<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2306-4102</journal-id>
<journal-title><![CDATA[Acta ortopédica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Acta ortop. mex]]></abbrev-journal-title>
<issn>2306-4102</issn>
<publisher>
<publisher-name><![CDATA[Colegio Mexicano de Ortopedia y Traumatología A.C.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2306-41022014000500010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Tribología moderna en artroplastía total de cadera: pros y contras]]></article-title>
<article-title xml:lang="en"><![CDATA[Modern tribology in total hip arthroplasty: pros and cons]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gómez-García]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Ángeles Mocel Clínica de Osteoartritis del Hospital Ángeles Pedregal ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>10</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>10</month>
<year>2014</year>
</pub-date>
<volume>28</volume>
<numero>5</numero>
<fpage>319</fpage>
<lpage>335</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S2306-41022014000500010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S2306-41022014000500010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S2306-41022014000500010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los productos de desgaste y las reacciones adversas que se generan en las superficies de rodamiento constituyen uno de los mayores desafíos en las sustituciones protéticas, ya que cada día se someten a mayores demandas por un cada vez mayor número de pacientes jóvenes y adultos mayores con expectativas de vida prolongadas y notable actividad. El objetivo de esta revisión es analizar los pros y contras en cuanto a los avances de los componentes de rodamiento de las superficies articulares de las artroplastias totales de cadera contemporáneas. También se discutirán las estrategias que se han seguido a lo largo del tiempo, sus problemas, resultados y el papel que desempeña el cirujano en la prescripción del par tribológico que mejor se adapte a las necesidades de cada paciente. Al final se hacen recomendaciones prácticas para prescripción y manejo de los pares articulares contemporáneos en artroplastia total de cadera.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[artroplastia]]></kwd>
<kwd lng="es"><![CDATA[cadera]]></kwd>
<kwd lng="es"><![CDATA[prótesis]]></kwd>
<kwd lng="es"><![CDATA[utilidad]]></kwd>
<kwd lng="en"><![CDATA[arthroplasty]]></kwd>
<kwd lng="en"><![CDATA[hip]]></kwd>
<kwd lng="en"><![CDATA[prosthesis]]></kwd>
<kwd lng="en"><![CDATA[utility]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Art&iacute;culo de actualizaci&oacute;n</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Tribolog&iacute;a moderna en artroplast&iacute;a total de cadera: pros y contras</b></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="3"><b>Modern tribology in total hip arthroplasty: pros and cons</b></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>G&oacute;mez-Garc&iacute;a F&#42;</b>    <br>    <br>Hospital &Aacute;ngeles Mocel.</font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&#42; Acad&eacute;mico Titular de la Academia Mexicana de Cirug&iacute;a,     <br>Profesor Titular de la Residencia de Ortopedia, Universidad La Salle;     <br>Hospital &Aacute;ngeles Mocel, Coordinador de Cadera en la Cl&iacute;nica de Osteoartritis del Hospital &Aacute;ngeles Pedregal,     <br>Editor en Jefe de Acta Ortop&eacute;dica Mexicana.</font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Direcci&oacute;n para correspondencia:</b>    <br>Acad. Dr. Felipe G&oacute;mez Garc&iacute;a    <br>Gob. Ignacio Esteva 107-03,    <br>Col. San Miguel Chapultepec, CP 11850,    <br>Del. Miguel Hidalgo, M&eacute;xico, DF.    ]]></body>
<body><![CDATA[<br>E-mail: <a href="mailto:sla@prodigy.net.mx" target="_blank">sla@prodigy.net.mx</a></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>RESUMEN.</b> Los productos de desgaste y las reacciones adversas que se generan en las superficies de rodamiento constituyen uno de los mayores desaf&iacute;os en las sustituciones prot&eacute;ticas, ya que cada d&iacute;a se someten a mayores demandas por un cada vez mayor n&uacute;mero de pacientes j&oacute;venes y adultos mayores con expectativas de vida prolongadas y notable actividad. El objetivo de esta revisi&oacute;n es analizar los pros y contras en cuanto a los avances de los componentes de rodamiento de las superficies articulares de las artroplastias totales de cadera contempor&aacute;neas. Tambi&eacute;n se discutir&aacute;n las estrategias que se han seguido a lo largo del tiempo, sus problemas, resultados y el papel que desempe&ntilde;a el cirujano en la prescripci&oacute;n del par tribol&oacute;gico que mejor se adapte a las necesidades de cada paciente. Al final se hacen recomendaciones pr&aacute;cticas para prescripci&oacute;n y manejo de los pares articulares contempor&aacute;neos en artroplastia total de cadera.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> artroplastia, cadera, pr&oacute;tesis, utilidad.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>ABSTRACT.</b> The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Key words:</b> arthroplasty, hip, prosthesis, utility.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">La meta principal de un implante es lograr la m&aacute;xima longevidad posible y la <b>estabilidad</b> es el punto cardinal para lograrlo. La estabilidad puede definirse como la serie de eventos que deben ocurrir entre el implante y el hueso para lograr una respuesta biol&oacute;gica equilibrada que permita la presencia de un cuerpo extra&ntilde;o potencialmente generador de efectos indeseables, que est&aacute; sujeto a grandes esfuerzos y debe permanecer por largos per&iacute;odos <i>in situ</i> sin que cause un detrimento significativo de las propiedades biol&oacute;gicas y mec&aacute;nicas del receptor.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Hay dos tipos de estabilidad claramente definidos por el tiempo y por los eventos que tienen que acontecer para obtenerla. Una es la estabilidad primaria o mec&aacute;nica, que se logra en el momento mismo de la operaci&oacute;n y se alcanza por el dise&ntilde;o del implante, los materiales con que se fabrica, los m&eacute;todos alternos de fijaci&oacute;n y la t&eacute;cnica quir&uacute;rgica. La estabilidad secundaria o biol&oacute;gica se logra con el paso del tiempo a trav&eacute;s de adecuados fen&oacute;menos biol&oacute;gicos de remodelamiento &oacute;seo, preservaci&oacute;n de la salud general y &oacute;sea y de ciertas contingencias que pueden estar relacionadas con los materiales implantados. La estabilidad biol&oacute;gica es la responsable del buen funcionamiento a largo plazo de la pr&oacute;tesis y es en este tipo de estabilidad donde ejerce mayor influencia la tribolog&iacute;a (ciencia que estudia la fricci&oacute;n, el desgaste y la lubricaci&oacute;n que tienen lugar durante el contacto entre superficies s&oacute;lidas en movimiento) entre los pares de rodamiento endoprot&eacute;ticos.</font></p>     <p align="justify"><font face="verdana" size="2">La modificaci&oacute;n a los dise&ntilde;os prot&eacute;ticos y a los materiales con los cuales se fabrican ha sido la estrategia preferida por autores y dise&ntilde;adores para obtener mejores resultados de estabilidad. Con este motivo, han aparecido en el mercado una multitud de formas, tama&ntilde;os de pr&oacute;tesis y superficies tribol&oacute;gicas hechas con diferentes materiales; cada una de ellas con una filosof&iacute;a propia y justificaciones racionales para su utilizaci&oacute;n. Esta efervescencia en investigaci&oacute;n, ideas, conceptos y teor&iacute;as ha tra&iacute;do como consecuencia un gran debate en este campo y, entre otras cosas, un cierto grado de confusi&oacute;n entre los cirujanos ortopedistas acerca de cu&aacute;les son los implantes que tentativamente ofrecen mejores ventajas para sus pacientes. La tribolog&iacute;a forma parte activa en lo anterior, por lo que es conveniente que estemos bien informados de los avances y limitaciones en este campo.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Objetivo</b></font></p>     <p align="justify"><font face="verdana" size="2">Revisar y analizar los pros y los contras de los avances en el dise&ntilde;o de componentes de rodamiento de las superficies articulares de las artroplast&iacute;as totales de cadera contempor&aacute;neas, ya que esto representa hoy por hoy el desaf&iacute;o m&aacute;s importante en las sustituciones prot&eacute;ticas, pues cada d&iacute;a se les obliga a someterse a mayores demandas por un cada vez mayor n&uacute;mero de pacientes j&oacute;venes y adultos mayores con expectativas de vida prolongadas y notable actividad. Tambi&eacute;n se discutir&aacute;n las estrategias que se han seguido a lo largo del tiempo, sus resultados, problemas y el papel que desempe&ntilde;a el cirujano en la prescripci&oacute;n del par tribol&oacute;gico que mejor se adapte a las necesidades de cada paciente.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Polietileno</b></font></p>     <p align="justify"><font face="verdana" size="2">Las resinas de polietileno son simplemente una repetici&oacute;n en cadena de las mol&eacute;culas de mon&oacute;mero de etileno. Las modalidades de baja densidad, alta densidad y ultra alto peso molecular se refieren a su peso molecular, a la longitud de sus cadenas y a la disposici&oacute;n de las mismas. Los pol&iacute;meros tienen regiones cristalinas y amorfas que pueden sufrir afectaciones en sus propiedades fisicoqu&iacute;micas dependiendo del porcentaje y la disposici&oacute;n que guarden entre s&iacute; las regiones que los componen (<a href="#a10f1" target="_self">Figura 1</a>).</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f1"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f1.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">En general, los pol&iacute;meros con mayores porcentajes de regiones cristalinas tienen mejores m&oacute;dulos el&aacute;sticos y muestran una mayor resistencia a la propagaci&oacute;n de microfracturas; sin embargo, pueden ser m&aacute;s susceptibles a los efectos de la oxidaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">En la d&eacute;cada de 1959, comenz&oacute; la fabricaci&oacute;n comercial de resina de polietileno de ultra alto peso molecular (UHMWPE) y ha tenido avances y mejoras significativas con el paso del tiempo. La <a href="../img/revistas/aom/v28n5/a10t1.jpg" target="_blank">tabla 1</a> resume su evoluci&oacute;n hist&oacute;rica.</font></p>     <p align="justify"><font face="verdana" size="2">Aunque hay diversas empresas que fabrican polietilenos de calidad m&eacute;dica, TICONA es actualmente el principal fabricante de resina de UHMWPE de grado m&eacute;dico, con plantas en Estados Unidos de Norteam&eacute;rica y Alemania. Todas las resinas de TICONA tienen la designaci&oacute;n "GUR", seguida por un indicador num&eacute;rico. Las resinas de grado m&eacute;dico se denominan GUR 1020, 1120, 1050 y 1150. El primero de los cuatro n&uacute;meros ("1") indica que el pol&iacute;mero es designado para el implante ortop&eacute;dico. El segundo d&iacute;gito se&ntilde;ala la presencia ("1") o ausencia ("0") de estearato de calcio, compuesto a&ntilde;adido anteriormente para lubricar e inhibir la corrosi&oacute;n en las plantas fabricantes de UHMWPE y para disminuir el color amarillento de los implantes. El tercer n&uacute;mero indica el peso molecular ("2" si va de dos a cuatro millones y "5" si es mayor a cuatro millones). El cuarto d&iacute;gito es un c&oacute;digo corporativo interno que se reserva para futuras nuevas resinas o modificaciones a las mismas. Con el abandono general de estearato de calcio en 1985, los materiales m&aacute;s populares son GUR 1020 y GUR 1050.</font></p>     <p align="justify"><font face="verdana" size="2">Polietilenos con elevado entrecruzamiento de enlaces</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Es bien conocido que las part&iacute;culas de desgaste producidas por los polietilenos de alta o ultra alta densidad son las que limitan la duraci&oacute;n de los implantes, ya que generan una respuesta inflamatoria seguida de osteolisis periprot&eacute;tica y aflojamiento subsecuente de los implantes. La respuesta de la industria a este problema ha sido el desarrollo de polietilenos con elevado entrecruzamiento de enlaces, pues se ha demostrado que la resistencia al desgaste se mejora significativamente con el alto entrecruzamiento de sus cadenas.</font></p>     <p align="justify"><font face="verdana" size="2">Este elevado entrecruzamiento se obtiene mediante la creaci&oacute;n de enlaces covalentes que interconectan los radicales libres de los pol&iacute;meros originales. El proceso consiste esencialmente en generar una estructura que contenga fibras orientadas en m&uacute;ltiples direcciones, que es diferente a la orientaci&oacute;n fibrilar que portan los materiales tradicionales, donde las fibras se orientan b&aacute;sicamente en el sentido de sus cadenas principales.</font></p>     <p align="justify"><font face="verdana" size="2">La explicaci&oacute;n de c&oacute;mo se aprovecha la propiedad mec&aacute;nica de estructuraci&oacute;n reticulada para disminuir la tasa de desgaste se puede exponer de la siguiente manera. Sabemos que durante las actividades cotidianas, las fuerzas que act&uacute;an sobre las articulaciones son multidireccionales, pero tienen un sentido de movimiento principal. Estos patrones de movilidad pueden ocasionar la aparici&oacute;n de deformaciones pl&aacute;sticas en ese sentido de movilidad. En materiales no biol&oacute;gicos, este tipo de deformaci&oacute;n da origen a la aparici&oacute;n de part&iacute;culas de desgaste. Al poseer los polietilenos altamente cruzados una estructura reticulada con mol&eacute;culas orientadas en varios sentidos, se produce una mayor cohesi&oacute;n de sus estructuras, haci&eacute;ndolas m&aacute;s resistentes a los efectos de movilidad multidireccional. Si, adem&aacute;s, agregamos a lo anterior que estos polietilenos tienen una menor cantidad de radicales libres que puedan reaccionar con el ox&iacute;geno, se logra una menor tasa de oxidaci&oacute;n. La mayor cohesi&oacute;n estructural y la menor oxidaci&oacute;n limitan el desgaste acelerado. Las tasas de desgaste comprobadas en ensayos cl&iacute;nicos preliminares y en pruebas de laboratorio con este polietileno llegan a ser de niveles comparables a las obtenidas con superficies duras como la cer&aacute;mica y el metal.</font></p>     <p align="justify"><font face="verdana" size="2">Como se ver&aacute; m&aacute;s adelante, los polietilenos con enlaces altamente cruzados se fabrican con diversas tecnolog&iacute;as. La m&aacute;s utilizada es la aplicaci&oacute;n de radiaciones ionizantes electromagn&eacute;ticas tipo gamma o con haces de electrones a dosis de entre 5 y 10 Mrads, ya sea que se apliquen en fr&iacute;o o a temperaturas elevadas, en ambientes de aire o en atm&oacute;sferas de nitr&oacute;geno. No obstante lo anterior, debe mencionarse que existe un l&iacute;mite de dosis de radiaci&oacute;n; actualmente sabemos que cuando se aplican dosis superiores a 10 Mrads se logra un mayor entrecruzamiento de enlaces; sin embargo, a pesar de que el alto entrecruzamiento mejora la resistencia al desgaste, tambi&eacute;n reduce algunas de sus propiedades mec&aacute;nicas, haci&eacute;ndolo m&aacute;s fr&aacute;gil, menos duro y con menor resistencia a la tensi&oacute;n y al flujo fr&iacute;o. Lo anterior se traduce en una disminuci&oacute;n de su m&oacute;dulo de elasticidad, dureza y capacidad de frenar la propagaci&oacute;n de microfracturas est&aacute;ticas y/o c&iacute;clicas. Estas alteraciones pueden contribuir a una falla <i>in vivo</i> del dispositivo, tal como la rotura por fatiga en regiones sujetas a gran tensi&oacute;n (por ejemplo, en el mecanismo de bloqueo del inserto contra la base met&aacute;lica) o a traumas continuos (<a href="#a10f2" target="_self">Figura 2</a>).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f2"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f2.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Tambi&eacute;n debe mencionarse que existe otra forma de lograr altos entrecruzamientos, que es la utilizaci&oacute;n de m&eacute;todos qu&iacute;micos mediante la adici&oacute;n de per&oacute;xidos o silanes. El uso de per&oacute;xidos org&aacute;nicos puede lograr entrecruzamientos sustanciales en el polietileno, pero no ha sido aprobado por los organismos reguladores internacionales para su utilizaci&oacute;n en implantes ortop&eacute;dicos. En general, estos m&eacute;todos qu&iacute;micos se utilizan en diversos campos industriales, pero se encuentran en desuso para la elaboraci&oacute;n de implantes ortop&eacute;dicos.</font></p>     <p align="justify"><font face="verdana" size="2">Para limitar los efectos indeseables, se han desarrollado mejoras tecnol&oacute;gicas en la fabricaci&oacute;n de los polietilenos. Por su importancia, destacan el tipo de resina de polietileno utilizada, el grado de densidad, el proceso de manufactura de las barras o placas para maquinar el implante, los m&eacute;todos de entrecruzamiento de enlaces que se emplean -en los actuales polietilenos, el momento en que se adicionan agentes antioxidantes- y los diferentes m&eacute;todos de esterilizaci&oacute;n y empaque (<a href="#a10f3" target="_self">Figura 3</a>).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f3"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f3.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Adem&aacute;s de las caracter&iacute;sticas con las que se fabrica la resina, se han encontrado otras variables que tambi&eacute;n influyen en el comportamiento de los polietilenos, como la degradaci&oacute;n <i>in vivo</i> secundaria a oxidaci&oacute;n, el tiempo de almacenamiento del implante ya empaquetado antes de su uso, el flujo fr&iacute;o y el desgaste ocasionado por un tercer cuerpo. Para la prescripci&oacute;n de implantes de polietileno, se debe tener muy en cuenta que los procesos de fabricaci&oacute;n son similares, pero hay ciertos matices que los diferencian y es en estas diferencias donde se expresan los efectos de comportamiento cl&iacute;nico de cada uno de ellos (<a href="#a10f4" target="_self">Figura 4</a>).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    ]]></body>
<body><![CDATA[<p><a name="a10f4"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f4.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Como se puede observar en la <a href="#a10f4" target="_self">figura 4</a>, se tienen que efectuar dos pasos b&aacute;sicos obligatorios para producir los polietilenos con elevado entrecruzamiento. El primer paso es irradiarlo; sin embargo, un serio problema es que con ello se causa una separaci&oacute;n entre las cadenas de polietileno, lo que resulta en la creaci&oacute;n de radicales libres residuales (peroxi). Estos radicales libres pueden seguir varias rutas: a) reaccionar con otros compuestos qu&iacute;micos, principalmente con el ox&iacute;geno; b) unirse otra vez con sus cadenas originales y c) formar entrecruzamientos con otras cadenas polim&eacute;ricas. Si no ocurre ni "a" ni "b", los radicales permanecen libres y tienden a ubicarse en las zonas cristalinas del polietileno.</font></p>     <p align="justify"><font face="verdana" size="2">Como es muy importante disminuir los radicales libres postradiaci&oacute;n, se tiene que seguir un segundo paso, que es estabilizarlo. Este efecto se logra calentando al polietileno, ya que al hacerlo, el material pierde su conformaci&oacute;n (temporal o definitivamente) en las diversas zonas que integran su estructura qu&iacute;mica. En este momento, los radicales libres pueden entrecruzarse o permanecer como tales. Por lo anterior, las diferentes compa&ntilde;&iacute;as han desarrollado protocolos de fabricaci&oacute;n para disminuir la cantidad de radicales libres residuales en estos polietilenos. Para el calentamiento se han utilizado temperaturas por debajo del punto de derretimiento (&plusmn; 130 <sup>o</sup>C) (<i>annealing</i>) y por encima del mismo (<i>melting</i>). Calentar el material por debajo de la temperatura de derretimiento produce cambios temporales, mientras que al derretirlo por arriba de su temperatura de fusi&oacute;n, los cambios son irreversibles.</font></p>     <p align="justify"><font face="verdana" size="2">Otra forma de disminuir la oxidaci&oacute;n es adicionar agentes antioxidantes como el tocoferol. Este punto se tratar&aacute; m&aacute;s adelante.</font></p>     <p align="justify"><font face="verdana" size="2">Es relevante hacer notar que los procesos antes mencionados son diferentes entre los productos comercialmente disponibles (<a href="../img/revistas/aom/v28n5/a10t2.jpg" target="_blank">Tabla 2</a>)<i>, </i>por lo que cada producto es &uacute;nico y se requiere que cada uno de ellos sea estudiado y evaluado individualmente. Ha quedado al albedr&iacute;o de las casas fabricantes cu&aacute;l es la metodolog&iacute;a elegida para incorporarla a sus productos y marcas comerciales, pero a los cirujanos nos corresponde el seguimiento de sus resultados a largo plazo para la adecuada prescripci&oacute;n de los mismos.</font></p>     <p align="justify"><font face="verdana" size="2">La tasa de desgaste como elemento de evaluaci&oacute;n de la calidad de los polietilenos</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Aunque existen diversas variables que determinan la reactividad biol&oacute;gica de los productos de desgaste -como el tama&ntilde;o de las part&iacute;culas y su naturaleza fisicoqu&iacute;mica-, la tasa de generaci&oacute;n de los productos de desgaste es el principal problema; por lo tanto, este par&aacute;metro ha sido el m&aacute;s utilizado para medir su calidad.</font></p>     <p align="justify"><font face="verdana" size="2">No obstante que existen dificultades para medir el desgaste del polietileno <i>in vivo</i> y es dif&iacute;cil calcular o predecir la tasa anual de desgaste debido a la presencia de una enorme diversidad de factores intr&iacute;nsecos y extr&iacute;nsecos, se ha estimado que en polietilenos de ultra alto peso molecular convencionales (sin enlaces altamente cruzados), el desgaste puede ser de entre 0.008 y 0.24 mm/a&ntilde;o. Estas tasas de desgaste fueron comprobadas, entre otros, por Saikko y colaboradores (<i>Acta Orthop Scand. </i>1993), quienes compararon el desgaste <i>in vitro</i> de cabezas femorales modulares de cer&aacute;mica al&uacute;mina versus un polietileno convencional utilizando cinco sistemas prot&eacute;ticos con cabezas de diferentes metales (acero inoxidable con M&uuml;ller y Charnley-Elite, Mallory Head con<i> ion-implanted </i>Ti-6Al-4V y Co-Cr-Mo con Lubinus y PCA) sometidos a una marcha simulada de tres millones de ciclos. El menor promedio de desgaste fue en polietileno contra cer&aacute;mica (0-0.008 mm/a&ntilde;o), mientras que el mayor desgaste fue ocasionado en metal sobre polietileno (0.005-0.24 mm/a&ntilde;o). El comparativo de las tribolog&iacute;as met&aacute;licas entre s&iacute; mostr&oacute; que la cabezas de acero inoxidable ocasionaron las mayores tasas de desgaste, seguidas de las cabezas de Ti-6Al-4V. La menor tasa fue con cer&aacute;micas.</font></p>     <p align="justify"><font face="verdana" size="2">Con el empleo de estos novedosos procesos para la fabricaci&oacute;n de polietilenos, se ha podido demostrar una disminuci&oacute;n dram&aacute;tica en las tasas de desgaste cuando se compara el polietileno con elevado entrecruzamiento de enlaces contra los polietilenos est&aacute;ndar de ultra alto peso molecular fabricados con diversas tecnolog&iacute;as.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Esterilizaci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">Para esterilizar a los componentes articulares de polietileno, se emplean principalmente dos m&eacute;todos: 1) tratamiento de superficie o 2) aplicaci&oacute;n de radiaciones ionizantes. Estos m&eacute;todos tienen efectos espec&iacute;ficos <i>in vivo</i> e <i>in vitro</i> en el desempe&ntilde;o del material.</font></p>     <p align="justify"><font face="verdana" size="2">Los m&eacute;todos de superficie m&aacute;s frecuentemente utilizados para esterilizar al polietileno son 1) el uso de &oacute;xido de etileno (OEt) y 2) el gas plasma. Aunque el OEt es muy t&oacute;xico, es bien tolerado por el polietileno, ya que no reacciona qu&iacute;micamente con este material. La esterilizaci&oacute;n con gas plasma se efect&uacute;a a baja temperatura y requiere menor tiempo que el que se emplea con el OEt. Esta tecnolog&iacute;a es m&aacute;s reciente que la del Oet, pero su utilizaci&oacute;n es a&uacute;n limitada.</font></p>     <p align="justify"><font face="verdana" size="2">Ya se ha mencionado que un serio problema es que la radiaci&oacute;n causa una separaci&oacute;n entre las cadenas de polietileno que ocasiona la creaci&oacute;n de radicales libres residuales que pueden combinarse con el ox&iacute;geno durante su almacenamiento y aun despu&eacute;s de su implantaci&oacute;n. La oxidaci&oacute;n, la creaci&oacute;n de enlaces cruzados y el n&uacute;mero de enlaces cruzados son dependientes de la dosis de radiaci&oacute;n suministrada y de la atm&oacute;sfera donde la radiaci&oacute;n toma lugar. Estos efectos ocasionan reacciones adversas en las propiedades mec&aacute;nicas del polietileno.</font></p>     <p align="justify"><font face="verdana" size="2">Para un mejor entendimiento de los efectos que ocasiona la esterilizaci&oacute;n sobre el pron&oacute;stico de desgaste, har&eacute; referencia a una serie de estudios hechos por McKellop y colaboradores (<i>J Bone Joint Surg Am. </i>2000 y <i>J Orthop Res.</i> 1999), quienes en dos estudios examinaron los efectos sobre el desgaste usando diferentes m&eacute;todos de esterilizaci&oacute;n agregando o no estearato de calcio. Antes de iniciar las pruebas, todos los espec&iacute;menes recibieron una dosis promedio de 2.7 Mrad y en ambas pruebas se emplearon dos diferentes ciclos de marcha simulada. En el primer estudio, el polietileno se someti&oacute; al proceso de envejecimiento t&eacute;rmico. En esta prueba, se revelan tasas de desgaste casi id&eacute;nticas para copas acetabulares con pesos moleculares distintos; ocurre lo mismo en las copas con pesos moleculares del mismo rango con o sin un agregado de estearato de calcio. En el segundo estudio, el polietileno se envejeci&oacute; aceleradamente usando temperaturas de 80 <sup>o</sup>C por 14 d&iacute;as. En este estudio, se pudo observar que las copas que fueron esterilizadas con radiaci&oacute;n gamma en aire muestran tasas m&aacute;s bajas de desgaste que las esterilizadas con &oacute;xido de etileno, presumiblemente debido al entrecruzamiento de enlaces inducidos por la irradiaci&oacute;n. Otra observaci&oacute;n fue que las copas que se irradiaron mientras permanec&iacute;an empacadas en un vac&iacute;o parcial (para minimizar la presencia de ox&iacute;geno) inicialmente mostraron menores tasas de desgaste que las irradiadas en el aire, pero el desgaste fue similar cuando se penetr&oacute; la capa m&aacute;s superficial oxidada y se alcanz&oacute; la zona subyacente m&aacute;s entrelazada.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Despu&eacute;s del envejecimiento artificial para acelerar la degradaci&oacute;n oxidativa de los materiales, las tasas de desgaste son marcadamente diferentes. Los an&aacute;lisis realizados despu&eacute;s de desgaste indican que las copas radiadas (es decir, las altamente cruzadas) exhibieron una proporci&oacute;n menor de productos de desgaste. El examen microsc&oacute;pico mostr&oacute; una longitud m&aacute;s corta de las fibrilaciones y una mayor cristalinidad. Fue evidente que la radiaci&oacute;n gamma en un ambiente pobre en ox&iacute;geno reduce el nivel de oxidaci&oacute;n y aumenta el nivel de entrecruzamiento en la regi&oacute;n superficial de las copas.</font></p>     <p align="justify"><font face="verdana" size="2">Los investigadores concluyeron que antes del envejecimiento del pol&iacute;mero, los efectos de la radiaci&oacute;n para esterilizarlo (incluso en un entorno de ox&iacute;geno) proporcionaron mejoras en las tasas de desgaste en comparaci&oacute;n con aquellos componentes que nunca se esterilizaron o que fueron esterilizados con &oacute;xido de etileno. Sin embargo, la oxidaci&oacute;n y la fragilidad resultante en el polietileno hacen que se pierdan las ventajas de la radiaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">Por lo que se ve, la aplicaci&oacute;n de estas tecnolog&iacute;as para disminuir las tasas de desgaste y esterilizaci&oacute;n pueden tener como consecuencia la disminuci&oacute;n de las propiedades f&iacute;sicas y mec&aacute;nicas. Las propiedades que potencialmente pueden ser alteradas son las diferencias en la concentraci&oacute;n de radicales libres, en oxidaci&oacute;n, cristalinidad y resistencia tensional.</font></p>     <p align="justify"><font face="verdana" size="2">Efectos de los diversos materiales en cabezas </font></p>     <p align="justify"><font face="verdana" size="2">femorales sobre los polietilenos</font></p>     <p align="justify"><font face="verdana" size="2">Se ha demostrado en estudios <i>in vitro</i> e <i>in vivo</i> que el polietileno con gran cantidad de enlaces cruzados es superior al polietileno convencional en cuanto a sus propiedades de resistencia al desgaste y generaci&oacute;n de part&iacute;culas y que la combinaci&oacute;n con superficies cer&aacute;micas (como el &oacute;xido de aluminio o la circona ceramizada) puede mejorar sus caracter&iacute;sticas de desgaste, ya que las cer&aacute;micas son m&aacute;s hidr&oacute;filas que cualquier aleaci&oacute;n met&aacute;lica, por lo que mejoran su lubricaci&oacute;n. Tambi&eacute;n es posible obtener superficies con mayor perfeccionamiento en el pulido en la cer&aacute;mica que en los metales, por lo que disminuye el &iacute;ndice de fricci&oacute;n contra el polietileno; por su dureza, son m&aacute;s resistentes al rayado -lo que se traduce en una mayor protecci&oacute;n contra accidentes- y a la presencia de terceros cuerpos.</font></p>     <p align="justify"><font face="verdana" size="2">Polietilenos medicados con vitamina E</font></p>     <p align="justify"><font face="verdana" size="2">La incorporaci&oacute;n m&aacute;s reciente para prevenir el riesgo de oxidaci&oacute;n en los polietilenos altamente cruzados, en especial por el problema que representan los radicales libres residuales despu&eacute;s de irradiaci&oacute;n, es la adici&oacute;n a la resina de vitamina E (alfa tocoferol). Esta alternativa se encuentra a&uacute;n en fase de investigaci&oacute;n; sin embargo, los resultados preliminares en laboratorio y en vivo son altamente esperanzadores. Para incorporar este elemento, se utilizan dosis de entre 0.1 y 0.3% del peso que se mezclan con la resina GUR 1050, que luego es irradiada y calentada. Actualmente, se contin&uacute;an desarrollando tecnolog&iacute;as para incluir en todo el polietileno la presencia de la vitamina E y no s&oacute;lo en la superficie, como se hizo en los polietilenos precursores.</font></p>     <p align="justify"><font face="verdana" size="2">Cuando este material se compara con el polietileno virgen que no contiene vitamina E, se encuentran tasas de oxidaci&oacute;n entre 50 y 100 veces menores entre el UHMWPE medicado y el no tratado, mientras que el porcentaje de cristalinidad no var&iacute;a entre uno y otro. Seg&uacute;n Oral (<i>Biomaterials.</i> 2005), la mejor&iacute;a en la resistencia a la fatiga ha sido hasta de 58%, lo que eliminar&iacute;a la necesidad de tratamientos t&eacute;rmicos para excluir los radicales libres. Sin embargo, no existen a&uacute;n suficientes estudios prospectivos, comparativos, aleatorizados, con tama&ntilde;os de muestra suficientes y con seguimientos mayores a 10 a&ntilde;os, por lo que debemos estar atentos a los resultados de los pacientes en seguimiento a largo plazo.</font></p>     <p align="justify"><font face="verdana" size="2">Respuesta cl&iacute;nica a los polietilenos altamente cruzados</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Es conveniente recordar que el uso cl&iacute;nico de los polietilenos con alto entrecruzamiento se inici&oacute; en 1998 y, por tanto, la experiencia cl&iacute;nica a mediano plazo es limitada. Los estudios disponibles hasta el momento son en su mayor&iacute;a comparaciones, pruebas de materiales <i>in vivo</i> y en laboratorio y seguimientos cortos.</font></p>     <p align="justify"><font face="verdana" size="2">La bibliograf&iacute;a de reportes en fallas del polietileno altamente cruzado es muy escasa y, aparentemente, las tasas de falla son muy bajas si se toma en cuenta el n&uacute;mero de implantaciones contra el n&uacute;mero de fallas. No obstante lo anterior, desde hace tiempo han empezado a aparecer art&iacute;culos en los cuales se observa una disociaci&oacute;n entre los resultados de los estudios en laboratorio y los resultados cl&iacute;nicos cuando se analizan insertos de polietileno altamente entrecruzado que fueron retirados en revisiones por causas distintas a la fatiga de material. En ellos se ha observado p&eacute;rdida del maquinado, as&iacute; como la presencia de defectos que sugieren patrones de desgaste mucho mayores a los reportados en estudios con simuladores de cadera. Tambi&eacute;n debe tenerse en cuenta que las caracter&iacute;sticas fisicoqu&iacute;micas de las part&iacute;culas del desgaste de los polietilenos altamente cruzados son diferentes en tama&ntilde;o, forma y potencialidad reactiva biol&oacute;gica que las observadas en polietilenos convencionales, por lo que este punto constituye un foco de atenci&oacute;n futura. Por las razones anteriores, es conveniente tener cautela a la hora de abrazar estas innovaciones. Afortunadamente, ha habido avances significativos en el desarrollo de este material y s&oacute;lo es cuesti&oacute;n de tiempo para que se culmine el seguimiento de numerosos estudios que est&aacute;n en curso tendientes a cumplir el prop&oacute;sito de evaluar realmente el lugar que debe ocupar esta nueva herramienta terap&eacute;utica en la artroplast&iacute;a total de cadera. Debemos recordar que los polietilenos con elevado entrecruzamiento de enlaces son diferentes entre s&iacute;.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Metal-metal</b></font></p>     <p align="justify"><font face="verdana" size="2">En los &uacute;ltimos a&ntilde;os, ha habido un renacimiento de la tribolog&iacute;a metal-metal. Los investigadores en el comportamiento de los metales y sus efectos en seres vivos nos dicen que todos los metales que contactan con sistemas biol&oacute;gicos sufren de un proceso electroqu&iacute;mico llamado corrosi&oacute;n, que tiene como efecto generar iones met&aacute;licos que al interrelacionarse con prote&iacute;nas end&oacute;genas, pueden activar el sistema inmune y generar respuestas indeseables. Hoy sabemos que la tribolog&iacute;a metal-metal genera iones y part&iacute;culas que est&aacute;n directamente relacionados con el tipo de aleaci&oacute;n met&aacute;lica, el dise&ntilde;o de los componentes y el posicionamiento de los implantes.</font></p>     <p align="justify"><font face="verdana" size="2">El Dr. Hans Georg Willert public&oacute; en el 2005 un art&iacute;culo en el que correlaciona las reacciones de hipersensibilidad con la liberaci&oacute;n de iones en implantes metal-metal que ocasionaron cambios indeseables en los tejidos periprot&eacute;ticos. Este autor acu&ntilde;o el t&eacute;rmino de "ALVAL", que por sus siglas en ingl&eacute;s (<i>aseptic lymphocytic vasculitis and associated lesion</i>) significa una vasculitis as&eacute;ptica ligada a linfocitos asociada a otras lesiones. Las lesiones son abundancia de fibrina, ac&uacute;mulos de c&eacute;lulas macrof&aacute;gicas y de eosin&oacute;filos con focos de necrosis. Actualmente, entendemos el ALVAL como aquellas lesiones representadas por una histolog&iacute;a dominada por linfocitos B y c&eacute;lulas plasm&aacute;ticas que sugieren una respuesta inmune, con un patr&oacute;n histol&oacute;gico parecido, pero no igual, al de una reacci&oacute;n de hipersensibilidad tard&iacute;a grado IV.</font></p>     <p align="justify"><font face="verdana" size="2">Desde la publicaci&oacute;n del art&iacute;culo de Willert, han aparecido una multitud de reportes que asocian la tribolog&iacute;a metal-metal con diversos tipos de reacciones adversas, en especial, la hipersensibilidad mediada por c&eacute;lulas y la formaci&oacute;n de seudotumores s&oacute;lidos o con contenido l&iacute;quido, algunos de ellos con necrosis granulomatosa. Tambi&eacute;n se ha intentado explicar la patog&eacute;nesis de las reacciones al&eacute;rgicas asoci&aacute;ndola a la presencia de ciertas inmunoglobulinas como la HLA DR+ CD8+e, interleucinas como la IL-8 y la IP-10, entre otras substancias.</font></p>     <p align="justify"><font face="verdana" size="2">Llama la atenci&oacute;n que no s&oacute;lo han aparecido alteraciones locales, sino tambi&eacute;n efectos sist&eacute;micos caracterizados por linfopenia de c&eacute;lulas T. Por otra parte, las caracter&iacute;sticas metal&uacute;rgicas (ej. bajo contenido de carbono) y las de dise&ntilde;o (ej. baja tolerancia de los implantes), al igual que el mal posicionamiento (ej. pinzamiento de bordes) han jugado un papel importante en el incremento de iones y part&iacute;culas, con la consecuente aparici&oacute;n de fen&oacute;menos al&eacute;rgicos y otras reacciones adversas. Todas estas alteraciones se manifiestan por dolor disfuncional o aflojamiento prot&eacute;tico que obligan a un recambio. Est&aacute;n bajo observaci&oacute;n los posibles efectos teratog&eacute;nicos y de carcinog&eacute;nesis a largo plazo.</font></p>     <p align="justify"><font face="verdana" size="2">Una situaci&oacute;n que, en cierta forma, confunde es el hecho de que aunque hay suficientes evidencias de la relaci&oacute;n entre iones y part&iacute;culas met&aacute;licas con reacciones adversas, no todas las lesiones derivadas de ello presentan las mismas caracter&iacute;sticas cl&iacute;nico-patol&oacute;gicas ni el mismo patr&oacute;n histol&oacute;gico. La confusi&oacute;n no s&oacute;lo se limita a las descripciones histol&oacute;gicas de las lesiones, sino tambi&eacute;n a su nomenclatura, ya que las reacciones indeseables se describen con distintos nombres: alergia, hipersensibilidad, seudotumores, metalosis, ALVAL y generalizaciones tales como "reacciones adversas a metales".</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En un intento para poner orden, se han presentado propuestas para clasificar y calificar los hallazgos histol&oacute;gicos. Esto se ha hecho mediante un descripci&oacute;n fraccionada de los hallazgos relacionados con la membrana sinovial, el tipo de infiltrado inflamatorio y c&oacute;mo se organizan los tejidos.</font></p>     <p align="justify"><font face="verdana" size="2">No obstante estos avances, a&uacute;n quedan preguntas por responder por pat&oacute;logos, inmun&oacute;logos y cirujanos interesados en el estudio de este campo: &iquest;son diferentes los mecanismos inmunol&oacute;gicos?, &iquest;son distintas fases de un mismo proceso?, &iquest;son reacciones individuales a la misma noxa? y &iquest;qu&eacute; hace falta para uniformar los criterios histol&oacute;gicos?</font></p>     <p align="justify"><font face="verdana" size="2">En fin, esta parte de historia es importante; sin embargo, algo que nos interesa sobremanera a nosotros los cirujanos comunes y corrientes es saber cu&aacute;l es la importancia cl&iacute;nica. Para contestar esta pregunta, primero debemos saber cu&aacute;l es la magnitud del problema. Sabemos que la incidencia de hipersensibilidad a metales en seres humanos en poblaci&oacute;n general puede llegar hasta 15%; en trabajadores metal&uacute;rgicos, a 10% y en pacientes con implantes met&aacute;licos, a la nada despreciable cifra de 5.4%.</font></p>     <p align="justify"><font face="verdana" size="2">En cuanto a la incidencia de ALVAL, es dif&iacute;cil saberlo, en parte por las dificultades de clasificaci&oacute;n de tejidos ya anteriormente mencionadas y por la escasez de pat&oacute;logos bien calificados para identificarla. Sin embargo, en los peores reportes, la incidencia no sobrepasa de 3%.</font></p>     <p align="justify"><font face="verdana" size="2">Con relaci&oacute;n a la incidencia de seudotumores, tenemos el mismo problema. En una serie multic&eacute;ntrica canadiense que incluye 3,232 caderas, se pudo identificar s&oacute;lo un seudotumor y en la serie inglesa del <i>Nuffiel Orthopaedic Centre</i> de 1,419 caderas, se detectaron 22 de estas lesiones. Muy recientemente, se han publicado estudios con pacientes "asintom&aacute;ticos". En uno de ellos, se evaluaron un total de 201 caderas con una media de seguimiento de 61 meses usando para la detecci&oacute;n ultrasonido y resonancia magn&eacute;tica. En estos pacientes "asintom&aacute;ticos", se encontr&oacute; una frecuencia de siete seudotumores (4%). Este estudio sugiere que la presencia de seudotumores en pacientes aparentemente "normales" puede aumentar la cifra de incidencia general de este problema.</font></p>     <p align="justify"><font face="verdana" size="2">Con las evidencias anteriores, podemos decir hasta hoy que son pocos los pacientes con pr&oacute;tesis meta-metal que desarrollan reacciones adversas que obliguen a efectuar un recambio.</font></p>     <p align="justify"><font face="verdana" size="2">Es importante mencionar que <b>no todos los dise&ntilde;os metal-metal son iguales</b>. El registro australiano de artroplast&iacute;as documenta que hay modelos con altas tasas de falla. Menciona que las pr&oacute;tesis de resuperficializaci&oacute;n ASR<sup>&reg;</sup>, Durom<sup>&reg;</sup> y Cormet<sup>&reg;</sup> son las que tienen la mayor incidencia de falla. Recientemente se agreg&oacute; a esta lista la pr&oacute;tesis Bionik<sup>&reg;</sup>. Los implantes Cormet<sup>&reg;</sup> ya fueron retirados del mercado australiano.</font></p>     <p align="justify"><font face="verdana" size="2">En cuanto al diagn&oacute;stico no invasivo, los estudios de mayor utilidad son la radiolog&iacute;a simple, el ultrasonido, la tomograf&iacute;a axial y la resonancia magn&eacute;tica. Debe mencionarse que las pruebas cl&aacute;sicas utilizadas para detectar hipersensibilidad o alergia por otras especialidades m&eacute;dicas (pruebas de sensibilidad de migraci&oacute;n y parches d&eacute;rmicos) no tienen la suficiente sensibilidad ni especificidad, por lo que hay un consenso entre ortopedistas que no deben utilizarse. Los estudios de laboratorio considerados como est&aacute;ndar de oro para el diagn&oacute;stico de hipersensibilidad inducida por metales son los ensayos de proliferaci&oacute;n linfoc&iacute;tica, an&aacute;lisis de algunas citoquinas usando ELISA e inhibici&oacute;n de migraci&oacute;n linfoc&iacute;tica. Otras citoquinas como la IL-8 y la IP 10 a&uacute;n est&aacute;n bajo estudio, pero podr&iacute;an ser de futura utilidad. En fin, estamos a&uacute;n lejos de tener una prueba &uacute;nica confiable para el diagn&oacute;stico de hipersensibilidad a metales en paciente con implantes ortop&eacute;dicos, por lo que tendremos que utilizar diversos recursos para llegar al diagn&oacute;stico, sobre todo en etapas tempranas. Mientras tanto, debemos estar muy atentos con pacientes que se consideren como de alto riesgo, como los portadores de componentes peque&ntilde;os, g&eacute;nero femenino de talla baja, pr&oacute;tesis colocadas en terreno de alteraciones anat&oacute;micas significativas (ej. displasia acetabular), con posicionamiento inadecuado de los implantes y con antecedentes al&eacute;rgicos a metales.</font></p>     <p align="justify"><font face="verdana" size="2">La Agencia Regulatoria de Medicamentos y Cuidados para la Salud del Reino Unido ha emitido una serie de recomendaciones para pacientes que se han sometido a una artroplast&iacute;a con tribolog&iacute;a metal-metal. Como medidas generales recomienda:</font></p>     <p align="justify">    ]]></body>
<body><![CDATA[<blockquote><font face="verdana" size="2">a)	Hacer un seguimiento anual m&iacute;nimo de cinco a&ntilde;os o m&aacute;s frecuentemente si hay s&iacute;ntomas.</font></p>     <p align="justify"><font face="verdana" size="2">b)	Deben medirse los niveles de metales y hacer estudios imagenol&oacute;gicos con resonancia magn&eacute;tica y ultrasonido en pacientes con mal posicionamiento de implantes, cuando son portadores de pr&oacute;tesis de recubrimiento de tama&ntilde;o peque&ntilde;o, en los casos donde hay preocupaciones del paciente y el cirujano acerca del comportamiento del metal-metal y en modelos con elevadas tasas de falla.</font></p>     <p align="justify"><font face="verdana" size="2">c)	Si los niveles de iones met&aacute;licos son elevados, reforzar la vigilancia y, en caso necesario, hacer estudios imagenol&oacute;gicos especiales.</font></p>     <p align="justify"><font face="verdana" size="2">d)	Si estos estudios revelan reacciones en tejidos blandos periprot&eacute;ticos, debe considerase la cirug&iacute;a de revisi&oacute;n. </font></blockquote></p>     <p align="justify"><font face="verdana" size="2">En el 2012, la <i>Federal Drug and Food Administration</i> (FDA) lanz&oacute; un memor&aacute;ndum (<i>Executive Summary memorandum metal-on-metal hip implant systems</i>) para alertar sobre el uso, indicaciones y manejo de pacientes portadores de implantes metal-metal.</font></p>     <p align="justify"><font face="verdana" size="2">Como comentario, mencionaremos que las reacciones adversas a materiales prot&eacute;ticos en implantes metal-metal son poco frecuentes, pero debemos vigilarlas y estar alertas a la evoluci&oacute;n de su perspectiva hist&oacute;rica y al desarrollo de los m&eacute;todos de diagn&oacute;stico temprano para esta entidad, que parece estar dominada por implantes con tribolog&iacute;a de metal-metal.</font></p>     <p align="justify"><font face="verdana" size="2">Modularidad y reacciones adversas</font></p>     <p align="justify"><font face="verdana" size="2">La modularidad entre la cabeza femoral y el cono del v&aacute;stago femoral tiene diversos beneficios, que incluyen, entre otros, la posibilidad de hacer ajustes de lateralizaci&oacute;n de la cadera y longitud de la extremidad, cambiar &uacute;nicamente la cabeza femoral cuando es necesario y disminuir el inventario de implantes en los hospitales.</font></p>     <p align="justify"><font face="verdana" size="2">Sin embargo, desde hace tiempo sabemos que la uni&oacute;n &iacute;ntima de metales diferentes (titanio/cobalto-cromo) puede causar corrosi&oacute;n galv&aacute;nica y, cuando hay dise&ntilde;os defectuosos (en especial en cuanto a tolerancias), puede haber una corrosi&oacute;n por frotamiento (<a href="#a10f5" target="_self">Figura 5</a>). No obstante lo anterior, las mejoras en la fabricaci&oacute;n y dise&ntilde;o de esta parte de las pr&oacute;tesis ha permitido el uso universal de modularidad entre cabeza/v&aacute;stago.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    ]]></body>
<body><![CDATA[<p><a name="a10f5"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f5.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Debido al &eacute;xito de la modularidad, se ha puesto escasa atenci&oacute;n a los problemas que pueden surgir de la misma. Recientemente, se ha identificado que la corrosi&oacute;n generada en esta parte de los sistemas puede presentar alteraciones similares a las de la tribolog&iacute;a metal-metal, como son elevados niveles de metales en suero, dep&oacute;sitos de metales en tejidos blandos periprot&eacute;ticos o reacciones adversas a tejidos blandos.</font></p>     <p align="justify"><font face="verdana" size="2">Un nuevo espacio de atenci&oacute;n es el que se relaciona con las reacciones adversas en la modularidad entre superficies met&aacute;licas, en especial, cuando hay combinaci&oacute;n de materiales distintos. Debemos estar atentos a su evoluci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Cer&aacute;mica-cer&aacute;mica</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Los pares cer&aacute;mica-cer&aacute;mica se han empleado desde los a&ntilde;os setenta y han tenido una evoluci&oacute;n hist&oacute;rica muy interesante donde las mejoras tecnol&oacute;gicas en la mezcla y fabricaci&oacute;n de sus compuestos qu&iacute;micos y procesos termodin&aacute;micos (ej. el sinterizado), el dise&ntilde;o (ej. diferencias entre las curvaturas c&oacute;ncavas y convexas) y la mejor comprensi&oacute;n del funcionamiento de los sistemas "cono Morse" (forma de los conos) han formado parte fundamental en el buen funcionamiento cl&iacute;nico (<a href="#a10f6" target="_self">Figura 6</a>).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f6"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f6.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Entre los pares de fricci&oacute;n actuales, la cer&aacute;mica-cer&aacute;mica posee el menor coeficiente de fricci&oacute;n de todas las tribolog&iacute;as existentes, ya que su peque&ntilde;o tama&ntilde;o de grano le permite tener una muy baja rugosidad en la superficie, su muy elevada dureza ofrece una mayor resistencia al rayado y su alta capacidad hidrof&iacute;lica le permite una excelente lubricaci&oacute;n. Adem&aacute;s de lo anterior, las superficies articulares de cer&aacute;mica se asocian a bajos niveles de osteolisis, entre otras razones, porque las cer&aacute;micas son bioinertes y porque las part&iacute;culas de desecho que producen son de muy peque&ntilde;o tama&ntilde;o. Estas caracter&iacute;sticas hacen que en el ambiente articular se produzcan simples reacciones fibrosas en vez de inflamatorias como las observadas con el polietileno; es decir, las cer&aacute;micas producen una escasa respuesta biol&oacute;gica indeseable.</font></p>     <p align="justify"><font face="verdana" size="2">Las mejoras antes mencionadas y otras caracter&iacute;sticas (<a href="../img/revistas/aom/v28n5/a10t3.jpg" target="_blank">Tabla 3</a>) han ocasionado que los resultados cl&iacute;nicos de las cer&aacute;micas sean cada vez mejores. No obstante las ventajas antes mencionadas, las cer&aacute;micas actuales presentan tres problemas principales, que son la fractura, el ruido al caminar y el despostillado sin ruptura.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Fractura de cer&aacute;micas. </b>Aunque las cer&aacute;micas tienen una mucho mayor resistencia a las fuerzas compresivas que a la tensi&oacute;n y poseen una muy baja ductilidad cuando se exponen a cargas o impactos tensionales, el riesgo de fractura est&aacute; potencialmente presente en esta tribolog&iacute;a (<a href="#a10f7" target="_self">Figura 7</a>). En un estudio de centros europeos con cerca de 30 a&ntilde;os de experiencia en el uso de cer&aacute;mica-cer&aacute;mica, se presentaron 13 fracturas de cer&aacute;mica en 5,500 componentes implantados. La mayor&iacute;a se atribuy&oacute; a un traumatismo aislado y, en los casos donde las fracturas ocurrieron sin trauma, la falla se atribuy&oacute; a deficiencias en la estructura de la cer&aacute;mica o al dise&ntilde;o del componente. Este estudio, que incluye desde la primera a la tercera generaci&oacute;n de cer&aacute;micas, ilustra que a pesar de las mejoras tanto a los materiales como a los dise&ntilde;os, no se elimin&oacute; por completo el riesgo de fractura. Hoy por hoy, se considera que el mayor riesgo de ruptura reside en el mal posicionamiento de los implantes.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f7"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f7.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">En la historia de las cer&aacute;micas, se distinguen dos tipos principales de este material: a) las que tienen como base al&uacute;mina (hidr&oacute;xido de aluminio &#91;Al<sub>2</sub>O<sub>3</sub>&#93;) -que ofrece alta estabilidad fisicoqu&iacute;mica y excelentes caracter&iacute;sticas tribol&oacute;gicas; sin embargo, presenta pobre dureza, por lo que no se utiliza para la fabricaci&oacute;n de formas complejas ni para componentes muy delgados- y b) las hechas a base de circona (di&oacute;xido de circonio &#91;ZiO<sub>2</sub>&#93;) -que es m&aacute;s dura pero menos estable (fuerte variabilidad a la degradaci&oacute;n<i> in vivo</i>) y cuyos resultados cl&iacute;nicos no han sido satisfactorios, ya que presentan fallas tempranas-. Estos resultados han abierto una pol&eacute;mica sobre el futuro de la circona como biomaterial &uacute;nico en la fabricaci&oacute;n de implantes (<a href="#a10f6" target="_self">Figura 6</a>) </font></p>     <p align="justify"><font face="verdana" size="2">Recientemente, se ha obtenido un nuevo material compuesto por una matriz al&uacute;mina con inclusiones de circona (Al<sub>2</sub>O<sub>3</sub> + ZiO<sub>2</sub>) llamado Biolox Delta<sup>&reg;</sup> (CeramTec AG, Plochingen, Alemania), que mejora las caracter&iacute;sticas positivas de ambos materiales (<a href="#a10f8" target="_self">Figura 8</a>).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f8"></a></p>    ]]></body>
<body><![CDATA[<p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f8.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">La composici&oacute;n qu&iacute;mica volum&eacute;trica de la cer&aacute;mica compuesta Biolox Delta<sup>&reg;</sup> se muestra en la <a href="#a10f9" target="_self">figura 9</a>. Aunque es un verdadero alarde de tecnolog&iacute;a, debemos mencionar que esta combinaci&oacute;n se encuentra en discusi&oacute;n por el problema que representa la degradaci&oacute;n de los materiales, en especial de la circona (envejecimiento).</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f9"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f9.jpg"></p>    <p>&nbsp;</p>    ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Recientemente, Hamilton y colaboradores (<i>Clin Orthop Relat Res. </i>2010) publicaron un estudio donde comparan articulaciones de cer&aacute;mica delta sobre cer&aacute;mica delta contra cer&aacute;mica delta sobre polietileno de ultra alta densidad con elevado entrecruzamiento de enlaces. Aunque el seguimiento fue corto (dos a&ntilde;os m&iacute;nimo, con promedio de 31.2 meses y rango de 21 a 49 meses), de los 177 pacientes a los que aplicaron s&oacute;lo cer&aacute;micas, cuatro fueron revisados; en dos se detectaron eventos relacionados con el inserto acetabular (en uno se present&oacute; un despostillamiento que amerit&oacute; revisi&oacute;n y en otro se detectaron fragmentos de cer&aacute;mica durante el seguimiento radiogr&aacute;fico, pero no ha requerido revisi&oacute;n). No hubo ruidos en ning&uacute;n caso. Debe mencionarse que se revisaron tres pacientes con cer&aacute;mica delta versus polietileno por causas ajenas a la cer&aacute;mica.</font></p>     <p align="justify"><font face="verdana" size="2">Ruidos articulares. En un estudio hecho <i>in vivo</i> por Glaser y colaboradores (<i>J Bone Joint Surg Am.</i> 2008) en pacientes portadores de pr&oacute;tesis totales de cadera con diferentes tribolog&iacute;as, se pudo demostrar que todos los pares articulares son capaces de producir ruidos (<a href="../img/revistas/aom/v28n5/a10t4.jpg" target="_blank">Tabla 4</a>).</font></p>     <p align="justify"><font face="verdana" size="2">En cuanto a sus caracter&iacute;sticas, los ruidos pueden ser percibidos de diversas maneras y describirse como chasquidos, golpeteos (sonoros o sordos), aldabazos, rasquidos, rechinidos, crujidos, crepitaciones y chirridos y pueden presentarse durante todo el ciclo de la marcha, en alguna fase de la misma o durante ciertas actividades espec&iacute;ficas. Los ruidos pueden o no ser audibles y son comunes despu&eacute;s de un reemplazo articular total convencional, con una incidencia global que alcanza hasta 96%; sin embargo, no todos pueden o&iacute;rse o "sentirse" por el paciente, pero en las superficies de "duro contra duro" pueden llegar a ser audibles incluso a distancia, lo que en los &uacute;ltimos a&ntilde;os se ha reconocido como una complicaci&oacute;n de este tipo de pares articulares.</font></p>     <p align="justify"><font face="verdana" size="2">En cuanto a su incidencia, se desconoce cu&aacute;l es la real en ruidos de alta frecuencia (audibles), toda vez que diversos autores reportan una presencia cl&iacute;nica muy variada que va de menos de 1 hasta 20%.</font></p>     <p align="justify"><font face="verdana" size="2">La etiolog&iacute;a de los ruidos es multifactorial y se encuentran implicados factores relacionados con el paciente (complexi&oacute;n, peso, estilos de vida, etc&eacute;tera), con la pr&oacute;tesis (tipo de implante, defectos en la fabricaci&oacute;n, mala posici&oacute;n y combinaciones de diferentes dise&ntilde;os), con el cirujano (mal posicionamiento) y con la superficie de rodamiento (microseparaci&oacute;n, deficiencias en la lubricaci&oacute;n, pinzamientos y terceros cuerpos intrarticulares).</font></p>     <p align="justify"><font face="verdana" size="2"><b>Despostillamientos. </b>Aunque es un accidente reportado en la literatura, es un evento sumamente raro que est&aacute; relacionado, principalmente, con dos factores. El primero es una deficiente manipulaci&oacute;n transquir&uacute;rgica y el segundo, la colisi&oacute;n entre el cuello femoral y el borde del inserto de cer&aacute;mica. Esto &uacute;ltimo puede evitarse colocando cabezas con el mayor di&aacute;metro posible y prescribiendo dise&ntilde;os que tengan protecci&oacute;n contra colisiones entre los componentes.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Metales ceramizados (Oxinium</b><sup>&reg;</sup><b>)</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La exigencia actual de mejores rendimientos para las artroplast&iacute;as totales de cadera y rodilla est&aacute; impulsando el desarrollo de materiales tribol&oacute;gicos alternativos. En Julio de 1995, Hunter (<i>J ATSM Int.</i> 2005) public&oacute; estudios que introducen al &oacute;xido de circonio (Oxinium<sup>&reg;</sup>-Smith &amp; Nephew, Inc., Memphis, TN) como parte articular de los implantes ortop&eacute;dicos. Este material es una aleaci&oacute;n met&aacute;lica de circonio con una superficie de cer&aacute;mica de circona (circonio y circona no son lo mismo; circonio es un metal y circona una cer&aacute;mica) que ofrece una sobresaliente resistencia al desgaste, pero sin la fragilidad de las cer&aacute;micas, por lo que este material combina lo mejor del metal y de las cer&aacute;micas sin crear el riesgo de las fracturas asociadas a los componentes cer&aacute;micos monol&iacute;ticos.</font></p>     <p align="justify"><font face="verdana" size="2">La oxidaci&oacute;n del circonio a una alta temperatura en presencia de aire transforma la superficie de la aleaci&oacute;n met&aacute;lica Zr-2.5Nb en una cer&aacute;mica estable producto de una aleaci&oacute;n entre circonio, niobio y ox&iacute;geno (circona) y se ha constituido en una esperanzadora alternativa para las aleaciones monol&iacute;ticas de cromocobalto, ya que, comparativamente, se reduce el desgaste del polietileno (<a href="#a10f10" target="_self">Figura 10</a>) y puede atender las necesidades de los pacientes que presentan hipersensibilidad a los metales.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p><a name="a10f10"></a></p>    <p>&nbsp;</p>    <p align="center"><img src="../img/revistas/aom/v28n5/a10f10.jpg"></p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana"></font></p>     <p align="justify"><font face="verdana" size="2">Aunque en el laboratorio el Oxinium<sup>&reg;</sup> sufre 4,900 veces menos desgaste volum&eacute;trico y 640 veces menos huellas de ara&ntilde;azos profundos cuando se le compara con las aleaciones de cromocobalto tradicionales, el sustrato de circonio es relativamente suave (HV = 285) en comparaci&oacute;n con cabezas femorales de cromocobalto (HV= &#126; 420), lo que lo hace muy riesgoso cuando existe un tercer cuerpo o, bien, ocurre una dislocaci&oacute;n donde las cabezas prot&eacute;ticas pueden da&ntilde;arse al entrar en contacto involuntario con los metales de las copas acetabulares.</font></p>     <p align="justify"><font face="verdana" size="2">Kop y colaboradores (Arthroplasty. 2007) analizaron tres casos de retiros de cabezas femorales y demostraron los serios da&ntilde;os que se produjeron durante la luxaci&oacute;n al realizar maniobras cerradas de reducci&oacute;n. Esto tambi&eacute;n lo han podido demostrar otros autores.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En casos de eventos de luxaci&oacute;n con este nuevo material, es recomendable que las maniobras de reducci&oacute;n se ejecuten con mucha precauci&oacute;n para evitar da&ntilde;os significativos de cabeza y, por ello, llevar a un desgaste acelerado de polietileno. En el caso de una reducci&oacute;n cerrada exitosa, se recomienda el seguimiento estrecho del paciente. La reducci&oacute;n abierta con inspecci&oacute;n de cabeza femoral y el intercambio de la misma pueden ser preferibles si se encuentran dificultades durante las maniobras de reducci&oacute;n cerrada o ha ocurrido una luxaci&oacute;n recurrente. Tambi&eacute;n deben vigilarse los pacientes en los que existe el riesgo o se sospecha la presencia de terceros cuerpos intrarticulares, ya sea met&aacute;licos o de cemento.</font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2">  <b>Recomendaciones pr&aacute;cticas para la prescripci&oacute;n y manejo de pares articulares en artroplast&iacute;a total de cadera</b></font></p>     <p align="justify"><font face="verdana" size="2">La necesidad de tener diversas opciones para tratar a los pacientes j&oacute;venes o viejos pero activos, ha hecho que tengamos que utilizar diversos recursos. En esta &uacute;ltima parte del cap&iacute;tulo se hace un ejercicio en el que se sugieren algunas recomendaciones pr&aacute;cticas para la prescripci&oacute;n y manejo de los diferentes pares articulares. En las tablas <a href="../img/revistas/aom/v28n5/a10t5.jpg" target="_blank">5</a> y <a href="../img/revistas/aom/v28n5/a10t6.jpg" target="_blank">6</a> se resumen algunos conceptos que pueden ser &uacute;tiles para facilitar la decisi&oacute;n de prescripci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">Polietilenos</font></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>1) Recomendaciones generales. </b></font></blockquote></p>     <p align="justify"><font face="verdana" size="2">    <blockquote>&bull;	Prefiera la combinaci&oacute;n de cer&aacute;mica-polietileno sobre la de metal-polietileno.</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&bull;	En polietilenos convencionales, es mejor emplear cabezas de 28 mm.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	En polietilenos de ultra alta densidad con enlaces altamente cruzados, es admisible usar cabezas de di&aacute;metro mayor a 28 mm.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Evitar insertos esterilizados con &oacute;xido de etileno (se oxidan).</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Preferir inserto con elevados enlaces cruzados esterilizado con radiaciones gamma, tratado con irradiaci&oacute;n con electrones.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	<b>Recordar que</b> <b>no todos los polietilenos altamente cruzados son iguales</b>.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Tener bajo observaci&oacute;n los nuevos polietilenos, en especial, los medicados con vitamina E.</blockquote></font></p>     <p align="justify"><font face="verdana" size="2">Metal-metal</font></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>1)	Los pacientes considerados como de alto riesgo para desarrollar reacciones adversas son: </b></font></blockquote></p>     <p align="justify">    ]]></body>
<body><![CDATA[<blockquote><font face="verdana" size="2">     <blockquote>&bull;	Los portadores de componentes peque&ntilde;os.</p>     <p align="justify"><font face="verdana" size="2">&bull;	Los de g&eacute;nero femenino y talla baja.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Pacientes con riesgo o insuficiencia renal ya desarrollada.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Pacientes con alteraciones anat&oacute;micas significativas (ej. displasia acetabular).</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Pacientes con antecedentes al&eacute;rgicos a metales.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Pacientes con posicionamiento inadecuado de los implantes. </blockquote> </font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>2) Recomendaciones generales para pacientes que se someter&aacute;n a una artroplast&iacute;a con tribolog&iacute;a metal-metal. </b></font></blockquote></p>     <p align="justify">    ]]></body>
<body><![CDATA[<blockquote><font face="verdana" size="2">     <blockquote>&bull;	Preferir copas con radios de 180<sup>o</sup> con alto contenido de carbono.</p>     <p align="justify"><font face="verdana" size="2">&bull;	Evitar su uso en pacientes que requieran copas menores de 50-52 mm.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Evaluar la conveniencia de usarla en mujeres en edad de embarazo.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	La t&eacute;cnica quir&uacute;rgica deber&aacute; ser muy exacta, especialmente en el adecuado posicionamiento de la copa. La anteversi&oacute;n o apertura lateral excesivas pueden producir pinzamiento de bordes y causar desgaste met&aacute;lico aumentado.</blockquote></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>3) En pacientes con implantes metal-metal ya instalados. </b></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2">     <blockquote>&bull;	Hacer un seguimiento anual m&iacute;nimo de cinco a&ntilde;os o m&aacute;s frecuentemente si hay s&iacute;ntomas.</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&bull;	Deben medirse los niveles de metales y hacer estudios imagenol&oacute;gicos con resonancia magn&eacute;tica y ultrasonido en pacientes con mal posicionamiento de implantes, cuando son portadores de pr&oacute;tesis de recubrimiento de tama&ntilde;o peque&ntilde;o, en los casos donde hay preocupaciones del paciente y el cirujano acerca del comportamiento del metal-metal y en modelos con elevadas tasas de falla.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Si los niveles de iones met&aacute;licos son elevados (&gt; 7 partes por mill&oacute;n), reforzar la vigilancia y, en caso necesario, hacer estudios imagenol&oacute;gicos especiales.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Si estos estudios revelan reacciones en tejidos blandos periprot&eacute;ticos, debe considerarse la cirug&iacute;a de revisi&oacute;n aunque el implante est&eacute; radiol&oacute;gicamente estable. </blockquote> </font></blockquote></p>     <p align="justify"><font face="verdana" size="2">Cer&aacute;mica-cer&aacute;mica</font></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>1) &iquest;Qu&eacute; podemos hacer para disminuir las fracturas? </b></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2">     <blockquote>&bull;	Usar el tama&ntilde;o de componentes lo m&aacute;s grande posible.</p>     <p align="justify"><font face="verdana" size="2">&bull;	Evitar cuellos cortos, en especial, los de 28 mm de di&aacute;metro.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&bull;	Recordar que el cono 12/14 no es universal: &iexcl;hay muchas variaciones!</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Asegurarse de que los componentes cer&aacute;micos y los met&aacute;licos sean compatibles.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Revisar que los conos no est&eacute;n da&ntilde;ados y acoplar los componentes correctamente.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Impactar los componentes con la fuerza necesaria para que no haya expulsiones durante las actividades de marcha.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Asegurarse de la compatibilidad entre la cabeza y el cono femoral. Nunca se deben mezclar componentes de diferentes empresas.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Revisar que los conos no est&eacute;n da&ntilde;ados y que los componentes se acoplen correctamente.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Si el cono met&aacute;lico est&aacute; da&ntilde;ado, utilice cabezas especiales de recambio (Biolox<sup>&reg;</sup> Option). </blockquote> </font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>2) &iquest;Qu&eacute; hacer en caso de que tenga que hacerse una revisi&oacute;n por una fractura de un componente cer&aacute;mico? </b></font></blockquote></p>     <p align="justify">    ]]></body>
<body><![CDATA[<blockquote><font face="verdana" size="2">     <blockquote>&bull;	No use cabeza de metal ni polietileno para sustituir los componentes da&ntilde;ados. Use cer&aacute;mica nuevamente (es muy resistente a los terceros cuerpos residuales de cer&aacute;mica).</p>     <p align="justify"><font face="verdana" size="2">&bull;	Irrigue abundantemente el &aacute;rea para eliminar las part&iacute;culas peque&ntilde;as.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Haga una sinevectom&iacute;a completa.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;Revise meticulosamente los componentes da&ntilde;ados. </blockquote> </font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>3) &iquest;Qu&eacute; hacer cuando ocurre un despostillamiento intraoperatorio de los insertos? </b></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2">     <blockquote>&bull;	Son causadas por falta de familiaridad con la cer&aacute;mica.</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&bull;	Las conexiones c&oacute;nicas tienen que ponerse en su posici&oacute;n final antes de impactarse.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Vigile que no haya colisi&oacute;n entre los implantes en las movilizaciones extremas de la cadera. </blockquote> </font></blockquote></p>     <p align="justify"><font face="verdana" size="2">Oxinium<sup>&reg;</sup></font></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>1) Recomendaciones generales. </b></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2">     <blockquote>&bull;	Haga maniobras de reducci&oacute;n muy cuidadosas para evitar da&ntilde;os a la delgada capa de metal ceramizado.</p>     <p align="justify"><font face="verdana" size="2">&bull;	No prescribirla en pacientes con alto riesgo de luxaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Es una buena alternativa para pacientes j&oacute;venes o viejos activos con antecedentes de alergias a metales y puede cubrir las necesidades de los pacientes que presentan hipersensibilidad a los mismos.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&bull;	Deben vigilarse con mayor frecuencia los pacientes en los que existe el riesgo o se sospecha la presencia de terceros cuerpos intrarticulares, ya sea met&aacute;licos o de cemento. </blockquote> </font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2"> <b>2) &iquest;Qu&eacute; se recomienda en casos de eventos de luxaci&oacute;n? </b></font></blockquote></p>     <p align="justify">    <blockquote><font face="verdana" size="2">     <blockquote>&bull;	Las maniobras de reducci&oacute;n se deben ejecutar con mucha precauci&oacute;n para evitar da&ntilde;os significativos de cabeza.</p>     <p align="justify"><font face="verdana" size="2">&bull;	En el caso de una reducci&oacute;n cerrada exitosa, es recomendable seguir al paciente lo m&aacute;s estrechamente posible.</font></p>     <p align="justify"><font face="verdana" size="2">&bull;	Prefiera una reducci&oacute;n abierta si se encuentran dificultades durante las maniobras de reducci&oacute;n cerrada o ha ocurrido una luxaci&oacute;n recurrente. La finalidad es efectuar una cuidadosa inspecci&oacute;n de cabeza femoral y, si est&aacute; da&ntilde;ada, debe intercambiarse. </blockquote> </font></blockquote></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    <p align="justify"><font face="verdana" size="2"><b>REFERENCIAS</b></font></p>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Para mayor informaci&oacute;n:</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">1.	Harris WH: Wear and periprosthetic osteolysis: the problem. <i>Clin Orthop</i>. 2001; 393: 66-70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147659&pid=S2306-4102201400050001000001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">2.	Santavirta S, Bohler M, Harris WH, et al: Alternative materials to improve total hip replacement tribology. <i>Acta Orthop Scand</i>. 2003; 74(4): 380-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147661&pid=S2306-4102201400050001000002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">3.	G&oacute;mez GF: Estado actual de la pr&oacute;tesis femoral de cadera: SLA una consecuencia l&oacute;gica en artroplastia total de cadera. Ed. McGraw Hill Interamericana; (ISBN 970-10-2548-2) 2000.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147663&pid=S2306-4102201400050001000003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">4.	Atkinson JR, Dowling JM, Cicek RZ: Materials for internal prostheses: the present position and possible future developments. <i>Biomaterials</i>. 1980; 1: 89.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147665&pid=S2306-4102201400050001000004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Polietilenos</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Generalidades</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">5.	Sychterz CJ, Young AM, Orishimo K, Engh CA: The relationship between shelf life and <i>in vivo</i> wear for polyethylene acetabular liners. <i>J Arthroplasty</i>. 2005; 20: 168-73.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147672&pid=S2306-4102201400050001000005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">6.	Kurtz SM: The UHMWPE handbook: ultra-high molecular weight polyethylene in total joint replacement. San Diego, CA: Elsevier Academic Press; 2004: 4, 6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147674&pid=S2306-4102201400050001000006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">7.	Li S, Callaghan JJ: Polyethylene. Chapter 7. In: <i>The adult hip.</i> Philadelphia: Lippincott-Raven; 1998.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147676&pid=S2306-4102201400050001000007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">8.	Heisel C, Silva M, Schmalzried TP: <i>In vivo</i> wear of bilateral total hip replacements: conventional versus crosslinked polyethylene. <i>Arch Orthop Trauma Surg</i>. 2005; 125: 555-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147678&pid=S2306-4102201400050001000008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">9.	Geerdinck CH, Grimm B, Ramakrishnan R, Rondhuis J, Verburg AJ, Tonino AJ: Crosslinked polyethylene compared to conventional polyethylene in total hip replacement: pre-clinical evaluation, <i>in vitro</i> testing and prospective clinical follow-up study. <i>Acta Orthop</i>. 2006; 77: 719-25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147680&pid=S2306-4102201400050001000009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Polietilenos con elevados enlaces cruzados</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">10.	Harris WH, Muratoglu OK: A review of current cross-linked polyethylenes used in total joint arthroplasty. <i>Clin Orthop Relat Res</i>. 2005; (430): 46-52.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147685&pid=S2306-4102201400050001000010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">11. 	Ries MD: Highly cross-linked polyethylene: the debate is over in opposition. <i>J Arthroplasty</i>. 2005; 20(4 Suppl. 2): 59-62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147687&pid=S2306-4102201400050001000011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">12.	Costa L, Jacobson K, Bracco P, et al: Oxidation of orthopaedic UHMWPE. <i>Biomaterials</i>. 2002; 23(7): 1613-24.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147689&pid=S2306-4102201400050001000012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">13.	Costa L, Luda MP, Trossarelli L, et al: Oxidation in orthopaedic UHMWPE sterilised by gamma-radiation and ethylene oxide. <i>Biomaterials</i>. 1998; 19(7-9): 659-68.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147691&pid=S2306-4102201400050001000013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">14.	Costa L, Luda MP, Trossarelli L, et al: <i>In vivo</i> UHMWPE biodegradation of retrieved prosthesis. <i>Biomaterials</i>. 1998; 19(15): 1371-85.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147693&pid=S2306-4102201400050001000014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">15.	Gordon CD, D'Lima D, Clifford W, Colwell CW Jr: Highly cross-linked polyethylene in total hip arthroplasty. <i>J of the Am Acad Orthop Surg</i>. 2006; 4(9): 511-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147695&pid=S2306-4102201400050001000015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">16.	Chiesa RMM, Giordano C, Siccardi F, Cigada A: Influence of heat treatment on structural, mechanical and wear properties of crosslinked UHMWPE. <i>Journal of Applied</i> <i>Biomaterials</i> <i>and Biomechanics</i>. 2004; 2: 20-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147697&pid=S2306-4102201400050001000016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">17.	McKellop H, Shen FW, Lu B, Campbell P, Salovey R: Development of an extremley resistant high molecular weight polyethylene for total hip replacements. <i>J Orthop Res</i>. 1999; 17: 157-67.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147699&pid=S2306-4102201400050001000017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">18.	Grobbelaar CJ, Plessis TAD, Marais F: The radiation improvement of polyethylene prostheses. <i>J Bone Joint Surg Br</i>. 1978; 60: 370.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147701&pid=S2306-4102201400050001000018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">19.	Grobbelaar CJ, Weber FA, Spirakis A, DuPlessis TA, Cappert G, Cakic JN: Clinical experience with gamma irradiation-crosslinked polyethylene-A 14 to 20 year follow-up report. <i>S Afr Bone Joint Surg</i>. 1999; 11: 140.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147703&pid=S2306-4102201400050001000019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">20. 	Oonishi H, Takayama Y, Tsuji E: Improvement of polyethylene by irradiation in artificial joints. <i>Radiat Phys Chem</i>. 1992; 39: 495.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147705&pid=S2306-4102201400050001000020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">21.	Muratoglu OK, Bragdon CR, O'Connor DO, et al: Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). <i>Biomaterials</i>. 1999; 20: 1463.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147707&pid=S2306-4102201400050001000021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">22. 	Harris WH: Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros. <i>Clin Orthop Relat Res</i>. 2004; (429): 63-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147709&pid=S2306-4102201400050001000022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">23.	Charlesby A: Cross-linking of polythene by pile radiation. <i>Proc Roy Soc Lond A</i>. 1952; 215: 187.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147711&pid=S2306-4102201400050001000023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">24.	De Boer J, Pennings A: Crosslinking of ultra-high molecular weight polyethylene in the melt by means of 2.5-dimethyl-2.5-bis (tert-butyldioxy)-3-hexyne: 2. Crystallization behaviour and mechanical properties. <i>Polymer</i>. 1982; 23: 1944.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147713&pid=S2306-4102201400050001000024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">25.	Atkinson JR, Cicek RZ: Silane cross-linked polyethylene for prosthetic applications: Part I. Certain physical and mechanical properties related to the nature of the material. <i>Biomaterials</i>. 1983; 4: 267.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147715&pid=S2306-4102201400050001000025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">26.	Atkinson JR, Cicek RZ: Silane cross-linked polyethylene for prosthetic applications: Part II. Creep and wear behavior and a preliminary molding test. <i>Biomaterials</i>. 1984; 5: 326.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147717&pid=S2306-4102201400050001000026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">27.	Muratoglu OK, Bragdon CR, O'Connor DO, Merri EW, Jasty EM, Harris WH: Electron beam crosslinking of UHMWPE at room temperature, a candidate bearing material for total joint arthroplasty. In: <i>23rd Annual Meeting of the Society for Biomaterials</i>. New Orleans: 1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147719&pid=S2306-4102201400050001000027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">28.	Baker DA, Hastings RS, Pruitt L: Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. <i>J Biomed Mater Res</i>. 1999; 46: 573.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147721&pid=S2306-4102201400050001000028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">29.	DiMaio WG, Lilly WB, Moore WB, Saun KA: Low wear, low oxidation radiation crosslinked UHMWPE. In: <i>44th Annual Meeting Proceedings of Orthopaedic Research Society</i>. New Orleans: 1998; 363.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147723&pid=S2306-4102201400050001000029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">30.	Brach del Prever EM, Crova M, Costa L, et al: Unacceptable biodegradation of polyethylene <i>in vivo</i>. <i>Biomaterials</i>. 1996; 17: 873-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147725&pid=S2306-4102201400050001000030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">31.	Jasty M, Rubash HE, Muratoglu O: Highly cross-linked polyethylene: the debate is over in the affirmative. <i>J Arthroplasty</i>. 2005; 20(4 Suppl. 2): 55-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147727&pid=S2306-4102201400050001000031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">32.	Collier JP, Currier BH, Kennedy FE, et al: Comparison of cross-linked polyethylene materials for orthopaedic applications. <i>Clin Orthop Relat Res</i>. 2003; (414): 289-304.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147729&pid=S2306-4102201400050001000032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Efectos de la esterilizaci&oacute;n sobre los polietilenos</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">33.	Kurtz SM, Muratoglu OK, Evans M, Edidin AA: Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. <i>Biomaterials</i>. 1999; 20: 1659-88.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147734&pid=S2306-4102201400050001000033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">34.	Kurtz SM, Rimnac CM, Hozack WH, Turner J, Marcolongo M, Goldberg VM, et al: <i>In vivo</i> degradation of polyethylene liners after gamma esterilization in air. <i>J Bone Joint Surg Am</i>. 2005; 87-A: 815-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147736&pid=S2306-4102201400050001000034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">35.	Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, et al: Otto aufranc award paper: significance of <i>in vivo</i> degradation of polyethylene in total hip arthroplasty. <i>Clin Orthop Relat Res</i>. 2006; 453: 47-57.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147738&pid=S2306-4102201400050001000035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">36. 	Affatato S, Bersaglia G, Foltran I, Taddei P, Fini G, Toni A: Performance of gamma and ETO-sterilized UHMWPE acetabular cups tested under severe simulator conditions. Part 1: role of the third body wear process. <i>Biomaterials</i>. 2002; 23: 4839-46.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147740&pid=S2306-4102201400050001000036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">37.	McKellop H, Shen FW, Lu B, Campbell P, Salovey R: Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip-simulator study. <i>J Bone Joint Surg Am</i>. 2000; 82: 1708-25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147742&pid=S2306-4102201400050001000037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">38.	McKellop HA, Shen FW, Campbell P, Ota T: Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator. <i>J Orthop Res</i>. 1999; 17: 329-39.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147744&pid=S2306-4102201400050001000038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">39.	Besong AA, Tipper JL, Ingham E, et al: Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. <i>J Bone Joint Surg Br</i>. 1998; 80-B(2): 340-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147746&pid=S2306-4102201400050001000039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">40.	McKellop H, Shen FW, Lu B, et al: Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. <i>J Bone Joint Surg Am</i>. 2000; 82-A(12): 1708-25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147748&pid=S2306-4102201400050001000040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Estudios comparativos entre cabezas femorales con diversos </b></font></p>     <p align="justify"><font face="verdana" size="2"><b>materiales y polietilenos con elevados enlaces cruzados</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">41.	Tipper JL, Gavin AL, Ingham E, Fisher J: Comparison of the wear, wear debris and functional biological activity of non-crosslinked and crosslinked GUR 1020 and GUR 1050 polyethylenes used in total hip prostheses. Trans. UHMWPE for arthroplasty: degradation, stabilization, and crosslinking. 2nd UHMWPE International Meeting. Torino, Italy: 2005.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147754&pid=S2306-4102201400050001000041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">42.	Wroblewski BM, Siney PD, Dowson D, Colling SN: Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. <i>J Bone Joint Surg Br</i>. 1996; 78: 280.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147756&pid=S2306-4102201400050001000042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">43.	Wroblewski B, Siney P, Fleming P: Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene: a ten-year follow-up report. <i>J Bone Joint Surg Br</i>. 1999; 81: 54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147758&pid=S2306-4102201400050001000043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">44. 	Oonishi H: Long term clinical results of THR: clinical results of THR of an alumina head with a cross-linked UHMWPE cup. <i>Orthop Surg Traumatol</i>. 1995; 38: 1255.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147760&pid=S2306-4102201400050001000044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">45. 	Hernigou P, Bahrami T: Zirconia and alumina ceramics in comparisson with stainless-steel heads. <i>J Bone Joint Surg </i>&#91;<i>Br</i>&#93;. 2003; 85-B: 504-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147762&pid=S2306-4102201400050001000045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">46. 	Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K: Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. <i>Medical Engineering </i>&amp;<i> Physics</i>. 1994; 16(3): 229-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147764&pid=S2306-4102201400050001000046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Complicaciones en los polietilenos altamente enlazados</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">47. 	Pruitt L, Koo J, Rimnac CM, Suresh S, Wright TM: Cyclic compressive loading results in fatigue cracks in ultra high molecular weight polyethylene. <i>J Orthop Res</i>. 1994; 13: 143.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147769&pid=S2306-4102201400050001000047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">48.	Gillis A, Schmieg J, Bhattacharyya S, Li S: An independent evaluation of the mechanical, chemical and fracture properties of UHMWPE cross linked by 34 different conditions. Society for Biomaterials. 25th Annual Meeting Transactions. Providence, RI. 1999.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147771&pid=S2306-4102201400050001000048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">49.	Bradford L, Baker DA, Graham J, Chawan A, Ries MD, Pruitt LA: Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. <i>J Bone Joint Surg Am</i>. 2004; 86(6): 1271-82.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147773&pid=S2306-4102201400050001000049&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">50. 	Bradford L, Baker D, Ries M, Pruitt LA, Hanssen A: Fatigue crack propagation resistance of highly crosslinked polyethylene. <i>Clin Orthop Rel Res.</i> 2004; 429: 68-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147775&pid=S2306-4102201400050001000050&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">51.	Tower SS, Currier JH, Currier BH, Lyford KA, Van Citters DW, Mayor MB: Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. <i>J Bone Joint Surg Am</i>. 2007; 89(10): 2212-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147777&pid=S2306-4102201400050001000051&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">52.	Matthew O, Barrett MO, Douglas D, van Citters W, Hamilton WG: Mechanical failure of marathon cross-linked polyethylene acetabular liner after total hip arthroplasty. <i>Am J of Orthop</i>. 2011; 40(10): 523-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147779&pid=S2306-4102201400050001000052&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">53.	Estok DM, Bragdon CR, Plank GR, Huang A, Muratoglu OK, Harris WH: The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. <i>J Arthroplasty</i>. 2005; 20(2): 239-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147781&pid=S2306-4102201400050001000053&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">54.	Besong AA, Hailey JL, Ingham E, et al: A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. <i>Biomed Mater Eng</i>. 1997; 7(1): 59-65.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147783&pid=S2306-4102201400050001000054&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">55.	Shen FW, McKellop H: Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls. <i>Clin Orthop Relat Res</i>. 2005; (430): 80-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147785&pid=S2306-4102201400050001000055&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">56.	Rohrl S, Nivbrant B, Mingguo L, Hewitt B: <i>In vivo</i> wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. <i>J Arthroplasty</i>. 2005; 20(4): 409-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147787&pid=S2306-4102201400050001000056&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">57.	Krushell RJ, Fingeroth RJ, Cushing MC: Early femoral head penetration of a highly cross-linked polyethylene liner versus a conventional polyethylene liner, a case-controlled study. <i>J Arthroplasty</i>. 2005; 20(Suppl. 3): 73-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147789&pid=S2306-4102201400050001000057&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Seguimiento cl&iacute;nico de polietilenos altamente cruzados</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">58. 	Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A: Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. <i>J Bone Joint Surg Am</i>. 2005; 87(8): 1816-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147794&pid=S2306-4102201400050001000058&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">59. 	Bragdon CR, Kwon YM, Geller JA, et al: Minimum 6-year follow-up of highly cross-linked polyethylene in THA. <i>Clin Orthop Relat Res</i>. 2007; 465: 122-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147796&pid=S2306-4102201400050001000059&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">60.	McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD: Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. <i>J Bone Joint Surg</i>. 2009; 91(4): 773-82.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147798&pid=S2306-4102201400050001000060&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">61.	Engh ChE Jr, Stepniewski AS, Stuart D, Ginn SD, Beykirch SE, Sychterz-Terefenko C, et al: A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked enduron polyethylene liners. <i>J Arthrop</i>. 2006; 21(6): 17-25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147800&pid=S2306-4102201400050001000061&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Polietilenos medicados con alfatocoferol</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">62.	Shibata N, Tomita N: The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance. <i>Biomaterials</i>. 2005; 26(29): 5755-62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147805&pid=S2306-4102201400050001000062&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">63.	Oral E, Greenbaum ES, Malhi AS, Harris WH, Muratoglu OK: Characterization of irradiated blends of alpha-tocopherol and UHMWPE. <i>Biomaterials</i>. 2005; 26(33): 6657-63.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147807&pid=S2306-4102201400050001000063&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">64.	Oral E, Wannomae KK, Hawkins N, Harris WH, Muratoglu OK: Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. <i>Biomaterials</i>. 2004; 25(24): 5515-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147809&pid=S2306-4102201400050001000064&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Metal-metal</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Reacciones adversas con metal-metal</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">65. 	Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, K&ouml;ster G, et al: Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints: a clinical and histomorphological study. <i>J Bone Joint Surg (A)</i>. 2005; 87: 28-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147816&pid=S2306-4102201400050001000065&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">66. 	Campbell PA, Nelson S, Tas T, et al: The immunopathology of ALVAL. AAOS 2011 Anual Meeting Scientififc Exhibit Number: SE01.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147818&pid=S2306-4102201400050001000066&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">67.	Hallab N, Merrit K, Jacobs J: Metal sensitivity in patients with orthopaedic implants. <i>J Bone Joint Surg</i>. 2001; 83-A(3): 428-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147820&pid=S2306-4102201400050001000067&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">68.	Hallab N, Mikecz K, Jacobs J: A triple assay technique for the evaluation of metal-induced, delay-type hypersensitivity responses in patients with or receiving total joint arthroplasty. <i>J Biomed Mater Res</i>. 2000; 53: 480-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147822&pid=S2306-4102201400050001000068&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">69.	Ball ST: Inflammatory cytokines are elevated in patients with adverse reactions to metal-on-metal THAs. AAOS, 2011 Meeting Podium No: 065.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147824&pid=S2306-4102201400050001000069&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">70. 	Haddad FS, et al: Metal-on-metal bearings: the evidence so far. <i>JBJS (Br)</i>. 2011; 93-B: 572-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147826&pid=S2306-4102201400050001000070&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">71.	Gonzalez MH, Carr R, Walton S, Mihalko WM: The evolution and modern use of metal-on. Metal bearings in total hip arthroplasty. <i>Inst Courses Lec</i>. 2011; 60: 247-55.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147828&pid=S2306-4102201400050001000071&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">72.	Lhotka C, Szekerea T, Steffan T, Zhubar K, Zweymuller K: Four year study of cobalt and chromium blood levels in patients managed with two different metal on metal total hip replacements. <i>J Ortho Research</i>. 2003; 21(2): 189-95.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147830&pid=S2306-4102201400050001000072&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">73.	Medicines and Healthcare products Regulatory Agency UK. Issued: 22 April 2010, Ref: MDA/2010/033.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147832&pid=S2306-4102201400050001000073&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">74.	FDA Executive Summary Memorandum Metal-on-Metal Hip Implant Systems. Prepared for the June 27-28, 2012 Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel Gaithersburg Hilton Gaithersburg, Maryland 1.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147834&pid=S2306-4102201400050001000074&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">75.	Lindgren JU, Brismar BH, Wikstrom AC: Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis. <i>J Bone Joint Surg Br</i>. 2011; 93(10): 1427-30.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147836&pid=S2306-4102201400050001000075&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">76.	Doorn PF, Mirra JM, Campbell PA, Amstutz HC: Tissue reaction to metal on metal total hip prostheses. <i>Clin Orthop Relat Res</i>. 1996; (329 Suppl.): S187-205.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147838&pid=S2306-4102201400050001000076&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">77.	Mahendra G, Pandit H, Kliskey K, Murray D, Gill HS, Athanasou N: Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. <i>Acta Orthop</i>. 2009; 80(6): 653-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147840&pid=S2306-4102201400050001000077&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Seudotumores en pr&oacute;tesis metal-metal</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">78. 	Beaul&eacute; PE, Kim PR, Powell J, Mackenzie J, et al: A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers. <i>J Bone Joint Surg Am</i>. 2011; 93(Suppl. 2): 118-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147845&pid=S2306-4102201400050001000078&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">79.	Glyn-Jones S, Pandit H, Kwon YM, Doll H, Gill HS, Murray DW: Risk factors for inflammatory pseudotumour formation following hip resurfacing. <i>J Bone Joint Surg Br</i>. 2009; 91(12): 1566-74.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147847&pid=S2306-4102201400050001000079&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">80. 	Kwon YM, Ostlere SJ, McLardy-Smith P, et al: "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. <i>J Arthroplasty</i>. 2011; 26(4): 511-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147849&pid=S2306-4102201400050001000080&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">81.	Pandit H, Glyn-Jones S, McLardy P, Gundle R, Whitwell D, Gibbons CL, et al: Pseudotumours associated with metal-on-metal hip resurfacings. <i>J Bone Joint Surg Br</i>. 2008; 90(7): 847-51.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147851&pid=S2306-4102201400050001000081&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">82.	Walsh AJ, Nikolaou VS, Antoniou J: Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. <i>J Arthroplasty</i>. 2012; 27(2): 324, e5-8. Epub 2011 Apr 16.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147853&pid=S2306-4102201400050001000082&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">83.	Svensson O, Mathiesen EB, Reinholt FP, Blomgren G: Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report. <i>J Bone Joint Surg Am</i>. 1988; 70(8): 1238-42.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147855&pid=S2306-4102201400050001000083&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">84.	Campbell P, Ebramzadeh E, Nelson S, Takamura K, De Smet K, Amstutz HC: Histological features of pseudotumor-like tissues from metal-on-metal hips. <i>Clin Orthop Relat Res</i>. 2010; 468(9): 2321-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147857&pid=S2306-4102201400050001000084&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Corrosi&oacute;n y efectos indeseables en implantes metal-metal</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">85.	Cooper HJ, Della-Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM, et al: Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. <i>J Bone Joint Surg Am</i>. 2012; 94(18): 1655-61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147862&pid=S2306-4102201400050001000085&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">86.	Jacobs JJ, Urban RM, Gilbert JL, Skipor AK, Black J, Jasty M, et al: Local and distant products from modularity. <i>Clin Orthop Relat Res</i>. 1995; (319): 94-105.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147864&pid=S2306-4102201400050001000086&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">87.	Collier JP, Mayor MB, Williams IR, Surprenant VA, Surprenant HP, Currier BH: The tradeoffs associated with modular hip prostheses. <i>Clin Orthop Relat Res</i>. 1995; (311): 91-101.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147866&pid=S2306-4102201400050001000087&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">88.	Cook SD, Barrack RL, Baffes GC, Clemow AJ, Serekian P, Dong N, et al: Wear and corrosion of modular interfaces in total hip replacements. <i>Clin Orthop Relat Res</i>. 1994; (298): 80-8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147868&pid=S2306-4102201400050001000088&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">89.	Collier JP, Surprenant VA, Jensen RE, Mayor MB: Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. <i>Clin Orthop Relat Res</i>. 1991; (271): 305-12.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147870&pid=S2306-4102201400050001000089&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">90.	Kop AM, Swarts E: Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. <i>J Arthroplasty</i>. 2009; 24(7): 1019-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147872&pid=S2306-4102201400050001000090&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">91. 	Gilbert JL, Buckley CA, Jacobs JJ: <i>In vivo</i> corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. <i>J Biomed Mater Res</i>. 1993; 27(12): 1533-44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147874&pid=S2306-4102201400050001000091&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">92. 	Gilbert JL, Buckley CA, Jacobs JJ, Bertin KC, Zernich MR: Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. <i>J Bone Joint Surg Am</i>. 1994; 76(1): 110-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147876&pid=S2306-4102201400050001000092&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">93.	Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S: A multicenter retrieval study of the taper interfaces of modular hip prostheses. <i>Clin Orthop Relat Res</i>. 2002; (401): 149-61.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147878&pid=S2306-4102201400050001000093&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">94.	Goldberg JR, Gilbert JL: <i>In vitro</i> corrosion testing of modular hip tapers. <i>J Biomed Mater Res</i> <i>B Appl Biomater</i>. 2003; 64(2): 78-93.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147880&pid=S2306-4102201400050001000094&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">95.	Kawalec JS, Brown SA, Payer JH, Merritt K: Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy. <i>J Biomed Mater Res</i>. 1995; 29(7): 867-73.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147882&pid=S2306-4102201400050001000095&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">96. 	Kretzer JP, Jakubowitz E, Krachler M, Thomsen M, Heisel C: Metal release and corrosion effects of modular neck total hip arthroplasty. <i>Int Orthop</i>. 2009; 33(6): 1531-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147884&pid=S2306-4102201400050001000096&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref -->  </font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">97.	Mroczkowski ML, Hertzler JS, Humphrey SM, Johnson T, Blanchard CR: Effect of impact assembly on the fretting corrosion of modular hip tapers. <i>J Orthop Res</i>. 2006; 24(2): 271-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147886&pid=S2306-4102201400050001000097&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">98.	Collier JP, Surprenant VA, Jensen RE, Mayor MB, Surprenant HP: Corrosion between the components of modular femoral hip prostheses. <i>J Bone Joint Surg Br</i>. 1992; 74(4): 511-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147888&pid=S2306-4102201400050001000098&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">99.	Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE: Concerns with modularity in total hip arthroplasty. <i>Clin Orthop Relat Res</i>. 1994; (298): 27-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147890&pid=S2306-4102201400050001000099&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">100.	Brown SA, Flemming CA, Kawalec JS, Placko HE, Vassaux C, Merritt K, et al: Fretting corrosion accelerates crevice corrosion of modular hip tapers. <i>J Appl Biomater</i>. 1995; 6(1): 19-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147892&pid=S2306-4102201400050001000100&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">101.	Cook SD, Barrack RL, Clemow AJ: Corrosion and wear at the modular interface of uncemented femoral stems. <i>J Bone Joint Surg Br</i>. 1994; 76(1): 68-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147894&pid=S2306-4102201400050001000101&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">102.	Lieberman JR, Rimnac CM, Garvin KL, Klein RW, Salvati EA: An analysis of the head-neck taper interface in retrieved hip prostheses. <i>Clin Orthop Relat Res</i>. 1994; (300): 162-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147896&pid=S2306-4102201400050001000102&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">103.	Mathiesen EB, Lindgren JU, Blomgren GG, Reinholt FP: Corrosion of modular hip prostheses. <i>J Bone Joint Surg Br</i>. 1991; 73(4): 569-75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147898&pid=S2306-4102201400050001000103&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">104.	Urban RM, Jacobs JJ, Gilbert JL, Galante JO: Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. <i>J Bone Joint Surg Am</i>. 1994; 76(9): 1345-59.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147900&pid=S2306-4102201400050001000104&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Cer&aacute;mica-cer&aacute;mica</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">105.	Skinner HB: Ceramic bearing surfaces. &#91;Review&#93; &#91;50 refs&#93; <i>Clin Orthop</i>o <i>Rel Res</i>. 1999; 83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147905&pid=S2306-4102201400050001000105&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">106.	Hannouche D, et al: Ceramics in total hip replacement &#91;report&#93;. <i>Clin Orthop Relat Res</i>. 2005; 430: 62.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147907&pid=S2306-4102201400050001000106&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">107.	Hamadouche MB, Daussange P, Bolander J, et al: Alumina on alumina total hip arthroplasty: a minimum 18.5-years follow-up study &#91;Article&#93;. <i>J Bone Joint Surg Am</i>. 2002; 84-A: 69.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147909&pid=S2306-4102201400050001000107&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">108.	Bierbaum BE, et al: Ceramic on ceramic bearings in total hip arthroplasty. <i>Clin Orthop Relat Res</i>. 1999; 83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147911&pid=S2306-4102201400050001000108&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">109.	Yoo JJ, et al: Alumina on alumina total hip arthroplasty: a five years minimum follow-up study. <i>J Bone and Joint Surg Am</i>. 2005; 87-A: 530.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147913&pid=S2306-4102201400050001000109&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">110.	Chevalier J: What future for zirconia as a biomaterial? <i>Biomaterials</i>. 2006; 27(4): 535-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147915&pid=S2306-4102201400050001000110&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">111.	Dalla-Pria P: Evolution and new application of the alumina ceramics in joint replacement. <i>European Journal of Orthopaedic Surgery </i>&amp;<i> Traumatology</i>. 17(3): 253-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147917&pid=S2306-4102201400050001000111&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">112.	Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J: THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. <i>Clin Orthop Relat Res</i>. 2010; 468(2): 358-66.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147919&pid=S2306-4102201400050001000112&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Complicaciones con cer&aacute;mica-cer&aacute;mica</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">113.	Barrack RL, Burak C, Skinner HB: Concerns about ceramics in THA. <i>Cl Orthop</i> <i>Rel Res</i>. 2004; 429: 73-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147924&pid=S2306-4102201400050001000113&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">114.	Capello WN, D'Antonio JA, Manley MT: Alumina-on-alumina bearings in total hip arthroplasty: clinical results, osteolysis, breakage, and noise. <i>J Arthroplasty</i>. 2007; 22: 311.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147926&pid=S2306-4102201400050001000114&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">115.	Glaser D, Komistek RD, Cates HE, Mahfouz MR: Clicking and squeaking: <i>in vivo</i> correlation of sound and separation for different bearing surfaces. <i>J Bone Joint Surg Am</i>. 2008; 90(Suppl. 4): 112-20.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147928&pid=S2306-4102201400050001000115&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">116.	Rosneck J, Klika A, Barsoum W: A rare complication of ceramic-on-ceramic bearings in total hip arthoplasty. <i>J Arthoplasty</i>. 2008; 23: 311.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147930&pid=S2306-4102201400050001000116&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">117.	Jarrett CA, Ranawat A, Bruzzone M, Rodriguez J, Ranawat C: The squeaking hip: an underreported phenomenon of ceramic-on-ceramic total hip arthroplasty. <i>J Arthroplasty</i>. 2007; 22: 302.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147932&pid=S2306-4102201400050001000117&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">118.	Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH: The noisy ceramic hip: is component malpositioning the cause? <i>J Arthroplasty</i>. 2008; 23: 643-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147934&pid=S2306-4102201400050001000118&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">119.	Walter WL, O'Toole GC, Walter WK, Ellis A, Zicat BA: Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. <i>J Arthroplasty</i>. 2007; 22: 496-503.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147936&pid=S2306-4102201400050001000119&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">120.	Chevillotte C, Trousdale RT, Chen Q, Guyen O, An KN: The 2009 frank stinchfield award: "hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces. <i>Clin Orthop Relat Res</i>. 2010; 468: 345-50.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147938&pid=S2306-4102201400050001000120&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">121.	Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW: High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. <i>Clin Orthop Relat Res</i>. 2008; 466: 1438-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147940&pid=S2306-4102201400050001000121&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">122.	Murphy SB, Ecker TM, Tannast M: Incidence of squeaking after alumina ceramic-ceramic total hip arthroplasty. <i>J Arthroplasty</i>. 2008; 23: 327.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147942&pid=S2306-4102201400050001000122&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">123.	Restrepo C, Post Z, Kai B, Hozack WJ: The effect of stem design on the incidence of squeaking in ceramic on ceramic bearing total hip arthroplasty. <i>J Bone Joint Surg Am</i>. 2010; 92(3): 550-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147944&pid=S2306-4102201400050001000123&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">124.	Walter WL, Waters TS, Gillies M, Donohoo S, Kurtz SM, Ranawat AS, et al: Squeaking hips. <i>J Bone Joint Surg Am</i>. 2008; 90(Suppl. 4): 102-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147946&pid=S2306-4102201400050001000124&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <p align="justify"><font face="verdana" size="2"><b>Metales ceramizados</b></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">125.	Hunter G, Dickinson J, Herb B, et al: Creation of oxidized zirconium orthopaedic implants. <i>J ATSM Int</i>. 2005; 2(7).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147951&pid=S2306-4102201400050001000125&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">126.	Long M, Riester L, Hunter G: Nano-hardness measurements of oxidized Zr-2.5Nb and various orthopaedic materials. <i>Trans Soc</i> <i>Biomaterials</i>. 1998; 21: 528.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147953&pid=S2306-4102201400050001000126&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">127.	Good V, Ries M, Barrack RL, et al: Reduced wear with oxidized zirconium femoral heads. <i>J Bone Joint Surg</i>. 2003; 85-A(suppl. 4): 105-10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147955&pid=S2306-4102201400050001000127&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">128.	Nasser S, Mott M, Wooley P: A prospective comparison of ceramic and oxinium TKA components in metal hypersensitivity patients. San Diego, CA: Proceedings of the Annual Meeting of the American Academy of Orthopaedic Surgeons; 2006: 194.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147957&pid=S2306-4102201400050001000128&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">129.	Kop AM, Colin-Whitewood C, Johnston DJL: Damage of Oxinium femoral heads subsequent to hip arthroplasty dislocation: three retrieval case studies. <i>J Arthroplasty</i>. 2007; 22(5): 775-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147959&pid=S2306-4102201400050001000129&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">130.	Evangelista GT, Fulkerson E, Kummer F, Di Cesare PE: Surface damage to an Oxinium femoral head prosthesis after dislocation. <i>J Bone Joint Surg Br</i>. 2007; 89(4): 535-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147961&pid=S2306-4102201400050001000130&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">131.	McCalden RW, Charron KD, Davidson RD, Teeter MG, Holdsworth DW: Damage of an Oxinium femoral head and polyethylene liner following "routine" total hip replacement. <i>J Bone Joint Surg Br</i>. 2011; 93(3): 409-13.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=147963&pid=S2306-4102201400050001000131&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <p align="justify"><font face="verdana" size="2"></font></p>    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">      <br> <b>Nota</b>     <br>           <br> Este art&iacute;culo puede ser consultado en versi&oacute;n completa en: <a href="http://www.medigraphic.com/actaortopedica" target="_blank">http://<b>www.medigraphic.com/actaortopedica</b></a></font></p>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wear and periprosthetic osteolysis: the problem]]></article-title>
<source><![CDATA[Clin Orthop]]></source>
<year>2001</year>
<volume>393</volume>
<page-range>66-70</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santavirta]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bohler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alternative materials to improve total hip replacement tribology]]></article-title>
<source><![CDATA[Acta Orthop Scand]]></source>
<year>2003</year>
<volume>74</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>380-8</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[GF:]]></given-names>
</name>
</person-group>
<source><![CDATA[Estado actual de la prótesis femoral de cadera: SLA una consecuencia lógica en artroplastia total de cadera]]></source>
<year>2000</year>
<publisher-name><![CDATA[McGraw Hill Interamericana]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Atkinson]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Dowling]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Cicek]]></surname>
<given-names><![CDATA[RZ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Materials for internal prostheses: the present position and possible future developments]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1980</year>
<volume>1</volume>
<page-range>89</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sychterz]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Young]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Orishimo]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Engh]]></surname>
<given-names><![CDATA[CA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The relationship between shelf life and in vivo wear for polyethylene acetabular liners]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<page-range>168-73</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM:]]></given-names>
</name>
</person-group>
<source><![CDATA[The UHMWPE handbook: ultra-high molecular weight polyethylene in total joint replacement]]></source>
<year>2004</year>
<page-range>4, 6</page-range><publisher-loc><![CDATA[San Diego^eCA CA]]></publisher-loc>
<publisher-name><![CDATA[Elsevier Academic Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Callaghan]]></surname>
<given-names><![CDATA[JJ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Polyethylene: Chapter 7]]></article-title>
<source><![CDATA[The adult hip]]></source>
<year>1998</year>
<publisher-loc><![CDATA[Philadelphia ]]></publisher-loc>
<publisher-name><![CDATA[Lippincott-Raven]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heisel]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schmalzried]]></surname>
<given-names><![CDATA[TP:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo wear of bilateral total hip replacements: conventional versus crosslinked polyethylene]]></article-title>
<source><![CDATA[Arch Orthop Trauma Surg]]></source>
<year>2005</year>
<volume>125</volume>
<page-range>555-7</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Geerdinck]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Grimm]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Ramakrishnan]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Rondhuis]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Verburg]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tonino]]></surname>
<given-names><![CDATA[AJ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Crosslinked polyethylene compared to conventional polyethylene in total hip replacement: pre-clinical evaluation, in vitro testing and prospective clinical follow-up study]]></article-title>
<source><![CDATA[Acta Orthop]]></source>
<year>2006</year>
<volume>77</volume>
<page-range>719-25</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A review of current cross-linked polyethylenes used in total joint arthroplasty]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2005</year>
<volume>430</volume>
<page-range>46-52</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ries]]></surname>
<given-names><![CDATA[MD:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Highly cross-linked polyethylene: the debate is over in opposition]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<numero>4^s2</numero>
<issue>4^s2</issue>
<supplement>2</supplement>
<page-range>59-62</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobson]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Bracco]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidation of orthopaedic UHMWPE]]></article-title>
<source><![CDATA[Biomaterials.]]></source>
<year>2002</year>
<volume>23</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1613-24</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Luda]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
<name>
<surname><![CDATA[Trossarelli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oxidation in orthopaedic UHMWPE sterilised by gamma-radiation and ethylene oxide]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1998</year>
<volume>19</volume>
<numero>7-9</numero>
<issue>7-9</issue>
<page-range>659-68</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Luda]]></surname>
<given-names><![CDATA[MP]]></given-names>
</name>
<name>
<surname><![CDATA[Trossarelli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo UHMWPE biodegradation of retrieved prosthesis]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1998</year>
<volume>19</volume>
<numero>15</numero>
<issue>15</issue>
<page-range>1371-85</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[CD]]></given-names>
</name>
<name>
<surname><![CDATA[D'Lima]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Clifford]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Colwell]]></surname>
<given-names><![CDATA[CW Jr:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Highly cross-linked polyethylene in total hip arthroplasty]]></article-title>
<source><![CDATA[J of the Am Acad Orthop Surg]]></source>
<year>2006</year>
<volume>4</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>511-23</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chiesa]]></surname>
<given-names><![CDATA[RMM]]></given-names>
</name>
<name>
<surname><![CDATA[Giordano]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Siccardi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Cigada]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of heat treatment on structural, mechanical and wear properties of crosslinked UHMWPE]]></article-title>
<source><![CDATA[Journal of Applied Biomaterials and Biomechanics]]></source>
<year>2004</year>
<volume>2</volume>
<page-range>20-8</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKellop]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Salovey]]></surname>
<given-names><![CDATA[R:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development of an extremley resistant high molecular weight polyethylene for total hip replacements]]></article-title>
<source><![CDATA[J Orthop Res]]></source>
<year>1999</year>
<volume>17</volume>
<page-range>157-67</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grobbelaar]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Plessis]]></surname>
<given-names><![CDATA[TAD]]></given-names>
</name>
<name>
<surname><![CDATA[Marais]]></surname>
<given-names><![CDATA[F:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The radiation improvement of polyethylene prostheses]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1978</year>
<volume>60</volume>
<page-range>370</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grobbelaar]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Weber]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Spirakis]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[DuPlessis]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
<name>
<surname><![CDATA[Cappert]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cakic]]></surname>
<given-names><![CDATA[JN:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical experience with gamma irradiation-crosslinked polyethylene-A 14 to 20 year follow-up report]]></article-title>
<source><![CDATA[S Afr Bone Joint Surg]]></source>
<year>1999</year>
<volume>11</volume>
<page-range>140</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oonishi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Takayama]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tsuji]]></surname>
<given-names><![CDATA[E:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improvement of polyethylene by irradiation in artificial joints]]></article-title>
<source><![CDATA[Radiat Phys Chem]]></source>
<year>1992</year>
<volume>39</volume>
<page-range>495</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK]]></given-names>
</name>
<name>
<surname><![CDATA[Bragdon]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[O'Connor]]></surname>
<given-names><![CDATA[DO]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1999</year>
<volume>20</volume>
<page-range>1463</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2004</year>
<volume>429</volume>
<page-range>63-7</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Charlesby]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cross-linking of polythene by pile radiation]]></article-title>
<source><![CDATA[Proc Roy Soc Lond A]]></source>
<year>1952</year>
<volume>215</volume>
<page-range>187</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Boer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Pennings]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Crosslinking of ultra-high molecular weight polyethylene in the melt by means of 2.5-dimethyl-2.5-bis (tert-butyldioxy)-3-hexyne: 2. Crystallization behaviour and mechanical properties]]></article-title>
<source><![CDATA[Polymer]]></source>
<year>1982</year>
<month>19</month>
<day>44</day>
<volume>23</volume>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Atkinson]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Cicek]]></surname>
<given-names><![CDATA[RZ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Silane cross-linked polyethylene for prosthetic applications: Part I. Certain physical and mechanical properties related to the nature of the material]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1983</year>
<volume>4</volume>
<page-range>267</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Atkinson]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Cicek]]></surname>
<given-names><![CDATA[RZ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Silane cross-linked polyethylene for prosthetic applications: Part II. Creep and wear behavior and a preliminary molding test]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1984</year>
<volume>5</volume>
<page-range>326</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK]]></given-names>
</name>
<name>
<surname><![CDATA[Bragdon]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[O'Connor]]></surname>
<given-names><![CDATA[DO]]></given-names>
</name>
<name>
<surname><![CDATA[Merri]]></surname>
<given-names><![CDATA[EW]]></given-names>
</name>
<name>
<surname><![CDATA[Jasty]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electron beam crosslinking of UHMWPE at room temperature, a candidate bearing material for total joint arthroplasty]]></article-title>
<source><![CDATA[23rd Annual Meeting of the Society for Biomaterials]]></source>
<year>1997</year>
<publisher-loc><![CDATA[New Orleans ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baker]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Hastings]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
<name>
<surname><![CDATA[Pruitt]]></surname>
<given-names><![CDATA[L:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1999</year>
<volume>46</volume>
<page-range>573</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[DiMaio]]></surname>
<given-names><![CDATA[WG]]></given-names>
</name>
<name>
<surname><![CDATA[Lilly]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Saun]]></surname>
<given-names><![CDATA[KA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Low wear, low oxidation radiation crosslinked UHMWPE]]></article-title>
<source><![CDATA[44th Annual Meeting Proceedings of Orthopaedic Research Society]]></source>
<year>1998</year>
<page-range>363</page-range><publisher-loc><![CDATA[New Orleans ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brach del Prever]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Crova]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Unacceptable biodegradation of polyethylene in vivo]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1996</year>
<volume>17</volume>
<page-range>873-8</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jasty]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rubash]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[O:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Highly cross-linked polyethylene: the debate is over in the affirmative]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<numero>4^s2</numero>
<issue>4^s2</issue>
<supplement>2</supplement>
<page-range>55-8</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collier]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Currier]]></surname>
<given-names><![CDATA[BH]]></given-names>
</name>
<name>
<surname><![CDATA[Kennedy]]></surname>
<given-names><![CDATA[FE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of cross-linked polyethylene materials for orthopaedic applications]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2003</year>
<volume>414</volume>
<page-range>289-304</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK]]></given-names>
</name>
<name>
<surname><![CDATA[Evans]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Edidin]]></surname>
<given-names><![CDATA[AA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1999</year>
<volume>20</volume>
<page-range>1659-88</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Rimnac]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Hozack]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Turner]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Marcolongo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[VM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo degradation of polyethylene liners after gamma esterilization in air]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2005</year>
<volume>87</volume>
<page-range>815-23</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Hozack]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Purtill]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Marcolongo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kraay]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[VM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Otto aufranc award paper: significance of in vivo degradation of polyethylene in total hip arthroplasty]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2006</year>
<volume>453</volume>
<page-range>47-57</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Affatato]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bersaglia]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Foltran]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Taddei]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Fini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Toni]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance of gamma and ETO-sterilized UHMWPE acetabular cups tested under severe simulator conditions: Part 1: role of the third body wear process]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2002</year>
<volume>23</volume>
<page-range>4839-46</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKellop]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Salovey]]></surname>
<given-names><![CDATA[R:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip-simulator study]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2000</year>
<volume>82</volume>
<page-range>1708-25</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKellop]]></surname>
<given-names><![CDATA[HA]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ota]]></surname>
<given-names><![CDATA[T:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator]]></article-title>
<source><![CDATA[J Orthop Res]]></source>
<year>1999</year>
<volume>17</volume>
<page-range>329-39</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Besong]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Tipper]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Ingham]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1998</year>
<volume>80</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>340-4</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKellop]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: A hip-simulator study]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2000</year>
<volume>82</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1708-25</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tipper]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Gavin]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Ingham]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<source><![CDATA[Comparison of the wear, wear debris and functional biological activity of non-crosslinked and crosslinked GUR 1020 and GUR 1050 polyethylenes used in total hip prostheses: Trans. UHMWPE for arthroplasty: degradation, stabilization, and crosslinking. 2nd UHMWPE International Meeting]]></source>
<year>2005</year>
<publisher-loc><![CDATA[Torino ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wroblewski]]></surname>
<given-names><![CDATA[BM]]></given-names>
</name>
<name>
<surname><![CDATA[Siney]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[Dowson]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Colling]]></surname>
<given-names><![CDATA[SN:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1996</year>
<volume>78</volume>
<page-range>280</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wroblewski]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Siney]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Fleming]]></surname>
<given-names><![CDATA[P:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene: a ten-year follow-up report]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1999</year>
<volume>81</volume>
<page-range>54</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oonishi]]></surname>
<given-names><![CDATA[H:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long term clinical results of THR: clinical results of THR of an alumina head with a cross-linked UHMWPE cup]]></article-title>
<source><![CDATA[Orthop Surg Traumatol]]></source>
<year>1995</year>
<volume>38</volume>
<page-range>1255</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernigou]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bahrami]]></surname>
<given-names><![CDATA[T:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Zirconia and alumina ceramics in comparisson with stainless-steel heads]]></article-title>
<source><![CDATA[J Bone Joint Surg [Br]]]></source>
<year>2003</year>
<volume>85</volume>
<page-range>504-9</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Derbyshire]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Fisher]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dowson]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Hardaker]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Brummitt]]></surname>
<given-names><![CDATA[K:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints]]></article-title>
<source><![CDATA[Medical Engineering & Physics]]></source>
<year>1994</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>229-36</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pruitt]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Koo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rimnac]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Suresh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wright]]></surname>
<given-names><![CDATA[TM:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cyclic compressive loading results in fatigue cracks in ultra high molecular weight polyethylene]]></article-title>
<source><![CDATA[J Orthop Res]]></source>
<year>1994</year>
<volume>13</volume>
<page-range>143</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gillis]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Schmieg]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bhattacharyya]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[S:]]></given-names>
</name>
</person-group>
<source><![CDATA[An independent evaluation of the mechanical, chemical and fracture properties of UHMWPE cross linked by 34 different conditions: Society for Biomaterials. 25th Annual Meeting Transactions]]></source>
<year>1999</year>
<publisher-loc><![CDATA[Providence, RI ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bradford]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Baker]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Graham]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Chawan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ries]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
<name>
<surname><![CDATA[Pruitt]]></surname>
<given-names><![CDATA[LA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2004</year>
<volume>86</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1271-82</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bradford]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Baker]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ries]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Pruitt]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Hanssen]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fatigue crack propagation resistance of highly crosslinked polyethylene]]></article-title>
<source><![CDATA[Clin Orthop Rel Res]]></source>
<year>2004</year>
<volume>429</volume>
<page-range>68-72</page-range></nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tower]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Currier]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Currier]]></surname>
<given-names><![CDATA[BH]]></given-names>
</name>
<name>
<surname><![CDATA[Lyford]]></surname>
<given-names><![CDATA[KA]]></given-names>
</name>
<name>
<surname><![CDATA[Van Citters]]></surname>
<given-names><![CDATA[DW]]></given-names>
</name>
<name>
<surname><![CDATA[Mayor]]></surname>
<given-names><![CDATA[MB:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2007</year>
<volume>89</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>2212-7</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matthew]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Barrett]]></surname>
<given-names><![CDATA[MO]]></given-names>
</name>
<name>
<surname><![CDATA[Douglas]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[van Citters]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Hamilton]]></surname>
<given-names><![CDATA[WG:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical failure of marathon cross-linked polyethylene acetabular liner after total hip arthroplasty]]></article-title>
<source><![CDATA[Am J of Orthop]]></source>
<year>2011</year>
<volume>40</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>523-26</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Estok]]></surname>
<given-names><![CDATA[DM]]></given-names>
</name>
<name>
<surname><![CDATA[Bragdon]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Plank]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>239-43</page-range></nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Besong]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Hailey]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Ingham]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE]]></article-title>
<source><![CDATA[Biomed Mater Eng]]></source>
<year>1997</year>
<volume>7</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>59-65</page-range></nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
<name>
<surname><![CDATA[McKellop]]></surname>
<given-names><![CDATA[H:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2005</year>
<volume>430</volume>
<page-range>80-8</page-range></nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rohrl]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Nivbrant]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Mingguo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hewitt]]></surname>
<given-names><![CDATA[B:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>409-13</page-range></nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Krushell]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Fingeroth]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cushing]]></surname>
<given-names><![CDATA[MC:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Early femoral head penetration of a highly cross-linked polyethylene liner versus a conventional polyethylene liner, a case-controlled study]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2005</year>
<volume>20</volume>
<numero>^s3</numero>
<issue>^s3</issue>
<supplement>3</supplement>
<page-range>73-6</page-range></nlm-citation>
</ref>
<ref id="B58">
<label>58</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dorr]]></surname>
<given-names><![CDATA[LD]]></given-names>
</name>
<name>
<surname><![CDATA[Wan]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Shahrdar]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Sirianni]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Boutary]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Yun]]></surname>
<given-names><![CDATA[A:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2005</year>
<volume>87</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1816-21</page-range></nlm-citation>
</ref>
<ref id="B59">
<label>59</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bragdon]]></surname>
<given-names><![CDATA[CR]]></given-names>
</name>
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[YM]]></given-names>
</name>
<name>
<surname><![CDATA[Geller]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Minimum 6-year follow-up of highly cross-linked polyethylene in THA]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2007</year>
<volume>465</volume>
<page-range>122-7</page-range></nlm-citation>
</ref>
<ref id="B60">
<label>60</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCalden]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[MacDonald]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Rorabeck]]></surname>
<given-names><![CDATA[CH]]></given-names>
</name>
<name>
<surname><![CDATA[Bourne]]></surname>
<given-names><![CDATA[RB]]></given-names>
</name>
<name>
<surname><![CDATA[Chess]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
<name>
<surname><![CDATA[Charron]]></surname>
<given-names><![CDATA[KD:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial]]></article-title>
<source><![CDATA[J Bone Joint Surg]]></source>
<year>2009</year>
<volume>91</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>773-82</page-range></nlm-citation>
</ref>
<ref id="B61">
<label>61</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Engh]]></surname>
<given-names><![CDATA[ChE Jr]]></given-names>
</name>
<name>
<surname><![CDATA[Stepniewski]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Stuart]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ginn]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Beykirch]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Sychterz-Terefenko]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked enduron polyethylene liners]]></article-title>
<source><![CDATA[J Arthrop]]></source>
<year>2006</year>
<volume>21</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>17-25</page-range></nlm-citation>
</ref>
<ref id="B62">
<label>62</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shibata]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Tomita]]></surname>
<given-names><![CDATA[N:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2005</year>
<volume>26</volume>
<numero>29</numero>
<issue>29</issue>
<page-range>5755-62</page-range></nlm-citation>
</ref>
<ref id="B63">
<label>63</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oral]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Greenbaum]]></surname>
<given-names><![CDATA[ES]]></given-names>
</name>
<name>
<surname><![CDATA[Malhi]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Characterization of irradiated blends of alpha-tocopherol and UHMWPE]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2005</year>
<volume>26</volume>
<numero>33</numero>
<issue>33</issue>
<page-range>6657-63</page-range></nlm-citation>
</ref>
<ref id="B64">
<label>64</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oral]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Wannomae]]></surname>
<given-names><![CDATA[KK]]></given-names>
</name>
<name>
<surname><![CDATA[Hawkins]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Muratoglu]]></surname>
<given-names><![CDATA[OK:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2004</year>
<volume>25</volume>
<numero>24</numero>
<issue>24</issue>
<page-range>5515-22</page-range></nlm-citation>
</ref>
<ref id="B65">
<label>65</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Willert]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
<name>
<surname><![CDATA[Buchhorn]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
<name>
<surname><![CDATA[Fayyazi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Flury]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Windler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Köster]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints: a clinical and histomorphological study]]></article-title>
<source><![CDATA[J Bone Joint Surg (A)]]></source>
<year>2005</year>
<volume>87</volume>
<page-range>28-36</page-range></nlm-citation>
</ref>
<ref id="B66">
<label>66</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Nelson]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Tas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[The immunopathology of ALVAL. AAOS 2011 Anual Meeting Scientififc Exhibit Number: SE01]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B67">
<label>67</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hallab]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Merrit]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metal sensitivity in patients with orthopaedic implants]]></article-title>
<source><![CDATA[J Bone Joint Surg]]></source>
<year>2001</year>
<volume>83</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>428-36</page-range></nlm-citation>
</ref>
<ref id="B68">
<label>68</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hallab]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Mikecz]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A triple assay technique for the evaluation of metal-induced, delay-type hypersensitivity responses in patients with or receiving total joint arthroplasty]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>2000</year>
<volume>53</volume>
<page-range>480-9</page-range></nlm-citation>
</ref>
<ref id="B69">
<label>69</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ball]]></surname>
<given-names><![CDATA[ST:]]></given-names>
</name>
</person-group>
<source><![CDATA[Inflammatory cytokines are elevated in patients with adverse reactions to metal-on-metal THAs]]></source>
<year>2011</year>
<publisher-name><![CDATA[AAOS]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B70">
<label>70</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haddad]]></surname>
<given-names><![CDATA[FS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metal-on-metal bearings: the evidence so far]]></article-title>
<source><![CDATA[JBJS (Br)]]></source>
<year>2011</year>
<volume>93</volume>
<page-range>572-9</page-range></nlm-citation>
</ref>
<ref id="B71">
<label>71</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gonzalez]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Carr]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Walton]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mihalko]]></surname>
<given-names><![CDATA[WM:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The evolution and modern use of metal-on: Metal bearings in total hip arthroplasty]]></article-title>
<source><![CDATA[Inst Courses Lec]]></source>
<year>2011</year>
<volume>60</volume>
<page-range>247-55</page-range></nlm-citation>
</ref>
<ref id="B72">
<label>72</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lhotka]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Szekerea]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Steffan]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zhubar]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Zweymuller]]></surname>
<given-names><![CDATA[K:]]></given-names>
</name>
</person-group>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B73">
<label>73</label><nlm-citation citation-type="">
<source><![CDATA[Medicines and Healthcare products Regulatory Agency UK]]></source>
<year>22 A</year>
<month>pr</month>
<day>il</day>
</nlm-citation>
</ref>
<ref id="B74">
<label>74</label><nlm-citation citation-type="book">
<collab>FDA</collab>
<source><![CDATA[Executive Summary Memorandum Metal-on-Metal Hip Implant Systems: Prepared for the June 27-28, 2012 Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel]]></source>
<year></year>
<publisher-loc><![CDATA[Gaithersburg^eMaryland 1 Maryland 1]]></publisher-loc>
<publisher-name><![CDATA[Gaithersburg Hilton]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B75">
<label>75</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lindgren]]></surname>
<given-names><![CDATA[JU]]></given-names>
</name>
<name>
<surname><![CDATA[Brismar]]></surname>
<given-names><![CDATA[BH]]></given-names>
</name>
<name>
<surname><![CDATA[Wikstrom]]></surname>
<given-names><![CDATA[AC:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>2011</year>
<volume>93</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1427-30</page-range></nlm-citation>
</ref>
<ref id="B76">
<label>76</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Doorn]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
<name>
<surname><![CDATA[Mirra]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Amstutz]]></surname>
<given-names><![CDATA[HC:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tissue reaction to metal on metal total hip prostheses]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1996</year>
<numero>^s329</numero>
<issue>^s329</issue>
<supplement>329</supplement>
<page-range>S187-205</page-range></nlm-citation>
</ref>
<ref id="B77">
<label>77</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mahendra]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Pandit]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kliskey]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gill]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
<name>
<surname><![CDATA[Athanasou]]></surname>
<given-names><![CDATA[N:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties]]></article-title>
<source><![CDATA[Acta Orthop]]></source>
<year>2009</year>
<volume>80</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>653-9</page-range></nlm-citation>
</ref>
<ref id="B78">
<label>78</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beaulé]]></surname>
<given-names><![CDATA[PE]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Powell]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mackenzie]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2011</year>
<volume>93</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>118-21</page-range></nlm-citation>
</ref>
<ref id="B79">
<label>79</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Glyn-Jones]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Pandit]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[YM]]></given-names>
</name>
<name>
<surname><![CDATA[Doll]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Gill]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[DW:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Risk factors for inflammatory pseudotumour formation following hip resurfacing]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>2009</year>
<volume>91</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1566-74</page-range></nlm-citation>
</ref>
<ref id="B80">
<label>80</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[YM]]></given-names>
</name>
<name>
<surname><![CDATA[Ostlere]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[McLardy-Smith]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA["Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2011</year>
<volume>26</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>511-8</page-range></nlm-citation>
</ref>
<ref id="B81">
<label>81</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pandit]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Glyn-Jones]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[McLardy]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Gundle]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Whitwell]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gibbons]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pseudotumours associated with metal-on-metal hip resurfacings]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>2008</year>
<volume>90</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>847-51</page-range></nlm-citation>
</ref>
<ref id="B82">
<label>82</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walsh]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Nikolaou]]></surname>
<given-names><![CDATA[VS]]></given-names>
</name>
<name>
<surname><![CDATA[Antoniou]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2012</year>
<volume>27</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>324, e5-8</page-range></nlm-citation>
</ref>
<ref id="B83">
<label>83</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Svensson]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Mathiesen]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Reinholt]]></surname>
<given-names><![CDATA[FP]]></given-names>
</name>
<name>
<surname><![CDATA[Blomgren]]></surname>
<given-names><![CDATA[G:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty: A case report]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>1988</year>
<volume>70</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1238-42</page-range></nlm-citation>
</ref>
<ref id="B84">
<label>84</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Campbell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ebramzadeh]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Nelson]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Takamura]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[De Smet]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Amstutz]]></surname>
<given-names><![CDATA[HC:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Histological features of pseudotumor-like tissues from metal-on-metal hips]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2010</year>
<volume>468</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>2321-7</page-range></nlm-citation>
</ref>
<ref id="B85">
<label>85</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooper]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Della-Valle]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Tetreault]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Paprosky]]></surname>
<given-names><![CDATA[WG]]></given-names>
</name>
<name>
<surname><![CDATA[Sporer]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2012</year>
<volume>94</volume>
<numero>18</numero>
<issue>18</issue>
<page-range>1655-61</page-range></nlm-citation>
</ref>
<ref id="B86">
<label>86</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Urban]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Skipor]]></surname>
<given-names><![CDATA[AK]]></given-names>
</name>
<name>
<surname><![CDATA[Black]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jasty]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Local and distant products from modularity]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1995</year>
<volume>319</volume>
<page-range>94-105</page-range></nlm-citation>
</ref>
<ref id="B87">
<label>87</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collier]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Mayor]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[IR]]></given-names>
</name>
<name>
<surname><![CDATA[Surprenant]]></surname>
<given-names><![CDATA[VA]]></given-names>
</name>
<name>
<surname><![CDATA[Surprenant]]></surname>
<given-names><![CDATA[HP]]></given-names>
</name>
<name>
<surname><![CDATA[Currier]]></surname>
<given-names><![CDATA[BH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The tradeoffs associated with modular hip prostheses]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1995</year>
<volume>311</volume>
<page-range>91-101</page-range></nlm-citation>
</ref>
<ref id="B88">
<label>88</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Barrack]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Baffes]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
<name>
<surname><![CDATA[Clemow]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Serekian]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Wear and corrosion of modular interfaces in total hip replacements]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1994</year>
<volume>298</volume>
<page-range>80-8</page-range></nlm-citation>
</ref>
<ref id="B89">
<label>89</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collier]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Surprenant]]></surname>
<given-names><![CDATA[VA]]></given-names>
</name>
<name>
<surname><![CDATA[Jensen]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Mayor]]></surname>
<given-names><![CDATA[MB:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1991</year>
<volume>271</volume>
<page-range>305-12</page-range></nlm-citation>
</ref>
<ref id="B90">
<label>90</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kop]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Swarts]]></surname>
<given-names><![CDATA[E:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2009</year>
<volume>24</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1019-23</page-range></nlm-citation>
</ref>
<ref id="B91">
<label>91</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Buckley]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JJ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: The effect of crevice, stress, motion, and alloy coupling]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1993</year>
<volume>27</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1533-44</page-range></nlm-citation>
</ref>
<ref id="B92">
<label>92</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Buckley]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Bertin]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[Zernich]]></surname>
<given-names><![CDATA[MR:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems: A failure analysis of two implants]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>1994</year>
<volume>76</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>110-5</page-range></nlm-citation>
</ref>
<ref id="B93">
<label>93</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Bauer]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Paprosky]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Leurgans]]></surname>
<given-names><![CDATA[S:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A multicenter retrieval study of the taper interfaces of modular hip prostheses]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2002</year>
<volume>401</volume>
<numero>149-61</numero>
<issue>149-61</issue>
</nlm-citation>
</ref>
<ref id="B94">
<label>94</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro corrosion testing of modular hip tapers]]></article-title>
<source><![CDATA[J Biomed Mater Res B Appl Biomater]]></source>
<year>2003</year>
<volume>64</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>78-93</page-range></nlm-citation>
</ref>
<ref id="B95">
<label>95</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kawalec]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Payer]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Merritt]]></surname>
<given-names><![CDATA[K:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy]]></article-title>
<source><![CDATA[J Biomed Mater Res]]></source>
<year>1995</year>
<volume>29</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>867-73</page-range></nlm-citation>
</ref>
<ref id="B96">
<label>96</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kretzer]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Jakubowitz]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Krachler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Thomsen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Heisel]]></surname>
<given-names><![CDATA[C:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metal release and corrosion effects of modular neck total hip arthroplasty]]></article-title>
<source><![CDATA[Int Orthop]]></source>
<year>2009</year>
<volume>33</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1531-6</page-range></nlm-citation>
</ref>
<ref id="B97">
<label>97</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mroczkowski]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
<name>
<surname><![CDATA[Hertzler]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Humphrey]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Blanchard]]></surname>
<given-names><![CDATA[CR:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of impact assembly on the fretting corrosion of modular hip tapers]]></article-title>
<source><![CDATA[J Orthop Res]]></source>
<year>2006</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>271-9</page-range></nlm-citation>
</ref>
<ref id="B98">
<label>98</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collier]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Surprenant]]></surname>
<given-names><![CDATA[VA]]></given-names>
</name>
<name>
<surname><![CDATA[Jensen]]></surname>
<given-names><![CDATA[RE]]></given-names>
</name>
<name>
<surname><![CDATA[Mayor]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Surprenant]]></surname>
<given-names><![CDATA[HP:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion between the components of modular femoral hip prostheses]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1992</year>
<volume>74</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>511-7</page-range></nlm-citation>
</ref>
<ref id="B99">
<label>99</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bobyn]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
<name>
<surname><![CDATA[Tanzer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Krygier]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dujovne]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Brooks]]></surname>
<given-names><![CDATA[CE:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Concerns with modularity in total hip arthroplasty]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1994</year>
<volume>298</volume>
<page-range>27-36</page-range></nlm-citation>
</ref>
<ref id="B100">
<label>100</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Flemming]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Kawalec]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Placko]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Vassaux]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Merritt]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fretting corrosion accelerates crevice corrosion of modular hip tapers]]></article-title>
<source><![CDATA[J Appl Biomater]]></source>
<year>1995</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>19-26</page-range></nlm-citation>
</ref>
<ref id="B101">
<label>101</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Barrack]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Clemow]]></surname>
<given-names><![CDATA[AJ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion and wear at the modular interface of uncemented femoral stems]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1994</year>
<volume>76</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>68-72</page-range></nlm-citation>
</ref>
<ref id="B102">
<label>102</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lieberman]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Rimnac]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Garvin]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Klein]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[Salvati]]></surname>
<given-names><![CDATA[EA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An analysis of the head-neck taper interface in retrieved hip prostheses]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1994</year>
<volume>300</volume>
<page-range>162-7</page-range></nlm-citation>
</ref>
<ref id="B103">
<label>103</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mathiesen]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
<name>
<surname><![CDATA[Lindgren]]></surname>
<given-names><![CDATA[JU]]></given-names>
</name>
<name>
<surname><![CDATA[Blomgren]]></surname>
<given-names><![CDATA[GG]]></given-names>
</name>
<name>
<surname><![CDATA[Reinholt]]></surname>
<given-names><![CDATA[FP:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrosion of modular hip prostheses]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>1991</year>
<volume>73</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>569-75</page-range></nlm-citation>
</ref>
<ref id="B104">
<label>104</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Urban]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobs]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Galante]]></surname>
<given-names><![CDATA[JO:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Migration of corrosion products from modular hip prostheses: Particle microanalysis and histopathological findings]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>1994</year>
<volume>76</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1345-59</page-range></nlm-citation>
</ref>
<ref id="B105">
<label>105</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Skinner]]></surname>
<given-names><![CDATA[HB:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ceramic bearing surfaces: [Review] [50 refs]]]></article-title>
<source><![CDATA[Clin Orthopo Rel Res]]></source>
<year>1999</year>
<page-range>83</page-range></nlm-citation>
</ref>
<ref id="B106">
<label>106</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hannouche]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ceramics in total hip replacement [report]]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2005</year>
<volume>430</volume>
<page-range>62</page-range></nlm-citation>
</ref>
<ref id="B107">
<label>107</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamadouche]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Daussange]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bolander]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alumina on alumina total hip arthroplasty: a minimum 18.5-years follow-up study [Article]]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2002</year>
<volume>84</volume>
<page-range>69</page-range></nlm-citation>
</ref>
<ref id="B108">
<label>108</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bierbaum]]></surname>
<given-names><![CDATA[BE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ceramic on ceramic bearings in total hip arthroplasty]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>1999</year>
<page-range>83</page-range></nlm-citation>
</ref>
<ref id="B109">
<label>109</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yoo]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alumina on alumina total hip arthroplasty: a five years minimum follow-up study]]></article-title>
<source><![CDATA[J Bone and Joint Surg Am]]></source>
<year>2005</year>
<volume>87</volume>
<page-range>530</page-range></nlm-citation>
</ref>
<ref id="B110">
<label>110</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chevalier]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[What future for zirconia as a biomaterial?]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>2006</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>535-43</page-range></nlm-citation>
</ref>
<ref id="B111">
<label>111</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dalla-Pria]]></surname>
<given-names><![CDATA[P:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evolution and new application of the alumina ceramics in joint replacement]]></article-title>
<source><![CDATA[European Journal of Orthopaedic Surgery & Traumatology]]></source>
<year></year>
<volume>17</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>253-6</page-range></nlm-citation>
</ref>
<ref id="B112">
<label>112</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamilton]]></surname>
<given-names><![CDATA[WG]]></given-names>
</name>
<name>
<surname><![CDATA[McAuley]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Dennis]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Murphy]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Blumenfeld]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Politi]]></surname>
<given-names><![CDATA[J:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2010</year>
<volume>468</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>358-66</page-range></nlm-citation>
</ref>
<ref id="B113">
<label>113</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barrack]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Burak]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Skinner]]></surname>
<given-names><![CDATA[HB:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Concerns about ceramics in THA]]></article-title>
<source><![CDATA[Cl Orthop Rel Res]]></source>
<year>2004</year>
<volume>429</volume>
<page-range>73-9</page-range></nlm-citation>
</ref>
<ref id="B114">
<label>114</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Capello]]></surname>
<given-names><![CDATA[WN]]></given-names>
</name>
<name>
<surname><![CDATA[D'Antonio]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Manley]]></surname>
<given-names><![CDATA[MT:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alumina-on-alumina bearings in total hip arthroplasty: clinical results, osteolysis, breakage, and noise]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2007</year>
<volume>22</volume>
<page-range>311</page-range></nlm-citation>
</ref>
<ref id="B115">
<label>115</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Glaser]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Komistek]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Cates]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Mahfouz]]></surname>
<given-names><![CDATA[MR:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2008</year>
<volume>90</volume>
<numero>^s4</numero>
<issue>^s4</issue>
<supplement>4</supplement>
<page-range>112-20</page-range></nlm-citation>
</ref>
<ref id="B116">
<label>116</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosneck]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Klika]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Barsoum]]></surname>
<given-names><![CDATA[W:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A rare complication of ceramic-on-ceramic bearings in total hip arthoplasty]]></article-title>
<source><![CDATA[J Arthoplasty]]></source>
<year>2008</year>
<volume>23</volume>
<page-range>311</page-range></nlm-citation>
</ref>
<ref id="B117">
<label>117</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jarrett]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Ranawat]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bruzzone]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rodriguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ranawat]]></surname>
<given-names><![CDATA[C:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The squeaking hip: an underreported phenomenon of ceramic-on-ceramic total hip arthroplasty]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2007</year>
<volume>22</volume>
<page-range>302</page-range></nlm-citation>
</ref>
<ref id="B118">
<label>118</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Parvizi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Sharkey]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
<name>
<surname><![CDATA[Hozack]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Rothman]]></surname>
<given-names><![CDATA[RH:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The noisy ceramic hip: is component malpositioning the cause?]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2008</year>
<volume>23</volume>
<page-range>643-9</page-range></nlm-citation>
</ref>
<ref id="B119">
<label>119</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walter]]></surname>
<given-names><![CDATA[WL]]></given-names>
</name>
<name>
<surname><![CDATA[O'Toole]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
<name>
<surname><![CDATA[Walter]]></surname>
<given-names><![CDATA[WK]]></given-names>
</name>
<name>
<surname><![CDATA[Ellis]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zicat]]></surname>
<given-names><![CDATA[BA:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2007</year>
<volume>22</volume>
<page-range>496-503</page-range></nlm-citation>
</ref>
<ref id="B120">
<label>120</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chevillotte]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Trousdale]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Guyen]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[An]]></surname>
<given-names><![CDATA[KN:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The 2009 frank stinchfield award: "hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2010</year>
<volume>468</volume>
<page-range>345-50</page-range></nlm-citation>
</ref>
<ref id="B121">
<label>121</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Keurentjes]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Kuipers]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Wever]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Schreurs]]></surname>
<given-names><![CDATA[BW:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings]]></article-title>
<source><![CDATA[Clin Orthop Relat Res]]></source>
<year>2008</year>
<volume>466</volume>
<page-range>1438-43</page-range></nlm-citation>
</ref>
<ref id="B122">
<label>122</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Murphy]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
<name>
<surname><![CDATA[Ecker]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Tannast]]></surname>
<given-names><![CDATA[M:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Incidence of squeaking after alumina ceramic-ceramic total hip arthroplasty]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2008</year>
<volume>23</volume>
<page-range>327</page-range></nlm-citation>
</ref>
<ref id="B123">
<label>123</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Restrepo]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Post]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Kai]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Hozack]]></surname>
<given-names><![CDATA[WJ:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of stem design on the incidence of squeaking in ceramic on ceramic bearing total hip arthroplasty]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2010</year>
<volume>92</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>550-7</page-range></nlm-citation>
</ref>
<ref id="B124">
<label>124</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Walter]]></surname>
<given-names><![CDATA[WL]]></given-names>
</name>
<name>
<surname><![CDATA[Waters]]></surname>
<given-names><![CDATA[TS]]></given-names>
</name>
<name>
<surname><![CDATA[Gillies]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Donohoo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kurtz]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Ranawat]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Squeaking hips]]></article-title>
<source><![CDATA[J Bone Joint Surg Am]]></source>
<year>2008</year>
<volume>90</volume>
<numero>^s4</numero>
<issue>^s4</issue>
<supplement>4</supplement>
<page-range>102-11</page-range></nlm-citation>
</ref>
<ref id="B125">
<label>125</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Dickinson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Herb]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Creation of oxidized zirconium orthopaedic implants]]></article-title>
<source><![CDATA[J ATSM Int]]></source>
<year>2005</year>
<volume>2</volume>
<numero>7</numero>
<issue>7</issue>
</nlm-citation>
</ref>
<ref id="B126">
<label>126</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Long]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Riester]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[G:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nano-hardness measurements of oxidized Zr-2.5Nb and various orthopaedic materials]]></article-title>
<source><![CDATA[Trans Soc Biomaterials]]></source>
<year>1998</year>
<volume>21</volume>
<page-range>528</page-range></nlm-citation>
</ref>
<ref id="B127">
<label>127</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Good]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Ries]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Barrack]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reduced wear with oxidized zirconium femoral heads]]></article-title>
<source><![CDATA[J Bone Joint Surg]]></source>
<year>2003</year>
<volume>85</volume>
<numero>^s4</numero>
<issue>^s4</issue>
<supplement>4</supplement>
<page-range>105-10</page-range></nlm-citation>
</ref>
<ref id="B128">
<label>128</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nasser]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mott]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Wooley]]></surname>
<given-names><![CDATA[P:]]></given-names>
</name>
</person-group>
<source><![CDATA[A prospective comparison of ceramic and oxinium TKA components in metal hypersensitivity patients]]></source>
<year>2006</year>
<page-range>194</page-range><publisher-loc><![CDATA[San Diego^eCA CA]]></publisher-loc>
<publisher-name><![CDATA[Proceedings of the Annual Meeting of the American Academy of Orthopaedic Surgeons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B129">
<label>129</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kop]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Colin-Whitewood]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Johnston]]></surname>
<given-names><![CDATA[DJL:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Damage of Oxinium femoral heads subsequent to hip arthroplasty dislocation: three retrieval case studies]]></article-title>
<source><![CDATA[J Arthroplasty]]></source>
<year>2007</year>
<volume>22</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>775-9</page-range></nlm-citation>
</ref>
<ref id="B130">
<label>130</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Evangelista]]></surname>
<given-names><![CDATA[GT]]></given-names>
</name>
<name>
<surname><![CDATA[Fulkerson]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kummer]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Di Cesare]]></surname>
<given-names><![CDATA[PE:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surface damage to an Oxinium femoral head prosthesis after dislocation]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>2007</year>
<volume>89</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>535-7</page-range></nlm-citation>
</ref>
<ref id="B131">
<label>131</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCalden]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
<name>
<surname><![CDATA[Charron]]></surname>
<given-names><![CDATA[KD]]></given-names>
</name>
<name>
<surname><![CDATA[Davidson]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Teeter]]></surname>
<given-names><![CDATA[MG]]></given-names>
</name>
<name>
<surname><![CDATA[Holdsworth]]></surname>
<given-names><![CDATA[DW:]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Damage of an Oxinium femoral head and polyethylene liner following "routine" total hip replacement]]></article-title>
<source><![CDATA[J Bone Joint Surg Br]]></source>
<year>2011</year>
<volume>93</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>409-13</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
