<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0035-001X</journal-id>
<journal-title><![CDATA[Revista mexicana de física]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. fis.]]></abbrev-journal-title>
<issn>0035-001X</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Mexicana de Física]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0035-001X2009000200011</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Solenoid coil for mouse-model MRI with a clinical 3-Tesla imager: body imaging]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hidalgo]]></surname>
<given-names><![CDATA[S.S.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Jirak]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Solis]]></surname>
<given-names><![CDATA[S. E.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[A.O.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Robarts Research Institute Imaging Research Laboratories ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Autónoma Metropolitana Centro de Investigación en Instrumentation e Imagenología Medica ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2009</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2009</year>
</pub-date>
<volume>55</volume>
<numero>2</numero>
<fpage>140</fpage>
<lpage>144</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0035-001X2009000200011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0035-001X2009000200011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0035-001X2009000200011&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[A solenoid coil was built for magnetic resonance imaging of the mice. A coil prototype composed of 5 turns, with a length of 4 cm and 2.5 cm radius was developed to acquire (whole) body mouse magnetic resonance images at 130 MHz and an insertable gradient coil set. Coil performance was measured using the Q factor for both the loaded and unloaded cases were 161.67 and 178.03, respectively. These Q factors compare very well with those values reported in the literature. The images were acquired with a clinical 3 T system equipped with a custom-built gradient insert coil and gradient echo image sequence. Both phantom and in vivo images showed good signal-to-noise ratio and uniformity. The electromagnetic interaction between the insertable coils and the solenoidal coil is poor, and no image artefacts are present in the whole-body image of the mouse. This preliminary experience has shown that consistent high quality MR images of the mice can be obtained using this particular hardware configuration, making it a promising method for acquisition of high-spatial resolution MR images of mice. Volume coils are still a good choice when combined with high field MR imagers and standard gradient echo sequences for the magnetic resonance imaging of the mouse.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Una antena del tipo solenoide fue construida para generar imágenes por resonancia magnética de ratones con un sistema de cuerpo entero de 3 T de uso clínico y un arreglo de antenas de gradientes insertable. El prototipo de antena consistió en 5 vueltas con una longitud total de 4 cm y un diámetro de 2.5 cm. El desempeño de la antena se midió usando el factor Q para los casos cargado y sin carga cuyos resultados fueron 161.78 y 178.03 respectivamente. Estos valores concuerdan muy bien con los reportados en la literatura. Se obtuvieron imágenes de un maniquí construido específicamente para este propósito con isletas marcadas con un agente de contraste, usando una secuencia gradiente eco. La interacción electromagnética entre el conjunto de gradientes insertables y la antena solenoide es pobre, y no hay evidencia de artefactos de imagen en las imágenes de cuerpo entero del ratón. Esta experiencia preliminar muestra que esta clase de antena ofrece una alta calidad de imágenes de ratón que es posible obtener con un sistema de 3 T. Las antenas de volumen son una buena elección para obtener imágenes de alta resolución espacial en investigación preclínica de ratones a campos magnéticos altos.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[mouse MRI]]></kwd>
<kwd lng="en"><![CDATA[solenoid coil]]></kwd>
<kwd lng="en"><![CDATA[electromagnetic simulation]]></kwd>
<kwd lng="es"><![CDATA[IRM de ratones]]></kwd>
<kwd lng="es"><![CDATA[antena solenoide]]></kwd>
<kwd lng="es"><![CDATA[simulación electromagnética]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Instrumentaci&oacute;n</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Solenoid coil for mouse&#150;model MRI with a clinical 3&#150;Tesla imager: body imaging</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>S.S. Hidalgo&ordf;<sup>,b,</sup>*, D. Jirak&ordf;, S. E. Solis<sup>b</sup>, and A.O. Rodr&iacute;guez<sup>b</sup></b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i>&ordf; Imaging Research Laboratories, </i><i>Robarts Research Institute, London, ON, N6A 5K8, Canada.</i></font></p>     <p align="justify"><font face="verdana" size="2"><i><sup>b</sup> Centro de Investigaci&oacute;n en Instrumentation e Imagenolog&iacute;a Medica, Universidad Aut&oacute;noma Metropolitana Iztapalapa, M&eacute;xico, D.F., 09340, M&eacute;xico, </i>e&#150;mail: <a href="mailto:shid@xanum.uam.mx">shid@xanum.uam.mx</a><i>*</i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">Recibido el 2 de septiembre de 2008    ]]></body>
<body><![CDATA[<br> Aceptado el 16 de febrero de 2009</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>     <p align="justify"><font face="verdana" size="2">A solenoid coil was built for magnetic resonance imaging of the mice. A coil prototype composed of 5 turns, with a length of 4 cm and 2.5 cm radius was developed to acquire (whole) body mouse magnetic resonance images at 130 MHz and an insertable gradient coil set. Coil performance was measured using the <i>Q </i>factor for both the loaded and unloaded cases were 161.67 and 178.03, respectively. These <i>Q </i>factors compare very well with those values reported in the literature. The images were acquired with a clinical 3 T system equipped with a custom&#150;built gradient insert coil and gradient echo image sequence. Both phantom and in vivo images showed good signal&#150;to&#150;noise ratio and uniformity. The electromagnetic interaction between the insertable coils and the solenoidal coil is poor, and no image artefacts are present in the whole&#150;body image of the mouse. This preliminary experience has shown that consistent high quality MR images of the mice can be obtained using this particular hardware configuration, making it a promising method for acquisition of high&#150;spatial resolution MR images of mice. Volume coils are still a good choice when combined with high field MR imagers and standard gradient echo sequences for the magnetic resonance imaging of the mouse.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Keywords:</b> mouse MRI; solenoid coil; electromagnetic simulation.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     <p align="justify"><font face="verdana" size="2">Una antena del tipo solenoide fue construida para generar im&aacute;genes por resonancia magn&eacute;tica de ratones con un sistema de cuerpo entero de 3&nbsp; T de uso cl&iacute;nico y un arreglo de antenas de gradientes insertable. El prototipo de antena consisti&oacute; en 5 vueltas con una longitud total de 4&nbsp;cm y un di&aacute;metro de 2.5 cm. El desempe&ntilde;o de la antena se midi&oacute; usando el factor <i>Q </i>para los casos cargado y sin carga cuyos resultados fueron 161.78 y 178.03 respectivamente. Estos valores concuerdan muy bien con los reportados en la literatura. Se obtuvieron im&aacute;genes de un maniqu&iacute; construido espec&iacute;ficamente para este prop&oacute;sito con isletas marcadas con un agente de contraste, usando una secuencia gradiente eco.   La interacci&oacute;n electromagn&eacute;tica entre el conjunto de gradientes insertables y la antena solenoide es pobre, y no hay evidencia de artefactos de imagen en las im&aacute;genes de cuerpo entero del rat&oacute;n. Esta experiencia preliminar muestra que esta clase de antena ofrece una alta calidad de im&aacute;genes de rat&oacute;n que es posible obtener con un sistema de 3 T. Las antenas de volumen son una buena elecci&oacute;n para obtener im&aacute;genes de alta resoluci&oacute;n espacial en investigaci&oacute;n precl&iacute;nica de ratones a campos magn&eacute;ticos altos.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Descriptores:</b> IRM de ratones; antena solenoide; simulaci&oacute;n electromagn&eacute;tica.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">PACS:  87.57.&#150;s; 87.62.+n; 87.61.&#150;c; 84.32</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><a href="/pdf/rmf/v55n2/v55n2a11.pdf" target="_blank">DESCARGAR ART&Iacute;CULO EN FORMATO PDF</a></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Acknowledgment</b></font></p>     <p align="justify"><font face="verdana" size="2">S.S.H. is supported by a post&#150;doctoral stipend from the Universidad Aut&oacute;noma Metropolitana Iztapalapa.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>References</b></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">1. B.J. Nieman <i>et al., NMR Biomed </i><b>20</b> (2007) 291.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353278&pid=S0035-001X200900020001100001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">2. R.M. Henkelman, J.G. van Heteren, and M. J. Bronskill, <i>Magn Reson Med. </i><b>61</b> (1987).</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353279&pid=S0035-001X200900020001100002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">3. F.D. Doty, G. Entzminger, J. Kulkarni, K. Pamarthy, and J.P. Staab, <i>NMR Biomed </i><b>20</b> (2007) 304.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353280&pid=S0035-001X200900020001100003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">4. C.E. Hayes, W.A. Edelstein, J.F. Schenck, O.M. Mueller, and M. <i>Eash Magn. Reson. </i><b>63</b> (1985) 622.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353281&pid=S0035-001X200900020001100004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">5. D.I. Hoult and R.E. Richards, <i>J Magn Reson.</i><b>24</b> (1976) 71.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353282&pid=S0035-001X200900020001100005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">6. D.I. Hoult, <i>Progress in NMR Spectroscopy </i><b>12</b> (1978) 41.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353283&pid=S0035-001X200900020001100006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">7. Y.L. Andrew,   G.  Webb,   S.  Saha,  W.B.  William,   and  C. Zachariah, <i>Magn. Reson. Chem. </i><b>44</b> (2006) 255.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353284&pid=S0035-001X200900020001100007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">8. K.R. Minard and R.A. Wind, <i>Conc. Magn. Reson. </i><b>13</b> (2001) 190.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353285&pid=S0035-001X200900020001100008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">9. K.R. Minard and R.A. Wind, <i>Conc. Magn. Reson. </i><b>13</b> (2001) 128.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353286&pid=S0035-001X200900020001100009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">10. T. Neuberger and A. Webb, <i>NMR Biomed. </i><b>22</b> (2009) (in press)</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353287&pid=S0035-001X200900020001100010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">11. B. Chronik, A. Alejski, and B.K. Rutt, <i>MAGMA</i> <b>10</b> (2000) 131.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353288&pid=S0035-001X200900020001100011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">12. M.A. Bernstein, K.F. King, and X.J. Zhou. Handbook of pulse sequences, (Elsevier Academic Press, Amsterdam, 2004.)</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353289&pid=S0035-001X200900020001100012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">13. J. Kriz, D. Jirak, D. White, and P. Foster, <i>Transplant Proc. </i><b>40</b> (2008) 444.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353290&pid=S0035-001X200900020001100013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">14. C. Heyn, C. Bowen, B. Rutt, and P. Foster, <i>MAGN. RESON. MED.</i> <b>53</b> (2005) 312.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353291&pid=S0035-001X200900020001100014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">15. H. Kraus, <i>Electromagnetism, </i>(McGraw Hill, N.Y., 1984).</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8353292&pid=S0035-001X200900020001100015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nieman]]></surname>
<given-names><![CDATA[B.J.]]></given-names>
</name>
</person-group>
<source><![CDATA[NMR Biomed]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>291</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henkelman]]></surname>
<given-names><![CDATA[R.M.]]></given-names>
</name>
<name>
<surname><![CDATA[van Heteren]]></surname>
<given-names><![CDATA[J.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Bronskill]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn Reson Med.]]></source>
<year>1987</year>
<volume>61</volume>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Doty]]></surname>
<given-names><![CDATA[F.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Entzminger]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Kulkarni]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Pamarthy]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Staab]]></surname>
<given-names><![CDATA[J.P.]]></given-names>
</name>
</person-group>
<source><![CDATA[NMR Biomed]]></source>
<year>2007</year>
<volume>20</volume>
<page-range>304</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hayes]]></surname>
<given-names><![CDATA[C.E.]]></given-names>
</name>
<name>
<surname><![CDATA[Edelstein]]></surname>
<given-names><![CDATA[W.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Schenck]]></surname>
<given-names><![CDATA[J.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Mueller]]></surname>
<given-names><![CDATA[O.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Eash]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson.]]></source>
<year>1985</year>
<volume>63</volume>
<page-range>622</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoult]]></surname>
<given-names><![CDATA[D.I.]]></given-names>
</name>
<name>
<surname><![CDATA[Richards]]></surname>
<given-names><![CDATA[R.E.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Magn Reson.]]></source>
<year>1976</year>
<volume>24</volume>
<page-range>71</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoult]]></surname>
<given-names><![CDATA[D.I.]]></given-names>
</name>
</person-group>
<source><![CDATA[NMR Spectroscopy]]></source>
<year>1978</year>
<volume>12</volume>
<page-range>41</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Andrew]]></surname>
<given-names><![CDATA[Y.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Webb]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Saha]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[William]]></surname>
<given-names><![CDATA[W.B.]]></given-names>
</name>
<name>
<surname><![CDATA[Zachariah]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Chem.]]></source>
<year>2006</year>
<volume>44</volume>
<page-range>255</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minard]]></surname>
<given-names><![CDATA[K.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Wind]]></surname>
<given-names><![CDATA[R.A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Conc. Magn. Reson.]]></source>
<year>2001</year>
<volume>13</volume>
<page-range>190</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minard]]></surname>
<given-names><![CDATA[K.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Wind]]></surname>
<given-names><![CDATA[R.A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Conc. Magn. Reson.]]></source>
<year>2001</year>
<volume>13</volume>
<page-range>128</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neuberger]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Webb]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[NMR Biomed.]]></source>
<year>2009</year>
<volume>22</volume>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chronik]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Alejski]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rutt]]></surname>
<given-names><![CDATA[B.K.]]></given-names>
</name>
</person-group>
<source><![CDATA[MAGMA]]></source>
<year>2000</year>
<volume>10</volume>
<page-range>131</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bernstein]]></surname>
<given-names><![CDATA[M.A.]]></given-names>
</name>
<name>
<surname><![CDATA[King]]></surname>
<given-names><![CDATA[K.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[X.J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Handbook of pulse sequences]]></source>
<year>2004</year>
<publisher-loc><![CDATA[Amsterdam ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier Academic Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kriz]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Jirak]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Foster]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Transplant Proc.]]></source>
<year>2008</year>
<volume>40</volume>
<page-range>444</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heyn]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Bowen]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Rutt]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Foster]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[MAGN. RESON. MED.]]></source>
<year>2005</year>
<volume>53</volume>
<page-range>312</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kraus]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<source><![CDATA[Electromagnetism]]></source>
<year>1984</year>
<publisher-loc><![CDATA[N.Y. ]]></publisher-loc>
<publisher-name><![CDATA[McGraw Hill]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>