<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402009000400007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Predictores clínicos de tormenta arrítmica en pacientes con cardiomiopatía Chagásica con un desfibrilador automático implantable]]></article-title>
<article-title xml:lang="en"><![CDATA[Clinical predictors of ventricular arrhythmia storms in Chagas cardiomyopathy patients with implantable defibrillators]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Flores-Ocampo]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[Santiago]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Márquez]]></surname>
<given-names><![CDATA[Manlio F]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gómez-Flores]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Colín]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[Atala]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Celaya]]></surname>
<given-names><![CDATA[Manuel]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Treviño]]></surname>
<given-names><![CDATA[Ernesto]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González-Hermosillo]]></surname>
<given-names><![CDATA[Jesús Antonio]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Iturralde]]></surname>
<given-names><![CDATA[Pedro]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Nacional de Cardiología Ignacio Chávez Departamento de Electrocardiología ]]></institution>
<addr-line><![CDATA[México D.F]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2009</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2009</year>
</pub-date>
<volume>79</volume>
<numero>4</numero>
<fpage>263</fpage>
<lpage>267</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402009000400007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402009000400007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402009000400007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo. Definir los factores predictivos de la aparición de tormenta arrítmica (TA) en pacientes con Cardiopatía Chagasica Crónica (CCh) portadores de un desfibrilador automático implantable (DAI). Material y métodos. Se estudiaron en forma retrospectiva a 21 pacientes consecutivos con CCh a los cuales se les implantó un DAI entre abril del 2005 y diciembre del 2008, con un seguimiento promedio de 867 días. Los pacientes fueron clasificados en dos grupos de acuerdo con la presencia de episodios de TA. Se compararon características básales, tratamiento médico y determinantes de función ventricular entre ambos grupos. Los valores de p menores de 0.05 se consideraron de significancia estadística. Resultados. En los 21 pacientes con CCh hubo ocho mujeres (37%), la edad promedio fue de 61 años y la fracción de expulsión del ventrículo izquierdo (FEVI) promedio fue de 30%. Se observó por lo menos un episodio de TA en 9 casos (incidencia del 43%). El número total de episodios de TA fue de 13 y el número de arritmias ventriculares en cada episodio de TAfue de 15.6 (intervalo 3 a 61). Sólo en dos casos se identificó un factor desencadenante (proceso infeccioso pulmonar y descompensación de insuficiencia cardiaca crónica). Al analizar los posibles factores predictivos de TA se observó que un mayor porcentaje de sujetos con esta complicación tuvieron una FE < 35% (89% vs 50%; p = 0.01) y una clase funcional III o IV de la NYHA (66% vs 8.3%; p = 0.001). En contraste, un menor porcentaje de sujetos con TA se encontraban en tratamiento con bloqueador beta (55% vs 100%; p = 0.01). Conclusiones. En sujetos con CCh, portadores de un DAI, las siguientes variables son predictivas del desarrollo de TA: FE < 35%, clase funcional III-IV de la NYHA y ausencia de tratamiento con bloqueador beta.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Objectives. To define the predictive factors of electrical storm (ES) in patients with Chronic Chagas Heart Disease (CCh) with an implantable cardioverter defibrillator (ICD). Material and methods. We retrospectively studied 21 consecutive patients with CCh in whom an ICD was implanted between April 2005 and December 2008, with a mean follow up of 867 days. Patients were classified into two groups according to the presence of electrical storm episodes. We compared baseline characteristics, medical treatment and determinants of ventricular function. P values less than 0.05 were considered statistically significant. Results. Of the 21 patients with CCh there were eight women (37%), mean age 61 years and an EF of 30%. It was noted at least one episode of arrhythmic storm in 9 cases (incidence of 43%). The total number of episodes of arrhythmic storm was 13 and the number of ventricular arrhythmias in each episode of arrhythmic storm was 15.6 (range 3-61). A trigger was identified in only two cases (pulmonary infectious process and decompensation of chronic heart failure). After analyzing the possible predictors of arrhythmic storm was found that a greater percentage of subjects with this complication had an EF <35% (89% vs. 50%, p = 0.01) and NYHAfunctional class III (66% vs. 8.3%, p = 0.001). In contrast, a lower percentage of subjects with arrhythmic storm were under beta-blocker treatment (55% vs. 100%, p = 0.01). Conclusions. In subjects with CCh with an ICD, the following variables are predictive of arrhythmic storm: EF <35%, NYHA functional class III-IV and absence of beta-blocker treatment.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Cardiopatía chagasica]]></kwd>
<kwd lng="es"><![CDATA[Arritmias ventriculares malignas]]></kwd>
<kwd lng="es"><![CDATA[Tormenta arrítmica]]></kwd>
<kwd lng="es"><![CDATA[Desfibrilador automático implantable]]></kwd>
<kwd lng="es"><![CDATA[México]]></kwd>
<kwd lng="en"><![CDATA[Chagas disease]]></kwd>
<kwd lng="en"><![CDATA[Malignant ventricular arrhythmias]]></kwd>
<kwd lng="en"><![CDATA[Arrhythmic storm]]></kwd>
<kwd lng="en"><![CDATA[Implantable]]></kwd>
<kwd lng="en"><![CDATA[Cardioverter Defibrillator]]></kwd>
<kwd lng="en"><![CDATA[Mexico]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Investigaci&oacute;n cl&iacute;nica: electrofisiolog&iacute;a y arritmias</font></p>     <p align="justify"><font face="verdana" size="4">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Predictores cl&iacute;nicos de tormenta arr&iacute;tmica en pacientes con cardiomiopat&iacute;a Chag&aacute;sica con un desfibrilador autom&aacute;tico implantable</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="3"><b>Clinical predictors of ventricular arrhythmia storms in Chagas cardiomyopathy patients with implantable defibrillators</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>Jorge Flores&#150;Ocampo, Santiago Nava, Manlio F M&aacute;rquez, Jorge G&oacute;mez&#150;Flores, Luis Col&iacute;n, Atala L&oacute;pez, Manuel Celaya, Ernesto Trevi&ntilde;o, Jes&uacute;s Antonio Gonz&aacute;lez&#150;Hermosillo y Pedro Iturralde</b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i>Departamento de electrocardiolog&iacute;a del Instituto Nacional de Cardiolog&iacute;a Ignacio Ch&aacute;vez, M&eacute;xico, D.F.</i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Correspondencia: </b>    <br>     <i>Santiago Nava.     <br>     Departamento de Electrocardiolog&iacute;a.     <br>     Instituto Nacional de Cardiolog&iacute;a Ignacio Ch&aacute;vez.     <br>     Juan Badiano N&uacute;m. 1. Col. Secci&oacute;n XVI.     <br>     Tlalpan 14800. M&eacute;xico, D.F.    <br> Tel&eacute;fono: (0155) 55732911 Ext. 1218.</i>    <br> Correo electr&oacute;nico: <a href="mailto:santiagonavat@hotmail.com">santiagonavat@hotmail.com</a>.     <br> </font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Recibido el 15 de octubre de 2009.    <br> Aceptado el 10 de noviembre de 2009.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     <p align="justify"><font face="verdana" size="2"><b>Objetivo. </b>Definir los factores predictivos de la aparici&oacute;n de tormenta arr&iacute;tmica (TA) en pacientes con Cardiopat&iacute;a Chagasica Cr&oacute;nica (CCh) portadores de un desfibrilador autom&aacute;tico implantable (DAI). </font></p>     <p align="justify"><font face="verdana" size="2"><b>Material y m&eacute;todos. </b>Se estudiaron en forma retrospectiva a 21 pacientes consecutivos con CCh a los cuales se les implant&oacute; un DAI entre abril del 2005 y diciembre del 2008, con un seguimiento promedio de 867 d&iacute;as. Los pacientes fueron clasificados en dos grupos de acuerdo con la presencia de episodios de TA. Se compararon caracter&iacute;sticas b&aacute;sales, tratamiento m&eacute;dico y determinantes de funci&oacute;n ventricular entre ambos grupos. Los valores de p menores de 0.05 se consideraron de significancia estad&iacute;stica. </font></p>     <p align="justify"><font face="verdana" size="2"><b>Resultados. </b>En los 21 pacientes con CCh hubo ocho mujeres (37%), la edad promedio fue de 61 a&ntilde;os y la fracci&oacute;n de expulsi&oacute;n del ventr&iacute;culo izquierdo (FEVI) promedio fue de 30%. Se observ&oacute; por lo menos un episodio de TA en 9 casos (incidencia del 43%). El n&uacute;mero total de episodios de TA fue de 13 y el n&uacute;mero de arritmias ventriculares en cada episodio de TAfue de 15.6 (intervalo 3 a 61). S&oacute;lo en dos casos se identific&oacute; un factor desencadenante (proceso infeccioso pulmonar y descompensaci&oacute;n de insuficiencia cardiaca cr&oacute;nica). Al analizar los posibles factores predictivos de TA se observ&oacute; que un mayor porcentaje de sujetos con esta complicaci&oacute;n tuvieron una FE &lt; 35% (89% vs 50%; <i>p </i>= 0.01) y una clase funcional III o IV de la NYHA (66% vs 8.3%; <i>p </i>= 0.001). En contraste, un menor porcentaje de sujetos con TA se encontraban en tratamiento con bloqueador beta (55% vs 100%; <i>p </i>= 0.01). </font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusiones. </b>En sujetos con CCh, portadores de un DAI, las siguientes variables son predictivas del desarrollo de TA: FE &lt; 35%, clase funcional III&#150;IV de la NYHA y ausencia de tratamiento con bloqueador beta.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave: </b>Cardiopat&iacute;a chagasica; Arritmias ventriculares malignas; Tormenta arr&iacute;tmica; Desfibrilador autom&aacute;tico implantable; M&eacute;xico.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>     <p align="justify"><font face="verdana" size="2"><b>Objectives. </b>To define the predictive factors of electrical storm (ES) in patients with Chronic Chagas Heart Disease (CCh) with an implantable cardioverter defibrillator (ICD). </font></p>     <p align="justify"><font face="verdana" size="2"><b>Material and methods. </b>We retrospectively studied 21 consecutive patients with CCh in whom an ICD was implanted between April 2005 and December 2008, with a mean follow up of 867 days. Patients were classified into two groups according to the presence of electrical storm episodes. We compared baseline characteristics, medical treatment and determinants of ventricular function. P values less than 0.05 were considered statistically significant. </font></p>     <p align="justify"><font face="verdana" size="2"><b>Results. </b>Of the 21 patients with CCh there were eight women (37%), mean age 61 years and an EF of 30%. It was noted at least one episode of arrhythmic storm in 9 cases (incidence of 43%). The total number of episodes of arrhythmic storm was 13 and the number of ventricular arrhythmias in each episode of arrhythmic storm was 15.6 (range 3&#150;61). A trigger was identified in only two cases (pulmonary infectious process and decompensation of chronic heart failure). After analyzing the possible predictors of arrhythmic storm was found that a greater percentage of subjects with this complication had an EF &lt;35% (89% vs. 50%, <i>p</i> = 0.01) and NYHAfunctional class III (66% vs. 8.3%, <i>p</i> = 0.001). In contrast, a lower percentage of subjects with arrhythmic storm were under beta&#150;blocker treatment (55% vs. 100%, <i>p</i> = 0.01). </font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusions. </b>In subjects with CCh with an ICD, the following variables are predictive of arrhythmic storm: EF &lt;35%, NYHA functional class III&#150;IV and absence of beta&#150;blocker treatment.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Key words: </b>Chagas disease; Malignant ventricular arrhythmias; Arrhythmic storm; Implantable;Cardioverter Defibrillator; Mexico. </font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">La enfermedad de Chagas es una enfermedad parasitaria end&eacute;mica y un problema de salud p&uacute;blica en Latinoam&eacute;rica, en donde hay 18 millones de personas cr&oacute;nicamente infectadas, 200 000 nuevos casos cada a&ntilde;o y 120 millones de personas en riesgo.<sup>1</sup> La principal y m&aacute;s grave afectaci&oacute;n org&aacute;nica de la enfermedad es la cardiopat&iacute;a chag&aacute;sica cr&oacute;nica que se caracteriza por insuficiencia cardiaca (IC), fen&oacute;menos tromboemb&oacute;licos, arritmias y muerte s&uacute;bita (MS).<sup>2&#150;4</sup> La prevalencia de MS en pacientes con CCh var&iacute;a del 29% en &aacute;reas no end&eacute;micas a 37% en &aacute;reas donde la enfermedad es end&eacute;mica, con una incidencia de 5% anual. En poblaciones hospitalarias de pacientes con CCh en centros terciarios de referencia se han determinado prevalencias de 44% con una incidencia anual de 22%.<sup>5</sup><sup>&#150;7</sup></font></p>     <p align="justify"><font face="verdana" size="2">El DAI se ha utilizado para la prevenci&oacute;n primaria y secundaria de MS en esta poblaci&oacute;n. No existen estudios cl&iacute;nicos aleatorios que eval&uacute;en la eficacia y la seguridad del tratamiento de los pacientes con CCh mediante la implantaci&oacute;n de un DAI, por lo que la indicaci&oacute;n actual para implantarlo proviene de la extrapolaci&oacute;n de los resultados de estudios cl&iacute;nicos de pacientes con otras afecciones, como enfermedad arterial coronaria o miocardiopat&iacute;a dilatada idiop&aacute;tica.<sup>8&#150;16</sup></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Recientemente se cuestion&oacute; el beneficio del DAI en pacientes con CCh, se&ntilde;alando que el desfibrilador podr&iacute;a tener un impacto delet&eacute;reo en el pron&oacute;stico cl&iacute;nico del paciente. Se ha observado una alta frecuencia de terapias administradas y est&aacute; demostrado que el n&uacute;mero de &eacute;stas es un predictor poderoso e independiente de mortalidad en estos pacientes, lo que hace pensar que las frecuentes descargas promover&iacute;an y deteriorar&iacute;an la funci&oacute;n ventricular.<sup>17</sup></font></p>     <p align="justify"><font face="verdana" size="2">La existencia de m&uacute;ltiples terapias administradas por el DAI en un corto tiempo (tres o m&aacute;s episodios de taquicardia ventricular (TV) o fibrilaci&oacute;n ventricular (FV) en 24 horas) se define como TA, lo cual constituye una urgencia m&eacute;dica.<sup>18</sup> Esta situaci&oacute;n causa una profunda morbilidad psicol&oacute;gica y deteriora la calidad de vida de los pacientes afectados; adem&aacute;s, existe evidencia de que incrementa la mortalidad general.<sup>18&#150;22</sup> Son muy pocos los estudios en los que se ha analizado el seguimiento y determinado la incidencia de TA en los pacientes con CCh y DAI. El objetivo de este estudio es determinar los factores predictivos de TA en esta poblaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Metodolog&iacute;a</b></font></p>     <p align="justify"><font face="verdana" size="2">Se implantaron desfibriladores autom&aacute;ticos a 21 pacientes consecutivos portadores de CCh de abril del 2005 a diciembre del 2008. Los pacientes se clasificaron en dos grupos de acuerdo con la presencia de episodios de TA. Todos los dispositivos eran de 3a o 4a generaci&oacute;n, 12 unicamerales (57%) y la t&eacute;cnica de implantaci&oacute;n fue endovenosa. Para ser incluidos en el estudio, los pacientes deb&iacute;an tener un resultado serol&oacute;gico positivo para enfermedad de Chagas y ausencia de otras afecciones que pudieran explicar la presencia de enfermedad mioc&aacute;rdica. La ocurrencia de episodios arr&iacute;tmicos, el tipo de arritmia y el tipo de terapia el&eacute;ctrica entregada se revisaron retrospectivamente. Los tipos de arritmias se catalogaron como TV o FV, seg&uacute;n la frecuencia cardiaca, el inicio de la taquicardia y la estabilidad de los intervalos RR, y los tipos de terapias entregadas por los dispositivos se clasificaron como terapia anti&#150;taquicardia (ATP) y cardiodesfibrilaci&oacute;n. Los pacientes tuvieron un seguimiento durante al menos los seis meses siguientes a la implantaci&oacute;n, con por lo menos dos valoraciones posteriores en donde se extrajo la informaci&oacute;n de los dispositivos para obtener los electrogramas almacenados para que los interpretara un m&eacute;dico especialista. La frecuencia de las visitas de seguimiento fue de uno, tres o seis meses, lo cual dependi&oacute; de la condici&oacute;n m&eacute;dica del paciente. La media de seguimiento posterior a la implantaci&oacute;n fue de 867 d&iacute;as (intervalo de 216 a 2 956 d&iacute;as). La presencia de TA se defini&oacute; como m&aacute;s de dos episodios de arritmias ventriculares dentro de un lapso de 24 horas y separados por un periodo de ritmo sinusal (o ritmo basal distinto a la arritmia ventricular) mayor a una hora, definici&oacute;n que ha sido adoptada por las gu&iacute;as internacionales.<sup>17&#150;19</sup> Se compararon las caracter&iacute;sticas b&aacute;sales, el tratamiento m&eacute;dico y los determinantes de funci&oacute;n ventricular en los pacientes con CCh con episodios de TA y sin ellos.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>An&aacute;lisis estad&iacute;stico</b></font></p>     <p align="justify"><font face="verdana" size="2">Los datos fueron almacenados en una base de datos y analizados con el <i>software </i>estad&iacute;stico SPSS en su versi&oacute;n 16 para Windows. El informe de la estad&iacute;stica descriptiva conten&iacute;a medias y desviaciones est&aacute;ndar (o medianas e intervalos para distribuciones asim&eacute;tricas) para las variables continuas, y frecuencias y porcentajes absolutos para variables categ&oacute;ricas. La comparaci&oacute;n entre los grupos se efectu&oacute; con el test <i>t </i>de Student sin parejas de valores y la prueba <i>X<sup>2</sup> </i>seg&uacute;n fuera apropiado. Los valores de <i>p</i> menores de 0.05 fueron considerados de significancia estad&iacute;stica.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resultados</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">El estudio se bas&oacute; en el seguimiento retrospectivo de 21 pacientes consecutivos con diagn&oacute;stico de CCh, a los cuales se les implant&oacute; un DAI. Catorce eran pacientes del g&eacute;nero masculino (62%), con una edad promedio de 61 &plusmn; 9 a&ntilde;os y una FEVI del 30% &plusmn; 12. Siete pacientes (33.3%) tuvieron una FEVI &gt; 35%, y &uacute;nicamente un paciente una FEVI normal. Las comorbilidades m&aacute;s frecuentes fueron HAS, DM tipo 2, obesidad y tabaquismo, en orden de frecuencia. Ning&uacute;n paciente ten&iacute;a documentada enfermedad coronaria asociada y s&oacute;lo un paciente padec&iacute;a insuficiencia renal. El 95% de los pacientes recib&iacute;a amiodarona como parte de su tratamiento m&eacute;dico; al 80% se le administraban bloqueadores beta e inhibidores de la enzima convertidora de angiotensina; el 85% de los individuos tomaba diur&eacute;ticos y ning&uacute;n paciente estaba tratado con estatinas. En 15 pacientes (71.4%) se coloc&oacute; el DAI como medida de prevenci&oacute;n secundaria de MS. En relaci&oacute;n con los criterios de elegibilidad para la implantaci&oacute;n del desfibrilador, el 100% de los pacientes en prevenci&oacute;n primaria cumpl&iacute;a con el criterio de FEVI menor a 35%, 66% extras&iacute;stoles ventriculares frecuentes y 83% episodios documentados de taquicardia ventricular monom&oacute;rfica no sostenida (TVMNS). Mientras que entre los pacientes con indicaci&oacute;n secundaria para prevenci&oacute;n de MS, 14 pacientes (93%) presentaron episodios de taquicardia ventricular sostenida (TVS) y dos pacientes (13.3%) se recuperaron de un episodio de MS (<a href="#t1">Tabla 1</a>).</font></p>     <p align="center"><font face="verdana" size="2"><a name="t1"></a></font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/acm/v79n4/a7t1.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">En 15 pacientes (71.4%) se documentaron terapias adecuadas del dispositivo en respuesta a trastornos arr&iacute;tmicos ventriculares, y en seis pacientes no se documentaron terapias durante el tiempo de seguimiento. Se registr&oacute; un total de 246 episodios de arritmias ventriculares, 16.4 episodios por paciente (intervalo de 1 a 61 episodios/paciente). S&oacute;lo 1.62% de las terapias fue catalogada como inadecuada (cuatro episodios en dos pacientes) que correspondi&oacute; a taquicardias supraventriculares mal discriminadas. En relaci&oacute;n con el tipo de terapia entregada se observ&oacute; que dos pacientes (13.3%) recibieron &uacute;nicamente terapias antitaquicardia (ATP), y 13 pacientes (86.6%) recibieron ATP y cardiodesfibrilaci&oacute;n. La arritmia presentada en 20% de los casos fue taquicardia ventricular sostenida, mientras que en 80% de los pacientes se observaron episodios de TV y FV.</font></p>     <p align="justify"><font face="verdana" size="2">La prevalencia de TA fue de 42.9% (9 pacientes). Se observaron 13 episodios totales de TA, cuatro pacientes presentaron dos, y cinco individuos uno solo. Se registr&oacute; un total de 203 arritmias ventriculares, que form&oacute; parte de los episodios de TA, los cuales representaron 82% del n&uacute;mero total de arritmias ventriculares durante el seguimiento. El promedio de arritmias ventriculares por episodio de TA fue de 15.6 (intervalo 3 a 61). El n&uacute;mero promedio de d&iacute;as posteriores a la implantadon que transcurrieron hasta el episodio de TA fue de 215 d&iacute;as (intervalo 2 a 1 115 d&iacute;as). En relaci&oacute;n con el tipo de arritmias se observ&oacute; que &uacute;nicamente un paciente present&oacute; episodios recurrentes de TV que fueron tratados con ATP de manera exitosa, mientras que el resto de los pacientes (ocho pacientes, 89%) manifestaron episodios de TV refractarios a ATP con degeneraci&oacute;n posterior a FV, que requirieron m&uacute;ltiples descargas. S&oacute;lo en dos padentes (22.2%) se identific&oacute; un posible factor desencadenante, a saber, en un caso, un proceso infeccioso pulmonar, y en otro, una descompensaci&oacute;n aguda de insuficiencia cardiaca (IC). Se requiri&oacute; hospitalizaci&oacute;n en 92% de los casos, y el tratamiento administrado fue revisi&oacute;n del dispositivo, tratamiento antiarr&iacute;tmico intravenoso, En ocho pacientes (89%) se realiz&oacute; un estudio electrofisiol&oacute;gico con ablaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">La FEVI promedio de la totalidad de los pacientes fue de 30% &plusmn; 12%. Adem&aacute;s, siete individuos (33%) tuvieron una FEVI mayor a 35%, y se document&oacute; en este grupo terapias del DAI en 71% del mismo. De los enfermos en los que se documentaron episodios de TA, 89% tuvo una FEVI menor al 35% en comparaci&oacute;n con solamente el 50% en el grupo sin TA (<i>p</i> = 0.001). En los pacientes con TA, el 67% estaba en una clase funcional III&#150;IV de la NYHA, en comparaci&oacute;n con 43% en el grupo sin TA (<i>p</i> = 0.01). Para finalizar, se observ&oacute; que la totalidad de los pacientes sin TA recib&iacute;a tratamiento con bloqueadores beta vs 55% de los pacientes con TA (<i>p</i> = 0.01).</font></p>     <p align="justify"><font face="verdana" size="2">La mortalidad general de la cohorte fue de 23% (cinco pacientes), 22% para los casos con TA (dos), y de 25% para aqu&eacute;llos sin episodios de TA (tres, <i>p</i> = NS). Ninguna de las muertes se consider&oacute; de naturaleza arr&iacute;tmica, tres estuvieron relacionadas con la progresi&oacute;n de la IC, una de naturaleza no cardiaca y una por complicaciones quir&uacute;rgicas.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Discusi&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">La MS cardiaca de origen arr&iacute;tmico es la principal causa de mortalidad en pacientes con CCh, por lo que esta afecci&oacute;n se ha vuelto una reciente indicaci&oacute;n para la implantaci&oacute;n de un DAI.<sup>5&#150;8</sup> Existen series que se&ntilde;alan que los pacientes con CCh evolucionan mal cuando se les implanta un DAI, en comparaci&oacute;n con pacientes con otros tipos de cardiopat&iacute;a.<sup>22</sup> En concordancia con estos estudios, en esta serie se observ&oacute; que un alto porcentaje de pacientes recibi&oacute; terapias posterior al implante (71%), con una cantidad de terapias por paciente mucho mayor al dado a conocer en series de sujetos con cardiopat&iacute;a no&#150;chag&aacute;sica (16 terapias/ pacientes).<sup>23</sup> Adem&aacute;s se observ&oacute; que la mayor parte de las arritmias ventriculares se present&oacute; como parte de los episodios de TA (82%). Conolly y colaboradores analizaron el subgrupo de pacientes con CCh del estudio Canadiense de DAI (CIDS),<sup>15</sup> en el que se determin&oacute; que los pacientes con CCh y un desfibrilador implantado como medida de prevenci&oacute;n secundaria presentaban una primera descarga temprana y ten&iacute;an baja probabilidad de un seguimiento libre de descarga despu&eacute;s de la implantaci&oacute;n. Asimismo se observ&oacute; que una importante proporci&oacute;n de pacientes con FEVI mayor de 35% presentaba descargas apropiadas. Todo esto contrasta con lo informado con respecto a pacientes portadores de Cl.<sup>15</sup> El sustrato tan arritm&oacute;geno observado en los pacientes con CCh se explica por la extensa fibrosis y la cicatrizaci&oacute;n mioc&aacute;rdica, que provocan anisotropismo no uniforme de la conducci&oacute;n y que forman el sustrato para que se produzcan m&uacute;ltiples sitios de reentrada.<sup>24 </sup>Tambi&eacute;n la disfunci&oacute;n auton&oacute;mica, posiblemente mediada por mecanismos inmunitarios, tiene un papel central en la patogenia de la cardiopat&iacute;a chag&aacute;sica y en la g&eacute;nesis de las arritmias ventriculares.<sup>8</sup></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Muratore y colaboradores, en el recientemente publicado Registro Latinoamericano de DAI, que incluy&oacute; 89 pacientes con CCh, informan sobre 42% de terapias apropiadas y una prevalencia de TA de 15.7% durante un seguimiento promedio de 12 &plusmn; 7 meses. La explicaci&oacute;n de la mayor frecuencia determinada en el presente estudio, tanto de terapias apropiadas como de TA, podr&iacute;a ser el mayor deterioro de la funci&oacute;n ventricular de los pacientes de nuestra serie con una FE promedio de 30% &plusmn; 12% en comparaci&oacute;n con 40% &plusmn;11% dada a conocer por este autor, as&iacute; como al tiempo de seguimiento m&aacute;s prolongado (29 vs 12 meses).<sup>25</sup></font></p>     <p align="justify"><font face="verdana" size="2">La incidencia general de TA en pacientes con un DAI implantado oscila entre 10% y 28%, y se asocia con un mayor riesgo de muerte cardiaca no s&uacute;bita.<sup>17</sup> Los factores predictivos de TA no se han definido en pacientes con CCh. En el presente estudio se observ&oacute; que la prevalencia de TA es mucho mayor (42.9%), y requirieron hospitalizaci&oacute;n 92% de los pacientes. Al igual que lo publicado previamente, los desencadenantes de los episodios de TA no fueron evidentes, ya que s&oacute;lo 22% de los pacientes ten&iacute;a un posible factor identificado. Las principales variables que se identifican como predictivas de TA en las publicaciones especializadas son la funci&oacute;n ventricular, la edad y la insuficiencia renal cr&oacute;nica.<sup>18,19</sup> En la presente poblaci&oacute;n se determin&oacute; que los factores asociados con TA en CCh son una FE menor al 35% (89% en aqu&eacute;llos con TA vs 50% sin TA, <i>p</i> = 0.01), una clase funcional III&#150;IV NYHA (67% vs 43%, <i>p</i> = 0.01) y la ausencia de tratamiento con bloqueadores beta (55%vs100%, <i>p</i> = 0.01).</font></p>     <p align="justify"><font face="verdana" size="2">De manera indirecta se observ&oacute; que la mayor&iacute;a de los episodios arr&iacute;tmicos (80%) es compuesta, es decir, hay TV y FV, mientras que &uacute;nicamente 20% corresponde a TV aislada. Al analizar estos grupos se pudo observar que de los episodios arr&iacute;tmicos compuestos (TV/FV), la mayor&iacute;a corresponde a episodios de TV en donde la estimulaci&oacute;n contra la taquicardia no logra revertir&iacute;a, por lo que se agotan las terapias y se pasa a la cardioversi&oacute;n, o bien, en donde la terapia antitaquicardia acelera la TV a la zona de FV y se aplica la desfibrilaci&oacute;n. Tambi&eacute;n se observ&oacute; que a pesar del &eacute;xito inicial de la terapia hay recurrencia temprana de la taquicardia. Estos episodios de TV pueden ser relativamente lentos y, por lo general, son bien tolerados. Entonces surge la interrogante de cu&aacute;l ser&iacute;a la programaci&oacute;n ideal del DAI y si &eacute;sta podr&iacute;a contribuir a una mejor evoluci&oacute;n del paciente con enfermedad de Chagas y DAI implantado.</font></p>     <p align="justify"><font face="verdana" size="2">La principal interrogante cl&iacute;nica por resolver en pacientes con CCh es si el DAI reduce la mortalidad total con un riesgo aceptable de efectos adversos y complicaciones en comparaci&oacute;n con la mejor terapia m&eacute;dica disponible. Cardinalli&#150;Neto demostr&oacute; que el &uacute;nico predictor independiente de mortalidad en pacientes con CCh y DAI era el n&uacute;mero de terapias que entrega el dispositivo,<sup>26,27</sup> y sugiri&oacute; que el DAI podr&iacute;a influir de manera adversa en el curso cl&iacute;nico de los pacientes con CCh porque favorece y exacerba la disfunci&oacute;n ventricular a causa de sus frecuentes descargas, ya que la principal causa de mortalidad en estos pacientes era la IC progresiva, mientras que en el momento del implante del DAI los pacientes se encontraban en clase funcional I NYHA.</font></p>     <p align="justify"><font face="verdana" size="2">La mortalidad general en el grupo de pacientes de este estudio fue de 23%, y en 60% del cual las causas fueron complicaciones relacionadas con insuficiencia cardiaca y el resto se debi&oacute; a complicaciones no arr&iacute;tmicas. No se determinaron diferencias significativas entre los grupos con TA (22%) y aquellos sin TA (25%). Debido al n&uacute;mero reducido de pacientes de esta serie, no se puede asegurar entonces que la TA o el n&uacute;mero de descargas se relacione con deterioro de la IC o mortalidad, sin embargo, Exner y colaboradores demostraron que en pacientes sin enfermedad de Chagas, los que padec&iacute;an TA fallec&iacute;an con mayor frecuencia por IC y no de muerte s&uacute;bita arr&iacute;tmica,<sup>27 </sup>aunque otros autores no han podido confirmar este hallazgo.<sup>18</sup><sup>,19,25</sup> A la fecha, la indicaci&oacute;n del DAI se basa en la extrapolaci&oacute;n de los resultados de estudios cl&iacute;nicos en pacientes con cardiopat&iacute;a no&#150;chag&aacute;sica. No obstante, est&aacute; demostrado que son diferentes las caracter&iacute;sticas y el comportamiento de los pacientes con CCh. Es de suma importancia contar entonces con estudios cl&iacute;nicos y aleatorios para la toma de decisiones en relaci&oacute;n con la eficacia y seguridad del DAI en los pacientes con CCh.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusiones</b></font></p>     <p align="justify"><font face="verdana" size="2">La prevalencia de los episodios de TA en pacientes con CCh es alta. Los factores determinantes del estado funcional del mioc&aacute;rdico como la FEVI y el estado cl&iacute;nico del paciente (clase NYHA), as&iacute; como la ausencia de tratamiento con bloqueadores beta son los principales factores predictivos de la presencia de TA.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Bibliograf&iacute;a</b></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">1. Guzm&aacute;n&#150;Bracho C. Epidemiology of Chagas disease in Mexico: an update. Trends Parasitol 2001;17(8):372&#150;376.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083066&pid=S1405-9940200900040000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">2. Ramos JL, Muratore C, Pach&oacute;n&#150;Mateos JC, Rodr&iacute;guez A, Gonz&aacute;lez&#150;Hermosillo A, Asenjo R et al. Prevenci&oacute;n primaria y secundaria de muerte s&uacute;bita en el ICD Registry Latin America. Arch Cardiol Mex 2008;78:400&#150;406.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083067&pid=S1405-9940200900040000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">3. Punukollu G, Gowda RM, Khan IA. Early twentieth century descriptions of the Chagas heart disease. Int J Cardiol 2004;95(2&#150;3): 347&#150;349.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083068&pid=S1405-9940200900040000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">4. Marin&#150;Neto   JA,   Cunha&#150;Neto   E,   Maciel   BC,   Sim&oacute;es   MV. Pathogenesis of chronic Chagas heart disease. Circulation 2007;115(9):1109&#150;1123.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083069&pid=S1405-9940200900040000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">5. Rassi A Jr, Rassi A, Rassi SG. Predictors of mortality in chronic Chagas disease: a systematic review of observational studies. Circulation 2007;115(9):1101 &#150;1108.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083070&pid=S1405-9940200900040000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">6. Rassi A Jr, Rassi A, Little WC, Xavier SS, Rassi SG, Rassi AG, et al. Development and validation of a risk score for predicting death in Chagas' heart disease. N Engl J Med 2006;355(8):799&#150;808.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083071&pid=S1405-9940200900040000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">7. Baroldi G, Oliveira SJ, Silver MD. Sudden and unexpected death in clinically 'silent' Chagas' disease. A hypothesis. Int J Cardiol 1997;58(3):263&#150;268.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083072&pid=S1405-9940200900040000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">8. Bestetti RB, Cardinalli&#150;Neto A. Sudden cardiac death in Chagas'  heart disease in the contemporary era.   Int J Cardiol 2008;131(1):9&#150;17.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083073&pid=S1405-9940200900040000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">9. Iturralde TP. Estado actual del desfibrilador cardioverter implantable. Arch Cardiol Mex 2002;72 Supl.1 :s86&#150;s90.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083074&pid=S1405-9940200900040000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">10. Mendoza C. Utilidad del desfibrilador autom&aacute;tico implantable en la prevenci&oacute;n de muerte s&uacute;bita. Resultados de la medicina basada en evidencia. Arch Cardiol Mex 2007;Supl 2: 44&#150;46.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083075&pid=S1405-9940200900040000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">11. DiMarco JP. Implantable cardioverter&#150;defibrillators. N Engl J Med 2003;349(19):1836&#150;1847.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083076&pid=S1405-9940200900040000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">12. McAnulty J, Halperin B, Larsen KG. Acomparison of antiarrhythmic&#150;drug therapy with implantable defibrillators in patients resuscitated from near&#150;fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. N Engl J Med 1997;337(22):1621&#150;1623.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083077&pid=S1405-9940200900040000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">13. Kuck KH, Cappato R, Siebels J, R&uuml;ppel R. Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest: the Cardiac Arrest Study Hamburg (CASH). Circulation 2000;102(7):748&#150;754.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083078&pid=S1405-9940200900040000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">14. Sheldon R, Connolly S, Krahn A, Roberts R, Gent M, Gardner M. Identification of patients most likely to benefit from implantable cardioverter&#150;defibrillator therapy: the Canadian Implantable Defibrillator Study. Circulation 2000;101 (14):1660&#150;1664.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083079&pid=S1405-9940200900040000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">15. Connolly SJ, Hallstrom AP, Cappato R, Schron EB, Kuck KH, Zipes DP, et al. Meta&#150;analysis of the implantable cardioverter defibrillator secondary prevention trials. AVID, CASH and CIDS studies. Antiarrhythmics vs Implantable Defibrillator study. Cardiac Arrest Study Hamburg. Canadian Implantable Defibrillator Study. Eur Heart J 2000;21 (24):2071 &#150;2078.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083080&pid=S1405-9940200900040000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">16. Kadish A, Dyer A, Daubert JP, Quigg R, Estes NA, Anderson KP, et al.  Prophylactic defibrillator implantation in patients with   nonischemic   dilated   cardiomyopathy.   N   Engl   J   Med 2004;350(21 ):2151 &#150;2158.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083081&pid=S1405-9940200900040000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">17. Exner DV, Pinski SL, Wyse DG, Renfroe EG, Follmann D, Gold M, et al. Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial. Circulation 2001;103(16):2066&#150;2071.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083082&pid=S1405-9940200900040000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">18. Credner SC, Klingenheben T, Mauss O, Sticherling C, Hohnloser SH. Electrical storm in patients with transvenous implantable cardioverter&#150;defibrillators: incidence, management and prognostic implications. J Am Coll Cardiol 1998;32(7):1909&#150;1915.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083083&pid=S1405-9940200900040000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">19. Brigadeau F, Kouakam C, Klug D, Marqui&eacute; C, Duhamel A, Mizon&#150;G&eacute;rard F, et al. Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators. Eur Heart J 2006;27(6):700&#150;707.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083084&pid=S1405-9940200900040000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">20. Hohnloser SH, Al&#150;Khalidi HR, Pratt CM, Brum JM, Tatla DS, Tchou P,  et al.  Electrical storm in patients with an implantable  defibrillator:   incidence,   features,   and   preventive therapy: insights from a randomized trial. Eur Heart J 2006;27(24):3027&#150;3032.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083085&pid=S1405-9940200900040000700020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">21. Carbucicchio C, Santamar&iacute;a M, Trevisi N, Maccabelli G, Giraldi F, Fassini G, et al. Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter&#150;defibrillators: short&#150;and long&#150;term outcomes in a prospective single&#150;center study. Circulation 2008;117(4):462&#150;469.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083086&pid=S1405-9940200900040000700021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">22. Muratore C, Rabinovich R, Iglesias R, Gonz&aacute;lez M, Dar&uacute; V, Liprandi AS. Implantable cardioverter defibrillators in patients with Chagas' disease: are they different from patients with coronary disease? Pacing Clin Electrophysiol 1997;20:194&#150;197.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083087&pid=S1405-9940200900040000700022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">23. Rabinovich R, Muratore C, Iglesias R, Gonzalez M, Dar&uacute; V, Valentino M, et al. Time to first shock in implantable cardioverter defibrillator (ICD) patients with Chagas cardiomyopathy. Pacing Clin Electrophysiol 1999;22:202&#150;205.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083088&pid=S1405-9940200900040000700023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">24. Micheli A, Aranda A, Iturralde P, Medrano A. En torno a las arritmias ventriculares en la miocardiopat&iacute;a chag&aacute;sica cr&oacute;nica. Arch Cardiol Mex 2006;76(3):320&#150;323.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083089&pid=S1405-9940200900040000700024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">25. Muratore CA, Batista Sa LA, Chiale PA, Eloy R, Tentori MC, Escudero J et al. Implantable cardioverter defibrillators and Chagas' disease: results of the ICD Registry Latin America. Europace 2009;11:164&#150;168.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083090&pid=S1405-9940200900040000700025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">26. Cardinalli&#150;Neto A, Greco OT, Bestetti RB. Automatic implantable cardioverter&#150;defibrillators in Chagas' heart disease patients with malignant ventricular arrhythmias. Pacing Clin Electrophysiol 2006;29:467&#150;470.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083091&pid=S1405-9940200900040000700026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">27. Cardinalli&#150;Neto A, Bestetti RB, Cordeiro JA, Rodrigues VC. Predictors of all&#150;cause mortality for patients with chronic Chagas' heart disease receiving implantable cardioverter defibrillator therapy. J Cardiovasc Electrophysiol 2007;18(12):1236&#150;1240.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1083092&pid=S1405-9940200900040000700027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guzmán-Bracho]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Epidemiology of Chagas disease in Mexico: an update]]></article-title>
<source><![CDATA[Trends Parasitol]]></source>
<year>2001</year>
<volume>17</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>372-376</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Pachón-Mateos]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[González-Hermosillo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Asenjo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Prevención primaria y secundaria de muerte súbita en el ICD Registry Latin America]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2008</year>
<volume>78</volume>
<page-range>400-406</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Punukollu]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Gowda]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[IA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Early twentieth century descriptions of the Chagas heart disease]]></article-title>
<source><![CDATA[Int J Cardiol]]></source>
<year>2004</year>
<volume>95</volume>
<numero>2-3</numero>
<issue>2-3</issue>
<page-range>347-349</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marin-Neto]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Cunha-Neto]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Maciel]]></surname>
<given-names><![CDATA[BC]]></given-names>
</name>
<name>
<surname><![CDATA[Simóes]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pathogenesis of chronic Chagas heart disease]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2007</year>
<volume>115</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1109-1123</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Predictors of mortality in chronic Chagas disease: a systematic review of observational studies]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2007</year>
<volume>115</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1101 -1108</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Little]]></surname>
<given-names><![CDATA[WC]]></given-names>
</name>
<name>
<surname><![CDATA[Xavier]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Rassi]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development and validation of a risk score for predicting death in Chagas' heart disease]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2006</year>
<volume>355</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>799-808</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baroldi]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Silver]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sudden and unexpected death in clinically 'silent' Chagas' disease. A hypothesis]]></article-title>
<source><![CDATA[Int J Cardiol]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bestetti]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Cardinalli-Neto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sudden cardiac death in Chagas' heart disease in the contemporary era]]></article-title>
<source><![CDATA[Int J Cardiol]]></source>
<year>2008</year>
<volume>131</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>9-17</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Iturralde]]></surname>
<given-names><![CDATA[TP]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estado actual del desfibrilador cardioverter implantable]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2002</year>
<volume>72</volume>
<numero>^sSupl.1</numero>
<issue>^sSupl.1</issue>
<supplement>Supl.1</supplement>
<page-range>s86-s90</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mendoza]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilidad del desfibrilador automático implantable en la prevención de muerte súbita: Resultados de la medicina basada en evidencia]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2007</year>
<numero>^sSupl 2</numero>
<issue>^sSupl 2</issue>
<supplement>Supl 2</supplement>
<page-range>44-46</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[DiMarco]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Implantable cardioverter-defibrillators]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2003</year>
<volume>349</volume>
<numero>19</numero>
<issue>19</issue>
<page-range>1836-1847</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McAnulty]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Halperin]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Larsen]]></surname>
<given-names><![CDATA[KG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Acomparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1997</year>
<volume>337</volume>
<numero>22</numero>
<issue>22</issue>
<page-range>1621-1623</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuck]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Cappato]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Siebels]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rüppel]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest: the Cardiac Arrest Study Hamburg (CASH)]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<volume>102</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>748-754</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sheldon]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Connolly]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Krahn]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Roberts]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gent]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gardner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Identification of patients most likely to benefit from implantable cardioverter-defibrillator therapy: the Canadian Implantable Defibrillator Study]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<volume>101</volume>
<numero>14</numero>
<issue>14</issue>
<page-range>1660-1664</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Connolly]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hallstrom]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[Cappato]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Schron]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Kuck]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Zipes]]></surname>
<given-names><![CDATA[DP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials: AVID, CASH and CIDS studies. Antiarrhythmics vs Implantable Defibrillator study. Cardiac Arrest Study Hamburg. Canadian Implantable Defibrillator Study]]></article-title>
<source><![CDATA[Eur Heart J]]></source>
<year>2000</year>
<volume>21</volume>
<numero>24</numero>
<issue>24</issue>
<page-range>2071 -2078</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kadish]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Dyer]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Daubert]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Quigg]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Estes]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2004</year>
<volume>350</volume>
<numero>21</numero>
<issue>21</issue>
<page-range>2151 -2158</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Exner]]></surname>
<given-names><![CDATA[DV]]></given-names>
</name>
<name>
<surname><![CDATA[Pinski]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
<name>
<surname><![CDATA[Wyse]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
<name>
<surname><![CDATA[Renfroe]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
<name>
<surname><![CDATA[Follmann]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gold]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2001</year>
<volume>103</volume>
<numero>16</numero>
<issue>16</issue>
<page-range>2066-2071</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Credner]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Klingenheben]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Mauss]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Sticherling]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hohnloser]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical storm in patients with transvenous implantable cardioverter-defibrillators: incidence, management and prognostic implications]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1998</year>
<volume>32</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1909-1915</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brigadeau]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kouakam]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Klug]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Marquié]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Duhamel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mizon-Gérard]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators]]></article-title>
<source><![CDATA[Eur Heart J]]></source>
<year>2006</year>
<volume>27</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>700-707</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hohnloser]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Khalidi]]></surname>
<given-names><![CDATA[HR]]></given-names>
</name>
<name>
<surname><![CDATA[Pratt]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Brum]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Tatla]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Tchou]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrical storm in patients with an implantable defibrillator: incidence, features, and preventive therapy: insights from a randomized trial]]></article-title>
<source><![CDATA[Eur Heart J]]></source>
<year>2006</year>
<volume>27</volume>
<numero>24</numero>
<issue>24</issue>
<page-range>3027-3032</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carbucicchio]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Santamaría]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Trevisi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Maccabelli]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Giraldi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fassini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short-and long-term outcomes in a prospective single-center study]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2008</year>
<volume>117</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>462-469</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rabinovich]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Iglesias]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Darú]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Liprandi]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantable cardioverter defibrillators in patients with Chagas' disease: are they different from patients with coronary disease?]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1997</year>
<volume>20</volume>
<page-range>194-197</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rabinovich]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Iglesias]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzalez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Darú]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Valentino]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Time to first shock in implantable cardioverter defibrillator (ICD) patients with Chagas cardiomyopathy]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1999</year>
<volume>22</volume>
<page-range>202-205</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Micheli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Aranda]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Iturralde]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Medrano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[En torno a las arritmias ventriculares en la miocardiopatía chagásica crónica]]></article-title>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2006</year>
<volume>76</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>320-323</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muratore]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Batista Sa]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Chiale]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Eloy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tentori]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Escudero]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantable cardioverter defibrillators and Chagas' disease: results of the ICD Registry Latin America]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2009</year>
<volume>11</volume>
<page-range>164-168</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cardinalli-Neto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Greco]]></surname>
<given-names><![CDATA[OT]]></given-names>
</name>
<name>
<surname><![CDATA[Bestetti]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Automatic implantable cardioverter-defibrillators in Chagas' heart disease patients with malignant ventricular arrhythmia]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>467-470</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cardinalli-Neto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bestetti]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Cordeiro]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Rodrigues]]></surname>
<given-names><![CDATA[VC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Predictors of all-cause mortality for patients with chronic Chagas' heart disease receiving implantable cardioverter defibrillator therapy]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2007</year>
<volume>18</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1236-1240</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
