<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-0099</journal-id>
<journal-title><![CDATA[Cirujano general]]></journal-title>
<abbrev-journal-title><![CDATA[Cir. gen]]></abbrev-journal-title>
<issn>1405-0099</issn>
<publisher>
<publisher-name><![CDATA[Asociación Mexicana de Cirugía General A.C.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-00992014000400205</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Eficacia de una malla composite de silicona para disminuir las adherencias intraabdominales en ratas Wistar. Resultados preliminares]]></article-title>
<article-title xml:lang="en"><![CDATA[Efficacy of a silicone composite mesh to reduce intra-abdominal adhesions in Wistar rats: A preliminary report]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Marentes Etienne]]></surname>
<given-names><![CDATA[José Jorge]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Joya Cervera]]></surname>
<given-names><![CDATA[Raúl Edgardo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Hernández]]></surname>
<given-names><![CDATA[Alejandrina]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Prieto-Díaz-Chávez]]></surname>
<given-names><![CDATA[Emilio]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad de Colima Facultad de Medicina ]]></institution>
<addr-line><![CDATA[ Colima]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,SSA Hospital Regional Departamento de Medicina Interna]]></institution>
<addr-line><![CDATA[ Colima]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2014</year>
</pub-date>
<volume>36</volume>
<numero>4</numero>
<fpage>205</fpage>
<lpage>208</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-00992014000400205&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-00992014000400205&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-00992014000400205&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen Introducción: Las adherencias intraabdominales de una prótesis o malla pueden ocurrir en el 80-90% de los pacientes y pueden tener serias consecuencias. La silicona es un material que se ha descrito para el cierre temporal del abdomen y la reparación de defectos ventrales. Las mallas composite con silicona no se han descrito para prevenir esta complicación. El objetivo de este estudio fue comparar la efi cacia de una malla composite de polipropileno con silicona para prevenir la presencia de adherencias abdominales en un modelo de hernia ventral inducida en ratas Wistar. Material y métodos: Se compararon dos grupos de 10 ratas Wistar, cada uno con un defecto herniario abdominal; en el grupo control se realizó la plastia ventral con malla de polipropileno y en el de experimentación, con una malla composite de silicona. Se analizaron las adherencias según las clasifi caciones macroscópica de Diamond y microscópica de Kanbour-Shakir. Resultados: El promedio de adherencias fue del 60% en el grupo experimental, contra el 100% en el grupo control (p = 0.04). Respecto a la gravedad de las adherencias, estas fueron menores en el grupo de experimentación (p = 0.01). Se presentaron fi brosis e infl amación de forma similar en ambos grupos (p &gt; 0.05). La proliferación vascular fue menor en el grupo de experimentación que en el control (p = 0.01). Conclusiones: La malla composite de polipropileno y silicona hasta el momento del corte parece generar menos adherencias que el polipropileno, con menos extensión, disección y gravedad.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Background: Intraabdominal adhesions of a prosthesis or mesh can occur in 80-90% of patients and can have serious consequences. Silicone is a material that has been described for the temporary closure of the abdomen and repair of ventral defects. Silicone composite meshes are not described to prevent this complication. The objective of this study was to compare the effi cacy of a composite mesh of polypropylene with silicone to prevent abdominal adhesions presence of a ventral hernia model induced in Wistar rats. Material and methods: Two groups of 10 Wistar rats, each with an abdominal hernia defect were compared. Ventral hernioplasty was performed in the control group with polypropylene mesh and a composite silicone mesh was used in the experimental group. Adhesions were analyzed according to the macroscopic and microscopic Diamond-Shakir Kanbour ratings. Results: Mean adherence was 60% for the experimental group versus 100% in the control group (p=.04). The severity of these adhesions were lower in the experimental group (p=.01). Fibrosis and infl ammation occurred similarly in both groups (p&gt;.05). Vascular proliferation was lower in the experimental group compared to the controls (p=.01). Conclusions: Composite mesh of polypropylene and silicone, at cut-off so far, appears to generate fewer adhesions than polypropylene with less extension, severity and dissection.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Malla composite]]></kwd>
<kwd lng="es"><![CDATA[Silicona]]></kwd>
<kwd lng="es"><![CDATA[Hernia ventral]]></kwd>
<kwd lng="en"><![CDATA[Composite mesh]]></kwd>
<kwd lng="en"><![CDATA[Silicone]]></kwd>
<kwd lng="en"><![CDATA[Ventral hernia]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shell]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[De la Torre]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Andrades]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Reparación abierta de hernias ventrales incisionales]]></article-title>
<source><![CDATA[Surg Clin N Am]]></source>
<year>2008</year>
<volume>88</volume>
<page-range>61-83</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gaertner]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bonsack]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Delaney]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Visceral adhesions to hernia prostheses]]></article-title>
<source><![CDATA[Hernia]]></source>
<year>2010</year>
<volume>4</volume>
<page-range>375-81</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gaertner]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bonsack]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Delaney]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Visceral adhesions to hernia prostheses]]></article-title>
<source><![CDATA[Hernia]]></source>
<year>2010</year>
<volume>4</volume>
<page-range>375-81</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Emans]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Schreinemacher]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gijbels]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Polypropylene meshes to prevent abdominal herniation. Can stable coatings prevent adhesions in the long term?]]></article-title>
<source><![CDATA[Ann Biomed Engi]]></source>
<year>2009</year>
<volume>37</volume>
<page-range>410-8</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Binnebösel]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Von Trotha]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Lynen Jansen]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Biocompatibility of prosthetic meshes in abdominal surgery]]></article-title>
<source><![CDATA[Semin Immunopathol]]></source>
<year>2011</year>
<volume>33</volume>
<page-range>235-43</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morris-Stiff]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hughes]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The outcomes of nonabsorbable mesh placed within the abdominal cavity: Literature review and clinical experience]]></article-title>
<source><![CDATA[J Am Coll Surg]]></source>
<year>1998</year>
<volume>186</volume>
<page-range>352-67</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orenstein]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Saberski]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kreutzer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative analysis of histopathologic effects of synthetic meshes based on material, weight, and pore size in mice]]></article-title>
<source><![CDATA[J Surg Res]]></source>
<year>2012</year>
<volume>176</volume>
<page-range>423-9</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Felemovicius]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bonsack]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hargerman]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Prevention of adhesions to polypropylene mesh]]></article-title>
<source><![CDATA[J Am Coll Surg]]></source>
<year>2004</year>
<volume>198</volume>
<page-range>543-8</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raptis]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Vichova]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Breza]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A comparison of woven versus nonwoven polypropylene (PP) and expanded versus condensed polytetrafluoroethylene (PTFE) on their intraperitoneal incorporation and adhesion formation]]></article-title>
<source><![CDATA[J Surg Res]]></source>
<year>2011</year>
<volume>169</volume>
<page-range>1-6</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borrazzo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Belmont]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Boffa]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of prosthetic material on adhesion formation after laparoscopic ventral hernia repair in a porcine model]]></article-title>
<source><![CDATA[Hernia]]></source>
<year>2003</year>
<volume>8</volume>
<page-range>108-12</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burger]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Halm]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wijsmuller]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of new prosthetic meshes for ventral hernia repair]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2006</year>
<volume>20</volume>
<page-range>1320-5</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kayaoglu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ozkan]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hazinedaroglu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparison of adhesive properties of five different prosthetic materials used in hernioplasty]]></article-title>
<source><![CDATA[J Invest Surg]]></source>
<year>2005</year>
<volume>18</volume>
<page-range>89-95</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bellón]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[García-Honduvillaodríguez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Pascual]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Composite prostheses for the repair of abdominal wall defects: effect of the structure of the adhesion barrier component]]></article-title>
<source><![CDATA[Hernia]]></source>
<year>2005</year>
<volume>9</volume>
<page-range>338-43</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jenkins]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Yom]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Melman]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair]]></article-title>
<source><![CDATA[Surg Endosc]]></source>
<year>2010</year>
<volume>24</volume>
<page-range>3002-7</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matthews]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Mostafa]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Carbonell]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of adhesion formation and host tissue response to intra-abdominal polytetrafluoroethylene mesh and composite prosthetic mesh]]></article-title>
<source><![CDATA[J Surg Res]]></source>
<year>2005</year>
<volume>123</volume>
<page-range>227-34</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Novitsky]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Harrell]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cristiano]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit]]></article-title>
<source><![CDATA[J Surg Res]]></source>
<year>2007</year>
<volume>140</volume>
<page-range>6-11</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>