<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-9532</journal-id>
<journal-title><![CDATA[Revista mexicana de ingeniería biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. ing. bioméd]]></abbrev-journal-title>
<issn>0188-9532</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Mexicana de Ingeniería Biomédica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-95322017000100363</article-id>
<article-id pub-id-type="doi">10.17488/rmib.38.1.32</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Análisis de los espectros de absorción de las películas radiocrómicas EBT2 y EBT3]]></article-title>
<article-title xml:lang="en"><![CDATA[Analysis of the absorption spectra of EBT2 and EBT3 radiochromic films]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[León-Marroquín]]></surname>
<given-names><![CDATA[E.Y.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
<xref ref-type="aff" rid="Aaf"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Camacho-López]]></surname>
<given-names><![CDATA[M.A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-Garduño]]></surname>
<given-names><![CDATA[O.A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Herrera-González]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Villarreal-Barajas]]></surname>
<given-names><![CDATA[J.E.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martínez-Quiroz]]></surname>
<given-names><![CDATA[C.A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cruz-Pérez]]></surname>
<given-names><![CDATA[D. De la]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Jiménez-Avilés]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Autónoma del Estado de México Facultad de Medicina ]]></institution>
<addr-line><![CDATA[ Edo. México]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Instituto Nacional de Neurología y Neurocirugía  ]]></institution>
<addr-line><![CDATA[ Cd. México]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,University of Calgary Department of Oncology Department of Physics and Astronomy]]></institution>
<addr-line><![CDATA[Calgary AB ]]></addr-line>
<country>Canada</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<volume>38</volume>
<numero>1</numero>
<fpage>363</fpage>
<lpage>371</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-95322017000100363&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-95322017000100363&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-95322017000100363&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen:  Objetivo:  Analizar los espectros de absorción neta de las películas radiocrómicas EBT2 y EBT3 para describir su influencia en el comportamiento de las curvas de dosis-respuesta.  Metodología:  Las películas se irradiaron en un acelerador lineal de 6 MV. La obtención de los espectros de absorción neta se realizó con espectrofotómetro UV/VIS. Las curvas de dosis-respuesta se obtuvieron con un escáner, un láser He-Ne y un espectrofotómetro.  Resultados:  El espectro de absorción de las EBT2 muestra tres bandas de absorción centradas que conservan la posición y aumentan su intensidad en función de la dosis, sin embargo, este comportamiento no se observa en las películas EBT3. La curva dosis-respuesta muestra la máxima sensibilidad utilizando el espectrofotómetro, pero no muestra un comportamiento definido.  Implicaciones:  Generación de nuevos conocimientos para la creación de nuevos sistemas ópticos capaces de amplificar la sensibilidad de la respuesta de las películas.  Originalidad:  Mostrar la correlación entre los espectros de absorción neta y su influencia en las curvas dosis-respuesta en tres diferentes sistemas ópticos.  Conclusiones:  El comportamiento de los espectros de absorción aunado al comportamiento de las curvas dosis-respuesta nos ayuda a descartar el uso de sistemas ópticos que no garanticen un uso clínico confiable.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract:  Objective:  To analyze the net absorption spectra of EBT2 and EBT3 radiochromic films to describe their influence on the behavior of dose-response curves.  Methodology:  The films were irradiated in a linear accelerator of 6 MV. The net absorption spectra were obtained with a UV / VIS spectrophotometer. Dose-response curves were obtained with a scanner, a He-Ne laser and a spectrophotometer.  Results:  The absorption spectrum of the EBT2 shows three focused absorption bands that retain position and increase their intensity as a function of dose, however, this behavior is not observed in EBT3 films. The dose-response curve shows maximum sensitivity using the spectrophotometer, but does not show a defined behavior.  Implications:  Generation of new knowledge for the creation of new optical systems capable of amplifying the responsiveness of the films.  Originality:  Show the correlation between net absorption spectra and their influence on dose-response curves in three different optical systems.  Conclusions:  The behavior of absorption spectra combined with the behavior of the dose-response curves helps to discard the use of optical systems that do not guarantee a reliable clinical use.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Espectro de absorción]]></kwd>
<kwd lng="es"><![CDATA[espectrofotómetro]]></kwd>
<kwd lng="es"><![CDATA[película radiocrómica]]></kwd>
<kwd lng="en"><![CDATA[Absorption spectrum]]></kwd>
<kwd lng="en"><![CDATA[spectrophotometer]]></kwd>
<kwd lng="en"><![CDATA[radiochromic film]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>[1]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Casanova-Borca]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Pasquino]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Russo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Grosso]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Cante]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Sciacero]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification]]></article-title>
<source><![CDATA[J Appl Clin Med Phys.]]></source>
<year>2013</year>
<volume>14</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>158-71</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>[2]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lewis]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Micke]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan]]></article-title>
<source><![CDATA[Med Phys.]]></source>
<year>2012</year>
<volume>39</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>6339-50</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>[3]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aland]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kairn]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kenny]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance]]></article-title>
<source><![CDATA[Australas Phys Eng Sci Med.]]></source>
<year>2011</year>
<volume>34</volume>
<page-range>251-60</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>[4]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devic]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Seuntjens]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sham]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Podgorsak]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidtlein]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Kirov]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Precise radiochromic film dosimetry using a flat-bed document scanner]]></article-title>
<source><![CDATA[Med. Phys.]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>2245-53</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>[5]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devic]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Tomic]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Pang]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Seuntjens]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Podgorsak]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Soares]]></surname>
<given-names><![CDATA[CG]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Absorption spectroscopy of EBT model GAFCHROMICTM film]]></article-title>
<source><![CDATA[Med. Phys.]]></source>
<year>2007</year>
<volume>34</volume>
<page-range>112-8</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>[6]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devic]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[YZ]]></given-names>
</name>
<name>
<surname><![CDATA[Tomic]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Podgorsak]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Sensitivity of linear CCD array based film scanners used for film dosimetry]]></article-title>
<source><![CDATA[Med Phys.]]></source>
<year>2006</year>
<volume>33</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>3993-6</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>[7]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[León-Marroquín]]></surname>
<given-names><![CDATA[EY]]></given-names>
</name>
<name>
<surname><![CDATA[Camacho-López]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[García-Garduño]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera-González]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Villarreal-Barajas]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez-Fuentes]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Spectral analysis of the EBT3 radiochromic film irradiated with 6 MV x-ray radiation]]></article-title>
<source><![CDATA[Radiat. Meas.]]></source>
<year>2016</year>
<volume>89</volume>
<page-range>82-8</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>[8]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[León-Marroquín]]></surname>
<given-names><![CDATA[EY]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera-González]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Camacho-López]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Villarreal-Barajas]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[García-Garduño]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of the uncertainty in a EBT3 film dosimetry system utilizing net optical density]]></article-title>
<source><![CDATA[J. Appl. Clin. Med. Phys.]]></source>
<year>2016</year>
<volume>17</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>466-81</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>[9]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devic]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Radiochromic film dosimetry: Past, present and future]]></article-title>
<source><![CDATA[Phys. Med.]]></source>
<year>2011</year>
<volume>27</volume>
<page-range>122-34</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>[10]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hecht]]></surname>
</name>
</person-group>
<source><![CDATA[Óptica]]></source>
<year>2000</year>
<page-range>77-8</page-range><publisher-name><![CDATA[Pearson]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<label>[11]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Butson]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[PKN]]></given-names>
</name>
<name>
<surname><![CDATA[Alnawaf]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays]]></article-title>
<source><![CDATA[Australas. Phys. Eng. Sci. Med.]]></source>
<year>2009</year>
<volume>32</volume>
<page-range>196-202</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>[12]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mack]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mack]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Weltz]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Sxheib]]></surname>
<given-names><![CDATA[SG]]></given-names>
</name>
<name>
<surname><![CDATA[Böttcher]]></surname>
<given-names><![CDATA[HD]]></given-names>
</name>
<name>
<surname><![CDATA[Seifert]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[High precision film dosimetry with GafChromic films for quality assurance especially when using small fields]]></article-title>
<source><![CDATA[Med. Phys.]]></source>
<year>2003</year>
<volume>30</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>2399-409</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>[13]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Butson]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[PKN]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Absorption spectra variations of EBT radiochromic film from radiation exposure]]></article-title>
<source><![CDATA[Phys. Med. Biol.]]></source>
<year>2005</year>
<volume>50</volume>
<page-range>N135-40</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>