<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2007-8196</journal-id>
<journal-title><![CDATA[Epistemus (Sonora)]]></journal-title>
<abbrev-journal-title><![CDATA[Epistemus (Sonora)]]></abbrev-journal-title>
<issn>2007-8196</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Sonora, División de Ingeniería]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2007-81962021000100053</article-id>
<article-id pub-id-type="doi">10.36790/epistemus.v15i30.164</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Temperatura corporal, termómetros y salud]]></article-title>
<article-title xml:lang="en"><![CDATA[Body temperature, thermometers and health]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castañeda]]></surname>
<given-names><![CDATA[Beatriz]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Soto-Puebla]]></surname>
<given-names><![CDATA[Diego]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Meza-Figueroa]]></surname>
<given-names><![CDATA[Diana]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Navarro-Espinoza]]></surname>
<given-names><![CDATA[Sofía]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pedroza-Montero]]></surname>
<given-names><![CDATA[Martín]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad de Sonora Departamento de Física ]]></institution>
<addr-line><![CDATA[Hermosillo ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad de Sonora Departamento de Investigación en Física ]]></institution>
<addr-line><![CDATA[Hermosillo ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad de Sonora Departamento de Geología ]]></institution>
<addr-line><![CDATA[Hermosillo ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Universidad de Sonora Departamento de Física ]]></institution>
<addr-line><![CDATA[Hermosillo ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af5">
<institution><![CDATA[,Universidad de Sonora Departamento de Investigación en Física ]]></institution>
<addr-line><![CDATA[Hermosillo ]]></addr-line>
<country>Mexico</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2021</year>
</pub-date>
<volume>15</volume>
<numero>30</numero>
<fpage>53</fpage>
<lpage>57</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S2007-81962021000100053&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S2007-81962021000100053&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S2007-81962021000100053&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen La medición de la temperatura ha sido desde siempre uno los retos de la medicina, puesto que muchas enfermedades tienen como signo inicial el aumento o la disminución de la temperatura, ya sea a cuerpo completo o en regiones muy bien localizadas. Tales afecciones comprenden infecciones, desórdenes metabólicos, cardiovasculares, inflamaciones y cáncer, por lo que la facilidad de uso y precisión de los termómetros para medir rápidamente la temperatura es crucial. Desafortunadamente su desarrollo tecnológico ha sido muy lento, pero en las últimas tres décadas se han incorporado tecnologías que permiten obtener lecturas sin contacto con una gran exactitud, aunque aún resta el desarrollo de herramientas computacionales para entender la expresión térmica de procesos patológicos.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Temperature measurement has always been one of the challenges of medicine since many diseases have as their initial sign an increase or decrease in temperature, either in the whole body or in very localized regions. Such conditions include infections, metabolic disorders, cardiovascular disorders, inflammation, and cancer. Thus, the ease of use and accuracy of thermometers for rapid temperature measurement is crucial. Unfortunately, their technological development has been slow. However, in the last three decades, they have incorporated technologies that allow obtaining non-contact readings with high accuracy, although the development of computational tools to understand the thermal expression of pathological processes is still pending.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Temperatura]]></kwd>
<kwd lng="es"><![CDATA[termómetro]]></kwd>
<kwd lng="es"><![CDATA[Infrarrojo]]></kwd>
<kwd lng="es"><![CDATA[cáncer]]></kwd>
<kwd lng="en"><![CDATA[Temperature]]></kwd>
<kwd lng="en"><![CDATA[thermometer]]></kwd>
<kwd lng="en"><![CDATA[infrared]]></kwd>
<kwd lng="en"><![CDATA[cancer]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>[1]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Clayman]]></surname>
<given-names><![CDATA[C. B.]]></given-names>
</name>
</person-group>
<source><![CDATA[The American Medical Association Encyclopedia of Medicine]]></source>
<year>1989</year>
</nlm-citation>
</ref>
<ref id="B2">
<label>[2]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Popson]]></surname>
<given-names><![CDATA[M. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Dimri]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Borger]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Biochemistry, Heat and Calories]]></source>
<year>2019</year>
<publisher-name><![CDATA[StatPearls Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>[3]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brain]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[How do A delta and C fibers differ in sending pain information to the brain?]]></source>
<year>2019</year>
</nlm-citation>
</ref>
<ref id="B4">
<label>[4]</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eliav]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Gracely]]></surname>
<given-names><![CDATA[R. H.]]></given-names>
</name>
</person-group>
<source><![CDATA[Orofacial Pain and Headache: Chapter 3 Measuring and assessing pain]]></source>
<year>2008</year>
<page-range>45-56</page-range><publisher-name><![CDATA[Mosby Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>[5]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wright]]></surname>
<given-names><![CDATA[W. F.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Early evolution of the thermometer and application to clinical medicine]]></article-title>
<source><![CDATA[J. Therm. Biol.]]></source>
<year>2016</year>
<volume>56</volume>
<page-range>18-30</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>[6]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[1611, Santorio inventa el termómetro clínico]]></source>
<year>2018</year>
</nlm-citation>
</ref>
<ref id="B7">
<label>[7]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ashworth]]></surname>
<given-names><![CDATA[W. B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Scientist of the Day - Daniel Fahrenheit]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B8">
<label>[8]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[O'hara]]></surname>
<given-names><![CDATA[G. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Phillips]]></surname>
<given-names><![CDATA[D. B.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Method and apparatus for measuring internal body temperature utilizing infrared emissions]]></article-title>
<source><![CDATA[U.S. Patent No. 4,602,642]]></source>
<year>1986</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>[9]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[T. H.]]></surname>
<given-names><![CDATA[Benzinger T. H.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical ear thermometer]]></article-title>
<source><![CDATA[U.S. Patent No. 3,156,117]]></source>
<year>1964</year>
</nlm-citation>
</ref>
<ref id="B10">
<label>[10]</label><nlm-citation citation-type="">
<source><![CDATA[Thermometer]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B11">
<label>[11]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nave]]></surname>
<given-names><![CDATA[C. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Olmo]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Termómetro de oído por Infrarrojos]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B12">
<label>[12]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[C. G.]]></surname>
<given-names><![CDATA[Teran]]></given-names>
</name>
<name>
<surname><![CDATA[J.]]></surname>
<given-names><![CDATA[Torrez&#8208;Llanos]]></given-names>
</name>
<name>
<surname><![CDATA[T. E.]]></surname>
<given-names><![CDATA[Teran&#8208;Miranda]]></given-names>
</name>
<name>
<surname><![CDATA[C.]]></surname>
<given-names><![CDATA[Balderrama]]></given-names>
</name>
<name>
<surname><![CDATA[N. S.]]></surname>
<given-names><![CDATA[Shah]]></given-names>
</name>
<name>
<surname><![CDATA[Villarroel]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Clinical accuracy of a non&#8208;contact infrared skin thermometer in paediatric practice]]></article-title>
<source><![CDATA[Child: care, health dev]]></source>
<year>2012</year>
<volume>38</volume>
<page-range>471-6</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>[13]</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Driscoll]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[The History of the Medical Thermometer]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B14">
<label>[14]</label><nlm-citation citation-type="">
<collab>U.S. Food &amp; Drug Administration</collab>
<source><![CDATA[Non-contact Infrared Thermometers]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B15">
<label>[15]</label><nlm-citation citation-type="">
<collab>U.S. Food &amp; Drug Administration</collab>
<source><![CDATA[Detección de cáncer de mama: el termograma no sustituye a la mamografía]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B16">
<label>[16]</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guerrero-Robles]]></surname>
<given-names><![CDATA[C. I.]]></given-names>
</name>
<name>
<surname><![CDATA[Lozano-Trenado]]></surname>
<given-names><![CDATA[L. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Uscanga-Carmona]]></surname>
<given-names><![CDATA[M. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ramírez-Vilchis]]></surname>
<given-names><![CDATA[A. N.]]></given-names>
</name>
<name>
<surname><![CDATA[Silva-Escobedo]]></surname>
<given-names><![CDATA[J. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez-Monroy]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[C. A.]]></surname>
<given-names><![CDATA[Gonzalez-Diaz C. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluación de termografía tisular diferenciada en mama como potencial técnico para asistir la detección de cáncer]]></article-title>
<source><![CDATA[RMIB]]></source>
<year>2015</year>
<volume>36</volume>
<page-range>65-75</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
