<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402023000100022</article-id>
<article-id pub-id-type="doi">10.24875/acm.210003071</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Estimulación temporal mediante cable de fijación activa]]></article-title>
<article-title xml:lang="en"><![CDATA[Temporal stimulation by active fixation lead]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Yáñez-Guerrero]]></surname>
<given-names><![CDATA[A. Paola]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Neach]]></surname>
<given-names><![CDATA[Diego]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[León-Romero]]></surname>
<given-names><![CDATA[Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[Santiago]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Instituto Nacional de Cardiología Ignacio Chávez Servicio de Electrofisiología ]]></institution>
<addr-line><![CDATA[Ciudad de México ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2023</year>
</pub-date>
<volume>93</volume>
<numero>1</numero>
<fpage>22</fpage>
<lpage>25</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402023000100022&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402023000100022&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402023000100022&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen  Objetivo: Determinar seguridad y eficacia del marcapasos temporal mediante cable de fijación activa vía yugular y/o subclavia.  Métodos: Se analizaron pacientes desde 2017 a 2021 postextracción de marcapasos dependientes de estimulación.  Resultados: Se colocó estimulación temporal en 25 pacientes con una edad media de 68 ± 16 años. La media de duración de la estimulación temporal fue cinco días. No se registró mortalidad asociada a la estimulación temporal, sin embargo en un paciente se presentó desplazamiento de cable y falla de captura a los cuatro días de la colocación.  Conclusiones: La estimulación temporal mediante cable de fijación activa es segura y eficaz.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract  Objective: To determine the efficacy and safety of temporary pacing with an active fixation lead placed trough the internal jugular vein and/or subclavian vein.  Methods: We analyzed a consecutive series of 25 out of 73 patients that had a pacemaker extraction and were pacing dependent requiring temporary pacing with an active fixation lead until the new pacemaker implant, from 2017 to 2021.  Results: After extraction 25 patients age 68 years ±16 years, required temporary pacing, the media for temporary pacing was 5 days. There were no mortality associated to temporary stimulation. Only one patient (4%) had a complication 4 days after the implant with capture fail due to a microdislogement requiring reintervention.  Conclusion: Temporary stimulation through active fixation pacemaker lead it is safe and effective.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Marcapasos]]></kwd>
<kwd lng="es"><![CDATA[Estimulación cardiaca]]></kwd>
<kwd lng="es"><![CDATA[Estimulación temporal]]></kwd>
<kwd lng="en"><![CDATA[Pacemaker]]></kwd>
<kwd lng="en"><![CDATA[Cardiac pacing]]></kwd>
<kwd lng="en"><![CDATA[Temporary pacing]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kusumoto]]></surname>
<given-names><![CDATA[FM]]></given-names>
</name>
<name>
<surname><![CDATA[Schoenfeld]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Wilkoff]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Berul]]></surname>
<given-names><![CDATA[CI]]></given-names>
</name>
<name>
<surname><![CDATA[Birgersdotter-Green]]></surname>
<given-names><![CDATA[UM]]></given-names>
</name>
<name>
<surname><![CDATA[Carrillo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction]]></article-title>
<source><![CDATA[Hear Rhythm]]></source>
<year>2017</year>
<volume>14</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>e503-51</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cipriano]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Subzposh]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[McCaffrey]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Koman]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Fridman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Outcomes of standard permanent active fixation leads for temporary pacing]]></article-title>
<source><![CDATA[JACC Clin Electrophysiol]]></source>
<year>2020</year>
<volume>6</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>304-10</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[NH]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Elsayed]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[O'Callaghan]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Leong]]></surname>
<given-names><![CDATA[FT]]></given-names>
</name>
<name>
<surname><![CDATA[Yousef]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The indications and safety of prolonged temporary pacing using active-fixation leads and externalized pulse generator]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2021</year>
<volume>44</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>506-12</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muñoz Bono]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto Palomino]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Macías Guarasa]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández Sierra]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Jiménez Pérez]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Curiel Balsera]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Eficacia y seguridad de la implantación de marcapasos transvenosos transitorios en una unidad de cuidados intensivos]]></article-title>
<source><![CDATA[Med Intensiva]]></source>
<year>2011</year>
<volume>35</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>410-6</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Braun]]></surname>
<given-names><![CDATA[MU]]></given-names>
</name>
<name>
<surname><![CDATA[Rauwolf]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Bock]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kappert]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Boscheri]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Schnabel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Percutaneous lead implantation connected to an external device in stimulation-dependent patients with systemic infection - A prospective and controlled study]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2006</year>
<volume>29</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>875-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grande-Trillo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Esteve-Ruiz]]></surname>
<given-names><![CDATA[IM]]></given-names>
</name>
<name>
<surname><![CDATA[Matabuena-Gómez-Limón]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Arana-Rueda]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Uso actual y complicaciones del marcapasos transitorio endocavitario urgente en un centro de tercer nivel]]></article-title>
<source><![CDATA[Cardiocore]]></source>
<year>2017</year>
<volume>52</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>11-5</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Keituqwa Yáñez]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Navarro Martínez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[García Valiente]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez González]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[Nicolás Franco]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Outcomes of temporary pacing via transfemoral externalize active fixation leads]]></article-title>
<source><![CDATA[Med Intensiva (Engl Ed)]]></source>
<year>2022</year>
<volume>46</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>96-8</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morales]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Márquez]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Idiopathic Lead Migration:Concept and Variants of an Uncommon Cause of Cardiac Implantable Electronic Device]]></article-title>
<source><![CDATA[Am Coll Cardiol EP]]></source>
<year>2017</year>
<volume>3</volume>
<page-range>1321-9</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
