<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402022000300342</article-id>
<article-id pub-id-type="doi">10.24875/acm.21000218</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Primer choque apropiado del desfibrilador automático implantable en pacientes con cardiopatía chagásica]]></article-title>
<article-title xml:lang="en"><![CDATA[First appropriate implantable defibrillator shocks in patients with Chagasic heart disease]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-Chamorro]]></surname>
<given-names><![CDATA[Luis G.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Zaidel]]></surname>
<given-names><![CDATA[Ezequiel J.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gheco]]></surname>
<given-names><![CDATA[Lara]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Oliva]]></surname>
<given-names><![CDATA[Matías A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vega]]></surname>
<given-names><![CDATA[Alejandro de la]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Orosco]]></surname>
<given-names><![CDATA[Agustín]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Armentano]]></surname>
<given-names><![CDATA[Juan]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sosa-Liprandi]]></surname>
<given-names><![CDATA[Álvaro]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Sanatorio Güemes Servicio de Cardiología ]]></institution>
<addr-line><![CDATA[Buenos Aires ]]></addr-line>
<country>Argentina</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Sanatorio Güemes Servicio de Cardiología Unidad de Electrofisiología]]></institution>
<addr-line><![CDATA[Buenos Aires ]]></addr-line>
<country>Argentina</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2022</year>
</pub-date>
<volume>92</volume>
<numero>3</numero>
<fpage>342</fpage>
<lpage>348</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402022000300342&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402022000300342&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402022000300342&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen  Objetivos: Determinar si los pacientes con cardiopatía chagásica (CCh) presentaron choques apropiados del desfibrilador automático implantable (DAI) de manera más precoz que los pacientes con cardiopatía isquémica (CI).  Métodos: Estudio de cohorte retrospectivo que incluyó los pacientes con CCh y CI en quienes se implantó un DAI entre los años 2009 y 2018 en un hospital de alta complejidad. El seguimiento se realizó hasta los 36 meses, evaluándose el momento del primer choque apropiado del dispositivo.  Resultados: Se incluyeron 64 pacientes, 20 con CCh y 44 con CI. Se observó que una mayor proporción de pacientes con CCh presentaron choques apropiados durante el primer año (hazard ratio [HR]: 8.4; intervalo de confianza del 95% [IC95%]: 2.09-34.02; p = 0.0027) y a 3 años (HR: 4.61; IC95%: 1.51-14.07; p = 0.0072). El 100% de la población con CCh e implante del DAI como prevención secundaria de muerte súbita presentaron choques apropiados durante los primeros 26 meses de seguimiento.  Conclusiones: Los pacientes con CCh presentaron choques apropiados del DAI de manera más precoz que los pacientes con CI. Todos los pacientes con CCh y DAI como prevención secundaria presentaron choques apropiados, representando una población de mayor riesgo. Esta información apoya la indicación del DAI en estos pacientes a pesar de la escasa evidencia en ensayos aleatorizados.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract  Objetives: To assess if patients with Chagasic heart disease (CHD) received effective automatic implantable defibrillator (AID) shocks earlier than patients with ischemic heart disease (IHD).  Methods: Retrospective cohort of patients with CHD and IHD who received an implantable cardioverter defibrillator (ICD) between 2009 and 2018, in a tertiary hospital. We evaluated the time between the implant of ICD and the first effective shock in patients with CHD and compared it with the IHD control population.  Results: We included a total of 64 patients, 20 with CHD and 44 with IHD. CHD patients presented earlier an effective shock than patients with IHD during the first year (hazard ratio [HR]: 8.4; 95% confidence interval [95% CI]: 2.09-34.02; p = 0.0027), and at three years (HR: 4.61; 95% CI: 1.51-14.07; p = 0.0072). 100% of CHD patients who received the ICD as secondary prevention of sudden cardiac death presented an effective shock during the first 26 months of follow-up.  Conclusions: Patients with CHD received effective ICD shocks earlier than the IHD patients. All patients with CHD and ICD as secondary prevention had an appropriate ICD shock at short term, representing the highest risk population, and supporting the indication of the device in a setting where randomized clinical trials are lacking.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Desfibrilador automático implantable]]></kwd>
<kwd lng="es"><![CDATA[Cardiopatía chagásica]]></kwd>
<kwd lng="es"><![CDATA[Enfermedad de Chagas]]></kwd>
<kwd lng="es"><![CDATA[Cardiopatía isquémica]]></kwd>
<kwd lng="es"><![CDATA[Muerte súbita]]></kwd>
<kwd lng="en"><![CDATA[Automatic implantable defibrillator]]></kwd>
<kwd lng="en"><![CDATA[Chagas cardiomyopathy]]></kwd>
<kwd lng="en"><![CDATA[Chagas disease]]></kwd>
<kwd lng="en"><![CDATA[Ischemic heart disease]]></kwd>
<kwd lng="en"><![CDATA[Sudden death]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mills]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Chagas disease:epidemiology and barriers to treatment]]></article-title>
<source><![CDATA[Am J Med]]></source>
<year>2020</year>
<volume>133</volume>
<page-range>1262-126</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ventura-García]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Roura]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Pell]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Pool]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Aldasoro]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Mun]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Socio-cultural aspects of Chagas disease:a systematic review of qualitative research]]></article-title>
<source><![CDATA[PLoS Negl Trop Dis]]></source>
<year>2013</year>
<volume>7</volume>
<page-range>2410</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Requena-Méndez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Aldasoro]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[de Lazzari]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sicuri]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[DAj]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Prevalence of Chagas disease in Latin-American migrants living in Europe:a systematic review and meta-analysis]]></article-title>
<source><![CDATA[PLoS Negl Trop Dis]]></source>
<year>2015</year>
<volume>9</volume>
<page-range>1-15</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schmunis]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Yadon]]></surname>
<given-names><![CDATA[ZE]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Chagas disease:a Latin American health problem becoming a world health problem]]></article-title>
<source><![CDATA[Acta Trop]]></source>
<year>2010</year>
<volume>115</volume>
<page-range>14-21</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Di Toro]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Baranchuk]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Sudden cardiac death in Chagas disease]]></article-title>
<source><![CDATA[Int Cardiovasc Forum J]]></source>
<year>2016</year>
<volume>7</volume>
<page-range>26-32</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Al-Jefairi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Burri]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Relevance of guideline-based ICD indications to clinical practice]]></article-title>
<source><![CDATA[Indian Heart J]]></source>
<year>2014</year>
<volume>66</volume>
<page-range>82-7</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ezekowitz]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Armstrong]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[McAlister]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Implantable cardioverter defibrillators in primary and secondary prevention:a systematic review of randomized, controlled trials]]></article-title>
<source><![CDATA[Ann Intern Med]]></source>
<year>2003</year>
<volume>138</volume>
<page-range>445-53</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
<name>
<surname><![CDATA[Da Costa Rocha]]></surname>
<given-names><![CDATA[MO]]></given-names>
</name>
<name>
<surname><![CDATA[De Oliveira]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
<name>
<surname><![CDATA[Lombardi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Ribeiro]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Efficacy and safety of implantable cardioverter-defibrillators in patients with Chagas disease]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2013</year>
<volume>15</volume>
<page-range>957-62</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borne]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
<name>
<surname><![CDATA[Varosy]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[Masoudi]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Implantable cardioverter-defibrillator shocks:epidemiology, outcomes, and therapeutic approaches]]></article-title>
<source><![CDATA[JAMA Int Med]]></source>
<year>2013</year>
<volume>173</volume>
<page-range>859-65</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cardinalli-Neto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bestetti]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Cordeiro]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Rodrigues]]></surname>
<given-names><![CDATA[VC]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Predictors of all-cause mortality for patients with chronic Chagas'heart disease receiving implantable cardioverter defibrillator therapy]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2007</year>
<volume>18</volume>
<page-range>1236-40</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Priori]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Blomström-Lundqvist]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Mazzanti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Blom]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Borggrefe]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Camm]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Guía ESC 2015 sobre el tratamiento de pacientes con arritmias ventriculares y prevención de la muerte súbita cardiaca]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>2016</year>
<volume>69</volume>
<page-range>176-1-77</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pereira]]></surname>
<given-names><![CDATA[FT]]></given-names>
</name>
<name>
<surname><![CDATA[Rocha]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Monteiro]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Rodrigues Sobrinho]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Pires]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[eto]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical course after cardioverter-defibrillator implantation:Chagasic versus ischemic patients]]></article-title>
<source><![CDATA[Arq Bras Cardiol]]></source>
<year>2016</year>
<volume>107</volume>
<page-range>99-105</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zeitler]]></surname>
<given-names><![CDATA[EP]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Khatib]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Friedman]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Yoon Han]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Poole]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Bardy]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Predicting appropriate shocks in patients with heart failure:patient level meta-analysis from SCD-HeFT and MADIT II]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2017</year>
<volume>28</volume>
<page-range>1345-51</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cardinalli-Neto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Greco]]></surname>
<given-names><![CDATA[OT]]></given-names>
</name>
<name>
<surname><![CDATA[Bestetti]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Automatic implantable cardioverter-defibrillators in Chagas'heart disease patients with malignant ventricular arrhythmias]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>467-70</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baranchuk]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Femenia]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[López-Diez]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Valentino]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Retyk]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Fragmented surface ECG was a poor predictor of appropriate therapies in patients with Chagas'cardiomyopathy and ICD implantation (fragmented ECG in CHAgas'cardiomyopathy study)]]></article-title>
<source><![CDATA[Ann Noninvasive Electrocardiol]]></source>
<year>2014</year>
<volume>19</volume>
<page-range>43-9</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grupi]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Moffa]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Sanches]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Barragan Filho]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
<name>
<surname><![CDATA[Bellotti]]></surname>
<given-names><![CDATA[GM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Holter monitoring in Chagas'heart disease]]></article-title>
<source><![CDATA[Sao Paulo Med J]]></source>
<year>1995</year>
<volume>113</volume>
<page-range>835-40</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Paola]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Horowitz]]></surname>
<given-names><![CDATA[LN]]></given-names>
</name>
<name>
<surname><![CDATA[Miyamoto]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Pinheiro]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ferreira]]></surname>
<given-names><![CDATA[DF]]></given-names>
</name>
<name>
<surname><![CDATA[Terzian]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Angiographic and electrophysiologic substrates of ventricular tachycardia in chronic Chagasic myocarditis]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1990</year>
<volume>65</volume>
<page-range>360-3</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mayo]]></surname>
<given-names><![CDATA[OP]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Speranza]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Alfie]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Robi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Deluso]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evolución del sustrato arritmogénico de las arritmias ventriculares graves en miocardiopatías chagásica e isquémico-necróticas]]></article-title>
<source><![CDATA[Rev Electro y Arritmias]]></source>
<year>2018</year>
<volume>10</volume>
<page-range>3-14</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[FM]]></given-names>
</name>
<name>
<surname><![CDATA[Minohara]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Correia]]></surname>
<given-names><![CDATA[LC]]></given-names>
</name>
<name>
<surname><![CDATA[Marin-Neto]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[da]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[ilva Menezes]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Systematic review and meta-analysis of clinical outcome after implantable cardioverter-defibrillator therapy in patients with Chagas heart disease]]></article-title>
<source><![CDATA[JACC Clin Electrophysiol]]></source>
<year>2019</year>
<volume>5</volume>
<page-range>1213-23</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Batista Sa]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Chiale]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Eloy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tentori]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Escudero]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Implantable cardioverter defibrillators and Chagas'disease:results of the ICD Registry Latin America]]></article-title>
<source><![CDATA[EP Europace]]></source>
<year>2009</year>
<volume>11</volume>
<page-range>164-8</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Elias]]></surname>
<given-names><![CDATA[TG]]></given-names>
</name>
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Rocha]]></surname>
<given-names><![CDATA[ZB]]></given-names>
</name>
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[LM]]></given-names>
</name>
<name>
<surname><![CDATA[Andrade]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Mecanismos arritmogênicos deflagradores de choque em chagásicos portadores de cardioversor-desfibrilador implantável]]></article-title>
<source><![CDATA[J Cardiac Arrhythmias]]></source>
<year>2014</year>
<volume>27</volume>
<page-range>22-6</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Flores-Ocampo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Márquez]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez-Flores]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Colín]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Predictores clínicos de tormenta arrítmica en pacientes con cardiomiopatía chagásica con un desfibrilador automático implantable]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2009</year>
<volume>79</volume>
<page-range>263-7</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scanavacca]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Epicardial ablation for ventricular tachycardia in chronic Chagas heart disease]]></article-title>
<source><![CDATA[Arq Bras Cardiol]]></source>
<year>2014</year>
<volume>102</volume>
<page-range>524-8</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henz]]></surname>
<given-names><![CDATA[BD]]></given-names>
</name>
<name>
<surname><![CDATA[Do Nascimento]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
<name>
<surname><![CDATA[Dietrich]]></surname>
<given-names><![CDATA[CD]]></given-names>
</name>
<name>
<surname><![CDATA[Dalegrave]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hernandes]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Mesas]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Simultaneous epicardial and endocardial substrate mapping and radiofrequency catheter ablation as first-line treatment for ventricular tachycardia and frequent ICD shocks in chronic chagasic cardiomyopathy]]></article-title>
<source><![CDATA[J Interv Card Electrophysiol]]></source>
<year>2009</year>
<volume>26</volume>
<page-range>195-205</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benatti]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
<name>
<surname><![CDATA[Bacal]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Heart transplantation for Chagas cardiomyopathy]]></article-title>
<source><![CDATA[J Heart Lung Transplant]]></source>
<year>2017</year>
<volume>36</volume>
<page-range>597-603</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
