SciELO - Scientific Electronic Library Online

 
vol.58 issue2The Effect of NaOH and KOH on the Characterization of Mesoporous AlOOH Nanostructures in the Hydrothermal RouteExploration of Diverse Interactions of Some Vitamins in Aqueous Mixtures of Cysteine author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Journal of the Mexican Chemical Society

Print version ISSN 1870-249X

Abstract

CARRILLO-CEDILLO, E. G.; HARO-VAZQUEZ, M. P.; DIAZ TRUJILLO, G. C.  and  CANIZARES-MACIAS, M. P.. Plackett-Burman Factorial Design for the Optimization of a Spectrophotometric Flow Injection Method for Phenol Determination in Tap and Bottled Water Using 4-Aminoantipyrine. J. Mex. Chem. Soc [online]. 2014, vol.58, n.2, pp.99-105. ISSN 1870-249X.

Plackett-Burman and Quarter fraction 25-2 factorial designs were applied to evaluate a spectrophotometric flow injection method in order to determine phenol in water by using 4-aminoantipyrine (4-AAP) as derivatizing reagent. With a minimum number of experiments, the designs enabled the best conditions for phenol analysis: 80 cm and 180 cm reactors; flow-rates being: NH3 1.0 mL min-1; 4-AAP 0.35 mL min-1 and K3[Fe(CN)6] 0.35 mL min-1, [NH3] 0.064 mol L-1, [4-AAP] 9.84 × 10-3 mol L-1, [K3[Fe(CN)6]] 0.02 mol L-1, and an injection volume of 200 µL. With the optimized method it was possible to increase the lineal range from 0.3 µg mL-1 to 30 µg mL-1 and also to quantify the maximum allowable phenol concentration in water in comparison with other standard and flow injection methods whose lineal range are from 0.5 µg mL-1 to 20 µg mL-1 and from 0.5 µg mL-1 to 16 µg mL-1, respectively. The detection limit was of 0.13 µg mL-1 and the regression coefficient was of 0.9999, making possible a throughput of 36 determinations an hour with a minimum consume of reagent. With the proposed method, a distillation step was not necessary to remove sulfates but, when the sulfate:phenol ratio was higher than 83, the analytical signal for phenol increased 8%, but hypochlorite interfered with the signal when the hypochlorite:phenol ratio was higher than 1.

Keywords : Plackett-Burman factorial design; phenol; 4-aminoantipyrine; water; flow injection; spectrophotometry.

        · abstract in Spanish     · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License