SciELO - Scientific Electronic Library Online

 
vol.87 número1Comparación del índice de neutrófilos/linfocitos, la escala de SOFA y la concentración sérica de procalcitonina como indicadores de la gravedad de la apendicitis agudaEsplenectomía laparoscópica, una opción eficaz en un hospital de segundo nivel índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Cirugía y cirujanos

versão On-line ISSN 2444-054Xversão impressa ISSN 0009-7411

Cir. cir. vol.87 no.1 Ciudad de México Jan./Fev. 2019  Epub 29-Nov-2021

https://doi.org/10.24875/ciru.18000315 

Artículos originales

Combination of noise plus weight-bearing accelerates consolidation time in tibial shaft fractures: A preliminary report

La combinación de ruido más carga de peso acelera la consolidación en las fracturas de la diáfisis tibial: Un informe preliminar

Lorenzo Franco-de la Torre1 

José R. Villafán-Bernal2 

Rodrigo Garmendia-Castañón3 

Ana Paola Franco-González1 

Mario A. Isiordia-Espinoza4 

Juan L. Alcalá-Zermeño5 

Eduardo Gómez-Sánchez6 

Luis M. Rodríguez-Méndez6 

Sergio Sánchez-Enríquez4  5  * 

1Departamento de Ciencias de la Salud, División de Ciencias Biomédicas, Centro Universitario de los Altos, Universidad de Guadalajara. México

2Cátedras CONACYT, Departamento de Cirugía, Universidad Autónoma de Aguascalientes. México

3Ciencia e Innovación para el Desarrollo de Tecnología con Aplicaciones en Biomedicina (CINDETAB). México

4Departamento de Clínicas, División de Ciencias Biomédicas, Centro Universitario de los Altos, Universidad de Guadalajara. México

5Departamento de Biología Molecular y Genómica, Centro Universitario de Ciencias de la Salud, Universidad de Guadalajara, Cuerpo Académico, UDG-CA-533. México

6Servicio de Ortopedia, Hospital Civil de Guadalajara Fray Antonio Alcalde. México


Abstract

Introduction:

Long bones fractures are responsible for prolonged periods of incapacity and economic losses. New therapies for shortening the time of consolidation are needed. Thus, the purpose of this clinical study was to evaluate the efficacy of noise plus weight-bearing over the bone consolidation of tibial shaft fractures.

Methods:

In this clinical trial, 12 patients with tibial shaft fractures were recruited during a 24-month period. Participants were treated with intramedullary nails and randomized to two groups: an experimental group and a control group. Both groups underwent a rehabilitation program consisting of two daily walking sessions with progressive weight-bearing. Simultaneously, the experimental group received a noise stimulus on the fracture site with intensities of 0.1-0.6 N and frequencies of 0.1-50 Hz. Radiographic consolidation was evaluated by Radiographic Unión Scale of Tibia.

Results:

X-ray consolidation was achieved at 18.6 ± 3.6 weeks and 27.2 ± 6.9 weeks, for experimental and control group, respectively (p < 0.05). Recovery of mobility ranges in the knee and ankle was faster in the experimental group than in the control group.

Conclusions:

This new method to stimulate fracture consolidation has the following advantages: it is effective, portable, easy to use, and inexpensive.

KEY WORDS Tibial fractures; Stochastic resonance; Bone consolidation; Bone healing; Therapy

Resumen

Introducción:

Las fracturas de huesos largos son causa de períodos prolongados de incapacidad y pérdidas económicas. Se necesitan nuevas terapias para acortar el tiempo de consolidación. Por lo tanto, el objetivo de este estudio clínico fue evaluar la eficacia del ruido más el soporte de peso sobre la consolidación ósea de las fracturas de la diáfisis tibial.

Método:

En este ensayo clínico, 12 pacientes con fracturas de la diáfisis tibial fueron reclutados durante un período de 24 meses. Los participantes fueron tratados con clavos intramedulares y luego aleatorizados a dos grupos: un grupo experimental y un grupo control. Ambos grupos se sometieron a un programa de rehabilitación que consta de dos sesiones diarias de caminata con soporte progresivo de peso. Simultáneamente, el grupo experimental recibió un estímulo de ruido en el sitio de la fractura con intensidades de 0.1-0.6 N y frecuencias de 0.1-50 Hz. La consolidación radiográfica se evaluó mediante la escala RUST.

Resultados:

La consolidación radiográfica se logró a las 18.6 ± 3.6 semanas en el grupo experimental y a las 27.2 ± 6.9 semanas en el grupo control (p < 0.05). La recuperación de los rangos de movilidad en la rodilla y el tobillo fue más rápida en el grupo experimental que en el grupo control.

Conclusiones:

Este nuevo método para estimular la consolidación de fracturas tiene las siguientes ventajas: es eficaz, portátil, fácil de usar y económico.

PALABRAS CLAVE Fracturas tibiales; Resonancia estocástica; Consolidación ósea; Curación ósea; Terapia

Introduction

Long bone diaphyseal fractures are responsible for prolonged periods of incapacity, work absenteeism and economical losses that may reach the millions due to their extended recovery period1. To reduce its socioeconomic impact, it is important to investigate methods that accelerate the bone consolidation process. The use of some biophysical methods, such as pulsed electromagnetic fields and low-intensity pulsed ultrasound (LIPU), has become a common therapeutic aid in Europe, Japan, and the United States in the past 20 years2-5. The LIPU is the only method approved by the Food and Drug Administration (FDA) to enhance the recovery process in distal radius fractures, type 1 exposed tibial diaphyseal fractures non-surgically treated as well as for non-union fractures (Approval Number P900009)6. However, the LIPU has not been applied for the bone healing process of tibial shaft fractures treated with an intramedullary nail as it has the drawbacks of implant overheating and high cost7.

Tanaka et al., 2003, accelerated 3.9 times the bone formation by simultaneously adding of noise (0.3 N, 1-50 Hz) to an axial load applied to the ulna which simulated the movement of walking in rats8. Besides, the increase in bone formation was not just the expected result of adding the effects of load and vibration; it was actually potentiated. However, these results were not replicated when noise was used without applying weight load. For this reason, these authors proposed the existence of the stochastic resonance (SR) phenomenon in the bone when applying load and noise simultaneously8. Based on this background, we generate the following hypothesis: the phenomenon of SR can be replicated in humans if we apply a noise stimulus coupled with the weight-bearing that the patient performs during walking to potentiate the osteogenic response.

Materials and methods

Ethical considerations

The present study was approved by the Bioethics and Investigation committees of the Centro Universitario de Ciencias de la Salud of the Universidad de Guadalajara and the Civil Hospital "Fray Antonio Alcalde." All patients signed the written informed consent form before admission to the study, between January 2010 and December 2011.

Study description

In this randomized clinical trial, 12 adult patients (two women and ten men) with recent tibial shaft fractures (< 30 days of evolution) were enrolled during a 24-month period. Participants were treated with closed and blocked intramedullary nails and randomized to two groups using sealed and consecutively numbered opaque envelopes: an experimental group (n = 6, weight-bearing plus noise stimulus) and a control group (n = 6, weight-bearing only). After removal of stitches, the patients underwent a rehabilitation program (RP) in two daily sessions of 20 min each. The RP was an outpatient period in which the participants walked using crutches or a walker and partial weight-bearing (15% of its own weight the 1st month) for 20 min (10 min of walking, followed by 5 min of rest and other 10 min of walking). The weight-bearing was duplicated in the 2nd month, and full weight-bearing was recommended in the 3rd month after the removal of the stitches. Simultaneously to the RP, the experimental group received a noise stimulus on the cutaneous surface of the fracture site with random intensities of 0.1-0.6 N and random frequencies of 0.1-50 Hz. The actors were placed directly on the surface of the skin just over the fracture site and turned it on during ambulation of the patient. Radiographic consolidation was evaluated by Radiographic Unión Scale of Tibia9. Patients with a diagnosis of diabetes mellitus, malnutrition, intestinal malabsorption, hepatic and/or renal insufficiency, nephrotic syndrome or any immunodeficiency, as well as patients who were receiving pharmacological therapy that could alter bone metabolism such as thiazolidinediones, bisphosphonates, calcium, and among other drugs, were excluded. In addition, patients with dementia or any disability that rendered them incapable of following orders, pregnant women or polyfractured patients were also excluded.

Devices description

Our working team designed the device used for the stimulus application which consists of two parts: a controller and a actor. The controller defines the vibratory wave's amplitude and force and the actor consists of two magnetic motors coupled permanently to an electric current to convert the energy into a mechanical signal. The device's intensity range and frequency were 0.1 a 0.6 N and 0.1-50 Hz, respectively. The device was programmed for randomly changing the intensity and frequency each 100 ms within the previously mentioned range.

Statistical analysis

The statistical analysis was carried out with IBM SPSS Statistics v. 17 (Armonk, NY, USA). All data were expressed as means ± standard deviations. The categorical variables were compared using Fisher's exact test. The numerical variables were assessed with Mann-Whitney U-test. The level of statistical significance was set at p < 0.05.

Results

Demographic variables

Demographic and surgical characteristics were similar for both experimental and control groups. Any variables showed no statistical difference (Table 1; p > 0.05).

Table 1 Demographic and surgical variables. 

Variable Experimental group Control group p value
Age (mean±SD) 23.2 ± 5.0 26.5 ± 8.5 1
Gender (male:female) 5:1 5:1 1
Weight (mean±SD) 61.8 ± 9.6 65.9 ± 13.6 0.63
Injury mechanism (direct/indirect) 3:3 4:2 1
Affected leg (right to left) 5:1 4:2 0.87
Concomitant ipsilateral fibula fracture 5 6 0.60
Tibial fractures (Open: closed) 3:3 2:4 0.89
Closed and blocked intramedullary nailing 6 6 1

Radiographical consolidation

The required time for reach radiographical consolidation was better in the experimental group when compared to control group (p = 0.02). The progress of radiographical consolidation is shown in figure 1.

Figure 1 Radiographic progression of bone consolidation (Mann-Whitney U-test, *p < 0.05). 

Functional recovery

The recovery of mobility ranges in both knee and ankle was faster in the experimental group than in the control group after 12 post-operative weeks (Fig. 2).

Figure 2 Percentage of patients in each group that reach complete range of motion of both knee and ankle at 12 weeks (Fisher's exact test, *p < 0.05). 

Complications

There was no need to suspend the use of the experimental device due to discomfort in any of the patients. Few complications were presented among the subjects, which were satisfactorily resolved at the treatment's end. These happened in the experimental group and control group, respectively, as follows: gastrocnemius atrophy, 1 versus 0 patients (p = 0.29); wound dehiscence, 1 versus 0 patients (p = 0.29); hypoesthesia of the affected leg's 5th toe, 0 versus 1 patient (p = 0.29); hallux neurapraxia 0 versus 1 patient (p = 0.29), and delayed consolidation 0 versus 2 patients (p = 0.12). Consolidation delay was considered when recovery did not occur before the 26th week after surgery10.

Discussion

The present work assessed for 1st time the effect of applying simultaneous axial weight-bearing and noise vibration to accelerate the consolidation of tibial shaft fractures. Both groups were similar in demographic and anthropometric variables as well as in the trauma basic characteristics: lesion mechanism, affected leg, concomitant fibula fracture, and open fracture percentage.

The usual reported time for the clinical consolidation of tibial shaft fracture treated with closed and blocked intramedullary nail ranges from 16 to 30 weeks (112-210 days)11-14, and it depends on several factors such as age, severity of injury, fixation rigidity, and nutritional status15-17.

In the current study, the consolidation process in the control group lasted approximately 27 weeks (190 days), and two patients showed consolidation delay. This consolidation time is within the time range reported by other studies11-14. However, the frequency of consolidation delay in our study is higher than the one reported by Chalidis et al. 200913. The experimental group achieved consolidation almost 9 weeks earlier (60 days in total) and no patient was delayed in consolidation. Taking this into account, we can suggest that applying simultaneous noise vibration and weight-bearing accelerated the bone recovery process in adults with tibial shaft fracture managed with closed and blocked intramedullary nail. Although direct precedent of similar human therapies such as the one herein presented does not exist, Tanaka et al., 2003, demonstrated an important increase in bone formation in vivo when in healthy mice without ulna fracture, simultaneous axial load and noise vibration were applied. The increase in bone formation obtained was 4-fold as expected for the sole adding of load and vibration, suggesting that a SR phenomenon could occur when noise and load were applied at the same time8.

Previous studies using any physical method have demonstrated positive effects on bone consolidation6,18,19. Rubin et al., 2001, reported the use of LIPU to accelerate the healing of fractures which one was approved for the FDA in October 1994. Likewise, this method was approved for the FDA for treatment of established non-unions in February 20006. However, such results have been controversial20,21 and the need to research therapeutic alternatives to accelerate the consolidation of fractures persists.

This work represents an approximation to a new method to accelerate the bone consolidation process of lower extremity fractures. Furthermore, this method is promising for improving joint mobility, decreasing the frequency of delay in consolidation and does not produce any discomfort that obligates its discontinuation.

Conclusion

The combination of vibrational noise plus weight-bearing (ambulation) decreased the time of consolidation in tibial shaft fractures in an effective, easy, affordable, and accessible way. In addition, it might be a good method to diminish the frequency of consolidation delays.

Acknowledgments

To authorities of the Hospital Civil Fray Antonio Alcalde and the Departments of Radiology and Orthopeadics by the facilities given to this research.

References

1. Mathew G, Hanson BP. Global burden of trauma:need for effective fracture therapies. Indian J Orthop. 2009;43:111-6. [ Links ]

2. Lin HY, Lu KH. Repairing large bone fractures with low frequency electromagnetic fields. J Orthop Res. 2010;28:265-70. [ Links ]

3. Satter Syed A, Islam MS, Rabbani KS, Talukder MS. Pulsed electromagnetic fields for the treatment of bone fractures. Bangladesh Med Res Counc Bull. 1999;25:6-10. [ Links ]

4. Gupta TD, Jain VK, Tandon PN. Comparative study of bone growth by pulsed electromagnetic fields. Med Biol Eng Comput. 1991;29:113-20. [ Links ]

5. Tsai CL, Chang WH, Liu TK, Song GM. Ultrasound can affect bone healing both locally and systemically. Chin J Physiol. 1991;34:213-22. [ Links ]

6. Rubin C, Bolander M, Ryaby JP, Hadjiargyrou M. The use of low-intensity ultrasound to accelerate the healing of fractures. J Bone Joint Surg Am. 2001;83-A:259-70. [ Links ]

7. Schortinghuis J, Stegenga B, Raghoebar GM, de Bont LG. Ultrasound stimulation of maxillofacial bone healing. Crit Rev Oral Biol Med. 2003;14:63-74. [ Links ]

8. Tanaka SM, Alam IM, Turner CH. Stochastic resonance in osteogenic response to mechanical loading. FASEB J. 2003;17:313-4. [ Links ]

9. Whelan DB, Bhandari M, Stephen D, et al. Development of the radiographic union score for tibial fractures for the assessment of tibial fracture healing after intramedullary fixation. J Trauma. 2010;68:629-32. [ Links ]

10. Alemdaroğlu KB, Tiftikçi U, Iltar S, et al. Factors affecting the fracture healing in treatment of tibial shaft fractures with circular external fixator. Injury. 2009;40:1151-6. [ Links ]

11. Bonnevialle P, Belumore Y, Foucras L, Hezard L, Mansat M. Tibial fracture with intact fibula treated by reamed nailing. Rev Chir Orthop Reparatrice Appar Mot. 2000;86:29-37. [ Links ]

12. Larsen LB, Madsen JE, Høiness PR, Øvre S. Should insertion of intramedullary nails for tibial fractures is with or without reaming?A prospective, randomized study with 3.8 years'follow-up. J Orthop Trauma. 2004;18:144-9. [ Links ]

13. Chalidis BE, Petsatodis GE, Sachinis NC, Dimitriou CG, Christodoulou AG. Reamed interlocking intramedullary nailing for the treatment of tibial diaphyseal fractures and aseptic nonunions. Can we expect an optimum result?. Strategies Trauma Limb Reconstr. 2009;4:89-94. [ Links ]

14. Kamruzzaman A, Islam S. Result of closed interlocking intramedullary nail in tibial shaft fracture. Bang Med J (Khulna). 2011;44:15-7. [ Links ]

15. Augat P, Simon U, Liedert A, Claes L. Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone. Osteoporos Int. 2005;16 Suppl 2:S36-43. [ Links ]

16. Claes LE, Heigele CA, Neidlinger-Wilke C, et al. Effects of mechanical factors on the fracture healing process. Clin Orthop Relat Res. 1998;355:S132-47. [ Links ]

17. Smith-Adaline EA, Volkman SK, Ignelzi MA Jr., et al. Mechanical environment alters tissue formation patterns during fracture repair. J Orthop Res. 2004;22:1079-85. [ Links ]

18. Heckman JD, Ryaby JP, McCabe J, Frey JJ, Kilcoyne RF. Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound. J Bone Joint Surg Am. 1994;76:26-34. [ Links ]

19. Mammi GI, Rocchi R, Cadossi R, Massari L, Traina GC. The electrical stimulation of tibial osteotomies. Double-blind study. Clin Orthop Relat Res. 1993;288:246-53. [ Links ]

20. Emami A, Petrén-Mallmin M, Larsson S. No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures. J Orthop Trauma. 1999;13:252-7. [ Links ]

21. Starr AJ, Borer DS, Reinert CM. Conflict of interest, bias, and objectivity in research articles. J Bone Joint Surg Am. 2001;83-A:1429-31. [ Links ]

Received: March 25, 2018; Accepted: September 01, 2018

*Correspondence: Sergio Sánchez-Enríquez Carretera a Yahualica, km 7.5 C.P. 47600, Tepatitlán de Morelos, Jal., México E-mail: sergio.enriquez@cualtos.udg.mx

Conflicts of interest

The authors declare that they have no conflicts of interest concerning this article.

Creative Commons License Instituto Nacional de Cardiología Ignacio Chávez. Published by Permanyer. This is an open access article under the CC BY-NC-ND license