SciELO - Scientific Electronic Library Online

 
vol.79 issue4Psychopathology and personality of patients with heart diseaseSevere myocardial damage caused by leptospirosis. Report of a fatal case in Mexico author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Archivos de cardiología de México

On-line version ISSN 1665-1731Print version ISSN 1405-9940

Abstract

FLORES-OCAMPO, Jorge et al. Clinical predictors of ventricular arrhythmia storms in Chagas cardiomyopathy patients with implantable defibrillators. Arch. Cardiol. Méx. [online]. 2009, vol.79, n.4, pp.263-267. ISSN 1665-1731.

Objectives. To define the predictive factors of electrical storm (ES) in patients with Chronic Chagas Heart Disease (CCh) with an implantable cardioverter defibrillator (ICD). Material and methods. We retrospectively studied 21 consecutive patients with CCh in whom an ICD was implanted between April 2005 and December 2008, with a mean follow up of 867 days. Patients were classified into two groups according to the presence of electrical storm episodes. We compared baseline characteristics, medical treatment and determinants of ventricular function. P values less than 0.05 were considered statistically significant. Results. Of the 21 patients with CCh there were eight women (37%), mean age 61 years and an EF of 30%. It was noted at least one episode of arrhythmic storm in 9 cases (incidence of 43%). The total number of episodes of arrhythmic storm was 13 and the number of ventricular arrhythmias in each episode of arrhythmic storm was 15.6 (range 3-61). A trigger was identified in only two cases (pulmonary infectious process and decompensation of chronic heart failure). After analyzing the possible predictors of arrhythmic storm was found that a greater percentage of subjects with this complication had an EF <35% (89% vs. 50%, p = 0.01) and NYHAfunctional class III (66% vs. 8.3%, p = 0.001). In contrast, a lower percentage of subjects with arrhythmic storm were under beta-blocker treatment (55% vs. 100%, p = 0.01). Conclusions. In subjects with CCh with an ICD, the following variables are predictive of arrhythmic storm: EF <35%, NYHA functional class III-IV and absence of beta-blocker treatment.

Keywords : Chagas disease; Malignant ventricular arrhythmias; Arrhythmic storm; Implantable; Cardioverter Defibrillator; Mexico.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 