<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-7203</journal-id>
<journal-title><![CDATA[Acta médica Grupo Ángeles]]></journal-title>
<abbrev-journal-title><![CDATA[Acta méd. Grupo Ángeles]]></abbrev-journal-title>
<issn>1870-7203</issn>
<publisher>
<publisher-name><![CDATA[Grupo Ángeles, Servicios de Salud]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-72032025000300258</article-id>
<article-id pub-id-type="doi">10.35366/119953</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Daño condral durante la inserción de tornillos intramedulares en la fijación de fracturas de falange proximal: un modelo cadavérico que compara diferentes métodos]]></article-title>
<article-title xml:lang="en"><![CDATA[Chondral damage during intramedullary screw insertion in proximal phalangeal fracture fixation: a cadaveric model comparing different constructs]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ortega López]]></surname>
<given-names><![CDATA[Uriel Alexander]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
<xref ref-type="aff" rid="Aaf"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sánchez de la Barquera]]></surname>
<given-names><![CDATA[George Benjamín Edgar]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Robert Hausmann]]></surname>
<given-names><![CDATA[Michael]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Ricardo]]></surname>
<given-names><![CDATA[María Cristina]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vergara]]></surname>
<given-names><![CDATA[Daniela]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[León Soto]]></surname>
<given-names><![CDATA[Humberto]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bergua]]></surname>
<given-names><![CDATA[Antonio]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad La Salle México Facultad Mexicana de Medicina ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Hospital Angeles Universidad  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>México</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Mount Sinai Hospital NYC  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>USA</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Hospital Serena del Mar Colombia  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="Af5">
<institution><![CDATA[,Pontificia Universidad Católica de Chile  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Chile</country>
</aff>
<aff id="Af6">
<institution><![CDATA[,Universidad Iberoamericana  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af7">
<institution><![CDATA[,Trimed Mexico  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2025</year>
</pub-date>
<volume>23</volume>
<numero>3</numero>
<fpage>258</fpage>
<lpage>264</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-72032025000300258&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-72032025000300258&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-72032025000300258&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen:  Introducción:  Las fracturas de falange (FP) son las segundas fracturas más comunes en el miembro superior después de las fracturas de radio distal (DRF). La fijación intramedular de las fracturas de las falanges proximales es actualmente muy atractiva. Sin embargo, el daño condral sigue siendo motivo de preocupación; el objetivo de este estudio es medir el defecto condral después de la fijación intramedular con diferentes técnicas y tornillos.  Material y métodos:  Se realizó un estudio transversal, experimental y analítico, incluyendo nueve cadáveres. Se fracturó la falange proximal desde el dedo índice hasta el meñique de ambas manos, se colocaron en total 96 tornillos combinando con diferentes técnicas, se utilizaron tornillos de 2.4 y 1.8 mm.  Resultados:  Tornillos de mayor diámetro causaron mayor daño condral, 6.84 vs 11.96% con los tornillos de 1.8 y 2.4 mm respectivamente. La técnica transarticular causa mayor daño condral en comparación con la técnica intraarticular, ya sea con la colocación de un solo tornillo (p = 0.00) o de ambos tornillos (p = 0.0018).  Conclusiones:  La colocación de tornillos intramedulares mediante la técnica intraarticular parece producir menos daño condral. El daño se puede minimizar utilizando la técnica de &#8220;palanca y lugar&#8221; descrita en nuestro artículo.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract:  Introduction:  Phalanx fractures (FP) are the second most common fractures in the upper limb after distal radius fractures (DRF). Intramedullary fixation of proximal phalangeal fractures is currently very attractive. However, chondral Damage remains a concern; The objective of this study is to measure the chondral defect after intramedullary fixation with different techniques and screws.  Material and methods:  A cross-sectional, experimental, and analytical study was carried out, including nine corpses. The proximal phalanx was fractured from the index finger to the little finger of both hands; a total of 96 screws were placed, combining different techniques, and 2.4 mm and 1.8 mm screws were used.  Results:  Larger diameter screws caused more significant chondral Damage, 6.84 vs 11.96% with 1.8 and 2.4 mm screws, respectively. The trans-articular technique causes more significant chondral Damage compared to the intra-articular technique, whether with the placement of a single screw (p = 0.00) or both screws (p = 0.0018).  Conclusions:  The placement of intramedullary screws using the intra-articular technique seems to produce less chondral Damage. Damage can be minimized using the &#8220;lever and place&#8221; technique described in our article.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[falange]]></kwd>
<kwd lng="es"><![CDATA[fractura]]></kwd>
<kwd lng="es"><![CDATA[traumatología]]></kwd>
<kwd lng="es"><![CDATA[cirugía]]></kwd>
<kwd lng="es"><![CDATA[tornillo]]></kwd>
<kwd lng="en"><![CDATA[phalanx]]></kwd>
<kwd lng="en"><![CDATA[fracture]]></kwd>
<kwd lng="en"><![CDATA[traumatology]]></kwd>
<kwd lng="en"><![CDATA[surgery]]></kwd>
<kwd lng="en"><![CDATA[screw]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karl]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
<name>
<surname><![CDATA[Olson]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenwasser]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The epidemiology of upper extremity fractures in the United States, 2009]]></article-title>
<source><![CDATA[J Orthop Trauma]]></source>
<year>2015</year>
<volume>29</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>e242-4</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silins]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Turkmen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Vögelin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Haug]]></surname>
<given-names><![CDATA[LCP]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparing treatment of proximal phalangeal fractures with intramedullary screws versus plating]]></article-title>
<source><![CDATA[Arch Orthop Trauma Surg]]></source>
<year>2023</year>
<volume>143</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1699-706</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brei-Thoma]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Vögelin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Franz]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Plate fixation of extra-articular fractures of the proximal phalanx: do new implants cause less problems?]]></article-title>
<source><![CDATA[Arch Orthop Trauma Surg]]></source>
<year>2015</year>
<volume>135</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>439-45</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reid]]></surname>
<given-names><![CDATA[AWN]]></given-names>
</name>
<name>
<surname><![CDATA[Sood]]></surname>
<given-names><![CDATA[MK]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Intramedullary cannulated compression screws for extra-articular phalangeal fractures]]></article-title>
<source><![CDATA[J Hand Surg Asian Pac Vol]]></source>
<year>2021</year>
<volume>26</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>180-7</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ibanez]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Rodrigues]]></surname>
<given-names><![CDATA[FL]]></given-names>
</name>
<name>
<surname><![CDATA[Salviani]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
<name>
<surname><![CDATA[Roberto]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Pengo Junior]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Aita]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Experimental trial on surgical treatment for transverse fractures of the proximal phalanx: technique using intramedullary conical compression screw versus lateral compression plate]]></article-title>
<source><![CDATA[Rev Bras Ortop]]></source>
<year>2015</year>
<volume>50</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>509-14</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rausch]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Harbrecht]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kahmann]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
<name>
<surname><![CDATA[Fenten]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Jovanovic]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hackl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Osteosynthesis of phalangeal fractures: biomechanical comparison of Kirschner wires, plates, and compression screws]]></article-title>
<source><![CDATA[J Hand Surg Am]]></source>
<year>2020</year>
<volume>45</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>987.e1-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sivakumar]]></surname>
<given-names><![CDATA[BS]]></given-names>
</name>
<name>
<surname><![CDATA[An]]></surname>
<given-names><![CDATA[VVG]]></given-names>
</name>
<name>
<surname><![CDATA[Graham]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Ledgard]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Lawson]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Furniss]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Intramedullary compression screw fixation of proximal phalangeal fractures: a systematic literature review]]></article-title>
<source><![CDATA[Hand (NY)]]></source>
<year>2022</year>
<volume>17</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>595-601</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Del Piñal]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Moraleda]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Rúas]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[de Piero]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
<name>
<surname><![CDATA[Cerezal]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws]]></article-title>
<source><![CDATA[J Hand Surg Am]]></source>
<year>2015</year>
<volume>40</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>692-700</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stern]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Commentary on &#8216;Intramedullary headless screw fixation for fractures of the proximal and middle phalanges in the digits of the hand: a review of 31 consecutive fractures&#8217; and &#8216;Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study&#8217;]]></article-title>
<source><![CDATA[J Hand Surg Eur Vol]]></source>
<year>2016</year>
<volume>41</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>695</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gaspar]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
<name>
<surname><![CDATA[Gandhi]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Culp]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[Kane]]></surname>
<given-names><![CDATA[PM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Dual antegrade intramedullary headless screw fixation for treatment of unstable proximal phalanx fractures]]></article-title>
<source><![CDATA[Hand (N Y)]]></source>
<year>2019</year>
<volume>14</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>494-9</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borbas]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dreu]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Poggetti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Calcagni]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Giesen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study]]></article-title>
<source><![CDATA[J Hand Surg Eur Vol]]></source>
<year>2016</year>
<volume>41</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>683-7</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lögters]]></surname>
<given-names><![CDATA[TT]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[HH]]></given-names>
</name>
<name>
<surname><![CDATA[Gehrmann]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Windolf]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kaufmann]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Proximal phalanx fracture management]]></article-title>
<source><![CDATA[Hand (N Y)]]></source>
<year>2018</year>
<volume>13</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>376-83</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>