<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402005000300004</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Aplicaciones del stent cubierto con membrana de politetrafluoroetileno en el intervencionismo coronario (Experiencia del Instituto Nacional de Cardiología "Ignacio Chávez")]]></article-title>
<article-title xml:lang="en"><![CDATA[Synthetic membrane coronary stent graft in coronary disease]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Villavicencio Fernández]]></surname>
<given-names><![CDATA[Ramón]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García Hernández]]></surname>
<given-names><![CDATA[Enrique]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Eid Lidt]]></surname>
<given-names><![CDATA[Guering]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Peña Duque]]></surname>
<given-names><![CDATA[Marco A]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gaspar Hernández]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Nacional de Cardiología Departamento de Cardiología Intervencionista ]]></institution>
<addr-line><![CDATA[México, D.F ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2005</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2005</year>
</pub-date>
<volume>75</volume>
<numero>3</numero>
<fpage>267</fpage>
<lpage>278</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402005000300004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402005000300004&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402005000300004&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El stent cubierto con membrana se ha reportado como un dispositivo útil para corregir lesiones angiográficas específicas, así como complicaciones potenciales secundarias a procedimientos de intervencionismo coronario. El stent cubierto con membrana de (Jostent-Jomed) está compuesto por una fina capa de politetrafluoroetileno (PTFE) que se localiza entre dos stents metálicos. En esta revisión retrospectiva el stent de PTFE se utilizó en varias lesiones y situaciones angiográficas tanto en arterias coronarias como en injertos venosos. Nuestra experiencia consistió de 17 pacientes que fueron tratados por diferentes indicaciones clínicas y angiográficas: perforación coronaria en dos pacientes (pts), injertos venosos con trombo y cambios degenerativos en ocho (pts), aneurismas coronarios en 4 (pts) y trombo grande refractario a tratamiento habitual en otros 3 casos. Nuestros resultados con el stent de PTFE mostraron una tasa de éxito clínico del 100% sin complicaciones durante la fase hospitalaria y en el seguimiento clínico a 10 ± 3 meses sólo tres pacientes tuvieron algún evento cardíaco adverso mayor. La indicación potencial para el implante del stent de PTFE en injertos venosos todavía no se ha puntualizado; sin embargo a la luz de varios estudios pareciera haber poco beneficio en esta circunstancia. Por otro lado la perforación y el aneurisma coronario parecen ser las indicaciones más recomendables para la aplicación de este dispositivo.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Summary The use of a synthetic membrane-covered stent has been suggested to overcome some specific lesions in coronary arteries and to solve some potential complications that could arise in any procedure of coronary intervention. A synthetic membrane coronary stent graft (JOSTENT-JOMED) is constituted by a membrane of polytetrafluoroethylene (PTFE), fixed between two thin metallic stents. In this clinical review of our laboratory's experience, the Jostent graft was used in several angiographic circumstances in coronary arteries or in vein grafts. Our clinical experience consists of 17 patients that were treated with placement of PTFE stents for different indications: coronary rupture in two patients; thrombus and degenerative vein grafts in eight patients, coronary aneurysms in four patients, and thrombus in coronary arteries in three more. Our clinical results with this device suggest that its implant is feasible and safe with a clinical success of 100% without complications during in-hospital stay; during the clinical 11 ± 3 months follow-up, only three patients exhibited major cardiac events. The indication for PTFE stent in vein grafts with degenerative and thrombus lesions has not been determined yet; however, recently, some randomized trials have shown little benefit in this circumstance. On the other side, coronary vessel rupture and coronary aneurysms are currently the most definitive indications.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Injerto stent coronario]]></kwd>
<kwd lng="es"><![CDATA[Stent cubierto]]></kwd>
<kwd lng="es"><![CDATA[Stent de PTFE]]></kwd>
<kwd lng="en"><![CDATA[Coronary stent graft]]></kwd>
<kwd lng="en"><![CDATA[Covered stent]]></kwd>
<kwd lng="en"><![CDATA[PTFE stent]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Investigaci&oacute;n cl&iacute;nica</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b><i>Aplicaciones del stent cubierto con membrana de politetrafluoroetileno en el intervencionismo coronario (Experiencia del Instituto Nacional de Cardiolog&iacute;a "Ignacio Ch&aacute;vez")</i></b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="3"><b>Synthetic membrane coronary stent graft in coronary disease</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>Ram&oacute;n Villavicencio Fern&aacute;ndez, Enrique Garc&iacute;a Hern&aacute;ndez,* Guering Eid Lidt, Marco A Pe&ntilde;a Duque, Jorge Gaspar Hern&aacute;ndez</b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i>* M&eacute;dico ex&#150;residente del Departamento de Cardiolog&iacute;a Intervencionista del Instituto Nacional de Cardiolog&iacute;a.</i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Correspondencia:</b>    <br>   <i>Instituto Nacional de Cardiolog&iacute;a.    <br>   (INCICH, Juan Badiano No. 1, Col. Secci&oacute;n XVI, Tlalpan 14080 M&eacute;xico, D.F).    <br>   Departamento de Cardiolog&iacute;a Intervencionista.    <br>   E&#150;mail: <a href="mailto:ramonvillavicencio@prodigy.net.mx">ramonvillavicencio@prodigy.net.mx</a></i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">Recibido: 16 de febrero de 2005    <br> Aceptado: 2 de agosto de 2005</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">El stent cubierto con membrana se ha reportado como un dispositivo &uacute;til para corregir lesiones angiogr&aacute;ficas espec&iacute;ficas, as&iacute; como complicaciones potenciales secundarias a procedimientos de intervencionismo coronario. El stent cubierto con membrana de (Jostent&#150;Jomed) est&aacute; compuesto por una fina capa de politetrafluoroetileno (PTFE) que se localiza entre dos stents met&aacute;licos. En esta revisi&oacute;n retrospectiva el stent de PTFE se utiliz&oacute; en varias lesiones y situaciones angiogr&aacute;ficas tanto en arterias coronarias como en injertos venosos. Nuestra experiencia consisti&oacute; de 17 pacientes que fueron tratados por diferentes indicaciones cl&iacute;nicas y angiogr&aacute;ficas: perforaci&oacute;n coronaria en dos pacientes (pts), injertos venosos con trombo y cambios degenerativos en ocho (pts), aneurismas coronarios en 4 (pts) y trombo grande refractario a tratamiento habitual en otros 3 casos. Nuestros resultados con el stent de PTFE mostraron una tasa de &eacute;xito cl&iacute;nico del 100% sin complicaciones durante la fase hospitalaria y en el seguimiento cl&iacute;nico a 10 &plusmn; 3 meses s&oacute;lo tres pacientes tuvieron alg&uacute;n evento card&iacute;aco adverso mayor. La indicaci&oacute;n potencial para el implante del stent de PTFE en injertos venosos todav&iacute;a no se ha puntualizado; sin embargo a la luz de varios estudios pareciera haber poco beneficio en esta circunstancia. Por otro lado la perforaci&oacute;n y el aneurisma coronario parecen ser las indicaciones m&aacute;s recomendables para la aplicaci&oacute;n de este dispositivo.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave: </b>Injerto stent coronario. Stent cubierto. Stent de PTFE.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Summary</b></font></p>     <p align="justify"><font face="verdana" size="2">The use of a synthetic membrane&#150;covered stent has been suggested to overcome some specific lesions in coronary arteries and to solve some potential complications that could arise in any procedure of coronary intervention. A synthetic membrane coronary stent graft (JOSTENT&#150;JOMED) is constituted by a membrane of polytetrafluoroethylene (PTFE), fixed between two thin metallic stents. In this clinical review of our laboratory's experience, the Jostent graft was used in several angiographic circumstances in coronary arteries or in vein grafts. Our clinical experience consists of 17 patients that were treated with placement of PTFE stents for different indications: coronary rupture in two patients; thrombus and degenerative vein grafts in eight patients, coronary aneurysms in four patients, and thrombus in coronary arteries in three more. Our clinical results with this device suggest that its implant is feasible and safe with a clinical success of 100% without complications during in&#150;hospital stay; during the clinical 11 &plusmn; 3 months follow&#150;up, only three patients exhibited major cardiac events. The indication for PTFE stent in vein grafts with degenerative and thrombus lesions has not been determined yet; however, recently, some randomized trials have shown little benefit in this circumstance. On the other side, coronary vessel rupture and coronary aneurysms are currently the most definitive indications.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Key words: </b>Coronary stent graft. Covered stent. PTFE stent.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">El stent coronario en la d&eacute;cada de los noventa ha constituido un avance que revolucion&oacute; el tratamiento endovascular coronario que durante los a&ntilde;os ochenta fue el cat&eacute;ter bal&oacute;n. Su beneficio ha sido el de reducir o corregir algunas de las limitaciones inherentes a la angioplast&iacute;a coronaria convencional con bal&oacute;n. De tal suerte esta f&eacute;rula met&aacute;lica proporciona un "andamiaje" que otorga una tensi&oacute;n radial suficiente para expandir la pared vascular evitando la remodelaci&oacute;n vascular negativa y disminuyendo la posibilidad de reestenosis. La evoluci&oacute;n tecnol&oacute;gica del stent ha permitido que este dispositivo no s&oacute;lo sea usado como una f&eacute;rula inerte, sino que tambi&eacute;n en su estructura puedan incorporarse membranas sint&eacute;ticas o biol&oacute;gicas que recubran al stent y que sean elaboradas de material inorg&aacute;nico como es el politetrafluoroetileno (PTFE) o bien de material org&aacute;nico de tejido aut&oacute;logo de vena y/o arteria o de pericardio bovino y que funcionen como una barrera f&iacute;sica para el tratamiento de lesiones tromb&oacute;ticas en injertos venosos, as&iacute; como para la correcci&oacute;n de aneurismas coronarios o de perforaciones del lecho coronario por traumatismo endovascular.</font></p>     <p align="justify"><font face="verdana" size="2">En esta revisi&oacute;n retrospectiva el objetivo principal fue evaluar la factibilidad del stent de PTFE en diversas situaciones o complicaciones angiogr&aacute;ficas (injertos venosos con trombo, aneurismas coronarios, perforaci&oacute;n coronaria y trombo grande "refractario" en arterias coronarias nativas). Por otro lado se analiz&oacute; la tasa de eventos card&iacute;acos adversos mayores en la fase hospitalaria y durante la evoluci&oacute;n cl&iacute;nica a largo plazo.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Material y m&eacute;todos</b></font></p>     <p align="justify"><font face="verdana" size="2">Caracter&iacute;sticas cl&iacute;nicas y angiogr&aacute;ficas De junio de 2000 a febrero de 2003 en nuestra instituci&oacute;n se implantaron 18 stents de PTFE en 17 pacientes en diversas condiciones cl&iacute;nicas y angiogr&aacute;ficas (injertos venosos con cambios degenerativos, aneurismas en arterias coronarias, perforaci&oacute;n coronaria y trombo coronario en arterias coronarias nativas).</font></p>     <p align="justify"><font face="verdana" size="2">Doce pacientes fueron del sexo masculino y cinco del sexo femenino con edad promedio de 57 &plusmn;15 a&ntilde;os. La <i>indicaci&oacute;n cl&iacute;nica </i>motivo del implante del stent cubierto fue por angor estable en 4 pacientes, angor inestable en 8, infarto agudo del miocardio en 3 y en angor postinfarto en otros dos. La <i>indicaci&oacute;n angiogr&aacute;fica </i>en ocho pacientes fue por lesiones con cambios degenerativos y friables en injertos venosos (seis de ellos con trombo asociado); en otros cuatro por aneurisma en arterias coronarias, en dos casos por perforaci&oacute;n coronaria causada por aterectom&iacute;a rotacional y por cat&eacute;ter X&#150;Sizer y en los otros tres por trombo grande "refractario" al abordaje terap&eacute;utico que habitualmente se lleva a cabo en nuestro laboratorio. Las caracter&iacute;sticas angiogr&aacute;ficas del tipo de lesiones abordadas con stent cubierto se resumen en la <a href="#t1">Tabla I</a><i>. </i>Las lesiones seleccionadas para ser tratadas con stent de PTFE ten&iacute;an que presentar tortuosidad leve a moderada en el segmento vascular previo a la lesi&oacute;n y en las arterias coronarias nativas no deber&iacute;a de haber preferentemente ramos laterales grandes que se originaran en el trayecto del segmento vascular donde se posicionara el stent.</font></p>     <p align="center"><font face="verdana" size="2"><a name="t1"></a></font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/acm/v75n3/a04t1.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Caracter&iacute;sticas del stent y del procedimiento</b></font></p>     <p align="justify"><font face="verdana" size="2">El stent cubierto con PTFE (Jomed, Rangendingen, Germany) es una endopr&oacute;tesis expandible con bal&oacute;n y que consiste de dos stents de acero inoxidable que comparten el mismo dise&ntilde;o del Jostent Flex s&oacute;lo que el grosor de los postes met&aacute;licos es m&aacute;s reducido.<sup>1</sup> Entre ambos stents y a manera de "sandwich" se fija una capa microporosa ultradelgada de 75 mieras de espesor con material sint&eacute;tico de politetrafluoroetileno, las porciones distales de ambos stents empalmados sobresalen de la membrana de PTFE dos mil&iacute;metros en cada extremo, ya que ambas estructuras met&aacute;licas de cada stent est&aacute;n fijos en los bordes por medio de una soldadura <a href="#f1">(Fig. 1)</a><i>. </i>El stent cubierto se encuentra disponible en longitudes de 9, 12, 16, 19 y 26 mm y tiene una capacidad de ser expandido con bal&oacute;n hasta un di&aacute;metro m&aacute;ximo de 5 mm. La primera generaci&oacute;n de stents con PTFE, que se utiliz&oacute; en la mayor&iacute;a de nuestros pacientes (13 casos) fue el stent desmontable que ten&iacute;a que ser montado y comprimido manualmente sobre el bal&oacute;n que lo transporta hacia el sitio de la lesi&oacute;n. El cat&eacute;ter bal&oacute;n de tipo "semi&#150;complaciente" fue el que se utiliz&oacute; en todos los casos para montar el stent cubierto y en la mayor&iacute;a de ellos, antes de montar el stent era necesario insuflar transitoriamente el bal&oacute;n a presi&oacute;n de 1 atm&oacute;sfera y a continuaci&oacute;n dejar el insuflador en presi&oacute;n neutra con el objeto de favorecer que el pl&aacute;stico del bal&oacute;n se "hale" y de tal forma el stent se sujete y se fije de una manera m&aacute;s &oacute;ptima cuando es montado y comprimido manualmente sobre el bal&oacute;n. El cat&eacute;ter bal&oacute;n montado con el stent es compatible con cat&eacute;ter gu&iacute;a 7F de "alto flujo" (<u>&gt;</u> 0.78" ). En todos los casos se efectuaron presiones atmosf&eacute;ricas mayor de 13 atm&oacute;sferas para la impactaci&oacute;n del stent. En los &uacute;ltimos cinco pacientes se utiliz&oacute; la segunda generaci&oacute;n de stents de PTFE (montados sobre el bal&oacute;n), lo que favoreci&oacute; un tiempo m&aacute;s corto del procedimiento y un perfil de cruce m&aacute;s reducido.</font></p>     <p align="center"><font face="verdana" size="2"><a name="f1"></a></font></p>     ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><img src="/img/revistas/acm/v75n3/a04f1.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">Todos los pacientes recibieron &aacute;cido acetilsalic&iacute;lico por lo menos 3 d&iacute;as antes del implante del stent y todos recibieron 300 mg de clopidogrel v&iacute;a oral al inicio del procedimiento. F&aacute;rmacos inhibidores IIb&#150;IIIa se administraron en 11 enfermos (en el grupo total de enfermos tratados en injertos venosos, as&iacute; como en tres casos con aneurisma coronario). Los introductores arteriales fueron retirados en todos los casos 12 h despu&eacute;s de finalizado el procedimiento. En los primeros 10 casos se indic&oacute; antiagregaci&oacute;n plaquetaria con clopidogrel por un per&iacute;odo de 8 semanas y en los &uacute;ltimos siete la indicaci&oacute;n del clopidogrel se extendi&oacute; a 6 meses. El seguimiento cl&iacute;nico promedio fue de 10 &plusmn; 3 meses en todos los pacientes y se llev&oacute; a cabo a trav&eacute;s de la consulta externa de nuestra instituci&oacute;n o en su defecto por contacto telef&oacute;nico.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><b>Definiciones:</b></font></p>     <p align="justify"><font face="verdana" size="2"><i>Injertos venosos con cambios degenerativos </i>se consideraron a aquellos injertos con afecci&oacute;n difusa por enfermedad ateroescler&oacute;tica, asociado a "defectos de llenado" intraluminal. <i>Embolizaci&oacute;n distal </i>se defini&oacute; como la "amputaci&oacute;n" angiogr&aacute;fica de un vaso o ramo distal durante cualquier momento del procedimiento y/o bien la presencia de flujo disminuido en un vaso distal que previamente se encontraba permeable en la ausencia de oclusi&oacute;n en el sitio de la lesi&oacute;n "blanco" a tratar.<sup>2</sup> <i>Trombo "definido" </i>se refiere a la presencia de un defecto de llenado con tinci&oacute;n o retenci&oacute;n de material de contraste en por lo menos tres proyecciones ortogonales.<sup>3</sup> <i>Trombo "grande " </i>se consider&oacute; aquel trombo con di&aacute;metro <u>&gt;</u> 2 veces al di&aacute;metro vascular de referencia. Aneurisma coronario se defini&oacute; como una dilataci&oacute;n sacular con un di&aacute;metro mayor a 1.5 veces al di&aacute;metro vascular de referencia.<sup>4</sup> <i>La perforaci&oacute;n coronaria </i>se defini&oacute; seg&uacute;n la clasificaci&oacute;n de Ellis.<sup>5</sup> <i>Trombo "refractario " </i>se consider&oacute; a aquel trombo que no ten&iacute;a mejor&iacute;a angiogr&aacute;fica con el uso de dispositivos de trombectom&iacute;ay aspiraci&oacute;n que habitualmente se utilizaban en ese per&iacute;odo de estudio en nuestro laboratorio (cat&eacute;ter X&#150;Sizer y/o bien dilataci&oacute;n conjunta con cat&eacute;ter bal&oacute;n); adem&aacute;s de que aquellos casos con angina inestable con demostraci&oacute;n angiogr&aacute;fica de trombo hubieran completado una infusi&oacute;n parenteral de inhibidores IIb&#150;IIIa por lapso de 24 a 48 h antes del procedimiento.</font></p>     <p align="justify"><font face="verdana" size="2"><i>&Eacute;xito angiogr&aacute;fico </i>se consider&oacute; cuando el resultado angiogr&aacute;fico final mostr&oacute; una lesi&oacute;n residual menor del 10% sin imagen de disecci&oacute;n ni trombo residual en el sitio del stent y con flujo distal TIMI 3. Eventos card&iacute;acos adversos mayores (EC AM) se definieron cuando se presentaba cualquiera de los siguientes eventos: isquemia recurrente, infarto agudo del miocardio, cirug&iacute;a de urgencia o muerte por complicaci&oacute;n card&iacute;aca.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><b>Resultados</b></font></p>     <p align="justify"><font face="verdana" size="2">Los resultados se describen dependiendo del tipo de indicaci&oacute;n angiogr&aacute;fica.</font></p>     <p align="justify"><font face="verdana" size="2"><i>Injertos venosos con cambios degenerativos. </i>Todas las lesiones tratadas se localizaron en el cuerpo del injerto venoso. El tiempo promedio de la revascularizaci&oacute;n quir&uacute;rgica hasta la fecha del procedimiento fue de 8 &plusmn; 3 a&ntilde;os. En el grupo total de ocho casos se infundi&oacute; desde el inicio del procedimiento inhibidores IIb&#150;IIIa y en todos ellos se realiz&oacute; pre&#150;dilataci&oacute;n con cat&eacute;ter bal&oacute;n en el sitio de la lesi&oacute;n. De los ocho stents implantados, cinco tuvieron una longitud de 19 mm y tres fueron de 26 mm. La presi&oacute;n de impactaci&oacute;n promedio fue de 14 &plusmn; 3 atm&oacute;sferas. El promedio de severidad de la estenosis pre&#150;procedimiento valorada por angiograf&iacute;a coronaria cuantitativa en todas las lesiones analizadas fue del 84% &plusmn; 13 y post&#150;procedimiento fue del 4% &plusmn; 2. En un caso de lesi&oacute;n sub&#150;oclusiva por trombo grande con cambios degenerativos y conectado a la arteria descendente anterior se utiliz&oacute; el sistema de trombectom&iacute;a y aspiraci&oacute;n con cat&eacute;ter X&#150;Sizer antes del implante de un stent de PTFE de 26 mm <a href="/img/revistas/acm/v75n3/a04f2.jpg" target="_blank">(Fig. 2)</a><i>. </i>&Eacute;xito angiogr&aacute;fico se obtuvo en el 100% de los casos. En ninguno de los casos hubo embolizaci&oacute;n hacia la arteria coronaria nativa receptora del injerto y tampoco en ninguno de los casos se observ&oacute; fen&oacute;meno de "no&#150;reflujo". Elevaci&oacute;n s&eacute;rica de CK dos veces mayor al nivel normal s&oacute;lo estuvo presente en un caso que fue intervenido por infarto al miocardio en evoluci&oacute;n. En este grupo de enfermos con lesiones en injertos venosos ninguno present&oacute; ECMA en la fase hospitalaria inicial; sin embargo durante el seguimiento cl&iacute;nico a 10 meses como promedio, seis de los pacientes se encontraban en clase funcional I de la Clasificaci&oacute;n Canadiense de Angina y en uno de ellos un angiograma de control 13 meses despu&eacute;s no mostr&oacute; reestenosis, los otros dos casos presentaron eventos de isquemia recurrente que fueron causados por oclusi&oacute;n tromb&oacute;tica del stent demostrada angiogr&aacute;ficamente; el primero de ellos tuvo coincidencia con la suspensi&oacute;n de clopidogrel dos semanas despu&eacute;s del procedimiento y el otro aconteci&oacute; cuatro meses despu&eacute;s del procedimiento con manifestaci&oacute;n cl&iacute;nica de insuficiencia card&iacute;aca r&aacute;pidamente progresiva.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><i>Aneurismas coronarios. </i>De los cuatro casos tratados, en tres de ellos la localizaci&oacute;n del aneurisma fue en el tercio medio de la arteria coronaria derecha y en el otro caso en la arteria circunfleja. En tres de los casos se utilizaron stents con longitud de 19 mm y en el otro se utilizaron dos stents empalmados. La presi&oacute;n de impactaci&oacute;n promedio fue de 18 &plusmn; 2 atm&oacute;sferas. En un caso con aneurisma parcialmente trombosado en la arteria circunfleja se infundi&oacute; localmente abciximab a trav&eacute;s de un cat&eacute;ter de infusi&oacute;n intracoronario con dosis de 40 mg en bolo I&#150;V y posteriormente se mantuvo una infusi&oacute;n de 10 mg/hora durante seis horas. El angiograma de control mostr&oacute; desaparici&oacute;n total del trombo y a continuaci&oacute;n se implantaron dos stents empalmados de 19 y 16 mm para cubrir totalmente la longitud del aneurisma <a href="/img/revistas/acm/v75n3/a04f3.jpg" target="_blank">(Fig. 3)</a><i>. </i>Se obtuvo &eacute;xito angio gr&aacute;fico y cl&iacute;nico en los cuatro enfermos sin desarrollo de ECMA durante la fase hospitalaria. La evoluci&oacute;n cl&iacute;nica a largo plazo durante un seguimiento promedio de 10 meses evidenci&oacute; que tres de los pacientes estaban libres de eventos isqu&eacute;micos recurrentes, incluso en uno de ellos con el aneurisma tratado en la arteria circunfleja se obtuvo angiograma de control a los seis meses, que mostr&oacute; permeabilidad sin evidencia de reestenosis de los dos stents empalmados en el sitio del aneurisma. El otro enfermo que inicialmente hab&iacute;a tenido &eacute;xito present&oacute; muerte s&uacute;bita diez semanas despu&eacute;s del implante del stent.</font></p>     <p align="justify"><font face="verdana" size="2"><i>Perforaci&oacute;n de arteria coronaria. El primer caso </i>correspondi&oacute; a un paciente que ingres&oacute; por angor inestable. La coronariograf&iacute;a mostr&oacute; lesi&oacute;n cr&iacute;tica y calcificada con enfermedad difusa en la porci&oacute;n proximal de la arteria circunfleja. De primera instancia se utiliz&oacute; rotablaci&oacute;n, habiendo imposibilidad para cruzar la lesi&oacute;n con una oliva de 1.25 mm. El angiograma de control mostr&oacute; extravasaci&oacute;n de material de contraste hacia el espacio peric&aacute;rdico (perforaci&oacute;n grado III)<sup>5</sup> e inmediatamente se coloc&oacute; stent PTFE montado en bal&oacute;n de 3.0 x 16 mm obteni&eacute;ndose una correcci&oacute;n total de la perforaci&oacute;n vascular <a href="/img/revistas/acm/v75n3/a04f4.jpg" target="_blank">(Fig. 4)</a><i>. </i>El ecocardiograma s&oacute;lo mostr&oacute; derrame peric&aacute;rdico leve sin datos de taponamiento card&iacute;aco. El enfermo egres&oacute; dos d&iacute;as despu&eacute;s sin complicaciones y en el seguimiento cl&iacute;nico a 9 meses se encontraba asintom&aacute;tico cardiovascular. El segundo caso aconteci&oacute; en un paciente con infarto agudo en evoluci&oacute;n de localizaci&oacute;n inferior. El angiograma inicial mostr&oacute; lesi&oacute;n sub&#150;oclusiva en el tercio medio de la arteria coronaria derecha con trombo grande subyacente &gt; 10 mm y con flujo distal TIMI 2. Inicialmente se utiliz&oacute; cat&eacute;ter X&#150;Sizer, realiz&aacute;ndose seis pases a trav&eacute;s de la lesi&oacute;n tromb&oacute;tica. El angiograma inmediato mostr&oacute; extravasaci&oacute;n de material de contraste con infiltraci&oacute;n mioc&aacute;rdica significativa de material de contraste en el lecho perivascular (perforaci&oacute;n grado III). En forma inmediata se implant&oacute; un stent de 26 mm montado en un cat&eacute;ter bal&oacute;n de 4.5 x 30 mm en el sitio de la perforaci&oacute;n vascular. As&iacute; mismo, se coloc&oacute; un stent Jomed 4.0 x16 mm en el sitio de la lesi&oacute;n responsable de la oclusi&oacute;n tromb&oacute;tica en el segmento vertical. El ecocardiograma mostr&oacute; derrame peric&aacute;rdico leve sin evidencia de taponamiento card&iacute;aco. El angiograma final mostr&oacute; ausencia de lesi&oacute;n residual en ambos stents con corree ci&oacute;n total de la perforaci&oacute;n sin trombo residual y flujo TIMI 3. La angiograf&iacute;a de control en el seguimiento a 8 meses no mostr&oacute; reestenosis en el sitio del stent injerto.</font></p>     <p align="justify"><font face="verdana" size="2"><i>Trombo localizado en arteria coronaria nativa "refractario" a tratamiento habitual. </i>En este t&oacute;pico hubo tres pacientes. El primero de ellos ingres&oacute; con infarto inferior en evoluci&oacute;n document&aacute;ndose angiogr&aacute;ficamente estenosis aparentemente significativa con trombo grande adyacente de 13 mm de longitud localizado en el segmento vertical de la coronaria derecha con flujo distal TIMI 2, inmediatamente se administr&oacute; tirofib&aacute;n por v&iacute;a parenteral y se realizaron 8 pases con el cat&eacute;ter X&#150;Sizer en el sitio de la lesi&oacute;n; as&iacute; como dilataciones complementarias con cat&eacute;ter bal&oacute;n. El control angiogr&aacute;fico mostr&oacute; poca mejor&iacute;a en el tama&ntilde;o del trombo por lo que se coloc&oacute; un stent de PTFE de 16 mm montado en bal&oacute;n de 4.0 x 20 mm. El resultado final mostr&oacute; exclusi&oacute;n total del trombo sin evidencia de embolizaci&oacute;n ni de fen&oacute;meno de "no&#150;reflujo" <a href="/img/revistas/acm/v75n3/a04f5.jpg" target="_blank">(Fig. 5)</a><i>. </i>En el seguimiento cl&iacute;nico a 8 meses el paciente se encontraba asintom&aacute;tico cardiovascular. <i>El segundo caso </i>correspondi&oacute; a un paciente de 44 a&ntilde;os con angor post&#150;infarto. El angiograma mostr&oacute; lesi&oacute;n significativa en el tercio medio de la arteria coronaria derecha con imagen de trombo grande adyacente. Se inici&oacute; abciximab al inicio del procedimiento. La lesi&oacute;n tromb&oacute;tica se trat&oacute; inicialmente con cat&eacute;ter bal&oacute;n sin disminuci&oacute;n en el tama&ntilde;o del trombo, decidi&eacute;ndose implantar stent PTFE de 4.0 x 16 mm el resultado mostr&oacute; exclusi&oacute;n del trombo sin lesi&oacute;n residual y flujo distal normal, no hubo complicaciones y en el seguimiento cl&iacute;nico a 8 meses estaba asintom&aacute;tico. El <i>tercer caso </i>trat&oacute; de un enfermo de 67 a&ntilde;os con angor inestable, cuya angiograf&iacute;a coronaria mostr&oacute; lesi&oacute;n exc&eacute;ntrica con calcificaci&oacute;n y trombo grande adyacente. Se inici&oacute; abciximab durante 48 h y el angiograma de control mostr&oacute; persistencia del trombo por lo que se predilat&oacute; con un cat&eacute;ter bal&oacute;n 4.0 x 20 mm de "alta presi&oacute;n" con el que fue posible romper el sitio de placa "dura"; se consider&oacute; que el uso de cat&eacute;ter X&#150;Sizer no era indicado por la presencia de calcificaci&oacute;n en el trayecto vascular previo a la lesi&oacute;n y por lo tanto se coloc&oacute; un stent de PTFE de 4.0 x 16 mm con resultado angiogr&aacute;fico que mostr&oacute; exclusi&oacute;n total del trombo. En el seguimiento a 9 meses el enfermo se encontraba libre de eventos isqu&eacute;micos card&iacute;acos.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Discusi&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">La evoluci&oacute;n tecnol&oacute;gica del stent coronario no solamente comprende a una estructura inerte que proporciona un andamiaje met&aacute;lico que expande la pared vascular aumentando el &aacute;rea circunferencial del lumen arterial modificando la remodelaci&oacute;n vascular<sup>6</sup> y disminuyendo la reestenosis angiogr&aacute;fica,<sup>7,8</sup> sino tambi&eacute;n ha llegado a constituir un medio o vector que puede actuar con diferentes y espec&iacute;ficas funciones como ser&iacute;an la de actuar como un reservorio para la <i>"liberaci&oacute;n local" </i>de f&aacute;rmacos antiproliferativos o antitromb&oacute;ticos,<sup>9</sup><sup>&#150;12</sup> tambi&eacute;n puede actuar como una <i>"barrera f&iacute;sica" </i>por medio del stent cubierto con membrana con el prop&oacute;sito de evitar la embolizaci&oacute;n de "detritus" tisulares o trombos, atrap&aacute;ndolos contra la pared vascular en el tratamiento de lesiones degenerativas o tromb&oacute;ticas. Esta misma barrera tiene la versatilidad de actuar como un "sello" en caso de perforaci&oacute;n vascular coronaria como causa de complicaci&oacute;n de procedimientos de terapia endovascular y as&iacute; mismo debido a las propiedades de ferulizaci&oacute;n y de revestimiento puede restaurar la arquitectura intraluminal en el caso de aneurisma coronario. Es importante mencionar que el primer reporte cl&iacute;nico de la utilidad del stent de membrana con PTFE fue descrito por Gerckens en 1998.<sup>13</sup>La experiencia con la utilizaci&oacute;n del stent de membrana de PTFE en nuestra serie caracterizada por distintas entidades angiogr&aacute;ficas mostr&oacute; un escenario optimista durante la fase hospitalaria, ya que se obtuvo un &eacute;xito cl&iacute;nico del 100%. En el grupo total de pacientes tratados no hubo eventos card&iacute;acos adversos mayores durante la fase hospitalaria, as&iacute; como tampoco elevaci&oacute;n del nivel s&eacute;rico de CPK mayor de dos veces al nivel normal en los procedimientos no relacionados a infarto agudo. Es importante destacar que en el total de los pacientes tratados con stent de PTFE no se presentaron eventos de embolizaci&oacute;n en el lecho vascular distal ni tampoco fen&oacute;meno de "no&#150;reflujo". Sin embargo, en el seguimiento cl&iacute;nico a 10 meses como promedio los resultados iniciales tan favorables no se mantuvieron, ya que en tres de ellos (19%) hubo eventos card&iacute;acos asociados a oclusi&oacute;n o cierre abrupto del stent (uno de ellos con infarto del miocardio por oclusi&oacute;n aguda del stent que coincidi&oacute; con la suspensi&oacute;n temprana de clopidogrel, otro enfermo tuvo insuficiencia card&iacute;aca que se asoci&oacute; a oclusi&oacute;n tromb&oacute;tica tard&iacute;a del stent y el otro present&oacute; muerte s&uacute;bita dos meses despu&eacute;s del procedimiento) <a href="#t2">(Tabla II)</a><i>.</i></font></p>     <p align="center"><font face="verdana" size="2"><i><a name="t2"></a></i></font></p>     <p align="center"><font face="verdana" size="2"><i><img src="/img/revistas/acm/v75n3/a04t2.jpg"></i></font></p>     <p align="justify"><font face="verdana" size="2">En el grupo de pacientes con <i>injertos venosos </i>en los que exist&iacute;a un ingrediente tromb&oacute;tico es relevante destacar que en forma conjunta se utilizaron inhibidores IIb&#150;III ay en uno de ellos adem&aacute;s se utiliz&oacute; sistema de trombectom&iacute;a con cat&eacute;ter X&#150;sizer. Los resultados obtenidos en nuestra serie de injertos venosos tratados con stent de PTFE durante la fase hospitalaria fueron muy alentadores y similares a aqu&eacute;llos reportados por otros autores en los que los resultados durante la fase hospitalaria mostraron una tasa reducida de ECMA.<sup>1,13&#150;17</sup> Uno de los registros m&aacute;s grandes con la experiencia del stent de PTFE en injertos venosos fue el de Baldus y cols.<sup>18</sup> que analiz&oacute; prospectivamente a 125 stents implantados en 109 enfermos con lesiones localizadas en el cuerpo de injertos venosos y con duraci&oacute;n promedio de 11 a&ntilde;os despu&eacute;s de la cirug&iacute;a de revascularizaci&oacute;n; s&oacute;lo el 19% de todos los injertos tuvieron cambios degenerativos con trombo. Los resultados de este estudio mostraron &eacute;xito cl&iacute;nico del 98% con obtenci&oacute;n de flujo TIMI 3 en el 95% al final del procedimiento; embolizaci&oacute;n distal aconteci&oacute; en el 4% y elevaci&oacute;n s&eacute;rica de CK mayor del doble del valor inicial en s&oacute;lo el 5% de los casos. Sin embargo en el seguimiento a 6 meses los resultados no fueron tan alentadores ya que hubo mortalidad por etiolog&iacute;a card&iacute;aca del 7%, otros tres pacientes tuvieron infarto Q y en nueve hubo necesidad de volver a realizar nuevo procedimiento intervencionista en el vaso inicialmente tratado. Es importante destacar que la mayor&iacute;a de los enfermos en este estudio tuvieron un per&iacute;odo insuficiente de tratamiento con clopidogrel o ticlopidina post&#150;intervenci&oacute;n de s&oacute;lo diez semanas, lo que probablemente influy&oacute; en el seguimiento a largo plazo en una mayor incidencia de eventos isqu&eacute;micos recurrentes debido a un incremento en la frecuencia de eventos de oclusi&oacute;n tromb&oacute;tica tard&iacute;a. Recientemente el stent de PTFE se ha puesto a prueba en tres estudios multic&eacute;ntricos y aleatorizados que han evaluado al stent de PTFE en el tratamiento de injertos venosos compar&aacute;ndolos con stents convencionales el primero de ellos es el RECOVERS,<sup>19</sup> el segundo es el STING<sup>20</sup> y el &uacute;ltimo es el BARRICADE.<sup>21</sup> El estudio RECOVERS aleatoriz&oacute; a 301 pts (156 con stent de PTFE y 145 con stent convencional de Jomed), con el objetivo primario de evaluar la reestenosis angiogr&aacute;fica a 6 meses y secundariamente la evaluaci&oacute;n de eventos card&iacute;acos mayores adversos (ECMA) a 30 d&iacute;as y 6 meses. Lesiones con trombo grande que ocupaban &gt; 50% del di&aacute;metro vascular fueron excluidas y s&oacute;lo se incluyeron un 41% de lesiones con cambios degenerativos en el grupo con stent PTFE. El &eacute;xito angiogr&aacute;fico fue similar entre ambos grupos (PTFE: 97% <i>vs </i>stent Jomed: 98%); sin embargo, los ECMA en fase temprana fueron mayores en el grupo PTFE (10.3% <i>vs </i>3.4%, p = 0.047). La reestenosis angiogr&aacute;fica a 6 meses no mostr&oacute; diferencias entre ambos grupos (24.2% <i>vs </i>24.8%). Los resultados de este estudio con lesiones predominantemente de moderada complejidad no mostraron ventaja del stent de PTFE sobre el stent convencional acarreando por otro lado una tasa mayor de complicaciones card&iacute;acas intrahospitalarias debidas principalmente a una frecuencia mayor de infartos no&#150;Q. El estudio STING aleatoriz&oacute; a 211 pacientes (106 con stent convencional Flex stent <i>vs </i>105 a stent PTFE) con el objetivo primario de evaluar la reestenosis angiogr&aacute;fica a 6 meses. Este estudio no describe en forma categ&oacute;rica la inclusi&oacute;n de lesiones degenerativas con trombo y s&oacute;lo hace menci&oacute;n que el 28% de las lesiones intervenidas en cada grupo correspond&iacute;an a lesiones complejas. Los resultados no mostraron diferencias en las tasas de &eacute;xito angiogr&aacute;fico y en ECMA durante la fase hospitalaria. Se obtuvo una tasa de reestenosis comparable entre ambos grupos (Flex 20% <i>vs </i>PTFE 29%; p = 0.15), sin embargo se observ&oacute; una tendencia a una frecuencia mayor de eventos de oclusi&oacute;n tard&iacute;a en el grupo de PTFE (16% <i>vs </i>7%; p = 0.069). En el seguimiento a 14 meses no hubo diferencias en la tasa acumulativa de eventos card&iacute;acos en lo que se refiere a mortalidad, infarto o revascularizaci&oacute;n del vaso "blanco" los resultados de este estudio no mostraron superioridad del stent PTFE <i>vs </i>stent convencional en lo que se refiere a la frecuencia de reestenosis o de ECAM acumulados durante el seguimiento a largo plazo. Por &uacute;ltimo el estudio BARRICADE, que tuvo la intenci&oacute;n inicial de reclutar a 500 pts, aleatoriz&oacute; a la mitad de ellos a implante de stent convencional <i>vs </i>stent injerto Jo stent con el objetivo primario de evaluar reestenosis angiogr&aacute;fica a 8 meses. Los criterios de inclusi&oacute;n comprendieron lesiones en injertos venosos con longitud 25 mm y con di&aacute;metro vascular del hemoducto entre 3.0 a 5.0 mm dejando a criterio del operador la utilizaci&oacute;n de dispositivos de protecci&oacute;n distal o bien de trombectom&iacute;a con aspiraci&oacute;n, la administraci&oacute;n de clopidogrel se indic&oacute; por lo menos durante 8 meses. Sin embargo despu&eacute;s del reclutamiento de 241 pts y en el an&aacute;lisis de los primeros 125 pts con seguimiento a 8 meses se decidi&oacute; suspender el estudio debido principalmente al hallazgo de una tasa inusualmente elevada de oclusi&oacute;n total en el grupo con injerto stent comparativamente al stent convencional (26.7 <i>vs </i>9.6%, p = 0.28), as&iacute; mismo el stent injerto de PTFE no demostr&oacute; reducci&oacute;n en la tasa de reestenosis angiogr&aacute;fica ni en la sobrevida libre de eventos card&iacute;acos comparativamente al stent convencional. En s&iacute;ntesis los resultados poco favorables de los estudios RECOVERS, STING y BARRICADE orillan en el momento actual al stent de PTFE a una aplicaci&oacute;n muy limitada en el escenario de los <i>injertos venosos; </i>adem&aacute;s su uso se asocia a una tasa muy elevada de oclusi&oacute;n tard&iacute;a y a una mayor frecuencia de ECMA en fase temprana.</font></p>     <p align="justify"><font face="verdana" size="2">En lo que se refiere a los <i>aneurismas coronarios, </i>su incidencia var&iacute;a entre 0.1 % al 4.9%<sup>4</sup> y se dividen en dos tipos (aneurismas verdaderos y seudoaneurismas) que pueden diferenciarse por ultrasonido intracoronario.<sup>22</sup>Los aneurismas coronarios pueden desencadenar isquemia mioc&aacute;rdica por trombosis <i>in situ </i>y embolizaci&oacute;n. El tratamiento ha sido controversial y diversos autores han recomendado tratamiento m&eacute;dico con anticoagulantes y antiagregantes plaquetarios, e incluso otros han optado por tratamiento quir&uacute;rgico de revascularizaci&oacute;n con o sin resecci&oacute;n o bien ligadura del aneurisma.<sup>23,24</sup> Desde el punto de vista del tratamiento intervencionista el primer reporte exitoso de un stent con membrana para el tratamiento de un aneurisma coronario fue descrito por Wong y cols, utilizando un stent convencional cubierto de injerto aut&oacute;logo de vena.<sup>25</sup> Posteriormente con el advenimiento del stent PTFE ha habido un incremento progresivo en el n&uacute;mero de casos reportados de aneurismas coronarios tratados exitosamente.<sup>26&#150;28</sup> Las limitaciones principales para la utilizaci&oacute;n del stent con membrana de PTFE han sido en general la oclusi&oacute;n de un ramo secundario y la dificultad para avanzar el cat&eacute;ter que distribuye el stent en segmentos vasculares tortuosos debido a la rigidez y poca flexibilidad del stent especialmente en el stent montado manualmente.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Ante la evidencia cada vez m&aacute;s creciente de la utilizaci&oacute;n de stents con membrana para la correcci&oacute;n de aneurismas coronarios con la restauraci&oacute;n de la arquitectura intraluminal y del flujo laminar es muy probable que este tipo de stent en el momento actual sea la alternativa terap&eacute;utica m&aacute;s adecuada para este tipo de afecci&oacute;n coronaria.</font></p>     <p align="justify"><font face="verdana" size="2"><i>La perforaci&oacute;n coronaria </i>puede presentarse entre el 0.1% al 3% de las lesiones tratadas con diversas t&eacute;cnicas de intervencionismo.<sup>5,29</sup> Existe mayor riesgo de perforaci&oacute;n cuando se utilizan dispositivos de aterectom&iacute;a rotacional o direccional y recientemente se han descrito los primeros casos con la utilizaci&oacute;n del sistema X&#150;Sizer de trombectom&iacute;a.<sup>30</sup> El &uacute;nico abordaje terap&eacute;utico de la perforaci&oacute;n coronaria durante los a&ntilde;os 80 y gran parte de los 90 fue con cat&eacute;ter bal&oacute;n convencional o bien con cat&eacute;ter de autoperfusi&oacute;n que permit&iacute;a un tiempo de insuflaci&oacute;n prolongado y como medidas generales conjuntas la administraci&oacute;n de protamina y una pronta valoraci&oacute;n ecocardiogr&aacute;fica para evaluaci&oacute;n de taponamiento card&iacute;aco y en caso necesario pericardiocentesis. En ocasiones y de manera adicional se colocaban stents convencionales con pobres resultados. Con las anteriores medidas terap&eacute;uticas era factible corregir un 40 a 50% de las perforaciones en el lecho vascular coronario y en caso contrario el paciente ten&iacute;a que someterse a cirug&iacute;a de urgencia con morbi&#150;mortalidad elevada.<sup>31</sup> Con el advenimiento del stent cubierto inicialmente de vena aut&oacute;loga y despu&eacute;s con membrana de PTFE ha permitido que este dispositivo sea en el momento actual la alternativa m&aacute;s eficaz y confiable en reducir significativamente las complicaciones emanadas de una perforaci&oacute;n coronaria, ya que literalmente "sella" la pared vascular y "restaura" desde el punto de vista angiogr&aacute;fico la arquitectura intraluminal en el sitio de la perforaci&oacute;n.<sup>32&#150;34</sup> Las limitaciones observadas de su uso en caso de perforaci&oacute;n son las inherentes a la rigidez intr&iacute;nseca del dispositivo lo que dificulta o imposibilita el abordaje hacia perforaciones distales cuando existe un acceso vascular coronario tortuoso. As&iacute; mismo un punto de precauci&oacute;n es el hecho de que si la perforaci&oacute;n acontece en un segmento vascular donde se origina un ramo secundario grande, &eacute;ste quedar&aacute; excluido con las complicaciones isqu&eacute;micas inherentes. En nuestra serie los dos casos de perforaci&oacute;n fueron debidos por rotablaci&oacute;n en un caso y por cat&eacute;ter X&#150;sizer, en ambos el sitio de perforaci&oacute;n fue sellado exitosamente con el stent de PTFE sin ECMA en la fase hospitalaria, ni durante el seguimiento a largo plazo.</font></p>     <p align="justify"><font face="verdana" size="2">La utilizaci&oacute;n del stent de PTFE para el tratamiento de <i>trombo coronario "grande" </i>que no responde a tratamiento en arterias coronarias nativas es muy controversial y existe m&iacute;nima evidencia reportada en la literatura, sin embargo podr&iacute;a ser una medida terap&eacute;utica "justificable" en casos muy seleccionados en los que otros recursos terap&eacute;uticos, mec&aacute;nicos y farmacol&oacute;gicos han fallado para mejorar o eliminar un trombo coronario grande.</font></p>     <p align="justify"><font face="verdana" size="2">En resumen a pesar de m&uacute;ltiples reportes en la literatura con tasas elevadas de &eacute;xito con el stent de PTFE en distintas condiciones cl&iacute;nicas y angiogr&aacute;ficas durante la fase hospitalaria y durante la fase temprana de seguimiento, los resultados a largo plazo en lo que se refiere a una sobrevida libre de eventos card&iacute;acos no han sido tan gratificantes debido a la presencia de eventos de oclusi&oacute;n tromb&oacute;tica tard&iacute;a que acontec&iacute;an dentro de semanas a pocos meses despu&eacute;s del implante del stent y que se asociaban a per&iacute;odos relativamente cortos de tratamiento con clopidogrel o ticlopidina. Este fen&oacute;meno de oclusi&oacute;n tromb&oacute;tica se document&oacute; en el seguimiento en dos de nuestros pacientes y es probable que haya acontecido en el paciente que tuvo muerte s&uacute;bita dos meses despu&eacute;s del procedimiento. Es importante mencionar que estos tres casos pertenecieron a los primeros realizados en nuestra serie en los que el uso del clopidogrel se extendi&oacute; exclusivamente a s&oacute;lo ocho semanas post&#150;procedimiento. El fen&oacute;meno de oclusi&oacute;n tromb&oacute;tica tard&iacute;a en el stent de PTFE es debido a un fen&oacute;meno de "re&#150;endotelizaci&oacute;n tard&iacute;a" del stent por lo que se ha establecido como norma terap&eacute;utica la administraci&oacute;n de clopidogrel por un per&iacute;odo m&iacute;nimo de 6 meses posterior al implante del stent de PTFE, lo cual ha reducido parcialmente la aparici&oacute;n de eventos de oclusi&oacute;n tromb&oacute;tica temprana. Otra limitaci&oacute;n de este stent injerto con membrana de PTFE es la tasa de reestenosis tard&iacute;a que a juzgar por los estudios aleatorizados es muy comparable a la observada en los stents convencionales "no liberadores de droga".</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusiones</b></font></p>     <p align="justify"><font face="verdana" size="2">Las indicaciones para la implantaci&oacute;n del stent cubierto con membrana de PTFE no han sido determinadas en forma absoluta; sin embargo es muy convincente que en la perforaci&oacute;n coronaria secundaria a una complicaci&oacute;n de intervencionismo coronario habr&iacute;a poca duda en implantar un stent cubierto de membrana en arterias epic&aacute;rdicas &gt; 2.5 mm para evitar las complicaciones de morbi&#150;mortalidad inherentes a taponamiento card&iacute;aco. En casos seleccionados de aneurisma coronario la colocaci&oacute;n del stent de PTFE es una alternativa terap&eacute;utica atractiva ya que restaura la arquitectura intraluminal restableciendo el flujo laminar y evitando la complicaci&oacute;n de trombosis que se presenta en el segmento de dilataci&oacute;n vascular. En los casos de injertos venosos que presentan abundante material tromb&oacute;tico y/o "detritus" tisulares, una ventaja te&oacute;rica ser&iacute;a prevenir la embolizaci&oacute;n distal de trombo y de material de placa ateroscler&oacute;tica; no obstante a pesar de esta atractiva hip&oacute;tesis en los estudios aleatorizados<sup>19&#150;21</sup> publicados recientemente y analizados en la secci&oacute;n de discusi&oacute;n no se demostro mayor beneficio con el stent de PTFE comparativamente al stent convencional, sino m&aacute;s bien un efecto delet&eacute;reo con una mayor frecuencia en eventos isqu&eacute;micos especialmente infarto no Q durante la fase hospitalaria y una tasa elevada de oclusi&oacute;n tard&iacute;a. En este &uacute;ltimo t&oacute;pico, en la actualidad la tendencia terap&eacute;utica en el tratamiento de lesiones en injertos venosos es la de utilizar implante de stent liberador de droga combinado con filtros de protecci&oacute;n distal, ya que algunos estudios multic&eacute;ntricos y aleatorizados han demostrado la eficacia de este tipo de dispositivos en reducir la tasa de eventos isqu&eacute;micos especialmente en lo que concierne a la frecuencia de infarto sin elevaci&oacute;n del segmento S&#150;T, as&iacute; como tambi&eacute;n una reducci&oacute;n en la frecuencia del fen&oacute;meno de "no&#150;reflujo" y de eventos de embolizaci&oacute;n distal.<sup>35,36</sup></font></p>     <p align="justify"><font face="verdana" size="2">El futuro de los stents cubiertos con membrana de PTFE probablemente consistir&aacute; en lograr una mejor&iacute;a de sus caracter&iacute;sticas tecnol&oacute;gicas reduciendo el perfil del dispositivo y aumentando su flexibilidad para abordar a segmentos vasculares tortuosos y distales. Por otro lado resultar&iacute;a muy atractivo el hecho de que en la membrana de PTFE puedan incorporarse drogas anti&#150;proliferativas y/o antitromb&oacute;ticas con el objeto de reducir algunas de las principales limitaciones de este tipo de stents que son la reestenosis y la oclusi&oacute;n tromb&oacute;tica tard&iacute;a.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Referencias</b></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">1. Elsner M, Auch&#150;Schwelk W, Britten M, Walter DH, Schachinger V, Zeiher AM: <i>Coronary stent grafts covered by a polytetrafluoroethylene membrane. </i>Am J Cardiol 1999; 84: 335&#150;338.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035504&pid=S1405-9940200500030000400001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">2. Lefkovits J, Holmes RD, Califf RM, Safian RD, Pieper K, Keeler G, Topol EJ: <i>Predictors and sequelae of distal embolization during saphenous vein graft intervention from the CAVEAT&#150;II trial. </i>Circulation 1995; 92: 734&#150;740.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035505&pid=S1405-9940200500030000400002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">3. Wilensky R, Bourdillon P, Vernon AV, Seller JA: <i>Intracoronary artery thrombus formation in unstable angina: a clinical, biochemical and angiographic correlation. </i>J Am Coll Cardiol 1993; 21: 692&#150;699.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035506&pid=S1405-9940200500030000400003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">4. Swaye PS, Fisher LD, Litwin P: <i>Aneurysmal coronary artery disease. </i>Circulation 1983; 67: 134&#150;138.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035507&pid=S1405-9940200500030000400004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">5. Ellis SG, Ajluni S, Arnold AZ, Popma JF, Bittl JA, Eigler NL, Cowley MJ, Raymond RE, Safian RD, Whitlow PL: <i>Increased coronary perforation in the new device era: incidence, classification, management and outcome. </i>Circulation 1994; 90: 2725&#150;2730.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035508&pid=S1405-9940200500030000400005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">6. Sigwart U, Puel J, Mirkovith V, Joffre F, Kappenberger L: <i>Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. </i>N Engl J Med 1987; 316: 701&#150;706.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035509&pid=S1405-9940200500030000400006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">7. Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndricks G, Emmanuelson H, Marco J, Legrand V, Materne P, Bilardi J, Sigwart U, Colombo A, Jacques GJ, van den Heuvel P, Delcan J, Morel Maria&#150;angele, for the Benestent Study Group. <i>A comparison of Balloon&#150;Expandable e&#150;Stent implantation with Balloon Angioplasty in Patients with Coronary Artery Disease. </i>N Engl J Med 1994; 331: 489&#150;495.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035510&pid=S1405-9940200500030000400007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">8. <i>Fischman DL, Leon MB, Bairn DS, Schatz RA, Savage MP, Penn I, Detre K, Veltri L, Ricci D, Nobuyoshi M, Cleman M, Heuser R, Almond D, Teirstein PS, Fish RD, Colombo A, Brinker J, Moses J, Shaknovich A, Hirshfeld J, Bailey S, Ellis S, Rake R, Goldberg S: A Randomized Comparison of Coronary&#150;stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease. </i>N Engl J Med 1994; 331: 496&#150;501.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035511&pid=S1405-9940200500030000400008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">9. Herdeg C, Oberhoff M, Baumbach A, Blattner A, Axel DI, Schr&ouml;der S, Heinle H, Karsch KR: <i>Local paclitaxel delivery for the prevention of restenosis: biological effects and efficacy </i>in vivo. J Am Coll Cardiol 2000; 35: 1969&#150;1976.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035512&pid=S1405-9940200500030000400009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">10. Morice M&#150;C, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barrag&aacute;n P, Guagliumi G, Molnar F, Falotico R: <i>A randomized comparison of a sirolimus&#150;eluting stent with a standard stent for coronary revascularization. </i>N Engl J Med 346:1773&#150;1780.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035513&pid=S1405-9940200500030000400010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">11. Moses JF, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, OcShaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE: <i>Sirolimus&#150;eluting stents versus standard stents in patients with stenosis in a native coronary artery. </i>N Engl J Med 2003; 349: 1315&#150;1323.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035514&pid=S1405-9940200500030000400011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">12. Serruys P, Emanuelsson H, Vander Giessen W, Van der Giessen W, Lunn AC, Kiemeney F, Macaya C, Rutsch W, Hendrickx G, Suryapranata H, Legrand V, Goy JJ, Materne P, Bonnier H, Morice M&#150;C, Fajadet J, Belardi J, Colombo A, Garc&iacute;a E, Ruygrok P, De Jaegere P, Morel MA: <i>Heparin&#150;coated Palmaz&#150;Schatz stents in human coronary arteries: early outcome of the Benestent&#150;II pilot study. </i>Circulation 1996; 93: 412&#150;422.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035515&pid=S1405-9940200500030000400012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">13. Gerckens U, M&uuml;ller R, Cattelaens M, Grube E: <i>The New Coronary Stent Graft Jostent: First </i><i>clinical experience. </i>J Am Coll Cardiol 1998; 31(2);Suppl A: 414A.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035516&pid=S1405-9940200500030000400013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">14. Elsner M, Auch&#150;Schwelk W, Britten M: <i>Coronary stent grafts covered by a polytetrafluoroethylene membrane. </i>Am J Cardiol 1999; 84: 335&#150;338.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035517&pid=S1405-9940200500030000400014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">15. St&ouml;rger H, Haase J: <i>Polytetrafluoroethylene Covered stents: Indications, Advantages and limitations. J Interven Caidiol </i>1999; 12: 451&#150;456.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035518&pid=S1405-9940200500030000400015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">16. Baldus S, K&ouml;ster R, Reimers J, Hamm CW: <i>Membrane&#150;covered stents for the treatment of aorto&#150;coronary vein graft disease. </i>Cathet Cardiovasc Intervent 2000; 50: 83&#150;88.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035519&pid=S1405-9940200500030000400016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">17. Briguori C, De Gregorio J, Nishida T, Adamian M, Albiero R, Tucci G, Di Mario C, Colombo A: <i>Polytetrafluoroethylene&#150;covered stent for the treatment of narrowings in aortic&#150;coronary saphenous vein grafts. </i>Am J Cardiol 2000; 86: 343&#150;346.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035520&pid=S1405-9940200500030000400017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">18. Baldus S, K&ouml;ster R, Elsner M, Walter DH, Arnold R, Auch&#150;Schwelk W, Berger J, Rau M, Meinertz T, Zehier AM, Hamm CW: <i>Treatment of aortocoronary vein graft lesions &#150;with membrane&#150;covered stents. </i>Circulation 2000; 102: 2024&#150;2027.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035521&pid=S1405-9940200500030000400018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">19. Stankovic G, Colombo A, Presb&iacute;tero P, Van den Branden F, Inglese L, Cernigliaro C, Nicolli L, Bartorelli AL, Rubartelli P, Reifart N, Heyndrickx GR, Saunamaki K, Morice MC, Sgura FA, Di Mario C: <i>Randomized evaluation of polytetrafluoroethylene covered stent in saphenous vein grafts (RECOVERS) trial. </i>Circulation 2003; 108: 37&#150;42.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035522&pid=S1405-9940200500030000400019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">20. Sch&auml;chinger V, Hamm CW, M&uuml;nzel T, Haude M, Baldus S, Grube E, Bonzel T, Konorza T, K&ouml;ster R, Arnold R, Haase J, Probst P, Vom Dahe J, Neumann FJ, Mudra H, Hennen B, Thiele L, Zeiher AM: <i>A randomized trial of polytetrafluoroethylene membrane&#150;covered stents compared with conventional stents in aortocoronary vein grafts. </i>J Am Coll Cardiol 2003; 42: 1360&#150;1369.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035523&pid=S1405-9940200500030000400020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">21. Stone GW, Goldberg S, Mehran R, O'Shaughnessy Ch, Midel M, Siegel R, George B, Satler L, Raizner A, Negoita M, Fahy M, Arjomand&#150;Fard H, Lansky AJ: Columbia University Medical Center, New York, NY. Cardiovascular Research Foundation, New York, NY: <i>A Prospective, Randomized U.S. Trial of the PTFE Covered JOSTENT for the Treatment of Diseased Saphenous Vein Grafts: The BARRICADE Trial. </i>J Am Coll Cardiol 2005; (Suppl) Feb 2005: 27A.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035524&pid=S1405-9940200500030000400021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">22. Gazzand TJ, Mintz GS, Popma JJ: <i>Intravascular ultrasound diagnosis of a coronary artery pseudoaneurysm following percutaneous transluminal coronary angioplasty. </i>Am Heart J 1993; 125: 880&#150;882.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035525&pid=S1405-9940200500030000400022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">23. Burns CA, Cowley MJ, Weschler AS: <i>Coronary aneurisms: a case report and review. </i>Cathet Cardiovasc Diagn 1992; 27: 106&#150;112.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035526&pid=S1405-9940200500030000400023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">24. Alford WC, Stoney WS, Burrus GR: <i>Recognition and operative management of patients with arteriosclerotic coronary artery aneurysms. </i>Ann Thorac Surg 1976; 22: 317&#150;321.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035527&pid=S1405-9940200500030000400024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">25. Wong SC, Kent KM, Mintz GS: <i>Percutaneous transcatheter repair of a coronary aneurysm using a composite autologous cephalic vein&#150;coated Pal</i><i>maz&#150;Schatz biliary stent. </i>Am J Cardiol 1995; 76: 990&#150;991.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035528&pid=S1405-9940200500030000400025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">26. Antonellis IP, Patsilinakos SP, Pamboukas CA, Kranidis AJ, Prappa E, Filippatos G, Margaris NG, Siaterli M, Tavernarakis AG, Rokas SG: <i>Sealing of coronary artery aneurysm by using a new stent graft. Cathet Cardiovasc Intervent </i>1999; 48: 96&#150;99.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035529&pid=S1405-9940200500030000400026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">27. Briguori C, Sarais C, Sivieri G, Takagi T, Di Mario C, Colombo A: <i>Polytetrafluoroethylene&#150;covered stent and coronary artery aneurysms. </i>Cathet Cardiovasc Intervent 2002; 55: 326&#150;330.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035530&pid=S1405-9940200500030000400027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">28. L&oacute;pez MM, Alfonso F, Fern&aacute;ndez OA, Escaned J, Flores A, Garc&iacute;a P, Arias J, Hern&aacute;ndez R, Macaya C: <i>Treatment of a giant coronary aneurysm with a novel technique: Scaffolding (tunnel) stenting to support PTFE&#150;covered stents: Insights from intravascular ultrasound catheter techniques for the treatment of aneurysms and Pseudoaneurysms. </i>J Invasive Cardiol 2002; 14(5): 273&#150;276.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035531&pid=S1405-9940200500030000400028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">29. Ajluni SC, Glazier S, Blankenship L: <i>Perforation after percutaneous coronary interventions: clinical, angiographic, and therapeutic observations. </i>Cathet Cardiovasc Diagn 1994; 32: 206&#150;212.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035532&pid=S1405-9940200500030000400029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">30. Sanmart&iacute;n M, Goicolea J, Ru&iacute;z&#150;Salmeron R, Mantilla R, Sterling J, Meneses D, Calvo F: <i>Coronary perforation as a potential complication derived from coronary thrombectomy with the X&#150;Sizer device. </i>Cathet Cardiovasc Intervent 2002; 56: 378&#150;382.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035533&pid=S1405-9940200500030000400030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">31. Hall P, Nakamura S, Maiello L: <i>Factors associated with procedural complications during high pressure optimized Palmaz&#150;Schatz intracoronary stent implantation. </i>Circulation 1994; 90(Suppl): 1&#150;612.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035534&pid=S1405-9940200500030000400031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">32. Nageh T, Thomas MR: <i>Coronary Artery Rupture treated with a polytetrafluoroethylene&#150;coated stent. </i>N Engl J Med 2000; 342, 25: 1922&#150;1923.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035535&pid=S1405-9940200500030000400032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">33. Albiero R, Nishida T, Corvaja N, Vaghetti M, Di Mario C, Colombo A: <i>Left internal mammary artery graft perforation repair using polytetra&#150;fluoroethylene covered stents. </i>Cathet Cardiovasc Intervent 2000; 51: 78&#150;82.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035536&pid=S1405-9940200500030000400033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">34. Briguori C, Nishida T, Anzuini A, Di Mario C, Grube E, Colombo A: <i>Emergency polytetrafluo&#150;roethylene covered stent implantation to treat coronary ruptures. </i>Circulation 2000; 102: 3028&#150;3031.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035537&pid=S1405-9940200500030000400034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">35. Baim D, Wahr D, George B, Leon M, Greenberg J, Cutlip D, Kaya U, Popma J, Ho KKL, Kuntz R: <i>Randomized Trial of a Distal Embolic Protection Intervention of Saphenous Vein Aorto&#150;Coronary Bypass Grafts. </i>Circulation 2002; 105: 1285&#150;90.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035538&pid=S1405-9940200500030000400035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">36. Stone GW, Rogers C, Hermiller J, Feldman R, Hell P, Haber R, Masud A,Ramee S, Cox D: <i>Randomized comparison of distal protection with a filter based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto&#150;coronary bypass grafts. </i>Circulation 2003; 108: 548&#150;553.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1035539&pid=S1405-9940200500030000400036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elsner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Auch-Schwelk]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Britten]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Walter]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
<name>
<surname><![CDATA[Schachinger]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Zeiher]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronary stent grafts covered by a polytetrafluoroethylene membrane]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1999</year>
<numero>84</numero>
<issue>84</issue>
<page-range>335-338</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lefkovits]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Califf]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Safian]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Pieper]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Keeler]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Topol]]></surname>
<given-names><![CDATA[EJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Predictors and sequelae of distal embolization during saphenous vein graft intervention from the CAVEAT-II trial]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1995</year>
<numero>92</numero>
<issue>92</issue>
<page-range>734-740</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wilensky]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bourdillon]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Vernon]]></surname>
<given-names><![CDATA[AV]]></given-names>
</name>
<name>
<surname><![CDATA[Seller]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intracoronary artery thrombus formation in unstable angina: a clinical, biochemical and angiographic correlation]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1993</year>
<numero>21</numero>
<issue>21</issue>
<page-range>692-699</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Swaye]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[LD]]></given-names>
</name>
<name>
<surname><![CDATA[Litwin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aneurysmal coronary artery disease]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1983</year>
<numero>67</numero>
<issue>67</issue>
<page-range>134-138</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ellis]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Ajluni]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Arnold]]></surname>
<given-names><![CDATA[AZ]]></given-names>
</name>
<name>
<surname><![CDATA[Popma]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Bittl]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Eigler]]></surname>
<given-names><![CDATA[NL]]></given-names>
</name>
<name>
<surname><![CDATA[Cowley]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Raymond]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Safian]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Whitlow]]></surname>
<given-names><![CDATA[PL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Increased coronary perforation in the new device era: incidence, classification, management and outcome]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1994</year>
<numero>90</numero>
<issue>90</issue>
<page-range>2725-2730</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sigwart]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Puel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mirkovith]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Joffre]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kappenberger]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1987</year>
<numero>316</numero>
<issue>316</issue>
<page-range>701-706</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Serruys]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[de Jaegere]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kiemeneij]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Macaya]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rutsch]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Heyndricks]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Emmanuelson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Marco]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Legrand]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Materne]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bilardi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sigwart]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Jacques]]></surname>
<given-names><![CDATA[GJ]]></given-names>
</name>
<name>
<surname><![CDATA[van den Heuvel]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Delcan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Morel]]></surname>
<given-names><![CDATA[Maria-angele]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of Balloon-Expandable e-Stent implantation with Balloon Angioplasty in Patients with Coronary Artery Disease]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1994</year>
<numero>331</numero>
<issue>331</issue>
<page-range>489-495</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fischman]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Leon]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Bairn]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Schatz]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Savage]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
<name>
<surname><![CDATA[Penn]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Detre]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Veltri]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Ricci]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Nobuyoshi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cleman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Heuser]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Almond]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Teirstein]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
<name>
<surname><![CDATA[Fish]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Brinker]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Moses]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shaknovich]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hirshfeld]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bailey]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ellis]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Rake]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Randomized Comparison of Coronary-stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1994</year>
<numero>331</numero>
<issue>331</issue>
<page-range>496-501</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Herdeg]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Oberhoff]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Baumbach]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Blattner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Axel]]></surname>
<given-names><![CDATA[DI]]></given-names>
</name>
<name>
<surname><![CDATA[Schröder]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Heinle]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Karsch]]></surname>
<given-names><![CDATA[KR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Local paclitaxel delivery for the prevention of restenosis: biological effects and efficacy in vivo]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2000</year>
<numero>35</numero>
<issue>35</issue>
<page-range>1969-1976</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morice]]></surname>
<given-names><![CDATA[M-C]]></given-names>
</name>
<name>
<surname><![CDATA[Serruys]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
<name>
<surname><![CDATA[Sousa]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Fajadet]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ban Hayashi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Perin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Schuler]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Barragán]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Guagliumi]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Molnar]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Falotico]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year></year>
<numero>346</numero>
<issue>346</issue>
<page-range>1773-1780</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moses]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Leon]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Popma]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Fitzgerald]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
<name>
<surname><![CDATA[OcShaughnessy]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Caputo]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
<name>
<surname><![CDATA[Kereiakes]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[DO]]></given-names>
</name>
<name>
<surname><![CDATA[Teirstein]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
<name>
<surname><![CDATA[Jaeger]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Kuntz]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2003</year>
<numero>349</numero>
<issue>349</issue>
<page-range>1315-1323</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Serruys]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Emanuelsson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Vander Giessen]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Van der Giessen]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Lunn]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Kiemeney]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Macaya]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rutsch]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Hendrickx]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Suryapranata]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Legrand]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Goy]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Materne]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bonnier]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Morice]]></surname>
<given-names><![CDATA[M-C]]></given-names>
</name>
<name>
<surname><![CDATA[Fajadet]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Belardi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ruygrok]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[De Jaegere]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Morel]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Heparin-coated Palmaz-Schatz stents in human coronary arteries: early outcome of the Benestent-II pilot study]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1996</year>
<numero>93</numero>
<issue>93</issue>
<page-range>412-422</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gerckens]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Müller]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Cattelaens]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grube]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The New Coronary Stent Graft Jostent: First clinical experience]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1998</year>
<volume>31</volume>
<numero>2^sA</numero>
<issue>2^sA</issue>
<supplement>A</supplement>
<page-range>414</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elsner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Auch-Schwelk]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Britten]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronary stent grafts covered by a polytetrafluoroethylene membrane]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1999</year>
<numero>84</numero>
<issue>84</issue>
<page-range>335-338</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Störger]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Haase]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Polytetrafluoroethylene Covered stents: Indications, Advantages and limitations]]></article-title>
<source><![CDATA[J Interven Caidiol]]></source>
<year>1999</year>
<numero>12</numero>
<issue>12</issue>
<page-range>451-456</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baldus]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Köster]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Reimers]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hamm]]></surname>
<given-names><![CDATA[CW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Membrane-covered stents for the treatment of aorto-coronary vein graft disease]]></article-title>
<source><![CDATA[Cathet Cardiovasc Intervent]]></source>
<year>2000</year>
<numero>50</numero>
<issue>50</issue>
<page-range>83-88</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Briguori]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[De Gregorio]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nishida]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Adamian]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Albiero]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tucci]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Di Mario]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Colombo A: Polytetrafluoroethylene-covered stent for the treatment of narrowings in aortic-coronary saphenous vein grafts]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>2000</year>
<numero>86</numero>
<issue>86</issue>
<page-range>343-346</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baldus]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Köster]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Elsner]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Walter]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
<name>
<surname><![CDATA[Arnold]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Auch-Schwelk]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rau]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Meinertz]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zehier]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Hamm]]></surname>
<given-names><![CDATA[CW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of aortocoronary vein graft lesions -with membrane-covered stents]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<numero>102</numero>
<issue>102</issue>
<page-range>2024-2027</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stankovic]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Presbítero]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Van den Branden]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Inglese]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cernigliaro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Nicolli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bartorelli]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Rubartelli]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Reifart]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Heyndrickx]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Saunamaki]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Morice]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Sgura]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Di Mario]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized evaluation of polytetrafluoroethylene covered stent in saphenous vein grafts (RECOVERS) trial]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2003</year>
<numero>108</numero>
<issue>108</issue>
<page-range>37-42</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schächinger]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Hamm]]></surname>
<given-names><![CDATA[CW]]></given-names>
</name>
<name>
<surname><![CDATA[Münzel]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Haude]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Baldus]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Grube]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Bonzel]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Konorza]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Köster]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Arnold]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Haase]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Probst]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Vom Dahe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Neumann]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mudra]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hennen]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Thiele]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Zeiher]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomized trial of polytetrafluoroethylene membrane-covered stents compared with conventional stents in aortocoronary vein grafts]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2003</year>
<numero>42</numero>
<issue>42</issue>
<page-range>1360-1369</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stone]]></surname>
<given-names><![CDATA[GW]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mehran]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[O'Shaughnessy]]></surname>
<given-names><![CDATA[Ch]]></given-names>
</name>
<name>
<surname><![CDATA[Midel]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Siegel]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[George]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Satler]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Raizner]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Negoita]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fahy]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Arjomand-Fard]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Lansky]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
</person-group>
<collab>Columbia University Medical Center</collab>
<collab>Cardiovascular Research Foundation</collab>
<article-title xml:lang="en"><![CDATA[A Prospective, Randomized U.S. Trial of the PTFE Covered JOSTENT for the Treatment of Diseased Saphenous Vein Grafts: The BARRICADE Trial]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2005</year>
<page-range>27A</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gazzand]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mintz]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Popma]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intravascular ultrasound diagnosis of a coronary artery pseudoaneurysm following percutaneous transluminal coronary angioplasty]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>1993</year>
<numero>125</numero>
<issue>125</issue>
<page-range>880-882</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burns]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Cowley]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Weschler]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronary aneurisms: a case report and review]]></article-title>
<source><![CDATA[Cathet Cardiovasc Diagn]]></source>
<year>1992</year>
<numero>27</numero>
<issue>27</issue>
<page-range>106-112</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alford]]></surname>
<given-names><![CDATA[WC]]></given-names>
</name>
<name>
<surname><![CDATA[Stoney]]></surname>
<given-names><![CDATA[WS]]></given-names>
</name>
<name>
<surname><![CDATA[Burrus]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recognition and operative management of patients with arteriosclerotic coronary artery aneurysms]]></article-title>
<source><![CDATA[Ann Thorac Surg]]></source>
<year>1976</year>
<numero>22</numero>
<issue>22</issue>
<page-range>317-321</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Kent]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Mintz]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Percutaneous transcatheter repair of a coronary aneurysm using a composite autologous cephalic vein-coated Palmaz-Schatz biliary stent]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1995</year>
<numero>76</numero>
<issue>76</issue>
<page-range>990-991</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Antonellis]]></surname>
<given-names><![CDATA[IP]]></given-names>
</name>
<name>
<surname><![CDATA[Patsilinakos]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Pamboukas]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Kranidis]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Prappa]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Filippatos]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Margaris]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
<name>
<surname><![CDATA[Siaterli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Tavernarakis]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Rokas]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sealing of coronary artery aneurysm by using a new stent graft]]></article-title>
<source><![CDATA[Cathet Cardiovasc Intervent]]></source>
<year>1999</year>
<numero>48</numero>
<issue>48</issue>
<page-range>96-99</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Briguori]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Sarais]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Sivieri]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Takagi]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Di Mario]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Polytetrafluoroethylene-covered stent and coronary artery aneurysms]]></article-title>
<source><![CDATA[Cathet Cardiovasc Intervent]]></source>
<year>2002</year>
<numero>55</numero>
<issue>55</issue>
<page-range>326-330</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Alfonso]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[Escaned]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Arias]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Macaya]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of a giant coronary aneurysm with a novel technique: Scaffolding (tunnel) stenting to support PTFE-covered stents: Insights from intravascular ultrasound catheter techniques for the treatment of aneurysms and Pseudoaneurysms]]></article-title>
<source><![CDATA[J Invasive Cardiol]]></source>
<year>2002</year>
<volume>14</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>273-276</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ajluni]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Glazier]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Blankenship]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Perforation after percutaneous coronary interventions: clinical, angiographic, and therapeutic observations]]></article-title>
<source><![CDATA[Cathet Cardiovasc Diagn]]></source>
<year>1994</year>
<numero>32</numero>
<issue>32</issue>
<page-range>206-212</page-range></nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sanmartín]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Goicolea]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ruíz-Salmeron]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Mantilla]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Sterling]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Meneses]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Calvo]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronary perforation as a potential complication derived from coronary thrombectomy with the X-Sizer device]]></article-title>
<source><![CDATA[Cathet Cardiovasc Intervent]]></source>
<year>2002</year>
<numero>56</numero>
<issue>56</issue>
<page-range>378-382</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hall]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Nakamura]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Maiello]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Factors associated with procedural complications during high pressure optimized Palmaz-Schatz intracoronary stent implantation]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1994</year>
<numero>90</numero>
<issue>90</issue>
<page-range>1-612</page-range></nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nageh]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Thomas]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Coronary Artery Rupture treated with a polytetrafluoroethylene-coated stent]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2000</year>
<volume>342</volume>
<numero>25</numero>
<issue>25</issue>
<page-range>1922-1923</page-range></nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albiero]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Nishida]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Corvaja]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Vaghetti]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Di Mario]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Left internal mammary artery graft perforation repair using polytetra-fluoroethylene covered stents]]></article-title>
<source><![CDATA[Cathet Cardiovasc Intervent]]></source>
<year>2000</year>
<numero>51</numero>
<issue>51</issue>
<page-range>78-82.</page-range></nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Briguori]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Nishida]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Anzuini]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Di Mario]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Grube]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Emergency polytetrafluo-roethylene covered stent implantation to treat coronary ruptures]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2000</year>
<numero>102</numero>
<issue>102</issue>
<page-range>3028-3031</page-range></nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baim]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wahr]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[George]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Leon]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Greenberg]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cutlip]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Kaya]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Popma]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ho]]></surname>
<given-names><![CDATA[KKL]]></given-names>
</name>
<name>
<surname><![CDATA[Kuntz]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized Trial of a Distal Embolic Protection Intervention of Saphenous Vein Aorto-Coronary Bypass Grafts]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2002</year>
<numero>105</numero>
<issue>105</issue>
<page-range>1285-90</page-range></nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stone]]></surname>
<given-names><![CDATA[GW]]></given-names>
</name>
<name>
<surname><![CDATA[Rogers]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Hermiller]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Feldman]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Haber]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Masud]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ramee]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Cox]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized comparison of distal protection with a filter based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>2003</year>
<numero>108</numero>
<issue>108</issue>
<page-range>548-553</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
