<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2007-6835</journal-id>
<journal-title><![CDATA[Revista ALCONPAT]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. ALCONPAT]]></abbrev-journal-title>
<issn>2007-6835</issn>
<publisher>
<publisher-name><![CDATA[Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción A.C.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2007-68352022000100010</article-id>
<article-id pub-id-type="doi">10.21041/ra.v12i1.567</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Thermographic study of the pathological manifestations due to humidity and of the conservation state of the Santa Maria Basilica&#8217;s roof]]></article-title>
<article-title xml:lang="pt"><![CDATA[Estudo termográfico das manifestações patológicas devidas à umidade e do estado de conservação da cobertura da Basílica de Santa Maria]]></article-title>
<article-title xml:lang="es"><![CDATA[Estudio termográfico de las manifestaciones patológicas por humedades y del estado de conservación de la cubierta de la Basílica de Santa María]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bru]]></surname>
<given-names><![CDATA[David]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ivorra]]></surname>
<given-names><![CDATA[Salvador]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad de Alicante Departamento de Ingeniería Civil ]]></institution>
<addr-line><![CDATA[ Alicante]]></addr-line>
<country>Spain</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2022</year>
</pub-date>
<volume>12</volume>
<numero>1</numero>
<fpage>110</fpage>
<lpage>126</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S2007-68352022000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S2007-68352022000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S2007-68352022000100010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract This paper analyzes the current state of the roof of the Basilica of Santa Maria, Alicante, Spain. This building dates back to the 13th century and is catalogued. For the analysis of the efflorescence observed, an analysis of the constructive typology is carried out, as well as a visual analysis of the state of the same, describing the existing pathological manifestations, both in the exterior area of the roofs, as well as in the interior area of the rooms under them. For the technical analysis of the possible leaks from the roof to the interior rooms of the basilica, a watertightness test and the verification through the control of the variation of temperatures by means of thermographic analysis are carried out. It can be concluded the existence and position of leaks that have damaged this listed building.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Resumo Este trabalho analisa o estado atual da cobertura da Basílica de Santa María, Alicante, Espanha. Este edifício data do século XIII e está catalogado. Para a análise das eflorescências observadas foi efetuada uma análise da tipologia da construção, bem como uma análise visual do estado dela, descrevendo as manifestações patológicas existentes, tanto na zona exterior das coberturas, como na área interna dos ambientes abaixo dela. Para a análise técnica de possíveis vazamentos através da cobertura para os ambientes interiores da basílica, foi efetuado um ensaio de estanqueidade e verificação através do controle da variação de temperatura por meio de análise termográfica. O procedimento foi adequado para entender e comprovar a existência e localização de vazamentos que danificaram este edifício.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen El presente trabajo analiza el estado actual de la cubierta de la Basílica de Santa María, Alicante, España. Este edificio data del siglo XIII y está catalogado. Para el análisis de las eflorescencias que se observan se realiza un análisis de la tipología constructiva, así como un análisis visual del estado de las mismas, describiendo las manifestaciones patológicas existentes, tanto en la zona exterior de las cubiertas, como en la zona interior de las salas bajo las mismas. Para el análisis técnico de las posibles filtraciones de la cubierta a las salas interiores de la basílica se realiza una prueba de estanquidad y la verificación a través del control de la variación de temperaturas mediante análisis termográfico. Se puede concluir la existencia y posición de filtraciones que han dañado este edificio catalogado.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[thermography]]></kwd>
<kwd lng="en"><![CDATA[humidities]]></kwd>
<kwd lng="en"><![CDATA[filtrations]]></kwd>
<kwd lng="en"><![CDATA[efflorescence]]></kwd>
<kwd lng="en"><![CDATA[historical building]]></kwd>
<kwd lng="pt"><![CDATA[termografia]]></kwd>
<kwd lng="pt"><![CDATA[umidade]]></kwd>
<kwd lng="pt"><![CDATA[infiltração]]></kwd>
<kwd lng="pt"><![CDATA[eflorescência]]></kwd>
<kwd lng="pt"><![CDATA[edifício histórico]]></kwd>
<kwd lng="es"><![CDATA[termografía]]></kwd>
<kwd lng="es"><![CDATA[humedades]]></kwd>
<kwd lng="es"><![CDATA[filtraciones]]></kwd>
<kwd lng="es"><![CDATA[eflorescencias]]></kwd>
<kwd lng="es"><![CDATA[edificio histórico]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[M.T.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Rosse]]></surname>
<given-names><![CDATA[V. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Laurindo]]></surname>
<given-names><![CDATA[N. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Thermography evaluation strategy proposal due moisture damage on building facades&#8221;]]></article-title>
<source><![CDATA[Journal of Building Engineering]]></source>
<year>2021</year>
<volume>43</volume>
<numero>102555</numero>
<issue>102555</issue>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barreira]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[R.M.S.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Simões]]></surname>
<given-names><![CDATA[M.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Rebelo]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Quantitative infrared thermography to evaluate the humidification of lightweight concrete&#8221;]]></article-title>
<source><![CDATA[Sensors (Switzerland)]]></source>
<year>2020</year>
<volume>20</volume>
<numero>6</numero>
<issue>6</issue>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barreira]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[R.M.S.F.]]></given-names>
</name>
<name>
<surname><![CDATA[Simões]]></surname>
<given-names><![CDATA[M.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Emissivity of building materials for infrared measurements&#8221;]]></article-title>
<source><![CDATA[Sensors]]></source>
<year>2021</year>
<volume>21</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1-13</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bevià García]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Azuar Ruiz]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Santa María descubierta: Arqueología, arquitectura-cerámica: Excavaciones en la Iglesia de Santa María de Alicante (1997-1998)&#8221;]]></article-title>
<source><![CDATA[Alicante]]></source>
<year>2005</year>
<publisher-name><![CDATA[Fundación MARQ]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brotóns]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Tomás]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Ivorra]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Alarcón]]></surname>
<given-names><![CDATA[J.C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Temperature influence on the physical and mechanical properties of a porous rock: San Julian's calcarenite]]></article-title>
<source><![CDATA[Engineering Geology]]></source>
<year>2013</year>
<volume>167</volume>
<page-range>117-27</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Giovannacci]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Brissaud]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Mertz]]></surname>
<given-names><![CDATA[J.-D.]]></given-names>
</name>
<name>
<surname><![CDATA[Mouhoubi]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Bodnar]]></surname>
<given-names><![CDATA[J.-L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Nonintrusive tools to detect salts contamination in masonry: Case study of Fontaine-Chaalis church&#8221;]]></article-title>
<source><![CDATA[roceedings of SPIE - The International Society for Optical Engineering]]></source>
<year>2017</year>
<numero>10331</numero>
<issue>10331</issue>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grossi]]></surname>
<given-names><![CDATA[C. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Esbert]]></surname>
<given-names><![CDATA[R. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Las sales solubles en el deterioro de rocas monumentales. Revisión bibliográfica&#8221;]]></article-title>
<source><![CDATA[Materiales de Construcción]]></source>
<year>1994</year>
<volume>44</volume>
<numero>235</numero>
<issue>235</issue>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Louis]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[García del Cura]]></surname>
<given-names><![CDATA[M. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Spairani]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[de Blas]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;The Civil Palaces in Gravina Street, Alicante: building stones and salt weathering]]></article-title>
<source><![CDATA[Materiales de Construcción]]></source>
<year>2001</year>
<volume>51</volume>
<numero>262</numero>
<issue>262</issue>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lucchi]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Applications of the infrared thermography in the energy audit of buildings: A review&#8221;]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2018</year>
<volume>82</volume>
<page-range>3077-90</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Paricio Ansuateguie]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<source><![CDATA[&#8220;La construcción de la Arquitectura. Institut de Tecnologia de la Construcció de Catalunya&#8221;]]></source>
<year>1985</year>
<edition>2</edition>
<page-range>26</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="book">
<source><![CDATA[Norma Básica de la Edificación. Cubiertas con materiales bituminosos: &#8220;NBE QB-90&#8221;]]></source>
<year></year>
<publisher-name><![CDATA[Gobierno de España]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruiz Valero]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Flores Sasso]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Prieto Vicioso]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;In situ assessment of superficial moisture condition in façades of historic building using non-destructive techniques&#8221;]]></article-title>
<source><![CDATA[Case Studies in Construction Materials]]></source>
<year>2019</year>
<volume>10</volume>
<numero>e00228</numero>
<issue>e00228</issue>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[G. P.]]></given-names>
</name>
<name>
<surname><![CDATA[Batista]]></surname>
<given-names><![CDATA[P. I. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Povóas]]></surname>
<given-names><![CDATA[Y. V.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Uso de termografía infrarroja para estudiar el desempeño térmico de paredes: una revisión bibliográfica&#8221;]]></article-title>
<source><![CDATA[Revista ALCONPAT]]></source>
<year>2019</year>
<volume>9</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>117-1129</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Takeda]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Mazer]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Potencial da análise termográfica para avaliar manifestações patológicas em sistemas de revestimentos de fachadas&#8221;]]></article-title>
<source><![CDATA[Revista ALCONPAT]]></source>
<year>2018</year>
<volume>8</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>38-50</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valluzzi]]></surname>
<given-names><![CDATA[M.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Lorenzoni]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Deiana]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Taffarel]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Modena]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Non-destructive investigations for structural qualification of the Sarno Baths, Pompeii&#8221;]]></article-title>
<source><![CDATA[Journal of Cultural Heritage]]></source>
<year>2019</year>
<volume>40</volume>
<page-range>280-7</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vijay]]></surname>
<given-names><![CDATA[P.V.]]></given-names>
</name>
<name>
<surname><![CDATA[Tulasi Gadde]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Gangarao]]></surname>
<given-names><![CDATA[H.V.S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Structural Evaluation and Rehabilitation of Century-Old Masonry and Timber Buildings&#8221;]]></article-title>
<source><![CDATA[Journal of Architectural Engineering]]></source>
<year>2019</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garrido]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Solla]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Lagüela]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Irt and gpr techniques for moisture detection and characterisation in buildings&#8221;]]></article-title>
<source><![CDATA[Sensors (Switzerland)]]></source>
<year>2020</year>
<volume>20</volume>
<numero>22</numero>
<issue>22</issue>
<page-range>1-38</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez-Garrido]]></surname>
<given-names><![CDATA[M.I.]]></given-names>
</name>
<name>
<surname><![CDATA[Fort]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez-Heras]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Valles-Iriso]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Varas-Muriel]]></surname>
<given-names><![CDATA[M.J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;A comprehensive study for moisture control in cultural heritage using non-destructive techniques&#8221;]]></article-title>
<source><![CDATA[Journal of Applied Geophysics]]></source>
<year>2018</year>
<volume>155</volume>
<page-range>36-52</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Tao]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Quantitative description theory of water migration in rock sites based on infrared radiation temperature&#8221;]]></article-title>
<source><![CDATA[Engineering Geology]]></source>
<year>2018</year>
<volume>241</volume>
<page-range>64-75</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thomas]]></surname>
<given-names><![CDATA[c.]]></given-names>
</name>
<name>
<surname><![CDATA[Lombillo]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Setién]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Polanco]]></surname>
<given-names><![CDATA[J. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Villegas]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[&#8220;Absorción por capilaridad y consolidación de materiales pétreos del patrimonio histórico construido impermeabilizados y reforzados con productos hidrofugantes y consolidantes comerciales&#8221;]]></article-title>
<source><![CDATA[Tecnología de la rehabilitación y la gestión del patrimonio construido (REHABEND)]]></source>
<year>2008</year>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="book">
<collab>UNE EN 13187</collab>
<source><![CDATA[&#8220;Prestaciones térmicas de edificios. Detección cualitativa de irregularidades en cerramientos de edificios. Método de infrarrojos&#8221;]]></source>
<year>1998</year>
<publisher-name><![CDATA[Asociación Española de Normalización]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>