<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-199X</journal-id>
<journal-title><![CDATA[Revista odontológica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Odont. Mex]]></abbrev-journal-title>
<issn>1870-199X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Facultad de Odontología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-199X2011000400006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Uso de tornillos bicorticales reabsorbibles como alternativa en cirugía ortognática de mandíbula: presentación de 2 casos y revisión de la literatura]]></article-title>
<article-title xml:lang="en"><![CDATA[Use of resorbable bicortical screws as an alternative in mandibular orthognatic surgery: Presentation of two cases and literature review]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Licéaga Reyes]]></surname>
<given-names><![CDATA[Rodrigo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Velázquez Gracia]]></surname>
<given-names><![CDATA[Guillermo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Juárez de México Servicio de Cirugía Oral y Maxilofacial ]]></institution>
<addr-line><![CDATA[México Distrito Federal]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2011</year>
</pub-date>
<volume>15</volume>
<numero>4</numero>
<fpage>239</fpage>
<lpage>243</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-199X2011000400006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-199X2011000400006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-199X2011000400006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La utilización de placas y tornillos reabsorbibles de ácidos poliláctico y poliglicólico permite que cada vez sea más común el uso de estos materiales de osteosíntesis en sustitución de los materiales tradicionales de titanio, no sólo en su aplicación pediátrica, sino también en adultos. Aunque todavía presentan algunas desventajas en relación con el titanio, como la mayor incomodidad de uso y el costo económico, muchos estudios demuestran que es una alternativa válida a la osteosíntesis con titanio en la mayoría de las situaciones clínicas. En este artículo se describen dos casos clínicos que utilizan materiales reabsorbibles como osteosíntesis maxilofacial, y se revisan las ventajas y desventajas así como las características de estos materiales. Asimismo, sus ventajas y desventajas conforme a la experiencia en 2 casos donde se utilizó este material y se documentan las indicaciones actuales de la osteosíntesis reabsorbible conforme con la literatura.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The use of plates and resorbable screws of polylactic and polyglycolic acid allows that these osteosynthesis materials be used as substitution of traditional materials like titanium, in pediatric as well as in adult cases. When compared to titanium, they still show some disadvantages like discomfort during use and financial cost, many studies show they are a valid alternative to osteosynthesis with titanium in most clinical situations. In this report two clinical cases are described where resorbable materials like maxillofacial osteosynthesis, and advantages and disadvantages are assessed as well as characteristics of these materials. Advantages and disadvantages are also assessed with respect to two cases where this material was used. Present indications of resorbable osteosynthesis according to literature are also documented.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Cirugía ortognática]]></kwd>
<kwd lng="es"><![CDATA[tornillos reabsorbibles]]></kwd>
<kwd lng="en"><![CDATA[Orthognatic surgery]]></kwd>
<kwd lng="en"><![CDATA[resorbable screws]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Caso cl&iacute;nico</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Uso de tornillos bicorticales reabsorbibles como alternativa en cirug&iacute;a ortogn&aacute;tica de mand&iacute;bula: presentaci&oacute;n de 2 casos y revisi&oacute;n de la literatura</b></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>Rodrigo Lic&eacute;aga Reyes,&#42; Guillermo Vel&aacute;zquez Gracia<sup>&sect;</sup></b></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">&#42; <i> Residente de 4to a&ntilde;o del Servicio de Cirug&iacute;a Oral y Maxilofacial, Hospital Ju&aacute;rez de M&eacute;xico.</i></font></p>     <p align="justify"><font face="verdana" size="2"><sup>&sect;</sup> <i> M&eacute;dico Adscrito al Servicio de Cirug&iacute;a Oral y Maxilofacial, Hospital Ju&aacute;rez de M&eacute;xico.</i></font></p>     <p align="justify"><font face="verdana" size="2"><a name="mail1" id="mail1"></a><a href="#mail2">Correspondencia</a></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Fecha de recepci&oacute;n: 01 de febrero de 2007    <br>Fecha de aceptaci&oacute;n: 16 de noviembre de 2007</font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>RESUMEN</b></font></p>     <p align="justify"><font face="verdana" size="2">La utilizaci&oacute;n de placas y tornillos reabsorbibles de &aacute;cidos polil&aacute;ctico y poliglic&oacute;lico permite que cada vez sea m&aacute;s com&uacute;n el uso de estos materiales de osteos&iacute;ntesis en sustituci&oacute;n de los materiales tradicionales de titanio, no s&oacute;lo en su aplicaci&oacute;n pedi&aacute;trica, sino tambi&eacute;n en adultos. Aunque todav&iacute;a presentan algunas desventajas en relaci&oacute;n con el titanio, como la mayor incomodidad de uso y el costo econ&oacute;mico, muchos estudios demuestran que es una alternativa v&aacute;lida a la osteos&iacute;ntesis con titanio en la mayor&iacute;a de las situaciones cl&iacute;nicas. En este art&iacute;culo se describen dos casos cl&iacute;nicos que utilizan materiales reabsorbibles como osteos&iacute;ntesis maxilofacial, y se revisan las ventajas y desventajas as&iacute; como las caracter&iacute;sticas de estos materiales. Asimismo, sus ventajas y desventajas conforme a la experiencia en 2 casos donde se utiliz&oacute; este material y se documentan las indicaciones actuales de la osteos&iacute;ntesis reabsorbible conforme con la literatura.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> Cirug&iacute;a ortogn&aacute;tica, tornillos reabsorbibles.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>INTRODUCCI&Oacute;N</b></font></p>     <p align="justify"><font face="verdana" size="2">Sin duda la osteos&iacute;ntesis r&iacute;gida ha supuesto uno de los mayores avances en el campo de la cirug&iacute;a maxilofacial moderna. El titanio ha demostrado sus excelentes cualidades a lo largo ya de 25 a&ntilde;os.<sup>1</sup> Sin embargo, la aparici&oacute;n y popularizaci&oacute;n de la combinaci&oacute;n de &aacute;cidos polil&aacute;ctico y poliglic&oacute;lico, ha hecho que estos nuevos materiales se utilicen cada vez m&aacute;s. Pocas dudas quedan ya en su aplicaci&oacute;n pedi&aacute;trica, pero todav&iacute;a suscita controversia su utilizaci&oacute;n en cirug&iacute;a maxilofacial de adultos;<sup>2 </sup>con el uso de materiales de titanio la necesidad de una segunda operaci&oacute;n en algunos casos, es necesaria para la remoci&oacute;n de estos tornillos y todas las desventajas de los materiales met&aacute;licos como la palpaci&oacute;n, sensibilidad migraci&oacute;n, obstrucci&oacute;n en la radiograf&iacute;a, posible reabsorci&oacute;n &oacute;sea, alergias, y retardo en el crecimiento de los ni&ntilde;os han llevado al desarrollo de materiales reabsorbibles.<sup>3</sup> Estos materiales biodegradables causan inflamaci&oacute;n y son una fase necesaria para reabsorberse sin llegar a causar reacci&oacute;n t&oacute;xica. Los tornillos bicorticales reabsorbibles han sido ocupados en cirug&iacute;as craneofaciales y varios estudios comprueban la seguridad y la eficacia del uso de estos materiales en osteotom&iacute;as de mand&iacute;bula.<sup>4</sup> </font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">  <b>REPORTE DEL CASO</b></font></p>     <p align="justify"><font face="verdana" size="2">Se presentan dos casos de cirug&iacute;a ortogn&aacute;tica mandibular en los que la fijaci&oacute;n interna utilizada fue por medio de tornillos bicorticales fabricados con materiales reabsorbibles.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Caso 1</b></font></p>     <p align="justify"><font face="verdana" size="2">Paciente masculino de 17 a&ntilde;os, estudiante, sin antecedentes heredofamiliares de relevancia para su padecimiento, con antecedente personal patol&oacute;gico de hepatitis a los 7 a&ntilde;os de edad, referido del departamento de ortodoncia de la Universidad Tecnol&oacute;gica de M&eacute;xico. Refiere iniciar su padecimiento en el desarrollo y hacerlo evidente en la adolescencia por lo que inici&oacute; manejo ortod&oacute;ncico. A la exploraci&oacute;n f&iacute;sica intraoral, con maxilares sin datos patol&oacute;gicos, laterognasia mandibular izquierda, con mordida cruzada posterior y sobremordida horizontal de &#45;7 mm y desviaci&oacute;n lateral de 3 mm (<a href="#a6f1" target="_self">Figura 1</a>). Los datos cefalom&eacute;tricos m&aacute;s relevantes est&aacute;n condensados en el <a href="#a6t1" target="_self">cuadro I</a>.</font></p>     <p><a name="a6f1"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6f1.jpg"></p>    <p><font size="2" face="Verdana"> </font></p>    <p><a name="a6t1"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6t1.jpg"></p>     <p align="justify"><font face="verdana" size="2">En base al diagn&oacute;stico cl&iacute;nico y cefalom&eacute;trico se proyect&oacute; una cirug&iacute;a de reducci&oacute;n de prognatismo con retroceso mandibular de 10 mm y rotaci&oacute;n hacia la derecha de 3 mm.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En sala de operaciones bajo anestesia general con intubaci&oacute;n nasotraqueal se realiz&oacute; abordaje retromolar, con exposici&oacute;n de la rama ascendente y osteotom&iacute;a sagital. Una vez realizado el procedimiento en ambos lados, con f&eacute;rula quir&uacute;rgica de acr&iacute;lico y cadena de el&aacute;sticos de un paso se llev&oacute; a nueva posici&oacute;n oclusal acordada previamente con el ortodoncista. </font></p>     <p align="justify"><font face="verdana" size="2">Se elimin&oacute; el excedente proximal y se fij&oacute;, v&iacute;a percut&aacute;nea en zona de &aacute;ngulo mandibular, con tres tornillos bicorticales de 2.8 x 16 mm (Sistema CPS, Inion) reabsorbibles (<a href="#a6f2" target="_self">Figura 2</a>). Se sutur&oacute; con material reabsorbible las heridas intraorales (vicryl 3&#45;0) y con material no reabsorbible en las heridas de piel (nylon 5&#45;0).</font></p>     <p><a name="a6f2"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6f2.jpg"></p>     <p align="justify"><font face="verdana" size="2">El postoperatorio lo curs&oacute; adecuadamente con manejo convencional de analg&eacute;sicos y antibi&oacute;ticos. En la imagen radiogr&aacute;fica no se observa el material y &uacute;nicamente se ven los sitios donde se realizaron las perforaciones para la colocaci&oacute;n de los tornillos (<a href="#a6f3" target="_self">Figura 3</a>). Se retir&oacute; la fijaci&oacute;n intermaxilar progresivamente desde la 4ta hasta 8va semana, posterior a la cual se envi&oacute; nuevamente para el manejo de ortodoncia postquir&uacute;rgica.</font></p>     <p><a name="a6f3"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6f3.jpg"></p>     <p align="justify"><font face="verdana" size="2">Desde el curso postoperatorio inmediato a 3 a&ntilde;os de control el paciente no ha cursado con complicaci&oacute;n alguna.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Caso 2</b></font></p>     <p align="justify"><font face="verdana" size="2">Paciente femenino de 18 a&ntilde;os, sin antecedentes de relevancia para su padecimiento, que refiere iniciar en la adolescencia con crecimiento mandibular sin recibir tratamiento que inicia posteriormente a&ntilde;o y medio antes de iniciar tratamiento en el departamento de ortodoncia de la Universidad Tecnol&oacute;gica de M&eacute;xico. Se descartaron antecedentes m&eacute;dicos que contraindicaran su manejo de cirug&iacute;a ortogn&aacute;tica. En los estudios cl&iacute;nicos se observ&oacute; una discrepancia en la mordida horizontal de &#45;6 mm. </font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En base a los estudios cl&iacute;nicos y cefalom&eacute;tricos se plante&oacute; un retroceso mandibular de 8 mm. Los datos cefalom&eacute;tricos m&aacute;s relevantes est&aacute;n condensados en el <a href="#a6t2" target="_self">cuadro II</a>.</font></p>     <p><a name="a6t2"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6t2.jpg"></p>     <p align="justify"><font face="verdana" size="2">En la sala de operaciones bajo anestesia general nasotraqueal se realiz&oacute; de igual forma la osteotom&iacute;a sagital de rama ascendente bilateral, se logr&oacute; un retroceso mandibular y rotaci&oacute;n a la derecha, llevando a nueva posici&oacute;n oclusal con f&eacute;rula quir&uacute;rgica. Despu&eacute;s de eliminar el excedente proximal se fijaron los segmentos con 3 tornillos bicorticales de 2.8 x 16 mm (Sistema CPS, Inion) a cada lado colocados v&iacute;a percut&aacute;nea (<a href="#a6f4" target="_self">Figura 4</a>). Se sutur&oacute; con material reabsorbible las heridas intraorales (vicryl 3&#45;0) y con material no reabsorbible en las heridas de piel (nylon 5&#45;0). </font></p>     <p><a name="a6f4"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6f4.jpg"></p>     <p align="justify"><font face="verdana" size="2">Curs&oacute; el postoperatorio sin eventualidades con manejo convencional de analg&eacute;sicos y antibi&oacute;ticos. Se comenz&oacute; a retirar la fijaci&oacute;n intermaxilar a la 4ta semana y a la 7ta semana se envi&oacute; para el manejo de ortodoncia postquir&uacute;rgica.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>DISCUSI&Oacute;N</b></font></p>     <p align="justify"><font face="verdana" size="2">La fijaci&oacute;n interna r&iacute;gida con materiales met&aacute;licos es una t&eacute;cnica est&aacute;ndar que se ha mantenido durante casi 30 a&ntilde;os utilizados para alinear los segmentos &oacute;seos en el periodo de cicatrizaci&oacute;n.<sup>5</sup> Los primeros materiales bioreabsorbibles fueron utilizados en membranas para regeneraci&oacute;n tisular guiada y suturas, posteriormente los primeros reportes cl&iacute;nicos de placas reabsorbibles fueron publicados cerca de 1980.<sup>6</sup> Los tornillos met&aacute;licos en cirug&iacute;a maxilofacial requieren algunas veces de remoci&oacute;n secundaria por migraci&oacute;n, palpaci&oacute;n inaceptable, restricci&oacute;n del crecimiento en pacientes pedi&aacute;tricos e interferencia en diagn&oacute;sticos de imagen que conllevan radiaci&oacute;n.<sup>7</sup> Los materiales bioreabsorbibles m&aacute;s utilizados en cirug&iacute;a maxilofacial son &aacute;cidos poli&#45;alpha&#45;hydroxil de alto peso molecular: &aacute;cido polil&aacute;ctico (PLA), &aacute;cido poliglic&oacute;lico (PGA), polidioxanona (PDS), y sus copol&iacute;meros. El material utilizado es una mezcla de pol&iacute;meros r&iacute;gidos y el&aacute;sticos seleccionados por su fortaleza, maleabilidad, y propiedades de degradaci&oacute;n. Los pol&iacute;meros en el sistema CPS de Inion son: L&#45; l&aacute;ctico D, L&#45;l&aacute;ctico glic&oacute;lico y carbonato de trimetileno.<sup>8</sup></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Estos &aacute;cidos se degradan a trav&eacute;s de hidr&oacute;lisis simple en el medio acuoso de los tejidos vivos. Primero se disuelven en peque&ntilde;os fragmentos que son fagocitados por los macr&oacute;fagos y las c&eacute;lulas gigantes. Los productos resultantes de la degradaci&oacute;n del PLA (&aacute;cido polil&aacute;ctico) y del PGA (&aacute;cido poliglic&oacute;lico) son metabolizados en bi&oacute;xido de carbono y agua y son eliminados en la respiraci&oacute;n.<sup>9,10</sup> Turvey han publicado su experiencia en 70 pacientes de cirug&iacute;a ortogn&aacute;tica bimaxilar con seguimiento a corto plazo (6&#45;24 meses). Tres pacientes tuvieron problemas con la p&eacute;rdida de tornillos pero la estabilidad y la oclusi&oacute;n fueron adecuadas en todos los pacientes.<sup>11</sup> </font></p>     <p align="justify"><font face="verdana" size="2">Una de las ventajas del material reabsorbible es la de ser adecuado para soportar los fragmentos &oacute;seos durante el periodo de cicatrizaci&oacute;n y adem&aacute;s reabsorberse en su totalidad cuando el hueso se ha consolidado, sin que los metabolitos resultantes causen ninguna alteraci&oacute;n local o sist&eacute;mica. Matthews y cols, han estudiado la estabilidad de los tornillos SR&#45;PLLA (Inion) reabsorbibles en la osteos&iacute;ntesis de la osteotom&iacute;a sagital mandibular de avance en 11 pacientes, compar&aacute;ndola con un n&uacute;mero 11 pacientes sometidos a la misma osteotom&iacute;a fijada con titanio, y no encontraron diferencias significativas entre ambos grupos al comparar la estabilidad cefalom&eacute;trica con seguimiento de un a&ntilde;o. Estas caracter&iacute;sticas proporcionan indudables ventajas sobre todo porque no precisan un segundo tiempo para retirar el material utilizado.<sup>12</sup></font></p>     <p align="justify"><font face="verdana" size="2">Fuente del Campo, ha publicado en un estudio multic&eacute;ntrico, su experiencia en osteos&iacute;ntesis maxilofacial con material reabsorbible PLLA (&aacute;cido poli L&#45;l&aacute;ctico) en 208 casos, de los cuales 142 correspond&iacute;an a cirug&iacute;a ortogn&aacute;tica, con un seguimiento m&aacute;ximo de 8 a&ntilde;os. Este autor ha observado una tasa de complicaciones del 7.9%: 2 casos de inestabilidad maxilar por mala t&eacute;cnica, 6 casos de granuloma, 4 casos de exposici&oacute;n de placa y otros 4 de desplazamiento de la misma, la mayor parte de estas complicaciones atribuidas han sido a la t&eacute;cnica y no al material empleado.<sup>13</sup> El manejo de estos tornillos es dif&iacute;cil en comparaci&oacute;n al que estamos habituados con el titanio, por lo que inicialmente el tiempo quir&uacute;rgico es mayor aproximadamente de 10 a 15 minutos, esto es debido al proceso de formaci&oacute;n de rosca para el orificio que requiere la mayor&iacute;a de los sistemas; el desarrollo de pistolas para introducir los tornillos en el agujero sin necesidad de machuelo ha posibilitado disminuir el tiempo quir&uacute;rgico sin ocasionar problema a sus propiedades mec&aacute;nicas.<sup>14</sup> Otra de las posibles desventajas del material reabsorbible es que radiogr&aacute;ficamente se observan radiol&uacute;cidos y por lo tanto no son visibles, s&oacute;lo se observa el orificio, esto ocasionalmente puede dificultar actitudes diagn&oacute;sticas cuando hay problemas de consolidaci&oacute;n (<a href="#a6f5" target="_self">Figura 5</a>).<sup>15</sup> La estabilidad de los tornillos reabsorbibles en las osteotom&iacute;as sagitales ha sido estudiada en diferentes art&iacute;culos, as&iacute; como la evaluaci&oacute;n cl&iacute;nica y radiogr&aacute;fica, de la estabilidad esquel&eacute;tica y la cicatrizaci&oacute;n &oacute;sea.<sup>16</sup> Algunos estudios biomec&aacute;nicos de Kohn en mand&iacute;bula de cad&aacute;veres humanos se evalu&oacute; el desplazamiento con tornillos reabsorbibles PLLA/PGA y tornillos de titanio bicorticales donde fueron sometidos a fuerza sobre una viga, comprobaron que no existe una diferencia significativa entre los tornillos de titanio y los tornillos.<sup>17</sup> Dos tornillos por arriba del paquete neurovascular pueden ser suficientes para proveer una fijaci&oacute;n satisfactoria en los segmentos &oacute;seos y si se requiriera un tercer tornillo, el mejor lugar para colocarlo es por debajo del paquete neurovascular cerca del borde inferior de la mand&iacute;bula.<sup>18</sup> Con base en un estudio con seguimiento a 10 a&ntilde;os se menciona que los problemas que se presentan son raros y similares a los que se presentan con el titanio; por lo tanto, la complicaci&oacute;n puede ser considerada menor. La &uacute;nica diferencia es que puede presentarse tejido de granulaci&oacute;n que no requiere cirug&iacute;a a menos que el material sea palpable en la zona.<sup>19</sup> Parece claro que en cirug&iacute;a ortogn&aacute;tica mandibular el material reabsorbible es una alternativa absolutamente v&aacute;lida al titanio, eventualmente lo m&aacute;s probables es que los materiales reabsorbibles sean los &uacute;nicos utilizados y desplacen al titanio como &eacute;ste desplazo al acero.<sup>20</sup></font></p>     <p><a name="a6f5"></a></p>    <p align="center"><img src="/img/revistas/rom/v15n4/a6f5.jpg"></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>CONCLUSIONES</b></font></p>     <p align="justify"><font face="verdana" size="2">La utilizaci&oacute;n de placas y tornillos reabsorbibles en la osteos&iacute;ntesis maxilofacial utilizada hoy en d&iacute;a es una alternativa v&aacute;lida a la osteos&iacute;ntesis con titanio en la mayor&iacute;a de las situaciones cl&iacute;nicas. Actualmente, presentan todav&iacute;a algunas desventajas en relaci&oacute;n con el titanio, como incomodidad de uso y un elevado costo. Si excluimos las fracturas con fragmentos peque&ntilde;os y conminutadas, as&iacute; como otras situaciones espec&iacute;ficas donde haya excesiva fuerza de tracci&oacute;n muscular, el material reabsorbible puede utilizarse al igual que aquel de titanio en la osteos&iacute;ntesis maxilofacial.</font></p>     <p align="justify"><font face="verdana" size="2">Las propiedades mec&aacute;nicas de los tornillos reabsorbibles aplicados en fijaci&oacute;n de cirug&iacute;a ortogn&aacute;tica son comparables con los sistemas de fijaci&oacute;n de metal. Las metas de inmovilizaci&oacute;n, fijaci&oacute;n y estabilizaci&oacute;n son cumplidas por este tipo de materiales. La estabilidad esqueletal es suficiente para el tiempo requerido de cicatrizaci&oacute;n &oacute;sea. </font></p>     <p align="justify"><font face="verdana" size="2">Durante a&ntilde;os los materiales reabsorbibles, han demostrado buenos resultados en situaciones que no est&aacute;n sometidas a tracci&oacute;n muscular y, a partir de la experiencia obtenida con estos casos, podemos concluir que los tornillos biodegradables tienen el potencial para fijar con &eacute;xito las osteotom&iacute;as sagitales de mand&iacute;bula colocando los tornillos bicorticales del grosor adecuado como lo hicimos en los casos que presentamos, situaci&oacute;n donde existe gran tracci&oacute;n muscular y no s&oacute;lo en casos sin tensi&oacute;n como se usaba hasta hace unos a&ntilde;os.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La revisi&oacute;n de la literatura nos ha demostrado los excelentes resultados de uso de fijaci&oacute;n interna r&iacute;gida reabsorbible en tercio medio, ahora se inicia la experiencia de fijaci&oacute;n interna reabsorbible mandibular, por lo que a largo plazo podremos reevaluar los resultados y seguramente en algunos a&ntilde;os, el uso de titanio estar&aacute; limitado a casos de reconstrucci&oacute;n donde se requiere material de un perfil mayor. </font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2"><b>REFERENCIAS</b></font></p>    <!-- ref --><p align="justify"><font face="verdana" size="2">1.	Araujo M, Waite P, Lemons J. Strength Analysis of Le Fort I osteotomy fixation: titanium <i> versus</i>  resorbable plates. <i> J Oral Maxillofac Surg</i>  2001; 59: 1034&#45;1039.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921954&pid=S1870-199X201100040000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">2.	Suuronen R, Kallela I, Lindqvist C. Bioabsorbable plates and screws: Current state of the art in facial fracture repair. <i> J Craniomaxillofac Surg</i>  2000; 6: 19&#45;27.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921956&pid=S1870-199X201100040000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">3.	Kaan C, Enislidis G, Schopper C, Turhani D, Wanschit F, Wagner A, Watzinger, Ewers R. Fixation of mandibular fractures with biodegradable plates and screws. <i> Oral Surg Oral Med Oral Pathol Oral Radiol Endod</i>  2002; 94: 294&#45;300.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921958&pid=S1870-199X201100040000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">4.	Shand JM, Heggie A. Use of a resorbable fixation system in orthognathic. <i> J Oral Maxillofac Surg</i>  2000; 38: 335&#45;337.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921960&pid=S1870-199X201100040000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">5.	Cilasun U, Uckana S, Dolanmazb D, Saglam H. Immediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheep. <i> Br J Oral Maxillofac Surg</i>  (2006), en prensa.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921962&pid=S1870-199X201100040000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">6.	Gerlach KL, Krause KR, Eitenmuller J. Use of absorbable osteosynthesis material for mandibular fracture treatment of dogs. In: Pizzoferrato A, Marchetti WG, Ravagliori A, Lee AJC, eds: <i> Biomaterials and Clinical Applications</i> . Amsterdam: Elsevier 1987: 459&#45;464.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921964&pid=S1870-199X201100040000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">7.	Rubin JP, Yaremchuk MJ. Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature. <i> Plast Reconstr Surg</i>  1997; 100: 1336&#45;1353.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921966&pid=S1870-199X201100040000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">8.	Weiler A, Helling HJ, Kirch U. Foreign&#45;body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep. <i> J Bone Joint Surg Am</i>  1996; 78: 369&#45;76.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921968&pid=S1870-199X201100040000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">9.	Simon JA, Ricci JL, Di Cesare PE. Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part I. Basic science and preclinical studies. <i> Am J Orthop</i>  1997; 26: 665&#45;671.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921970&pid=S1870-199X201100040000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">10.	Bergsma JE, Bruijn C, Rozema FR, Bos RR, Boering G. Late degradation tissue response to poly(L&#45;lactide) bone plates and screws. <i> Biomaterials</i>  1995; 16:25&#45;31.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921972&pid=S1870-199X201100040000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">11.	Turvey TA, Bell RB, Tejera TJ, Proffit WR. The use of self&#45;reinforced biodegradable bone plates and screws in orthognatic surgery. <i> J Oral Maxillofac Surg</i>  2002; 60: 59&#45;65.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921974&pid=S1870-199X201100040000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">12.	Matthews NS, Khambay BS, Ayoub AF, Koppel D, Wood G. Preliminary assessment of skeletal stability after sagital split mandibular advancement using a bioresorbable fixation system. <i> J Oral Maxillofac Surg</i>  2003; 41: 179&#45;84.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921976&pid=S1870-199X201100040000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">13.	Fuente del Campo A. Estabilidad a largo plazo con placas absorbibles para fijaci&oacute;n interna en cirug&iacute;a ortogn&aacute;tica. <i> Cir Ciruj</i>  2003; 71: 93&#45;9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921978&pid=S1870-199X201100040000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">14.	Tiainen J, Leinonen S, Ilom&auml;ki J, Suokas E, T&ouml;rm&auml;l&auml; P, Waris TH, Ashammakhi N. Comparison of the pull&#45;out forces of bioabsorbable polylactide/glycolide screws (Biosorb and Lactosorb) and tacks: A study on the stability of fixation in human cadaver parietal bones. <i> J Craniomaxillofac Surg</i>  2002; 13: 538&#45;43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921980&pid=S1870-199X201100040000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">15.	Suuronen R, Pohjonen T, Vasenius J, Vainionpaa S. Comparison of absorbable self&#45;reinforced multilayer poly&#45;l&#45;lactide and metallic plates for the fixation of mandibular body osteotomies: an experimental study in sheep. <i> J Oral Maxillofac Surg</i>  1992; 50: 255&#45;562.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921982&pid=S1870-199X201100040000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">16.	Feretti C, Reyneke JP. Mandibular sagittal split osteotomies fixed with biodegradable or titanium screws: a prospective, comparative study of postoperative stability. <i> Oral Surg Oral Med Oral Pathol Oral Radiol Endod</i>  2002; 93: 534&#45;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921984&pid=S1870-199X201100040000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">17.	Kohn DH, Richmond EM, Dootz ER, Feinberg SE, Pietrzak WS. <i> In vitro</i>  comparison of parameters affecting the fixation strength of sagittal split osteotomies. <i> J Oral Maxillofac Surg</i>  1995; 53: 1374&#45;83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921986&pid=S1870-199X201100040000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">18.	Shand JM, Heggie AA. Use of a resorbable fixation system in orthognathic surgery. <i> Br J Oral Maxillofac Surg</i>  2000; 38: 335&#45;337.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921988&pid=S1870-199X201100040000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">19.	Laine P, Kontio C, Lindqvist C, Suuronen R. Are there any complications with bioabsorbable fixation devices? A 10 year review in orthognathic surgery. <i> J. Oral Maxillofac Surg </i> 2004; 33: 240&#45;244.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921990&pid=S1870-199X201100040000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">20.	Lic&eacute;aga RR. Nuevas tecnolog&iacute;as en cirug&iacute;a maxilofacial. <i> Rev Hosp Jua Mex</i>  2005; 72 (1): 33&#45;36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8921992&pid=S1870-199X201100040000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2"><a name="mail2"></a><a href="#mail1"><img src="/img/revistas/rom/v15n4/flecha.jpg" alt=""></a>Direcci&oacute;n para correspondencia:     <br> <b>Dr. Guillermo Vel&aacute;zquez Gracia</b>     <br> Hospital Ju&aacute;rez de M&eacute;xico     <br> Tel. 55 16 98 13 49 </font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2"><b>Nota</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Este art&iacute;culo puede ser consultado en versi&oacute;n completa en <a href="http://www.medigraphic.com/facultadodontologiaunam" target="_blank">http://www.medigraphic.com/facultadodontologiaunam</a></font></p>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Araujo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Waite]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lemons]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Strength Analysis of Le Fort I osteotomy fixation: titanium versus resorbable plates]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>2001</year>
<volume>59</volume>
<page-range>1034-1039</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suuronen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kallela]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Lindqvist]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bioabsorbable plates and screws: Current state of the art in facial fracture repair]]></article-title>
<source><![CDATA[J Craniomaxillofac Surg]]></source>
<year>2000</year>
<volume>6</volume>
<page-range>19-27</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Enislidis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Schopper]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Turhani]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wanschit]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Watzinger]]></surname>
</name>
<name>
<surname><![CDATA[Ewers]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fixation of mandibular fractures with biodegradable plates and screws]]></article-title>
<source><![CDATA[Oral Surg Oral Med Oral Pathol Oral Radiol Endod]]></source>
<year>2002</year>
<volume>94</volume>
<page-range>294-300</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shand]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Heggie]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of a resorbable fixation system in orthognathic]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>2000</year>
<volume>38</volume>
<page-range>335-337</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cilasun]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Uckana]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dolanmazb]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Saglam]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Immediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheep]]></article-title>
<source><![CDATA[Br J Oral Maxillofac Surg]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gerlach]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Krause]]></surname>
<given-names><![CDATA[KR]]></given-names>
</name>
<name>
<surname><![CDATA[Eitenmuller]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of absorbable osteosynthesis material for mandibular fracture treatment of dogs]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Pizzoferrato]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Marchetti]]></surname>
<given-names><![CDATA[WG]]></given-names>
</name>
<name>
<surname><![CDATA[Ravagliori]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[AJC]]></given-names>
</name>
</person-group>
<source><![CDATA[Biomaterials and Clinical Applications]]></source>
<year>1987</year>
<page-range>459-464</page-range><publisher-loc><![CDATA[Amsterdam ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rubin]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Yaremchuk]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature]]></article-title>
<source><![CDATA[Plast Reconstr Surg]]></source>
<year>1997</year>
<volume>100</volume>
<page-range>1336-1353</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weiler]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Helling]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kirch]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>1996</year>
<volume>78</volume>
<page-range>369-76</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simon]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Ricci]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Di Cesare]]></surname>
<given-names><![CDATA[PE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part I. Basic science and preclinical studies]]></article-title>
<source><![CDATA[Am J Orthop]]></source>
<year>1997</year>
<volume>26</volume>
<page-range>665-671</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergsma]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Bruijn]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rozema]]></surname>
<given-names><![CDATA[FR]]></given-names>
</name>
<name>
<surname><![CDATA[Bos]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Boering]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Late degradation tissue response to poly(L-lactide) bone plates and screws]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1995</year>
<volume>16</volume>
<page-range>25-31</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Turvey]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
<name>
<surname><![CDATA[Bell]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Tejera]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Proffit]]></surname>
<given-names><![CDATA[WR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of self-reinforced biodegradable bone plates and screws in orthognatic surgery]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>2002</year>
<volume>60</volume>
<page-range>59-65</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matthews]]></surname>
<given-names><![CDATA[NS]]></given-names>
</name>
<name>
<surname><![CDATA[Khambay]]></surname>
<given-names><![CDATA[BS]]></given-names>
</name>
<name>
<surname><![CDATA[Ayoub]]></surname>
<given-names><![CDATA[AF]]></given-names>
</name>
<name>
<surname><![CDATA[Koppel]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wood]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preliminary assessment of skeletal stability after sagital split mandibular advancement using a bioresorbable fixation system]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>2003</year>
<volume>41</volume>
<page-range>179-84</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fuente del Campo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estabilidad a largo plazo con placas absorbibles para fijación interna en cirugía ortognática]]></article-title>
<source><![CDATA[Cir Ciruj]]></source>
<year>2003</year>
<volume>71</volume>
<page-range>93-9</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tiainen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Leinonen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ilomäki]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Suokas]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Törmälä]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Waris]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
<name>
<surname><![CDATA[Ashammakhi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the pull-out forces of bioabsorbable polylactide/glycolide screws (Biosorb and Lactosorb) and tacks: A study on the stability of fixation in human cadaver parietal bones]]></article-title>
<source><![CDATA[J Craniomaxillofac Surg]]></source>
<year>2002</year>
<volume>13</volume>
<page-range>538-43</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suuronen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Pohjonen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Vasenius]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Vainionpaa]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of absorbable self-reinforced multilayer poly-l-lactide and metallic plates for the fixation of mandibular body osteotomies: an experimental study in sheep]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>1992</year>
<volume>50</volume>
<page-range>255-562</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feretti]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Reyneke]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mandibular sagittal split osteotomies fixed with biodegradable or titanium screws: a prospective, comparative study of postoperative stability]]></article-title>
<source><![CDATA[Oral Surg Oral Med Oral Pathol Oral Radiol Endod]]></source>
<year>2002</year>
<volume>93</volume>
<page-range>534-7</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kohn]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
<name>
<surname><![CDATA[Richmond]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Dootz]]></surname>
<given-names><![CDATA[ER]]></given-names>
</name>
<name>
<surname><![CDATA[Feinberg]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Pietrzak]]></surname>
<given-names><![CDATA[WS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro comparison of parameters affecting the fixation strength of sagittal split osteotomies]]></article-title>
<source><![CDATA[J Oral Maxillofac Surg]]></source>
<year>1995</year>
<volume>53</volume>
<page-range>1374-83</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shand]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Heggie]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of a resorbable fixation system in orthognathic surgery]]></article-title>
<source><![CDATA[Br J Oral Maxillofac Surg]]></source>
<year>2000</year>
<volume>38</volume>
<page-range>335-337</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Laine]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kontio]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Lindqvist]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Suuronen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Are there any complications with bioabsorbable fixation devices: A 10 year review in orthognathic surgery]]></article-title>
<source><![CDATA[J. Oral Maxillofac Surg]]></source>
<year>2004</year>
<volume>33</volume>
<page-range>240-244</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Licéaga]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Nuevas tecnologías en cirugía maxilofacial]]></article-title>
<source><![CDATA[Rev Hosp Jua Mex]]></source>
<year>2005</year>
<volume>72</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>33-36</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
