an air-conditioning system. Conference: Fuzzy Systems.         [ Links ] Proceedings of the Sixth IEEE International Conference on Fuzzy Systems, 1, 207-212.         [ Links ]

Tan, W., Liu, J., Chen, T., & Marquez, H.J. (2006). Comparison among some well known PID tuning formulas. Computers & Chemical Engineering, 30, 1416-1423.         [ Links ]

Wang, J., Jing, Y., & Zhang, C. (2008). Robust cascade control system design for central air conditioning system (pp. 1506-1511). Proceedings of 7th World Congress on Intelligent Control and Automation, China.         [ Links ]

Zhang, B.L., Lie, Y.L., Ma, H., & Tang, G.Y. (2014). Discrete feed-forward and feedback optimal tracking control for offshore steel jacket platform. Ocean Engineering, 91, 371-378.         [ Links ]

Zhong, H., Pao, L., & Callafon, R. (2012). Feedforward control for disturbance rejection: Model mismatching and other methods. In: 24th Chinese Control and Decision Conference (CCDC) (pp. 3528 -3533).         [ Links ]

Zhong, Y., & Luo Y. (2011). Comparative study of single loop control and cascade control of third order object. Procedia Engineering, 15, 783-787.         [ Links ]

Zhuang, M., & Atherton, D.P. (1993). Automatic tuning of optimum PID, controllers. IEE Proceedings of Control Theory and Applications, 140, 216-224.         [ Links ]

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License