SciELO - Scientific Electronic Library Online

 
vol.89 issue3Subclinical cardiac alterations detected by echocardiography in Mexican schoolchildren with overweight and obesityPsychometric evaluation of the Hospital Anxiety and Depression Scale in Mexican adults with ischemic and hypertensive cardiomyopathy author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Archivos de cardiología de México

On-line version ISSN 1665-1731Print version ISSN 1405-9940

Abstract

PEREZ-DIAZ, Pedro et al. Medium-long term mortality and change in functional status in elderly patients with pacemaker. Arch. Cardiol. Méx. [online]. 2019, vol.89, n.3, pp.233-241.  Epub Jan 08, 2021. ISSN 1665-1731.  https://doi.org/10.24875/acm.m19000053.

Background:

Nowadays, 49% of patients with pacemakers are older than 80 years old. Nevertheless, mortality and change in functional status after pacemaker implantation are not well documented in elderly patients.

Objective:

We designed a prospective study to analyze cardiovascular mortality and change in functional status of elderly patients, medium-long term after pacemaker implantation.

Methods:

Observational study including pacemaker implants in individual older than 70 years old in a single center university hospital between 2012 and 2014. Analysis testing for an association between pacemaker system, medium-long term mortality and functional status after implantation were undertaken.

Results:

60% of patients were older than 80 years old. Third-degree atrio-ventricular block (44.3%) and slow ventricular response atrial fibrillation (16.7%) were the most frequent electrocardiogram abnormalities, while bicameral DDD was the sort of pacing our department used the most (38.6%) (VVI in octogenarian patients, 38.7%). Long-term mortality was significantly higher in ventricular devices, especially in octogenarian patients (p = 0.001 respectively). Single-chamber VVI pacing acted as independent predictors of all-cause mortality in these individuals (p = 0.001). We found no significant improvement in Barthel index and functional status in this subgroup of patients, 3 years after pacing.

Conclusion:

Long-term mortality in individuals older than 80 years old with pacemaker implantation, was significantly higher comparing with general population, especially in ventricular devices. No significant improvement in functional status was detected in this subgroup of patients.

Keywords : Pacemaker; Octogenarian; Third-degree atrio-ventricular block; Functional status; Mortality; Spain.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )