vol.37 issue1Impact of the “Enhanced Recovery After Surgery” program in knee arthroplasty at the institutional levelFunctional evaluation and quality of life in the follow-up of patients with Charcot arthropathy treated by ankle arthrodesis with a locked retrograde nail author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Acta ortopédica mexicana

Print version ISSN 2306-4102

Abstract

GODOY-MONZON, D et al. Preliminary results of hybrid fixation modular implant in revision knee arthroplasty. Acta ortop. mex [online]. 2023, vol.37, n.1, pp.19-24.  Epub Mar 11, 2024. ISSN 2306-4102.  https://doi.org/10.35366/112809.

Introduction:

revision total knee arthroplasty (TKA) is a challenging procedure that requires proper alignment, restoration of bone loss, and prevention of instability. Modern revision systems offer progressive implant constriction with multiple options for offset, augmentation, and fixation stems.

Objective:

to evaluate the clinical outcomes of a modular implant with hybrid fixation in revision TKA with a minimum follow-up of two years.

Material and methods:

we retrospectively included all revision TKA surgeries performed between September 2018 and September 2019, using the same implant. Patient demographics, comorbidities, and data on bone defects were recorded. Clinical outcomes were assessed using subjective roles and Maudsley scores and the Knee Society Score (KSS). Complications during follow-up were also documented.

Results:

a total of 23 patients were analyzed, comprising 65% females and 35% males, with a median age of 71.1 years. Bone defects following implant removal were classified as F2.T2 in 39.13% of cases, F1.T2 in 8.69%, and F1.T1 in the remaining 52.17%. There were significant improvements in the KSS score (preoperative: 53 points, postoperative: 79 points; p < 0.001). Three (13%) complications were reported, two of which were directly related to the surgery, and two patients required subsequent revision surgery. The 2-year survival rate was 91.3%.

Conclusion:

the use of a modular implant with hybrid fixation in revision TKA demonstrated a high 2-year survival rate, significant improvements in clinical scores, and a low incidence of short-term complications. These findings support the efficacy and safety of this approach, providing favorable clinical outcomes and high patient satisfaction.

Keywords : revision surgery; total knee replacement; modular implants.