SciELO - Scientific Electronic Library Online

 
vol.57 issue4Submicrometric Fibrillar Structures of Codoped Polyaniline Obtained by Co-oxidation Using the NaClO/Ammonium Peroxydisulfate System: Synthesis and CharacterizationChemical Analysis of Coffee Berry Volátiles That Elicit an Antennal Response From the Coffee Berry Borer Hypothenemus hampei author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Journal of the Mexican Chemical Society

Print version ISSN 1870-249X

Abstract

SHAH, Jasmin; RASUL JAN, M.; SHAH, Sultan  and  NAEEM KHAN, M.. Development and Validation of HPLC Method for Simultaneous Determination of Ceftriaxone and Cefaclor in Commercial Formulations and Biological Samples. J. Mex. Chem. Soc [online]. 2013, vol.57, n.4, pp.314-320. ISSN 1870-249X.

Abstract A reversed phase high performance liquid chromatographic method has been developed for the simultaneous determination of cefaclor and ceftriaxone cephalosporin antibiotic. The developed method has been validated and applied to mixtures of the commercial formulation and spiked human plasma. A mediterranea C18 column (4.6 x 250 mm) was used with isocratic solvent delivery system and UV-visible detector. Different experimental parameters like solvent composition (acetonitrile: methanol: triethyl amine buffer 1:1:2 (v/v), flow rate of mobile phase (0.6 mLmin-1), pH of the buffer (7), and wavelength (260 nm) were optimized for effective separation and resolution of the analyte peaks. The separation was achieved in 6 min with retention times of 4.94 ± 0.056 min and 3.39 ± 0.022 min for cefaclor and ceftriaxone respectively. The linear range for both the studied drugs was found to be 0.5-250 μgmL-1 with r2 of 0.9987 (cefaclor) and 0.9997 (ceftriaxone). The limit of detection (3.3 σ/S) was found to be 2.34 × 10-2 μgmL-1 and 1.70 × 10-2 μgmL-1, respectively, for cefaclor and ceftriaxone. Similarly limit of quantification (10σ/S) was 7.10 × 10-2 μgmL-1 for cefaclor and 5.15 × 10-2 μgmL-1 for ceftriaxone. The chromatographic procedure was applied to commercial formulations and spiked human plasma and the results were compared with literature HPLC method.

Keywords : cefaclor; ceftriaxone; simultaneous; HPLC; commercial formulation; spiked human plasma.

        · abstract in Spanish     · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License