<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-9532</journal-id>
<journal-title><![CDATA[Revista mexicana de ingeniería biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. ing. bioméd]]></abbrev-journal-title>
<issn>0188-9532</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Mexicana de Ingeniería Biomédica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-95322011000100003</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Magnetic characterization of solid food to gastric emptying studies by mechanical-magnetogastrography assessment]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Córdova-Fraga]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodriguez]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[De la Roca-Chiapas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Solorio]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Guanajuato Departamento de Ingeniería Física ]]></institution>
<addr-line><![CDATA[León Guanajuato]]></addr-line>
<country>México</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Instituto Mexicano del Seguro Social Unidad Médica de Alta Especialidad ]]></institution>
<addr-line><![CDATA[León Guanajuato]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>07</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>07</month>
<year>2011</year>
</pub-date>
<volume>32</volume>
<numero>1</numero>
<fpage>20</fpage>
<lpage>24</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-95322011000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-95322011000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-95322011000100003&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Mechanical-Magnetogastrography (M-MGG) is a technique that has been used to measure gastric emptying in healthy subjects and patients with gastrointestinal pathologies. This has allowed implementing a non-invasive technology, free of ionizing-radiation and it may be used in diagnostic tests in clinical medicine. The characterization of a phantom which has a magnetic behavior similar to that observed in gastric emptying studies carried out in persons is presented. A fluxgate magnetometer was used to record the signal in a magnetic unshielded room. Phantom included nine identical deposits prepared with magnetite, Fe3O4 and flour. The behavior of the experiment is identical to studies previously reported in evaluations of healthy people and patients.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[La magnetogastrografía mecánica (M-MGG) es una técnica que ha sido usada para medir el vaciado gástrico en pacientes sanos y pacientes con patologías gastrointestinales. Esto ha permitido la implementación de una tecnología no invasiva, libre de radiación ionizante que puede ser utilizada para pruebas clínicas en medicina. En este artículo, la caracterización de un «phantom» que tiene un comportamiento magnético similar a los estudios realizados para el proceso de vaciado gástrico es presentada. Un magnetómetro de flujo magnético fue utilizado para registrar la señal en un cuarto sin aislamiento magnético. El «phantom» incluyó depósitos idénticos preparados con magnetita, Fe3O4 y flúor. El comportamiento de los experimentos obtenidos es idéntico a estudios previamente reportados en las evaluaciones de personas sanas y pacientes con alguna patología.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Mechanical-magnetogastrography]]></kwd>
<kwd lng="en"><![CDATA[gastric emptying]]></kwd>
<kwd lng="en"><![CDATA[magnetic stimulator]]></kwd>
<kwd lng="es"><![CDATA[Magnetogastrografía mecánica]]></kwd>
<kwd lng="es"><![CDATA[vaciado gástrico]]></kwd>
<kwd lng="es"><![CDATA[estimulador magnético]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="justify"><font face="verdana" size="4">Art&iacute;culo de investigaci&oacute;n original</font></p>     <p align="justify">&nbsp;</p>      <p align="center"><font face="verdana" size="4"><b>Magnetic characterization of solid food to gastric emptying studies by mechanical&#45;magnetogastrography assessment</b></font></p>     <p align="center">&nbsp;</p>  	    <p align="center"><b><font face="verdana" size="2">C&oacute;rdova&#45;Fraga T*, Rodriguez D*, De la Roca&#45;Chiapas JM*, Sosa M*, Hern&aacute;ndez MA**, Vargas M*, Solorio SE**, Bernal JJ*</font></b><font face="verdana" size="2"></font></p> 	    <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><i>* Departamento de Ingenier&iacute;a F&iacute;sica&#45;DCI, Universidad de Guanajuato Campus Le&oacute;n.</i></font></p>  	    <p align="justify"><i><font face="verdana" size="2">** Unidad M&eacute;dica de Alta Especialidad IMSS, Cl&iacute;nica T&#45;1 Le&oacute;n, Guanajuato.</font></i><font face="verdana" size="2"></font></p>     <p align="justify">&nbsp;</p>      ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Correspondence: </b>    <br> </font><font face="verdana" size="2">Teodoro C&oacute;rdova&#45;Fraga,     <br> </font><font face="verdana" size="2">E&#45;mail: <a href="mailto:theo@fisica.ugto.mx">theo@fisica.ugto.mx</a>.     <br> Tel. 52 (477) 7885100.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2">Received article: 26/may/2010.    <br> </font><font face="verdana" size="2"> Accepted article: 14/february/2011.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><b>ABSTRACT</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Mechanical&#45;Magnetogastrography (M&#45;MGG) is a technique that has been used to measure gastric emptying in healthy subjects and patients with gastrointestinal pathologies. This has allowed implementing a non&#45;invasive technology, free of ionizing&#45;radiation and it may be used in diagnostic tests in clinical medicine. The characterization of a phantom which has a magnetic behavior similar to that observed in gastric emptying studies carried out in persons is presented. A fluxgate magnetometer was used to record the signal in a magnetic unshielded room. Phantom included nine identical deposits prepared with magnetite, Fe<sub>3</sub>O<sub>4</sub> and flour. The behavior of the experiment is identical to studies previously reported in evaluations of healthy people and patients.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Key Words: </b>Mechanical&#45;magnetogastrography, gastric emptying, magnetic stimulator.</font></p>     <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><b>RESUMEN</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La magnetogastrograf&iacute;a mec&aacute;nica (M&#45;MGG) es una t&eacute;cnica que ha sido usada para medir el vaciado g&aacute;strico en pacientes sanos y pacientes con patolog&iacute;as gastrointestinales. Esto ha permitido la implementaci&oacute;n de una tecnolog&iacute;a no invasiva, libre de radiaci&oacute;n ionizante que puede ser utilizada para pruebas cl&iacute;nicas en medicina. En este art&iacute;culo, la caracterizaci&oacute;n de un &laquo;phantom&raquo; que tiene un comportamiento magn&eacute;tico similar a los estudios realizados para el proceso de vaciado g&aacute;strico es presentada. Un magnet&oacute;metro de flujo magn&eacute;tico fue utilizado para registrar la se&ntilde;al en un cuarto sin aislamiento magn&eacute;tico. El &laquo;phantom&raquo; incluy&oacute; dep&oacute;sitos id&eacute;nticos preparados con magnetita, Fe<sub>3</sub>O<sub>4</sub> y fl&uacute;or. El comportamiento de los experimentos obtenidos es id&eacute;ntico a estudios previamente reportados en las evaluaciones de personas sanas y pacientes con alguna patolog&iacute;a.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Palabras clave: </b>Magnetogastrograf&iacute;a mec&aacute;nica, vaciado g&aacute;strico, estimulador magn&eacute;tico.</font></p> 	    <p align="justify">&nbsp;</p> 	    <p align="justify"><font face="verdana" size="2"><b>INTRODUCTION</b></font></p>      <p align="justify"><font face="verdana" size="2">Biomagnetic gastrointestinal (GI) system assessment began in the late fifties and early sixties<sup>1,2</sup>. However, these biomagnetic devices and techniques began to expand their applications until the early seventies </font><font face="verdana" size="2">of the past century. Cohen in 1969 used the magnetometer to measure the direct current fields of many parts of the body, and established the first orders of magnitude depending on the biomagnetic source registered<sup>3&#45;5</sup>. In the seventies, further studies of the GI system were published<sup>6&#45;8</sup>. This technique, applied </font><font face="verdana" size="2">to GI system studies, has been growing since then to date<sup>9&#45;15</sup>. In this regard, a significant progress has been made in the techniques for gastric emptying assessment, including theoretical and experimental developments to incorporate new magnetometers that work at room temperature, with high sensitivity devices to record magnetic fields around nT, so that, with appropriate quantities of oral contrast agent, the biomagnetic signal intensity is increased in that order.</font></p>     <p align="justify"><font face="verdana" size="2">Particularly, in previous studies<sup>9&#45;12</sup> it has evaluated the gastric emptying half&#45;time to predict the behavior of ingested food and associate it with the behavior of the drain on health<sup>12</sup> and the disease<sup>10</sup>, it has been used as food semisolid and solid<sup>15</sup> and it has been gotten similar results to scintigraphy, it was also used the same type of test food in order to make studies comparable. Which one was done in order to create a technological development that is a diagnostic option with a lot of advantages because of it is not invasive, low cost, and it lacks of ionization radiation, such in all studies were assumed they were performed close to use of scintigraphy and a decaying behavior has been tested the sensors have a good signal to noise ratio, which measure the different magnetic intensities, nevertheless, it has not been done, so far it is known, or there are not laboratory experimental evidence showing that what is being measured is raised at the theoretical level, hence the importance of a study of phantoms which may be fitted with gastric emptying and that results in an average time of gastric emptying similar to that found in previous studies.</font></p>  	    <p align="justify"><font face="verdana" size="2">Recently in our laboratory, M&#45;MGG technique has been used in different studies, to evaluate the gastric segment peristaltic activity, the colon transit time in different phases of menstrual cycle and motility evaluation in patients with functional dyspepsia<sup>10</sup> and healthy subjects<sup>11&#45;14</sup> to reproducibility evaluation. Several studies has been done in order to assess the gastric emptying through magnetic tracer diluted in semi&#45;solid contrast media, in both healthy subjects and gastro paresis patients<sup>6,7,14</sup>. The authors analyzed the magnetic signalof magnetictracers mixed in a solid food (yogurt) to measure gastric emptying using M&#45;MGG in male healthy subjects (defined as subject without GI symptoms or known GI disease). As long as, others researches have reported in preliminary studies, motility, nutritional value, taste perception and possible side effects of solid food contrast agent<sup>15</sup>.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">The aim of this study is to evaluate the magnetic properties of solid test meal by using an experimen</font><font face="verdana" size="2">tal phantom performed for this purpose (containers with food test). The theoretical importance of this investigation was to verify the gastric&#45;emptying rate of solid foods, similar to those reported by other authors, through a controlled experiment.</font></p>     <p align="justify"><font face="verdana" size="2">It is pretend that the food prepared and characterized in our laboratory could be used for further studies to gastric emptying time assessment using M&#45;MMG technique, which represents an alternative simple and novel similar to other diagnosis methods employed in clinical medicine evaluation.</font></p>     <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><b>MATERIAL AND METHODS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">A magnetic stimulator constructed and characterized in our laboratory was used in this study, this device whose results have been previously published<sup>11,12</sup>, was implemented with two identical coils assembled in a Helmholtz coils array, these two coils are plugged in series with a capacitor bank and fed with electrical line at 220 v. This configuration produces a nearly homogeneous magnetic field with intensity around 32 mT in the central region of the system<sup>16</sup>. This magnetic flux density is generated with a discharge of a capacitance bank, in 17 ms, with a capacitance value of 46 mF (<a href="#f1">Figure 1</a>). It is enough strong to magnetize the particles of magnetite contained in the food, and then, it produces magnetic field in order of nT, which is recorded with a fluxgate magnetometer sensor.</font></p> 	    <p align="center"><a name="f1"></a><img src="../img/revistas/rmib/v32n1/a3f1.jpg"></p>      <p align="justify"><font face="verdana" size="2">Phantoms were prepared in nine identical plastic cylindrical deposits, with 5.6 &plusmn; 0.1 cm diameter and 3.0 &plusmn; 0.1 cm height. These containers were prepared with 1 g of magnetite (Fe<sub>3</sub>O<sub>4</sub> ) in 9 g of flour, the weight container of magnetite was 22.5 &plusmn; 0.1 g. The nine containers were placed in different configurations into magnetization system. The settings used are shown in <a href="../img/revistas/rmib/v32n1/a3f2.jpg" target="_blank">Figure 2</a>, the containers were formed into three columns, standing just above the fluxgate magnetometers. The columns were placed, with respect to the sensors, in four different </font><font face="verdana" size="2">positions: The first assay consisted in to place the columns forming a triangle between the two sensors. In the second assay, the columns are placed above one sensor. The third configuration was the same as previous one, except that the columns were placed on the other sensor. Finally, the columns were placed forming a straight line between the two sensors.</font></p>     <p align="justify"><font face="verdana" size="2">Once each configuration was established, the capacitors were charged at 100 %, in 60 s and then they were discharged in 17 ms, this guarantees the current flow through coils to generate a magnetic pulse around 32 mT.</font></p>  	    <p align="justify"><font face="verdana" size="2">Recordings were made during one minute at a sampling frequency of 30 Hz, so 1,800 samples were measured, then they were averaged and this magnetic field value was considerate for the corresponding sample in each case. After the first measurement, a container was removed in order to reduce the amount of ferromagnetic material in the phantom and the process was repeated, that is, loading, unloading and measurement of the magnetic field strength, as has been described previously. It is important to emphasize that this characterization was performed in a non&#45;magnetic shielding room.</font></p>  	    <p align="justify"><font face="verdana" size="2">The function used in the gastric emptying, in order to adjust the experimental data, has been reported previously<sup>10</sup> and is described as an exponential decay function</font></p>  	    ]]></body>
<body><![CDATA[<p align="center"><img src="../img/revistas/rmib/v32n1/a3e1.jpg"></p>     <p align="justify"><font face="verdana" size="2">Where <i>t<sub>&#189;</sub> = &pi;<sub>0</sub></i> In (2) is the gastric emptying half time.</font></p>  	    <p align="justify"><font face="verdana" size="2">Additional to characterization, measurements of gastric emptying test food with M&#45;MGGtechnique were made in people who agree to take part in the study. Values were obtained in both healthy subjects and diabetics with gastroparesis syndrome for 100 minutes, in intervals of 10 minutes.</font></p> 	    <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><b>RESULTS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">The four experimental configurations used in this study were similar, so they presented identical behavior. Results of the magnetic variations corresponding to the first two experiments are shown in <a href="#f3">Figures 3</a> and <a href="#f4">4</a>. The graphics show the magnetization value measured by M&#45;MGG <i>versus</i> time as the containers are removed from the phantom. Continues curve represents the exponential data fit according to equation (1). It is showed that the removal of material only affects the magnitude of the overall signal and simulates the emptying of ingested material in the process of intake, processing and disposal of food in the stomach.</font></p> 	    <p align="center"><a name="f3"></a><img src="../img/revistas/rmib/v32n1/a3f3.jpg"></p> 	    <p align="center"><a name="f4"></a><img src="../img/revistas/rmib/v32n1/a3f4.jpg"></p>         <p align="justify"><font face="verdana" size="2">In order to show the gastric emptying evaluated in human subjects, <a href="#f5">Figure 5</a> exhibits the M&#45;MGG evaluation in a healthy volunteerwho ingestedan oral solid food similar to that described previously.. As long as, <a href="#f6">Figure 6</a> shows the results in a patient with gastroparesis disorder.</font></p>     <p align="center"><a name="f5"></a><img src="../img/revistas/rmib/v32n1/a3f5.jpg"></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f6"></a><img src="../img/revistas/rmib/v32n1/a3f6.jpg"></p>     <p align="center">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><b>DISCUSSION</b></font></p>     <p align="justify"><font face="verdana" size="2">Magnetic material placed in a phantom had a decaying behavior similar to oral magnetic contrast in the gastric emptying in subject and both exhibit an exponential decay fitting modeling by equation (1). The magnetic intensity decreases exponentially due to a decreasing into the food volume. Our findings provide enough information to continue using this method to infer gastric emptying half&#45;time<sup>11,12</sup>.</font></p>     <p align="justify"><font face="verdana" size="2">Experimental results of meal magnetization show that the change is consistent with previously reported values<sup>11,12,15</sup>, because of the magnetic intensity begins to drop as biomagnetic material was removed. Also, our results show that solid food test is useful for measuring gastric emptying in healthy subjects<sup>15</sup>. Also, Figure 5 shows a good agreement with theoretical model of gastric emptying in healthy subject.</font></p>     <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><b>CONCLUSIONS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Althoughanalysisof GI diseaseadjusted models was not our study purpose, based on our results we conclude that magnetization decreased almost linearly during the first 50 minutes of starting the analysis, with a subsequent fluctuation unclear, in patients with gastroparesis syndrome. To verify this protocol could be interesting to reduce the acquisition sampling interval to times shorter than 5 minutes, thus obtaining a greater number of points for the adjustment.</font></p>  	    <p align="justify"><font face="verdana" size="2">Finally, this solid food test has similar characteristics to conventional meal test employed in scintigraphy, whose technique is considered gold standard method to assess gastric emptying in certain GI disorder. Also, among advantages of M&#45;MGG is the fact that it is a non&#45;ionizing radiation technique; it is a non&#45;invasive so it could be implemented in our hospitals as a routinely GI alternative diagnosis technique, and it can be used in the monitoring of dyspepsia syndrome and gastroparesis due to diabetes mellitus disease.</font></p>  	    <p align="justify">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>ACKNOWLEDGMENTS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Authors want to thank CONACYT and DAIP for financial support under grant numbers J50182 and 000017/10.</font></p> 	    <p align="justify">&nbsp;</p>      <p align="justify"><font face="verdana" size="2"><b>REFERENCES</b></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">1.&nbsp;Wenger MA, Engel BT, Clemens TL and Cullen TD. Stomach motility in man as recorder by the magnetometer method. Gastroenterology 1961; 41: 479&#45;85.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505486&pid=S0188-9532201100010000300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">2.&nbsp;Wenger MA, Henderson EB, Dinnin JS. Magnetometer method for recording gastric motility. Science 1957; 125: 192&#45;195.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505488&pid=S0188-9532201100010000300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">3.&nbsp;Cohen D. Ferromagnetic contamination in the lungs and other organs of the human body. Science 1973; 180: 743748.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505490&pid=S0188-9532201100010000300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">4.&nbsp;Cohen D. Detection and analysis of magnetic fields produced by bioelectric currents in humans. Journal of Applied Physics 1969; 40: 1046&#45;1048.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505492&pid=S0188-9532201100010000300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">5.&nbsp;Cohen D, Edelsack EA, Zimmerman JE. Magnetocardiogram taken inside a shielded room with a superconducting point&#45;contact magnetometer. Appl Phys Lett 1970; 16: 278&#45;280.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505494&pid=S0188-9532201100010000300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">6.&nbsp;Benmair Y, Dreyfuss F, Fischel B, Frei EH, Gilat T. Study of gastric emptying using a ferromagnetic tracer. Gastroenterology 1977; 73: 1041&#45;1045.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505496&pid=S0188-9532201100010000300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">7.&nbsp;Benmair Y, Fischel B, Frei EH, Gilat T. Evaluation of a magnetic method for the measurement of small intestine transit time. American Journal of Gastroenterology 1977; 68: 470&#45;475.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505498&pid=S0188-9532201100010000300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">8.&nbsp;Frei EH, Benmayr Y, Yerashlmi S, Dreyfuss F. Measurements of the emptying of the stomach with a magnetic tracer. IEEE Trans Mag 1970; 6: 348&#45;349.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505500&pid=S0188-9532201100010000300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">9.&nbsp;C&oacute;rdova&#45;Fraga T, Carneiro AA, De Araujo DB, Oliveira RB, Sosa M, Baffa O. Spatiotemporal evaluation of human colon motility using three&#45;axis fluxgates and magnetic markers. Med Biol Eng Comput 2005; 43: 712&#45;715.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505502&pid=S0188-9532201100010000300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">10.&nbsp;De la Roca&#45;Chiapas JM, C&oacute;rdova&#45;Fraga T, Zarate A, Solis Ortiz S, Bernal JJ, Vargas M, Sosa M. Magnetogastrography </font><font face="verdana" size="2">in patients with functional dyspepsia. Biomagnetism: Interdisciplinary Research and Exploration Proceedings of the 16<sup>th</sup> International Conference on Biomagnetism, Hokkaido University Press (Japan). 2008: 15&#45;17.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505504&pid=S0188-9532201100010000300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">11.&nbsp;C&oacute;rdova FT, Guti&eacute;rrez JG, Sosa AM, Vargas LF, Bernal AJJ. Gastric activity studies using a magnetic tracer. Physiol Meas 2004; 25(5): 261&#45;270.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505506&pid=S0188-9532201100010000300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">12.&nbsp;De la Roca CJM, Hern&aacute;ndez SE, Sol&iacute;s MS, Sosa AM, C&oacute;rdova FT. Magnetogastrography (MGG) reproducibility assessments of gastric emptying on healthy subjects. Physiol Meas 2007; </font><font face="verdana" size="2">28(2): 175&#45;183.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505508&pid=S0188-9532201100010000300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">13.&nbsp;Carneiro AA, Baffa O, Oliveira RB. Study of stomach motility using the relaxation of magnetic tracers. Phys Med Biol 1999; 44(7): 1691&#45;1697.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505510&pid=S0188-9532201100010000300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">14.&nbsp;Forsman M. Intragastric movement assessment by measurement magnetic field decay of magnetized tracers particles in a solid meal. Med Biol Eng Comput 2000; 38(2): 169&#45;174.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505512&pid=S0188-9532201100010000300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">15.&nbsp;Reynaga&#45;Ornelas MG, De la Roca&#45;Chiapas JM, Cordova&#45;Fraga T, Bernal JJ, Sosa M. Solid test meal to measure the gastric emptying with magnetogastrography. AIP Conference Proceedings, 2008; 1032: 246&#45;248.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505514&pid=S0188-9532201100010000300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">16.&nbsp;Walter Greiner. Classical Electromagnetics. Springer&#45;Verlag (USA), 1996.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8505516&pid=S0188-9532201100010000300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p> 	    <p align="justify">&nbsp;</p> 	    <p align="justify"><font size="2" face="verdana"><b>Nota</b></font></p>         <p align="justify"><font face="verdana" size="2">Este art&iacute;culo tambi&eacute;n puede ser consultado en versi&oacute;n completa en: <a href="http://www.medigraphic.com/ingenieriabiomedica/" target="_blank">http://www.medigraphic.com/ingenieriabiomedica/</a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wenger]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Engel]]></surname>
<given-names><![CDATA[BT]]></given-names>
</name>
<name>
<surname><![CDATA[Clemens]]></surname>
<given-names><![CDATA[TL]]></given-names>
</name>
<name>
<surname><![CDATA[Cullen]]></surname>
<given-names><![CDATA[TD.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stomach motility in man as recorder by the magnetometer method]]></article-title>
<source><![CDATA[Gastroenterology]]></source>
<year>1961</year>
<volume>41</volume>
<page-range>479-85</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wenger]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Henderson]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Dinnin]]></surname>
<given-names><![CDATA[JS.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Magnetometer method for recording gastric motility]]></article-title>
<source><![CDATA[Science]]></source>
<year>1957</year>
<volume>125</volume>
<page-range>192-195</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ferromagnetic contamination in the lungs and other organs of the human body]]></article-title>
<source><![CDATA[Science]]></source>
<year>1973</year>
<volume>180</volume>
<page-range>743748</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Detection and analysis of magnetic fields produced by bioelectric currents in humans]]></article-title>
<source><![CDATA[Journal of Applied Physics]]></source>
<year>1969</year>
<volume>40</volume>
<page-range>1046-1048</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Edelsack]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Zimmerman]]></surname>
<given-names><![CDATA[JE.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Magnetocardiogram taken inside a shielded room with a superconducting point-contact magnetometer]]></article-title>
<source><![CDATA[Appl Phys Lett]]></source>
<year>1970</year>
<volume>16</volume>
<page-range>278-280</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benmair]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Dreyfuss]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fischel]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Frei]]></surname>
<given-names><![CDATA[EH]]></given-names>
</name>
<name>
<surname><![CDATA[Gilat]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study of gastric emptying using a ferromagnetic tracer]]></article-title>
<source><![CDATA[Gastroenterology]]></source>
<year>1977</year>
<volume>73</volume>
<page-range>1041-1045</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benmair]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Fischel]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Frei]]></surname>
<given-names><![CDATA[EH]]></given-names>
</name>
<name>
<surname><![CDATA[Gilat]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of a magnetic method for the measurement of small intestine transit time]]></article-title>
<source><![CDATA[American Journal of Gastroenterology]]></source>
<year>1977</year>
<volume>68</volume>
<page-range>470-475</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frei]]></surname>
<given-names><![CDATA[EH]]></given-names>
</name>
<name>
<surname><![CDATA[Benmayr]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yerashlmi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dreyfuss]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurements of the emptying of the stomach with a magnetic tracer]]></article-title>
<source><![CDATA[IEEE Trans Mag]]></source>
<year>1970</year>
<volume>6</volume>
<page-range>348-349</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Córdova-Fraga]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Carneiro]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[De Araujo]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Baffa]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Spatiotemporal evaluation of human colon motility using three-axis fluxgates and magnetic markers]]></article-title>
<source><![CDATA[Med Biol Eng Comput]]></source>
<year>2005</year>
<volume>43</volume>
<page-range>712-715</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De la Roca-Chiapas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Córdova-Fraga]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zarate]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Solis Ortiz]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Magnetogastrography in patients with functional dyspepsia]]></article-title>
<source><![CDATA[Biomagnetism: Interdisciplinary Research and Exploration Proceedings of the 16th International Conference on Biomagnetism]]></source>
<year>2008</year>
<page-range>15-17</page-range><publisher-name><![CDATA[Hokkaido University Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Córdova]]></surname>
<given-names><![CDATA[FT]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[LF]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[AJJ.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Gastric activity studies using a magnetic tracer]]></article-title>
<source><![CDATA[Physiol Meas]]></source>
<year>2004</year>
<volume>25</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>261-270</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De la Roca]]></surname>
<given-names><![CDATA[CJM]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Solís]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Córdova]]></surname>
<given-names><![CDATA[FT.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Magnetogastrography (MGG) reproducibility assessments of gastric emptying on healthy subjects]]></article-title>
<source><![CDATA[Physiol Meas]]></source>
<year>2007</year>
<volume>28</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>175-183</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carneiro]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Baffa]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[RB.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study of stomach motility using the relaxation of magnetic tracers]]></article-title>
<source><![CDATA[Phys Med Biol]]></source>
<year>1999</year>
<volume>44</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1691-1697</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Forsman]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intragastric movement assessment by measurement magnetic field decay of magnetized tracers particles in a solid meal]]></article-title>
<source><![CDATA[Med Biol Eng Comput]]></source>
<year>2000</year>
<volume>38</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>169-174</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reynaga-Ornelas]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[De la Roca-Chiapas]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Cordova-Fraga]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solid test meal to measure the gastric emptying with magnetogastrography]]></article-title>
<source><![CDATA[AIP Conference Proceedings]]></source>
<year>2008</year>
<volume>1032</volume>
<page-range>246-248</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greiner]]></surname>
<given-names><![CDATA[Walter]]></given-names>
</name>
</person-group>
<source><![CDATA[Classical Electromagnetics]]></source>
<year>1996</year>
<publisher-name><![CDATA[Springer-Verlag]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
