<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402014000300006</article-id>
<article-id pub-id-type="doi">10.1016/j.acmx.2013.11.008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[La estimulación septal del ventrículo derecho generaría igual disincronía biventricular que la estimulación apical en pacientes con fracción de eyección conservada]]></article-title>
<article-title xml:lang="en"><![CDATA[Right ventricular septal stimulation would produce similar bi-ventricular dyssynchrony as does apical stimulation in patients with normal ejection fraction]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lange]]></surname>
<given-names><![CDATA[Juan Manuel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Manzolillo]]></surname>
<given-names><![CDATA[Hector]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Parras]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pozzer]]></surname>
<given-names><![CDATA[Domingo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Reyes]]></surname>
<given-names><![CDATA[Ignacio]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pantich]]></surname>
<given-names><![CDATA[Rolando]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto de Cardiología de Corrientes Juana Francisca Cabral Residencia de Cardiología Clínica ]]></institution>
<addr-line><![CDATA[Corrientes Corrientes]]></addr-line>
<country>Argentina</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Instituto de Cardiología de Corrientes Juana Francisca Cabral Departamento de Cardiología y Electro Fisiología ]]></institution>
<addr-line><![CDATA[Corrientes Corrientes]]></addr-line>
<country>Argentina</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Instituto de Cardiología de Corrientes Juana Francisca Cabral Departamentos de Cardiología y Ecocardiografía ]]></institution>
<addr-line><![CDATA[Corrientes Corrientes]]></addr-line>
<country>Argentina</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2014</year>
</pub-date>
<volume>84</volume>
<numero>3</numero>
<fpage>183</fpage>
<lpage>190</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402014000300006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402014000300006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402014000300006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo: Determinar si la estimulación medioseptal genera menor disincronía interventricular e intraventricular que la apical evaluada mediante ecocardiografía en pacientes con fracción de eyección conservada sometidos al implante de marcapasos VVI. Método: Estudio prospectivo que incluyó a 19 pacientes > 70 años, con indicación de implante de marcapasos VVI por bloqueo auriculoventricular completo degenerativo, frecuencia ventricular &#8804; 50 lpm y fracción de eyección &#8805; 45%. Se excluyeron portadores de fibrilación auricular, insuficiencia cardiaca, aquellos que en ritmo sinusal presentaron QRS > 120 mseg o bloqueo de rama izquierda. Se aleatorizaron 19 pacientes a 2 grupos: grupo A (47%) a implante apical y grupo B (53%) a implante septal. Resultados: La edad media fue de 75 años (± 8). Ninguno tuvo diagnóstico de insuficiencia cardiaca o cardiopatía isquémica. La disincronía intraventricular fue de A: 14.44 ± 19.76 mseg vs. B: 9 ± 36.45 mseg; A: 6.11 ± 62.11 mseg vs. B: 13 ± 38.31 mseg; A: 77 ± 53.51 mseg vs. B: 24.29 ± 80.90 mseg, p = NS. La disincronía interventricular fue de A: 46.44 ± 19.76 mseg vs. B: 42.20 ± 29.56 mseg; A: 45.33 ± 45.67 mseg vs. B: 29.80 ± 44.66 mseg; A: 46.38 ± 20 .mseg vs. B: 21 ± 27.20 mseg, p = NS) a las 48 h, 5 y 48 meses, respectivamente. Conclusión: El sitio de estimulación no generó diferencias en la disincronía biventricular. La estimulación septal presentó una tendencia no significativa a menor disincronía interventricular.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Objective: To determine in patients with normal ejection fraction, undergoing permanent VVI pacing, if medial septal stimulation has lower dyssynchrony than apical stimulation assessed by echocardiography. Method: A prospective trial, 19 patients &gt; 70 years old, scheduled for VVI pacemaker implantation for complete degenerative atrioventricular block, ventricular frequency < 50 beat per minute and ejection fraction &#8805; 45%. Patients with atrial fibrillation, heart failure, left bundle branch block and QRS durations longer than 120 milliseconds in surface electrocardiogram with sinus rhythm were excluded. Patients were randomized to apical implantation group A: 47% and septal implantation group B: 53%. Echocardiographic parameters were measured previous to the implant, 48 h, 5 and 48 months after implantation. Results: No patients had diagnosis of ischemic cardiomyopathy or heart failure. Echocardiographic parameters for interventricular dyssynchrony between groups were A: 14.44 ± 19.76 msec vs. B: 9 ± 36.45 msec; A: 6.11 ± 62.11 msec vs. B: 13 ± 38.31 msec; A: 77 ± 53.51 msec vs. B: 24.29 ± 80.90 msec, P = NS). For interventricular dyssynchrony were A: 46.44 ± 19.76 msec vs. B: 42.20 ± 29.56 msec; A: 45.33 ± 45.67 msec vs. B: 29.80 ± 44.66 msec; A: 46,38 ± 20 msec vs. B: 21 ± 27.20 msec, P = NS) at 48 h, 5 and 48 months, respectively. Conclusion: Apical site of stimulation does not increase ventricular dyssynchrony rate in patients with preserved ejection fraction. Septal stimulation showed decreased trend in interventricular dyssynchrony.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Marcapasos]]></kwd>
<kwd lng="es"><![CDATA[Resincronización cardiaca]]></kwd>
<kwd lng="es"><![CDATA[Sitio de estimulación]]></kwd>
<kwd lng="es"><![CDATA[Resincronización ventricular]]></kwd>
<kwd lng="es"><![CDATA[Disincronía]]></kwd>
<kwd lng="es"><![CDATA[Argentina]]></kwd>
<kwd lng="en"><![CDATA[Pacemaker]]></kwd>
<kwd lng="en"><![CDATA[Cardiac resynchronization]]></kwd>
<kwd lng="en"><![CDATA[Stimulation site]]></kwd>
<kwd lng="en"><![CDATA[Ventricular resynchronization]]></kwd>
<kwd lng="en"><![CDATA[Ventricular dyssynchrony]]></kwd>
<kwd lng="en"><![CDATA[Argentina]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="justify"><font face="verdana" size="4">Investigaci&oacute;n cl&iacute;nica</font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="4"><b>La estimulaci&oacute;n septal del ventr&iacute;culo derecho generar&iacute;a igual disincron&iacute;a biventricular que la estimulaci&oacute;n apical en pacientes con fracci&oacute;n de eyecci&oacute;n conservada</b></font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="3"><b>Right ventricular septal stimulation would produce similar bi&#45;ventricular dyssynchrony as does apical stimulation in patients with normal ejection fraction</b></font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="2"><b>Juan Manuel Lange<sup>a*</sup>, Hector Manzolillo<sup>b</sup>, Jorge Parras<sup>c</sup>, Domingo Pozzer<sup>b</sup>, Ignacio Reyes<sup>b</sup>, Rolando Pantich<sup>b</sup></b></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><sup>a</sup> <i>Residencia de Cardiolog&iacute;a Cl&iacute;nica, Instituto de Cardiolog&iacute;a de Corrientes Juana Francisca Cabral, Corrientes, Corrientes, Argentina.</i></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><sup>b</sup> <i>Departamento de Cardiolog&iacute;a y Electro Fisiolog&iacute;a, Instituto de Cardiolog&iacute;a de Corrientes Juana Francisca Cabral, Corrientes, Corrientes, Argentina.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><sup>c</sup> <i>Departamentos de Cardiolog&iacute;a y Ecocardiograf&iacute;a, Instituto de Cardiolog&iacute;a de Corrientes Juana Francisca Cabral, Corrientes, Corrientes, Argentina.</i></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>* Autor para correspondencia.</b>    <br> 	Correos electr&oacute;nicos: <a href="mailto:juanmanuellange@yahoo.com.ar">juanmanuellange@yahoo.com.ar</a>,	<a href="mailto:juanmalarcia@hotmail.com">juanmalarcia@hotmail.com</a> (J.M. Lange).</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2">Recibido el 10 de marzo de 2013    <br> 	Aceptado el 28 de noviembre de 2013</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b><i>Objetivo: </i></b>Determinar si la estimulaci&oacute;n medioseptal genera menor disincron&iacute;a interventricular e intraventricular que la apical evaluada mediante ecocardiograf&iacute;a en pacientes con fracci&oacute;n de eyecci&oacute;n conservada sometidos al implante de marcapasos VVI.</font></p>     <p align="justify"><font face="verdana" size="2"><b><i>M&eacute;todo: </i></b></font><font face="verdana" size="2">Estudio prospectivo que incluy&oacute; a 19 pacientes &gt; 70 a&ntilde;os, con indicaci&oacute;n de implante de marcapasos VVI por bloqueo auriculoventricular completo degenerativo, frecuencia ventricular &le; 50 lpm y fracci&oacute;n de eyecci&oacute;n &ge; 45%. Se excluyeron portadores de fibrilaci&oacute;n auricular, insuficiencia cardiaca, aquellos que en ritmo sinusal presentaron QRS &gt; 120 mseg o bloqueo de rama izquierda. Se aleatorizaron 19 pacientes a 2 grupos: grupo A (47%) a implante apical y grupo B (53%) a implante septal.</font></p>     <p align="justify"><font face="verdana" size="2"><b><i>Resultados: </i></b>La edad media fue de 75 a&ntilde;os (&plusmn; 8). Ninguno tuvo diagn&oacute;stico de insuficiencia cardiaca o cardiopat&iacute;a isqu&eacute;mica. La disincron&iacute;a intraventricular fue de A: 14.44 &plusmn; 19.76 mseg vs. B: 9 &plusmn; 36.45 mseg; A: 6.11 &plusmn; 62.11 mseg vs. B: 13 &plusmn; 38.31 mseg; A: 77 &plusmn; 53.51 mseg vs. B: 24.29 &plusmn; 80.90 mseg, p = NS. La disincron&iacute;a interventricular fue de A: 46.44 &plusmn; 19.76 mseg vs. B: 42.20 &plusmn; 29.56 mseg; A: 45.33 &plusmn; 45.67 mseg vs. B: 29.80 &plusmn; 44.66 mseg; A: 46.38 &plusmn; 20 .mseg vs. B: 21 &plusmn; 27.20 mseg, p = NS) a las 48 h, 5 y 48 meses, respectivamente.</font></p>     <p align="justify"><font face="verdana" size="2"><b><i>Conclusi&oacute;n: </i></b></font><font face="verdana" size="2">El sitio de estimulaci&oacute;n no gener&oacute; diferencias en la disincron&iacute;a biventricular. La estimulaci&oacute;n septal present&oacute; una tendencia no significativa a menor disincron&iacute;a interventricular.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> Marcapasos; Resincronizaci&oacute;n cardiaca; Sitio de estimulaci&oacute;n; Resincronizaci&oacute;n ventricular; Disincron&iacute;a; Argentina.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>  	    <p align="justify"><font face="verdana" size="2"><b><i>Objective: </i></b>To determine in patients with normal ejection fraction, undergoing permanent VVI pacing, if medial septal stimulation has lower dyssynchrony than apical stimulation assessed by echocardiography.</font></p>     <p align="justify"><font face="verdana" size="2"><b><i>Method: </i></b>A prospective trial, 19 patients &gt; 70 years old, scheduled for VVI pacemaker implantation for complete degenerative atrioventricular block, ventricular frequency &lt; 50 beat per minute and ejection fraction &ge; 45%. Patients with atrial fibrillation, heart failure, left bundle branch block and QRS durations longer than 120 milliseconds in surface electrocardiogram with sinus rhythm were excluded. Patients were randomized to apical implantation group A: 47% and septal implantation group B: 53%. Echocardiographic parameters were measured previous to the implant, 48 h, 5 and 48 months after implantation.</font></p>     <p align="justify"><font face="verdana" size="2"><b><i>Results: </i></b>No patients had diagnosis of ischemic cardiomyopathy or heart failure. Echocardiographic parameters for interventricular dyssynchrony between groups were A: 14.44 &plusmn; 19.76 msec vs. B: 9 &plusmn; 36.45 msec; A: 6.11 &plusmn; 62.11 msec vs. B: 13 &plusmn; 38.31 msec; A: 77 &plusmn; 53.51 msec vs. B: 24.29 &plusmn; 80.90 msec, <i>P</i> = NS). For interventricular dyssynchrony were A: 46.44 &plusmn; 19.76 msec vs. B: 42.20 &plusmn; 29.56 msec; A: 45.33 &plusmn; 45.67 msec vs. B: 29.80 &plusmn; 44.66 msec; A: 46,38 &plusmn; 20 msec vs. B: 21 &plusmn; 27.20 msec, <i>P</i> = NS) at 48 h, 5 and 48 months, respectively.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b><i>Conclusion: </i></b>Apical site of stimulation does not increase ventricular dyssynchrony rate in patients with preserved ejection fraction. Septal stimulation showed decreased trend in interventricular dyssynchrony.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Keywords:</b> Pacemaker; Cardiac resynchronization; Stimulation site; Ventricular resynchronization; Ventricular dyssynchrony; Argentina.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La estimulaci&oacute;n cr&oacute;nica del ventr&iacute;culo derecho (VD) es utilizada como terap&eacute;utica de los trastornos del sistema de conducci&oacute;n<sup>1,2</sup>. El implante del cat&eacute;ter de estimulaci&oacute;n a nivel del &aacute;pex es la primera opci&oacute;n debido a su facilidad de acceso y estabilidad del umbral de estimulaci&oacute;n<sup>2,3</sup>. La estimulaci&oacute;n ventricular unicameral produce alteraciones mec&aacute;nicas como disincron&iacute;a inter e intraventricular, empeoramiento de la fracci&oacute;n de eyecci&oacute;n, del remodelado ventricular; empeoramiento de la clase funcional, aumento de las internaciones por insuficiencia cardiaca y ensanchamiento del QRS<sup>4&#150;11</sup>. Por ello se recomienda que en los pacientes con deterioro moderado a severo de la fracci&oacute;n de eyecci&oacute;n sea utilizada la estimulaci&oacute;n biventricular dejando para los pacientes con fracci&oacute;n de eyecci&oacute;n conservada el tratamiento convencional<sup>12&#150;16</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se estima que la causa del efecto delet&eacute;reo de la estimulaci&oacute;n unicameral es la asincron&iacute;a de la activaci&oacute;n mioc&aacute;rdica produciendo un inotropismo segmentario asim&eacute;trico<sup>15&#150;17</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">La fisiolog&iacute;a de la contracci&oacute;n establece que cuanto m&aacute;s cercano sea el sitio de estimulaci&oacute;n al haz de His menor disincron&iacute;a presentar&aacute;. La estimulaci&oacute;n del tracto de salida del VD, por su cercan&iacute;a al haz de His posee menor disincron&iacute;a, expresado en una menor duraci&oacute;n del QRS estimulado<sup>18</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Otra opci&oacute;n es la estimulaci&oacute;n del septum interventricular. Algunos estudios han mostrado que presenta menor disincron&iacute;a que a nivel apical<sup>19,20</sup>. Kypta et al., en un estudio con pacientes portadores de bloqueo auriculoventricular completo, no observaron diferencias en la fracci&oacute;n de eyecci&oacute;n ni en la prueba de ejercicio entre la estimulaci&oacute;n apical y septal<sup>21</sup>. De manera opuesta, Yu et al.<sup>22</sup> y Tops et al.<sup>23</sup> demostraron en pacientes portadores de fibrilaci&oacute;n auricular cr&oacute;nica que recibieron ablaci&oacute;n del nodo auriculoventricular e implante de marcapasos que los pacientes con estimulaci&oacute;n septal, independientemente de la fracci&oacute;n de eyecci&oacute;n previa al implante, presentaron una menor duraci&oacute;n del QRS estimulado.</font></p>  	    <p align="justify"><font face="verdana" size="2">Cano et al. en 93 pacientes encontraron que la estimulaci&oacute;n apical se acompa&ntilde;&oacute; de mayor disincron&iacute;a que la estimulaci&oacute;n septal<sup>24</sup>, mientras que Nikoo et al. no hallaron diferencias en los niveles del p&eacute;ptido natriur&eacute;tico auricular entre estos 2 grupos<sup>25</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Ante la discordancia en los resultados mostrados, nos propusimos evaluar la hip&oacute;tesis de que la estimulaci&oacute;n a nivel medio del septum interventricular presentara menor disincron&iacute;a ventricular que la estimulaci&oacute;n a nivel del &aacute;pex del VD.</font></p>  	    ]]></body>
<body><![CDATA[<p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>M&eacute;todos</b></font></p>  	    <p align="justify"><font face="verdana" size="2">El departamento de Docencia e Investigaci&oacute;n del Instituto de Cardiolog&iacute;a de Corrientes aprob&oacute; el dise&ntilde;o del estudio y se obtuvo el consentimiento informado de todos los pacientes incluidos. El motivo por el cual los pacientes recibieron marcapasos tipo VVI fue exclusivamente por razones econ&oacute;micas del medio.</font></p>  	    <p align="justify"><font face="verdana" size="2">Realizamos un estudio unic&eacute;ntrico, prospectivo, aleatorizado, en el cual se incluyeron 19 pacientes de ambos sexos, mayores de 70 a&ntilde;os de edad, con indicaci&oacute;n de implante de marcapasos definitivo tipo VVI por bloqueo auriculoventricular completo degenerativo con frecuencia de escape ventricular menor de 50 lpm y con fracci&oacute;n de eyecci&oacute;n ventricular izquierda &ge; 45%<sup>26</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Fueron excluidos del estudio los pacientes portadores de fibrilaci&oacute;n auricular cr&oacute;nica o aguda previa al bloqueo auriculoventricular, aquellos en los que en ritmo sinusal previo al bloqueo auriculoventricular la duraci&oacute;n del QRS del electrocardiograma de superficie fue &ge; 120 mseg o que presentaban bloqueo de rama izquierda y pacientes con diagn&oacute;stico de insuficiencia cardiaca aguda o cr&oacute;nica.</font></p>  	    <p align="justify"><font face="verdana" size="2">Ingresaron en el estudio 19 pacientes, los cuales fueron asignados a 2 grupos. El grupo A estaba constituido por 9 pacientes (47%) para implante del cat&eacute;ter en &aacute;pex del VD, y el grupo B con 10 pacientes (53%) para implante del cat&eacute;ter en la regi&oacute;n medioseptal del septum interventricular.</font></p>  	    <p align="justify"><font face="verdana" size="2">La aleatorizaci&oacute;n fue 1:1 utiliz&aacute;ndose como m&eacute;todo una tabla de n&uacute;mero generados al azar, y estableci&eacute;ndose 2 grupos (se asign&oacute; los n&uacute;meros impares al grupo A y los n&uacute;meros pares al grupo B). Se confeccion&oacute; un formulario con datos como edad, sexo, factores de riesgo, medicaci&oacute;n utilizada, causa de bloqueo auriculoventricular, frecuencia de escape ventricular, s&iacute;ntomas del paciente, necesidad de marcapasos transitorio, fracci&oacute;n de eyecci&oacute;n y di&aacute;metros ecocardiogr&aacute;ficos bidimensionales, valores de Doppler pulsado y continuo, sincron&iacute;a interventricular e intraventricular previa al implante y durante el seguimiento, duraci&oacute;n del QRS en el electrocardiograma de superficie, tiempo de implante del marcapasos determin&aacute;ndose el tiempo desde el momento que se realiza la incisi&oacute;n en piel hasta el momento en que se finaliza la aproximaci&oacute;n de los bordes de la incisi&oacute;n posteriormente al implante del generador.</font></p>  	    <p align="justify"><font face="verdana" size="2">El 58% de los pacientes fueron hombres. La edad media fue de 75 a&ntilde;os (&plusmn; 8). El 97% de los pacientes presentaron diagn&oacute;stico de hipertensi&oacute;n arterial, el 19% eran fumadores y el 31% diab&eacute;ticos.</font></p>  	    <p align="justify">&nbsp;</p> 	    <p align="justify"><font face="verdana" size="2"><b>T&eacute;cnica de implante del cat&eacute;ter</b></font></p>      ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Todos los cat&eacute;teres utilizados fueron endocavitarios, bipolares y de fijaci&oacute;n activa. Los implantes se realizaron en la Sala de Electrofisiolog&iacute;a monitorizando con pol&iacute;grafo EMS&reg; versi&oacute;n 4.35 de 12 derivaciones simult&aacute;neas. Se obtuvieron distintas proyecciones mediante fluoroscopia con intensificador de imagen o arco en C. Para el implante se preform&oacute; el estilete del cat&eacute;ter con curva intermedia (5 cm) y se llev&oacute; el mismo a la arteria pulmonar utiliz&aacute;ndose la proyecci&oacute;n anteroposterior.</font></p>  	    <p align="justify"><font face="verdana" size="2">Una vez en la arteria pulmonar, en el grupo A, se cambi&oacute; el estilete por otro sin curva y se traccion&oacute; hacia el VD y se posicion&oacute; en el &aacute;pex. En el grupo B se introdujo el estilete con curva corta (3 cm) y se traccion&oacute; hasta conseguir el ingreso al VD manipul&aacute;ndose el mismo hasta conseguir la posici&oacute;n medioseptal; posteriormente se rot&oacute; el cat&eacute;ter en sentido antihorario. La confirmaci&oacute;n de la posici&oacute;n correcta del cat&eacute;ter se realiz&oacute; como control, tanto en proyecci&oacute;n oblicua anterior izquierda como en oblicua anterior derecha. La confirmaci&oacute;n de la posici&oacute;n del cat&eacute;ter fue realizada mediante los criterios est&aacute;ndares<sup>27</sup>. Se fij&oacute; el cat&eacute;ter y se realizaron las pruebas de umbral, impedancia y amplitud de la onda R sensada, con dispositivo analizador Biotronik&reg; (modelo ERA 20).</font></p>  	    <p align="justify"><font face="verdana" size="2">Se consideraron par&aacute;metros aceptables un umbral &lt; IV, la impedancia entre 200 y 1,500 Ohms y el sensado de onda R &gt; 0.003 v. La frecuencia de estimulaci&oacute;n programada fue de 70 lpm para todos los pacientes.</font></p>  	    <p align="justify">&nbsp;</p> 	    <p align="justify"><font face="verdana" size="2"><b>Ecocardiograf&iacute;a</b></font></p>      <p align="justify"><font face="verdana" size="2">Se evaluaron las mediciones acordes con las recomendaciones de la Sociedad Americana de Ecocardiograf&iacute;a. Para ello se utiliz&oacute; un ec&oacute;grafo Siemens Acuson CV70&reg; con transductor multifrecuencia 2&#45;4 MHz con registro electrocardiogr&aacute;fico simult&aacute;neo.</font></p>  	    <p align="justify"><font face="verdana" size="2">Adem&aacute;s de las mediciones habituales, tambi&eacute;n se midieron las velocidades del Doppler tisular, pico S, E', A' expresada en cm/seg, y la relaci&oacute;n E'/A' con la muestra del Doppler pulsado tisular ubicado en la regi&oacute;n lateral y en la regi&oacute;n medial a nivel del anillo valvular mitral. La sincron&iacute;a intraventricular se evalu&oacute; mediante la diferencia entre el tiempo desde el comienzo del QRS hasta el valor pico de la onda S del Doppler tisular entre la regi&oacute;n lateral y la septal. La sincron&iacute;a interventricular se evalu&oacute; mediante la diferencia entre el tiempo desde el inicio del QRS y el inicio de la eyecci&oacute;n a&oacute;rtica obtenido mediante Doppler pulsado del tracto de salida del ventr&iacute;culo izquierdo en vista de 5 c&aacute;maras y el tiempo desde el inicio del QRS hasta el inicio de la eyecci&oacute;n pulmonar obtenido mediante Doppler pulsado del tracto de salida del VD en vista paraesternal eje corto a nivel de los grandes vasos. Se asumi&oacute; como disincron&iacute;a intraventricular el retraso &ge; 65 mseg y como disincron&iacute;a interventricular el retraso &ge; 40 mseg<sup>28,29</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">La fracci&oacute;n de eyecci&oacute;n del ventr&iacute;culo izquierdo se evalu&oacute; mediante el m&eacute;todo de Simpsom modificado<sup>30</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se realiz&oacute; un ecocardiograma previo al implante de marcapasos definitivo y a las 48 h, 5 y 36 meses vs. 48 meses en todos los pacientes.</font></p>  	    <p align="justify">&nbsp;</p> 	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>An&aacute;lisis estad&iacute;stico</b></font></p>      <p align="justify"><font face="verdana" size="2">Para detectar una diferencia de al menos 30 mseg en la disincron&iacute;a interventricular e intraventricular con un nivel alfa de 0.05 y una potencia del estudio del 80% se estim&oacute; necesarios 10 pacientes por grupo.</font></p>  	    <p align="justify"><font face="verdana" size="2">Los datos num&eacute;ricos fueron evaluados con medias y desviaci&oacute;n est&aacute;ndar (DE) y los cualitativos con porcentajes. La comparaci&oacute;n de las variables continuas entre ambos grupos se realiz&oacute; mediante la prueba U de Mann&#45;Withney, y para evaluar la interacci&oacute;n entre el sitio de estimulaci&oacute;n aleatorizado y la sincron&iacute;a biventricular se realiz&oacute; una prueba de Kruskal&#45;Wallis. Una p &lt; 0.05 fue considerada como estad&iacute;sticamente significativa.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Resultados</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Ning&uacute;n paciente present&oacute; diagn&oacute;stico cl&iacute;nico de cardiopat&iacute;a isqu&eacute;mica, como tampoco diagn&oacute;stico o antecedentes de internaciones por insuficiencia cardiaca. Ning&uacute;n paciente recibi&oacute; implante de marcapasos VVIR. El tiempo medio de implante del cat&eacute;ter fue para el grupo A de 47 min y para el grupo B de 56 min (p = 0.31). El seguimiento medio fue de 34 meses (m&iacute;nimo de 24 m&aacute;ximo de 42). La tasa de estimulaci&oacute;n del marcapasos fue del 98% en todos los pacientes. Esta tasa fue constante en todas las visitas de seguimiento. La frecuencia de estimulaci&oacute;n programada fue de 70 lpm. Las variables ecocardiogr&aacute;ficas y duraci&oacute;n del QRS en ritmo sinusal medidos previo al implante del marcapasos se muestran en la <a href="#t1">tabla 1.</a> La duraci&oacute;n del QRS estimulado del electrocardiograma de superficie fue para el grupo A 156 &plusmn; 22 mseg y para el grupo B 149 &plusmn; 15 mseg (p = 0.78). La comparaci&oacute;n de los valores ecocardiogr&aacute;ficos de cada grupo durante el seguimiento se muestran en la <a href="/img/revistas/acm/v84n3/a6t2.jpg" target="_blank">tabla 2</a>.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t1"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/acm/v84n3/a6t1.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">La evaluaci&oacute;n de la sincron&iacute;a intraventricular e interventricular se muestra en la <a href="/img/revistas/acm/v84n3/a6t3.jpg" target="_blank">tabla 3</a>. El an&aacute;lisis intrasujeto de la sincron&iacute;a interventricular e intraventricular se muestra en la <a href="/img/revistas/acm/v84n3/a6t4.jpg" target="_blank">tabla 4</a>. La comparaci&oacute;n del di&aacute;metro de aur&iacute;cula izquierda durante el seguimiento mostr&oacute; un aumento progresivo significativo del tama&ntilde;o (41.96 mm &plusmn; 5.96 a las 48 h; 41.94 mm &plusmn; 5.21 a los 5 meses; 44.76 mm &plusmn; 6.25 a los 48 meses, p = 0.03). Independientemente del grupo aleatorizado (grupo A: 40.23 mm vs. grupo B: 42.47 mm, p <i>=</i> 0.37; grupo A: 39.21 mm vs. grupo B: 44.4 mm, p = 0.2; grupo A: 42.69 mm vs. grupo B: 47.14 mm, p = 0.28) a las 48 h, 5 meses y 48 meses posterior al implante respectivamente.</font></p>  	    <p>&nbsp;</p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Discusi&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La estimulaci&oacute;n en el &aacute;pex del VD en pacientes con deterioro de la fracci&oacute;n de eyecci&oacute;n produce alteraciones mec&aacute;nicas que se expresan en el electrocardiograma por un aumento del ancho del QRS, un incremento del deterioro de la fracci&oacute;n de eyecci&oacute;n y de los vol&uacute;menes de fin de di&aacute;stole asociado a un incremento en la clase funcional e internaciones por insuficiencia cardiaca, generando un aumento de la morbimortalidad<sup>6&#150;11</sup>. Este impacto puede ser prevenido mediante estrategias de estimulaci&oacute;n m&iacute;nima y terapia de resincronizaci&oacute;n cardiaca<sup>30,31</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Esta evidencia gener&oacute; la b&uacute;squeda de sitios alternativos de estimulaci&oacute;n dentro del VD que produzcan menor disincron&iacute;a como pueden ser el septum interventricular, el tracto de salida y hasta el propio haz de His.</font></p>  	    <p align="justify"><font face="verdana" size="2">Nuestro trabajo evalu&oacute; en pacientes con buena fracci&oacute;n de eyecci&oacute;n 2 sitios diferentes de estimulaci&oacute;n de VD. La disincron&iacute;a biventricular evaluada mediante ecocardiograf&iacute;a a corto, medio y largo plazo no evidenci&oacute; diferencias a favor de la estimulaci&oacute;n medioseptal en la disincron&iacute;a intraventricular (grupo A: 14.44 &plusmn; 19.76 mseg vs. grupo B: 9 &plusmn; 36.45 mseg; grupo A: 6.11 &plusmn; 62.11 mseg vs. grupo B: 13 &plusmn; 38.31 mseg; grupo A: 77 &plusmn; 53.51 mseg vs. grupo B: 24.29 &plusmn; 80.90 mseg, p = NS) como tampoco en la disincron&iacute;a interventricular (grupo A: 46.44 &plusmn; 19.76 mseg vs. grupo B: 42.20 &plusmn; 29.56 mseg; grupo A: 45.33 &plusmn; 45.67 mseg vs. grupo B: 29.80 &plusmn; 44.66 mseg; grupo A: 46.38 &plusmn; 20 mseg vs. grupo B: 21 &plusmn; 27.20 mseg, p = NS)a las 48 h, 5 meses y 48 meses, respectivamente.</font></p>  	    <p align="justify"><font face="verdana" size="2">A pesar de esto, en la comparaci&oacute;n de los grupos durante el seguimiento, se observ&oacute; que la estimulaci&oacute;n medioseptal present&oacute; una tendencia no estad&iacute;sticamente significativa a menor disincron&iacute;a biventricular que la estimulaci&oacute;n apical (<a href="/img/revistas/acm/v84n3/a6t3.jpg" target="_blank">tabla 3</a>). A&uacute;n as&iacute;, en el an&aacute;lisis intrasujeto del grupo con estimulaci&oacute;n medioseptal, la disincron&iacute;a intraventricular si bien se increment&oacute; a lo largo del seguimiento, persistentemente present&oacute; menores valores de disincron&iacute;a que el grupo A. Esta tendencia tampoco fue estad&iacute;sticamente significativa mediante la prueba de Kruskal&#45;Wallis (grupo B: 9 &plusmn; 36.45 mseg, 13 &plusmn; 38.31 mseg, 24.29 &plusmn; 80.90 mseg, p = NS) a las 48 h, 5 y 48 meses respectivamente. En los pacientes con estimulaci&oacute;n apical, la disincron&iacute;a intraventricular fue increment&aacute;ndose de manera paulatina con un aumento marcado entre los 5 y 48 meses logrando superar los valores de normalidad (<a href="/img/revistas/acm/v84n3/a6t3.jpg" target="_blank">tabla 3</a>), sugiriendo el efecto delet&eacute;reo de la estimulaci&oacute;n apical. De todas maneras, esta tendencia no logr&oacute; significaci&oacute;n estad&iacute;stica (<a href="/img/revistas/acm/v84n3/a6t3.jpg" target="_blank">tabla 3</a>).</font></p>  	    <p align="justify"><font face="verdana" size="2">En el comportamiento de la sincron&iacute;a interventricular, se observ&oacute; que el grupo con estimulaci&oacute;n medioseptal present&oacute; una tendencia no estad&iacute;sticamente significativa a una reducci&oacute;n de la disincron&iacute;a (<a href="/img/revistas/acm/v84n3/a6t3.jpg" target="_blank">tabla 3</a>), y en el an&aacute;lisis individual del grupo, la disincron&iacute;a tendi&oacute;, tambi&eacute;n de manera no estad&iacute;sticamente significativa, a reducirse a lo largo del seguimiento (grupo B: 42.20 &plusmn; 29.56 mseg, 29.80 &plusmn; 44.66 mseg, 21 &plusmn; 27.20 mseg, p = NS) a las 48 h, 5 y 48 meses respectivamente. La posible causa de este fen&oacute;meno puede haber sido que ante la peque&ntilde;a pero factible alteraci&oacute;n de la sincron&iacute;a por el bloqueo auriculoventricular sumado al implante de marcapasos, sabiendo que los fen&oacute;menos mec&aacute;nicos son de lenta recuperaci&oacute;n, esta disincron&iacute;a interventricular tendi&oacute; a reducirse a lo largo del seguimiento posiblemente por la estimulaci&oacute;n pr&oacute;xima al haz de His.</font></p>  	    <p align="justify"><font face="verdana" size="2">Tampoco se demostraron cambios en la fracci&oacute;n de eyecci&oacute;n ni en los vol&uacute;menes ventriculares durante el seguimiento.</font></p>  	    <p align="justify"><font face="verdana" size="2">Como ventajas se expone que: se trat&oacute; de un trabajo aleatorizado con un seguimiento medio de 34 meses, sugiriendo la posibilidad de que en pacientes con buena fracci&oacute;n de eyecci&oacute;n la estimulaci&oacute;n a nivel apical no generar&iacute;a mayor disincron&iacute;a biventricular que la estimulaci&oacute;n en &aacute;reas cercanas al haz de His. Se hall&oacute; una tendencia no significativa de menor disincron&iacute;a inter e intraventricular en los pacientes que se sometieron a estimulaci&oacute;n medioseptal a corto, medio y largo plazo.</font></p>  	    <p align="justify"><font face="verdana" size="2">La imposibilidad de verificar estad&iacute;sticamente esta tendencia podr&iacute;a deberse a la reducida muestra obtenida, una de las desventajas de este trabajo.</font></p>  	    <p align="justify"><font face="verdana" size="2">Varios estudios postularon la superioridad de sitios de estimulaci&oacute;n alternativos al apical. Inoue et al. evaluaron la sincron&iacute;a ventricular en 114 pacientes con fracci&oacute;n de eyecci&oacute;n conservada del ventr&iacute;culo izquierdo mediante ecograf&iacute;a cardiaca con la t&eacute;cnica de seguimientos de marcas, mostrando que la disincron&iacute;a producida por la estimulaci&oacute;n del marcapasos a nivel apical es mayor que la producida por la estimulaci&oacute;n septal (&iacute;ndice de disincron&iacute;a longitudinal: &aacute;pex 87 &plusmn; 20 mseg vs. septum 56 &plusmn; 14 mseg, p = &lt; 0.001; &iacute;ndice de disincron&iacute;a radial 70 &plusmn; 46 mseg vs. 44 &plusmn; 27 mseg, p &lt; 0.001 respectivamente). A pesar de esto, no encontraron correlaci&oacute;n entre los sitios de estimulaci&oacute;n y la duraci&oacute;n del QRS ni tampoco en puntos cl&iacute;nicos<sup>32</sup>. Estos resultados expuestos son diferentes a los hallados por nosotros, posiblemente por la utilizaci&oacute;n de la t&eacute;cnica de seguimiento de marcas y de &iacute;ndices de disincron&iacute;a diferentes, los cuales poseen una mayor sensibilidad para la detecci&oacute;n de alteraciones en el movimiento ventricular que los m&eacute;todos utilizados en el presente estudio. Alhous et al. evaluaron la diferencia de la duraci&oacute;n del QRS en pacientes sometidos a implante de marcapasos tipo DDD. La evaluaci&oacute;n consisti&oacute; en el impacto en la disincron&iacute;a intraventricular, interventricular, duraci&oacute;n del QRS, la fracci&oacute;n de eyecci&oacute;n, &iacute;ndice cardiaco y la funci&oacute;n diast&oacute;lica de la estimulaci&oacute;n transitoria en distintos puntos del VD. La diferencia del QRS fue a favor de la estimulaci&oacute;n no apical, siendo menor en el tracto de salida derecho como en el septum (apical 154 &plusmn; 18 mseg vs. tracto de salida derecho 136 &plusmn; 16 mseg; medioseptal 147 &plusmn; 14 mseg, p = 0.001 y p &lt; 0.001, respectivamente), correlacion&aacute;ndose tambi&eacute;n la estimulaci&oacute;n no apical con mejor fracci&oacute;n de eyecci&oacute;n (48 &plusmn; 5% vs. 54 &plusmn; 6% vs. 52 &plusmn; 5%, respectivamente). Concluyeron que los sitios de estimulaci&oacute;n alternativos al &aacute;pex resultan en una actividad sistodiast&oacute;lica del VD m&aacute;s cercana a la fisiol&oacute;gica, repercutiendo en un menor deterioro de la fracci&oacute;n de eyecci&oacute;n<sup>33</sup>. Una de las posibles causas por la que hemos obtenidos resultados diferentes es que en el estudio de Alhous et al. la estimulaci&oacute;n no solo fue bicameral sino que se realizaron optimizaciones de los tiempos programados de retraso auriculoventriculares mediante ecocardiograf&iacute;a, situaci&oacute;n que repercutir&iacute;a positivamente en la funci&oacute;n sistodiast&oacute;lica. A su vez, el 18% de los pacientes presentaron durante la estimulaci&oacute;n AAI bloqueo de rama izquierda, lo que marcar&iacute;a que este grupo particular pose&iacute;a alteraciones basales intr&iacute;nsecas en la conducci&oacute;n y consecuentemente en la mec&aacute;nica ventricular. En nuestro estudio la estimulaci&oacute;n fue unicameral y se excluyeron los pacientes con bloqueo de rama izquierda en ritmo sinusal.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Occhetta et al. evaluaron la seguridad, factibilidad y par&aacute;metros hemodin&aacute;micos de la estimulaci&oacute;n a nivel parahisiano, en pacientes portadores de fibrilaci&oacute;n auricular, QRS angosto y buena fracci&oacute;n de eyecci&oacute;n que fueron sometidos a una ablaci&oacute;n del nodo auriculoventricular con implante de un marcapasos bicameral tipo VDD. Se observ&oacute; que el posicionamiento del cat&eacute;ter a nivel septal alto impact&oacute;, mejorando los par&aacute;metros cl&iacute;nicos de manera significativa en la clase funcional de la New York Heart Asociation (1.75 &plusmn; 0.4 vs. 2.5 &plusmn; 0.4, p = &lt; 0.05) y test de la caminata de los 6 min (431 &plusmn; 73 vs. 360 &plusmn; 71 m, p = &lt; 0.05)<sup>34</sup>. Esto evidenciar&iacute;a una mejora en la mec&aacute;nica de contracci&oacute;n, situaci&oacute;n diferente a lo obtenido en nuestro estudio posiblemente por los beneficios mencionados anteriormente de la estimulaci&oacute;n bicameral.</font></p>  	    <p align="justify"><font face="verdana" size="2">En contrapartida, otros autores han encontrado resultados similares a nuestro trabajo. Wang et al. compararon los efectos de la estimulaci&oacute;n a nivel apical con la estimulaci&oacute;n a nivel del tracto de salida del VD en la funci&oacute;n ventricular global y la motilidad regional ventricular en pacientes con buena fracci&oacute;n de eyecci&oacute;n (63% en promedio), sin enfermedad coronaria o valvular activa, fibrilaci&oacute;n auricular, insuficiencia cardiaca o bloqueo completo de rama izquierda. No se observaron diferencias en el seguimiento a 12 meses de los puntos finales. Solo se evidenci&oacute; una reducci&oacute;n significativa del retraso electromec&aacute;nico interventricular (12.1 &plusmn; 21.7 mseg vs. 32.9 &plusmn; 55.4 mseg, p = 0.04) y del intervalo preeyectivo del ventr&iacute;culo izquierdo (114.7 &plusmn; 30.3 mseg vs. 133.6 &plusmn; 33.4 mseg, p = 0.02) entre la estimulaci&oacute;n del tracto de salida del VD y la estimulaci&oacute;n apical respectivamente<sup>35</sup>. Sumado a estos datos, Lieberman et al., no pudieron demostrar diferencias al evaluar par&aacute;metros hemodin&aacute;micos como fracci&oacute;n de eyecci&oacute;n, Dp/Dt, gasto cardiaco y presi&oacute;n de fin de di&aacute;stole en pacientes con fracci&oacute;n de eyecci&oacute;n conservada y deteriorada pero sin indicaci&oacute;n de resincronizaci&oacute;n. Se observ&oacute; dentro del grupo con fracci&oacute;n de eyecci&oacute;n conservada, que no existieron diferencias en los par&aacute;metros hemodin&aacute;micos y ecocardiogr&aacute;ficos medidos entre los diferentes sitios de estimulaci&oacute;n a nivel del VD. A su vez, la estimulaci&oacute;n a nivel de la pared libre del ventr&iacute;culo izquierdo como la biventricular solo mostr&oacute; una menor duraci&oacute;n del QRS estimulado<sup>36</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">&iquest;Deber&iacute;amos abandonar definitivamente la estimulaci&oacute;n apical derecha? Los datos son claros en el caso de los pacientes con fracci&oacute;n de eyecci&oacute;n deteriorada en los cuales se generar&iacute;a un mayor deterioro<sup>37</sup>. Pero en el caso de los pacientes con fracci&oacute;n de eyecci&oacute;n conservada es necesaria m&aacute;s evidencia que clarifique el mejor sitio de estimulaci&oacute;n. Actualmente, se est&aacute;n realizando 3 estudios multic&eacute;ntricos con este objeto: el Optimize RV Follow&#45;up Selective Site Pacing Clinical Trial (Optimize RV) (ClinicalTrial.gov NCT00422669); The Protection of Left Ventricular Function During Right Ventricular Pacing. Does Right Ventricular High&#45;septal Pacing Improve Outcome Compared With Right Ventricular Apical Pacing? (ClinicalTrial.gov NCT00461734 PROTECT&#45;PACE STUDY); y el Right Ventricular Apical versus Septal Pacing (RASP) (ClinicalTrials.gov NCT00199498) que ayudar&aacute;n a esclarecer este punto.</font></p>  	    <p align="justify"><font face="verdana" size="2">Hemos observado un incremento del tama&ntilde;o de la aur&iacute;cula izquierda en el seguimiento. Esto se evidenci&oacute; en todos los pacientes independientemente del sitio de estimulaci&oacute;n (41.96 mm &plusmn; 5.96 a las 48 h, 41.94 mm &plusmn; 5.21 a los 5 meses, 44.76 mm &plusmn; 6.25 a los 48 meses, p = 0.03). La causa de este hallazgo fue posiblemente la disincron&iacute;a auriculoventricular generada por la estimulaci&oacute;n unicameral. Se descart&oacute; como causa de este fen&oacute;meno el aumento de las presiones de llenado ya que la relaci&oacute;n E/E' (8.62 vs. 10.4; 8.1 vs. 11.63; 9.47 vs. 13.8, p = NS; grupo A, grupo B a las 48 h, 5 meses y 48 meses respectivamente) no mostr&oacute; diferencias entre los grupos y se descart&oacute; tambi&eacute;n el deterioro de la fracci&oacute;n de eyecci&oacute;n porque tampoco presentaron diferencias significativas a lo largo del seguimiento (<a href="/img/revistas/acm/v84n3/a6t2.jpg" target="_blank">tabla 2</a>). Ha sido demostrado que la estimulaci&oacute;n unicameral genera un remodelado el&eacute;ctrico auricular y tambi&eacute;n una mayor incidencia de fibrilaci&oacute;n auricular, siendo posiblemente la dilataci&oacute;n auricular izquierda un paso previo y sustrato anat&oacute;mico para este evento<sup>23,38</sup>.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Limitaciones</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Una importante limitaci&oacute;n en la extrapolaci&oacute;n de los resultados es el reducido n&uacute;mero de pacientes incluidos. A&uacute;n as&iacute;, las ventajas de este estudio son que el mismo fue aleatorizado, con un seguimiento del 100% de los pacientes y un promedio de tiempo de seguimiento de 34 meses.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Conclusi&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La estimulaci&oacute;n a nivel septal no present&oacute; menor disincron&iacute;a interventricular e intraventricular que la estimulaci&oacute;n a nivel apical al corto y largo plazo. Son necesarios ensayos con mayor n&uacute;mero de pacientes para validar estos datos encontrados.</font></p>  	    ]]></body>
<body><![CDATA[<p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Financiaci&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">El financiamiento estuvo a cargo del Instituto de Cardiolog&iacute;a de Corrientes.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Conflicto de intereses</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Los autores declaran no tener ning&uacute;n conflicto de intereses.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Agradecimientos</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Es deseo de los autores agradecer la valiosa y fundamental ayuda de Luciano Mazzaro, investigador profesional superior del Departamento de Bioingenier&iacute;a de la Universidad de Denver, Colorado, Estados Unidos de Norteam&eacute;rica.</font></p>  	    <p>&nbsp;</p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Bibliograf&iacute;a</b></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">1. Epstein A, DiMarco J, Ellenbogen K, et al. ACC/AHA/HRS 2008 guidelines for device&#150;based therapy of cardiac rhythm abnormalities: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmic Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardiol. 2008;51:e1&#150;62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129823&pid=S1405-9940201400030000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">2. Furman S, Schwedel J. An intracardiac pacemaker for Stokes&#150;Adams seizures. N Engl J Med. 1959;261:943&#150;8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129825&pid=S1405-9940201400030000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">3. Vardas P, Auricchio A, Blanc J, et al. Guidelines for cardiac pacing and cardiac resynchronization therapy: The task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology. Eur Heart J. 2007;28:2256&#150;95.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129827&pid=S1405-9940201400030000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">4. Mond H, Irwin M, Morillo C, et al. The world survey of cardiac pacing and cardioverter defibrillators: Calendar year 2001. Pacing Clin Electrophysiol. 2004;27:955&#150;64.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129829&pid=S1405-9940201400030000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">5. Prinzen F, Peschar M. Relation between the pacing induced sequence of activation and left ventricular pump function in animals. Pacing Clin Electrophysiol. 2002;25:484&#150;98.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129831&pid=S1405-9940201400030000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">6. Prinzen F, Hunter W, Wyman B, et al. Mapping of regional myocardial strain and work during ventricular pacing: Experimental study using magnetic resonance imaging tagging. J Am Coll Cardiol. 1999;33:1735&#150;42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129833&pid=S1405-9940201400030000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">7. Tops L, Schalij M, Holman E, et al. Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation. J Am Coll Cardiol. 2006;48:1642&#150;8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129835&pid=S1405-9940201400030000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">8. Varma N. Left ventricular conduction delays induced by right ventricular apical pacing: Effect of left ventricular dysfunction and bundle branch block. J Cardiovasc Electrophysiol. 2008;19:114&#150;22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129837&pid=S1405-9940201400030000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">9. Skalidis E, Kochiadakis G, Koukouraki S, et al. Myocardial perfusion in patients with permanent ventricular pacing and normal coronary arteries. J Am Coll Cardiol. 2001;37:124&#150;9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129839&pid=S1405-9940201400030000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">10. Karpawich P, Rabah R, Haas J. Altered cardiac histology following apical right ventricular pacing in patients with congenital atrioventricular block. Pacing Clin Electrophysiol. 1999;22:1372&#150;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129841&pid=S1405-9940201400030000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">11. Cho G, Song J, Park W, et al. Mechanical dyssynchrony assessed by tissue Doppler imaging is a powerful predictor of mortality in congestive heart failure with normal QRS duration. J Am Coll Cardiol. 2005;46:2237&#150;43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129843&pid=S1405-9940201400030000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">12. Castellant P, Fatemi M, Bertault&#150;Valls V, et al. Cardiac resynchronization therapy: &#171;Nonresponders&#187; and &#171;hyperresponders&#187;. Heart Rhythm. 2008;5:193&#150;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129845&pid=S1405-9940201400030000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">13. Ypenburg C, van Bommel R, Borleffs C, et al. Long&#150;term prognosis after cardiac resynchronization therapy is related to the extent of left ventricular reverse remodeling at midterm followup. J Am Coll Cardiol. 2009;53:483&#150;90.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129847&pid=S1405-9940201400030000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">14. Bax J, Abraham T, Barold S, et al. Cardiac resynchronization therapy: Part 1&#150;issues before device implantation. J Am Coll Cardiol. 2005;46:2153&#150;67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129849&pid=S1405-9940201400030000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">15. Leclercq Ch, Cazeau S, Lellouche D, et al. Upgrading from single chamber right ventricular to biventricular pacing in permanently paced patients with worsening heart failure: The RD&#150;CHF study. Pacing Clin Electrophysiol. 2007;30 Suppl 1: S23&#150;30.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129851&pid=S1405-9940201400030000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">16. Marai I, Gurevitz O, Carasso S, et al. Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers. Pacing Clin Electrophysiol. 2006;29:880&#150;4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129853&pid=S1405-9940201400030000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">17. Olshansky B, Day J, Moore S, et al. Is dual&#150;chamber programming inferior to single&#150;chamber programming in an implantable cardioverter&#150;defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study. Circulation. 2007;115:9&#150;16.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129855&pid=S1405-9940201400030000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">18. De&#150;Cock C, Giudici M, Twisk J. Comparison of the haemodynamic effects of right ventricular outflow&#150;tract pacing with right ventricular apex pacing: A quantitative review. Europace. 2003;5:275278.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129857&pid=S1405-9940201400030000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">19. Victor F, Mabo P, Mansour H, et al. A randomized comparison of permanent septal versus apical right ventricular pacing: Short&#150;term results. J Cardiovasc Electrophysiol. 2006;17:238&#150;42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129859&pid=S1405-9940201400030000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">20. Burri H, Sunthorn H, Dorsaz P, et al. Thresholds and complications with right ventricular septal pacing compared to apical pacing. Pacing Clin Electrophysiol. 2007;30 Suppl 1:S75&#150;8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129861&pid=S1405-9940201400030000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">21. Kypta A, Steinwender C, Kammler J, et al. Long term outcomes in patients with atrioventricular block undergoing septal ventricular lead implantation compared with standard apical pacing. Europace. 2008;10:574&#150;9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129863&pid=S1405-9940201400030000600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">22. Yu C, Liu Y, Lin M, et al. Septal pacing preserving better left ventricular mechanical performance and contractile synchronism than apical pacing in patients implanted with an atrioventricular sequential dual chamber pacemaker. Int J Cardiol. 2007;118:97&#150;106.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129865&pid=S1405-9940201400030000600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">23. Tops L, Schalij M, Bax J. The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy. J Am Coll Cardiol. 2009;54:764&#150;76.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129867&pid=S1405-9940201400030000600023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">24. Cano O, Osca J, Sancho&#150;Tello M, et al. Comparison of effectiveness of right ventricular septal pacing versus right ventricular apical pacing. Am J Cardiol. 2010;105:1426&#150;32.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129869&pid=S1405-9940201400030000600024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">25. Nikoo M, Ghaedian M, Kafi M, et al. Effects of right ventricular septal versus apical pacing on plasma natriuretic peptide levels. J Cardiovasc Dis Res. 2011;2:104&#150;9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129871&pid=S1405-9940201400030000600025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">26. Man Yu C, Sun Chan J, Qing Zhang M, et al. Biventricular pacing in patients with bradicardia and normal ejection fraction. N Engl J Med. 2009;361:2123&#150;34.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129873&pid=S1405-9940201400030000600026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">27. Lieberman R, Grenz D, Mond H, et al. Selective site pacing: defining and reaching the selected site. Pacing Clin Electrophysiol. 2004;27:883&#150;6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129875&pid=S1405-9940201400030000600027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">28. Galderisi M, Cattaneo F, Mondillo S. Doppler echocardiography and myocardial dyssynchrony: A practical update of old and new ultrasound technologies. Cardiovasc Ultrasound. 2007;6:5&#150;28.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129877&pid=S1405-9940201400030000600028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">29. Gorcsan J III, Abraham T, Agler D, et al. Echocardiography for cardiac resynchronization therapy: recommendations for performance and reporting&#150;a report from the American Society of Echocardiography Dyssynchrony Writing Group endorsed by the Heart Rhythm Society. J Am Soc Echocardiogr. 2008;21:191&#150;213.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129879&pid=S1405-9940201400030000600029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">30. Schiller N, Shah P, Crawford M, et al. Recommendations for quantitation of the left ventricle by two&#150;dimensional echocardiography et al. Recommendations for quantitation of the left ventricle by two&#150;dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two&#45;Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989;2:358&#150;67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129881&pid=S1405-9940201400030000600030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">31. De Sisti A, M&aacute;rquez M, Tonet J, et al. Adverse effects of long&#150;term right ventricular apical pacing and identification of patients at risk of atrial fibrillation and heart failure. Pacing Clin Electrophysiol. 2012;35:1035&#150;43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129883&pid=S1405-9940201400030000600031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">32. Inoue K, Okayama H, Nishimura K, et al. Right ventricular septal pacing preserves global left ventricular longitudinal function in comparison with apical pacing. Circ J. 2011;75: 1609&#150;15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129885&pid=S1405-9940201400030000600032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">33. Alhous M, Small G, Hannah A, et al. Impact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac function. Europace. 2011;13: 1738&#150;46.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129887&pid=S1405-9940201400030000600033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">34. Occhetta E, Bortnik M, Magnani A, et al. Prevention of ventricular desynchronization by permanent para&#150;Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: A crossover, blinded, randomized study versus apical right ventricular pacing. J Am Coll Cardiol. 2006;47:1938&#150;45.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129889&pid=S1405-9940201400030000600034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">35. Wang F, Shi H, Sun Y, et al. Right ventricular outflow pacing induces less regional wall motion abnormalities in the left ventricle compared with apical pacing. Europace. 2012;14: 351&#150;7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129891&pid=S1405-9940201400030000600035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">36. Lieberman R, Padeletti L, Schreuder J, et al. Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol. 2006;48:1634&#150;41.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129893&pid=S1405-9940201400030000600036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">37. Kaye G, Stambler B, Yee R. Search for the optimal right ventricular pacing site: Design and implementation of three randomized multicenter clinical trials. Pacing Clin Electrophysiol. 2009;32:426&#150;33.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129895&pid=S1405-9940201400030000600037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">38. Sparks P, Mond H, Vohra J, et al. Electrical remodeling of the atria following loss of atrioventricular synchrony: A long&#150;term study in humans. Circulation. 1999;100:1894&#150;900.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1129897&pid=S1405-9940201400030000600038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Epstein]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[DiMarco]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ellenbogen]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmic Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2008</year>
<volume>51</volume>
<page-range>e1-62</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Furman]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Schwedel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An intracardiac pacemaker for Stokes-Adams seizures]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1959</year>
<volume>261</volume>
<page-range>943-8</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vardas]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Auricchio]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Blanc]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Guidelines for cardiac pacing and cardiac resynchronization therapy: The task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology]]></article-title>
<source><![CDATA[Eur Heart J]]></source>
<year>2007</year>
<volume>28</volume>
<page-range>2256-95</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mond]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Irwin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Morillo]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The world survey of cardiac pacing and cardioverter defibrillators: Calendar year 2001]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2004</year>
<volume>27</volume>
<page-range>955-64</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Prinzen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Peschar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Relation between the pacing induced sequence of activation and left ventricular pump function in animals]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2002</year>
<volume>25</volume>
<page-range>484-98</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Prinzen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Wyman]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mapping of regional myocardial strain and work during ventricular pacing: Experimental study using magnetic resonance imaging tagging]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1999</year>
<volume>33</volume>
<page-range>1735-42</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tops]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Schalij]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Holman]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2006</year>
<volume>48</volume>
<page-range>1642-8</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Varma]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Left ventricular conduction delays induced by right ventricular apical pacing: Effect of left ventricular dysfunction and bundle branch block]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2008</year>
<volume>19</volume>
<page-range>114-22</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Skalidis]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kochiadakis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Koukouraki]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Myocardial perfusion in patients with permanent ventricular pacing and normal coronary arteries]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2001</year>
<volume>37</volume>
<page-range>124-9</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karpawich]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Rabah]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Haas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Altered cardiac histology following apical right ventricular pacing in patients with congenital atrioventricular block]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1999</year>
<volume>22</volume>
<page-range>1372-7</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical dyssynchrony assessed by tissue Doppler imaging is a powerful predictor of mortality in congestive heart failure with normal QRS duration]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2005</year>
<volume>46</volume>
<page-range>2237-43</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Castellant]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Fatemi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bertault-Valls]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cardiac resynchronization therapy: «Nonresponders» and «hyperresponders»]]></article-title>
<source><![CDATA[Heart Rhythm]]></source>
<year>2008</year>
<volume>5</volume>
<page-range>193-7</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ypenburg]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[van Bommel]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Borleffs]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-term prognosis after cardiac resynchronization therapy is related to the extent of left ventricular reverse remodeling at midterm followup]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2009</year>
<volume>53</volume>
<page-range>483-90</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bax]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Abraham]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Barold]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cardiac resynchronization therapy: Part 1-issues before device implantation]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2005</year>
<volume>46</volume>
<page-range>2153-67</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Leclercq]]></surname>
<given-names><![CDATA[Ch]]></given-names>
</name>
<name>
<surname><![CDATA[Cazeau]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Lellouche]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Upgrading from single chamber right ventricular to biventricular pacing in permanently paced patients with worsening heart failure: The RD-CHF study]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2007</year>
<volume>30</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>S23-30</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marai]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Gurevitz]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Carasso]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>880-4</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Olshansky]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Day]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2007</year>
<volume>115</volume>
<page-range>9-16</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De-Cock]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Giudici]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Twisk]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing: A quantitative review]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2003</year>
<volume>5</volume>
<page-range>275278</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Victor]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Mabo]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Mansour]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomized comparison of permanent septal versus apical right ventricular pacing: Short-term results]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2006</year>
<volume>17</volume>
<page-range>238-42</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burri]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Sunthorn]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Dorsaz]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thresholds and complications with right ventricular septal pacing compared to apical pacing]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2007</year>
<volume>30</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>S75-8</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kypta]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Steinwender]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kammler]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long term outcomes in patients with atrioventricular block undergoing septal ventricular lead implantation compared with standard apical pacing]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2008</year>
<volume>10</volume>
<page-range>574-9</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Septal pacing preserving better left ventricular mechanical performance and contractile synchronism than apical pacing in patients implanted with an atrioventricular sequential dual chamber pacemaker]]></article-title>
<source><![CDATA[Int J Cardiol]]></source>
<year>2007</year>
<volume>118</volume>
<page-range>97-106</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tops]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Schalij]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bax]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2009</year>
<volume>54</volume>
<page-range>764-76</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cano]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Osca]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sancho-Tello]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of effectiveness of right ventricular septal pacing versus right ventricular apical pacing]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>2010</year>
<volume>105</volume>
<page-range>1426-32</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nikoo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ghaedian]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kafi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effects of right ventricular septal versus apical pacing on plasma natriuretic peptide levels]]></article-title>
<source><![CDATA[J Cardiovasc Dis Res]]></source>
<year>2011</year>
<volume>2</volume>
<page-range>104-9</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Man Yu]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Sun Chan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Qing Zhang]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biventricular pacing in patients with bradicardia and normal ejection fraction]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2009</year>
<volume>361</volume>
<page-range>2123-34</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lieberman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Grenz]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Mond]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Selective site pacing: defining and reaching the selected site]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2004</year>
<volume>27</volume>
<page-range>883-6</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Galderisi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cattaneo]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Mondillo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Doppler echocardiography and myocardial dyssynchrony: A practical update of old and new ultrasound technologies]]></article-title>
<source><![CDATA[Cardiovasc Ultrasound]]></source>
<year>2007</year>
<volume>6</volume>
<page-range>5-28</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gorcsan]]></surname>
<given-names><![CDATA[J III]]></given-names>
</name>
<name>
<surname><![CDATA[Abraham]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Agler]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Echocardiography for cardiac resynchronization therapy: recommendations for performance and reporting-a report from the American Society of Echocardiography Dyssynchrony Writing Group endorsed by the Heart Rhythm Society]]></article-title>
<source><![CDATA[J Am Soc Echocardiogr]]></source>
<year>2008</year>
<volume>21</volume>
<page-range>191-213</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schiller]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Crawford]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recommendations for quantitation of the left ventricle by two-dimensional echocardiography]]></article-title>
<source><![CDATA[J Am Soc Echocardiogr]]></source>
<year>1989</year>
<volume>2</volume>
<page-range>358-67</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Sisti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Márquez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Tonet]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adverse effects of long-term right ventricular apical pacing and identification of patients at risk of atrial fibrillation and heart failure]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2012</year>
<volume>35</volume>
<page-range>1035-43</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Inoue]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Okayama]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Nishimura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular septal pacing preserves global left ventricular longitudinal function in comparison with apical pacing]]></article-title>
<source><![CDATA[Circ J]]></source>
<year>2011</year>
<volume>75</volume>
<page-range>1609-15</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alhous]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Small]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hannah]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac function]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2011</year>
<volume>13</volume>
<page-range>1738-46</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Occhetta]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Bortnik]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Magnani]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: A crossover, blinded, randomized study versus apical right ventricular pacing]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2006</year>
<volume>47</volume>
<page-range>1938-45</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Sun]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right ventricular outflow pacing induces less regional wall motion abnormalities in the left ventricle compared with apical pacing]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2012</year>
<volume>14</volume>
<page-range>351-7</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lieberman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Padeletti]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Schreuder]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2006</year>
<volume>48</volume>
<page-range>1634-41</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaye]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Stambler]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Yee]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Search for the optimal right ventricular pacing site: Design and implementation of three randomized multicenter clinical trials]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2009</year>
<volume>32</volume>
<page-range>426-33</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sparks]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Mond]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Vohra]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical remodeling of the atria following loss of atrioventricular synchrony: A long-term study in humans]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1999</year>
<volume>100</volume>
<page-range>1894-900</page-range></nlm-citation>
</ref>
</ref-list>
</back>