SciELO - Scientific Electronic Library Online

 
vol.85 issue3Cardiorenal syndrome type 1 in the intensive coronary care unit of the Hospital Nacional Arzobispo LoayzaIn-hospital mortality risk factors for patients with cerebral vascular events in infectious endocarditis: A correlative study of clinical, echocardiographic, microbiologic and neuroimaging findings author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Archivos de cardiología de México

On-line version ISSN 1665-1731Print version ISSN 1405-9940

Abstract

PARRA-BRAVO, José Rafael et al. Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children. Arch. Cardiol. Méx. [online]. 2015, vol.85, n.3, pp.188-194. ISSN 1665-1731.  https://doi.org/10.1016/j.acmx.2014.12.003.

Objective: The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Methods: Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion < 40% was considered abnormal. Results: The device implantation was successful in all patients. Average perfusion of left lung was 44.7 ± 4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. Conclusion: The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device.

Keywords : Patent ductus arteriosus; Percutaneous closure; Amplatzer Duct Occluder; Lung perfusion scan; México.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License