<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-199X</journal-id>
<journal-title><![CDATA[Revista odontológica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Odont. Mex]]></abbrev-journal-title>
<issn>1870-199X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Facultad de Odontología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-199X2021000200154</article-id>
<article-id pub-id-type="doi">10.22201/fo.1870199xp.2021.25.2.82691</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Disinfection of dental impression materials and its effects on dimensional changes: a literature review]]></article-title>
<article-title xml:lang="es"><![CDATA[Desinfección de los materiales de impresión dental y sus efectos en los cambios dimensionales: una revisión de la literatura]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Dapello-Zevallos]]></surname>
<given-names><![CDATA[Giannina Milagros]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[San Miguel-Ramírez]]></surname>
<given-names><![CDATA[Kimberly Nieves Mishell]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Febre-Cuibin]]></surname>
<given-names><![CDATA[Kelvin Samuel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gutiérrez-Obando]]></surname>
<given-names><![CDATA[Deysi Albertina]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Tinedo-López]]></surname>
<given-names><![CDATA[Pedro Luis]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Privada San Juan Bautista Escuela de Estomatología ]]></institution>
<addr-line><![CDATA[Lima ]]></addr-line>
<country>Peru</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad Privada San Juan Bautista Escuela de Estomatología ]]></institution>
<addr-line><![CDATA[Lima ]]></addr-line>
<country>Peru</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad Privada San Juan Bautista Escuela de Estomatología ]]></institution>
<addr-line><![CDATA[Lima ]]></addr-line>
<country>Peru</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2021</year>
</pub-date>
<volume>25</volume>
<numero>2</numero>
<fpage>154</fpage>
<lpage>159</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-199X2021000200154&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-199X2021000200154&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-199X2021000200154&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT A disinfectant must meet two fundamental requirements: be an effective antimicrobial agent and preserve the dimensional stability and surface details of the impression. This allows to obtain much more accurate plaster models that allow the fabrication of prostheses. The most recommended procedures are immersion and spraying, using disinfectant solutions such as sodium hypochlorite, glutaraldehyde, iodophors and phenols at different concentrations. The available impression materials were not originally formulated to disinfect, so there is the potential for disinfection procedures to alter the physical features of the impressions and consequently the characteristics of the plater model. That is why the aim of this updated review is to know the effect of disinfectants on the dimensional stability of different impression materials after being subjected bto different disinfection methods.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Un desinfectante debe cumplir dos requisitos fundamentales: ser un agente antimicrobiano eficaz y preservar la estabilidad dimensional y los detalles de la superficie de la impresión. Esto permite obtener modelos de yeso mucho más precisos que permiten la fabricación de prótesis. Los procedimientos más recomendados son la inmersión y la pulverización, utilizando soluciones desinfectantes como el hipoclorito de sodio, el glutaraldehído, los yodóforos y los fenoles a diferentes concentraciones. Los materiales de impresión disponibles no fueron formulados originalmente para desinfectar, por lo que existe la posibilidad de que los procedimientos de desinfección alteren las características físicas de las impresiones y, en consecuencia, las características del modelo de placa. Por ello, el objetivo de esta revisión actualizada es conocer el efecto de los desinfectantes sobre la estabilidad dimensional de diferentes materiales de impresión tras ser sometidos a distintos métodos de desinfección.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Disinfection]]></kwd>
<kwd lng="en"><![CDATA[impressions]]></kwd>
<kwd lng="en"><![CDATA[dimensional stability]]></kwd>
<kwd lng="es"><![CDATA[Desinfección]]></kwd>
<kwd lng="es"><![CDATA[impresiones]]></kwd>
<kwd lng="es"><![CDATA[estabilidad dimensional]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Marinheiro]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Rebelo]]></surname>
<given-names><![CDATA[SC]]></given-names>
</name>
<name>
<surname><![CDATA[Soares]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Figueiralce]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Maia]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comportamentos na desinfecao das impressöes dentárias por médicos dentistas e técnicos de prótese de Viseu]]></article-title>
<source><![CDATA[Rev Port Estomatol Med Dent Cir Maxilofac]]></source>
<year>2014</year>
<volume>55</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>232-7</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guiraldo]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Borsato]]></surname>
<given-names><![CDATA[TT]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Gonini Jr]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sinhoreti]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface detail reproduction and dimensional accuracy of stone models: influence of disinfectant solutions and alginate impression materials]]></article-title>
<source><![CDATA[Braz Dent J]]></source>
<year>2012</year>
<volume>23</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>417-21</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Samra]]></surname>
<given-names><![CDATA[RK]]></given-names>
</name>
<name>
<surname><![CDATA[Bhide]]></surname>
<given-names><![CDATA[SV]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber]]></article-title>
<source><![CDATA[Saudi Dent J]]></source>
<year>2018</year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>125-41</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chidambaranathan]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Balasubramanium]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comprehensive review and comparison of the disinfection techniques currently available in the literature]]></article-title>
<source><![CDATA[J Prosthodont]]></source>
<year>2019</year>
<volume>28</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>e849-56</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soganci]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cinar]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Caglar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yagiz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[3D evaluation of the effect of disinfectants on dimensional accuracy and stability of two elastomeric impression materials]]></article-title>
<source><![CDATA[Dent Mater J]]></source>
<year>2018</year>
<volume>37</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>675-84</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Estafanous]]></surname>
<given-names><![CDATA[EW]]></given-names>
</name>
<name>
<surname><![CDATA[Palenik]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Platt]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Disinfection of bacterially contaminated hydrophilic PVS impression materials]]></article-title>
<source><![CDATA[J Prosthodont]]></source>
<year>2012</year>
<volume>21</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>16-21</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amin]]></surname>
<given-names><![CDATA[WM]]></given-names>
</name>
<name>
<surname><![CDATA[Al-Ali]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[Al Tarawneh]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Taha]]></surname>
<given-names><![CDATA[ST]]></given-names>
</name>
<name>
<surname><![CDATA[Saleh]]></surname>
<given-names><![CDATA[MW]]></given-names>
</name>
<name>
<surname><![CDATA[Ereifij]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts]]></article-title>
<source><![CDATA[J Clin Med Res]]></source>
<year>2009</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>81-9</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Azevedo]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Correia]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Portela]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sampaio-Maia]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A simple and effective method for addition silicone impression disinfection]]></article-title>
<source><![CDATA[J Adv Prosthodont]]></source>
<year>2019</year>
<volume>11</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>155-61</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pal]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
<name>
<surname><![CDATA[Kamble]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Chaurasia]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Chaurasia]]></surname>
<given-names><![CDATA[VR]]></given-names>
</name>
<name>
<surname><![CDATA[Tiwari]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bansal]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of different disinfactants on dimensional accuracy and surface quality of type IV gypsum casts retrieved from elastomeric impression materials]]></article-title>
<source><![CDATA[J Int Oral Health]]></source>
<year>2014</year>
<volume>6</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>77-81</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ismail]]></surname>
<given-names><![CDATA[HA]]></given-names>
</name>
<name>
<surname><![CDATA[Mahross]]></surname>
<given-names><![CDATA[HZ]]></given-names>
</name>
<name>
<surname><![CDATA[Shikho]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of dimensional accuracy for different complete edentulous impressions immersed in different disinfectant solutions]]></article-title>
<source><![CDATA[Eur J Dent]]></source>
<year>2017</year>
<volume>11</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>242-9</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guiraldo]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Berger]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
<name>
<surname><![CDATA[Sigueira]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Grandi]]></surname>
<given-names><![CDATA[VH]]></given-names>
</name>
<name>
<surname><![CDATA[Lopes]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Gonini-Júnior]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface detail reproduction and dimensional accuracy of molds: influence of disinfectant solutions and elastomeric impression materials]]></article-title>
<source><![CDATA[Acta Odontol Latinoam]]></source>
<year>2017</year>
<volume>30</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>13-8</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thota]]></surname>
<given-names><![CDATA[KK]]></given-names>
</name>
<name>
<surname><![CDATA[Jasthi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ravuri]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Tella]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study]]></article-title>
<source><![CDATA[J Clin Diagn Res]]></source>
<year>2014</year>
<volume>8</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>48-50</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rentzia]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Coleman]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[O'Donnell]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dowling]]></surname>
<given-names><![CDATA[AH]]></given-names>
</name>
<name>
<surname><![CDATA[O'Sullivan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Disinfection procedures: Their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2011</year>
<volume>39</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>133-40</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goel]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Solanki]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Nayak]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A comparative study between microwave irradiation and sodium hypochlorite chemical disinfection: a prosthodontic view]]></article-title>
<source><![CDATA[J Clin Diagn Res]]></source>
<year>2014</year>
<volume>8</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>42-6</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hidalgo]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Balarezo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Estudio in vitro de la alteración dimensional de impresiones con silicona por adición sometidas a desinfección]]></article-title>
<source><![CDATA[Rev Estomatol Herediana]]></source>
<year>2004</year>
<volume>14</volume>
<numero>2-1</numero>
<issue>2-1</issue>
<page-range>45-50</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bustos]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Martínez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Catalán]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of inmersion desinfection with 0.5% sodium hypochlorite and 2% glutaraldehyde on alginate and silicone: microbiology and SEM study]]></article-title>
<source><![CDATA[Int J Odontostomat]]></source>
<year>2010</year>
<volume>4</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>169-77</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ahila]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Subramaniam]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative evaluation of dimensional stability and surface quality of gypsum casts retrieved from disinfected addition silicone impressions at various time intervals: an in vitro study]]></article-title>
<source><![CDATA[J Dent Oral Hyg]]></source>
<year>2012</year>
<volume>4</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>34-43</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Melilli]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Rallo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cassaro]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pizzo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials]]></article-title>
<source><![CDATA[J Oral Sci]]></source>
<year>2008</year>
<volume>50</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>441-6</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[AlZain]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of 0.5% glutaraldehyde disinfection on surface wettability of elastomeric impression materials]]></article-title>
<source><![CDATA[Saudi Dent J]]></source>
<year>2019</year>
<volume>31</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>122-8</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Almortadi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Chadwick]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Disinfection of dental impressions - compliance to accepted standards]]></article-title>
<source><![CDATA[Br Dent J]]></source>
<year>2010</year>
<volume>209</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>607-11</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kotsiomiti]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Tzialla]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hatjivasiliou]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Accuracy and stability of impression materials subjected to chemical disinfection - a literature review]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2008</year>
<volume>35</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>291-9</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nassar]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Ava]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface detail reproduction and effect of disinfectant and long-term storage on the dimensional stability of a novel vinyl polyether silicone impression material]]></article-title>
<source><![CDATA[J Prosthodont]]></source>
<year>2015</year>
<volume>24</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>494-8</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nimonkar]]></surname>
<given-names><![CDATA[SV]]></given-names>
</name>
<name>
<surname><![CDATA[Belkhode]]></surname>
<given-names><![CDATA[VM]]></given-names>
</name>
<name>
<surname><![CDATA[Godbole]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
<name>
<surname><![CDATA[Nimonkar]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
<name>
<surname><![CDATA[Dahane]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Sathe]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative evaluation of the effect of chemical disinfectants and ultraviolet disinfection on dimensional stability of the polyvinyl siloxane impressions]]></article-title>
<source><![CDATA[J Int Soc Prev Community Dent]]></source>
<year>2019</year>
<volume>9</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>152-8</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Demajo]]></surname>
<given-names><![CDATA[JK]]></given-names>
</name>
<name>
<surname><![CDATA[Cassar]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Farrugia]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Millan-Sango]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Sammut]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Valdramidis]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effectiveness of disinfectants on antimicrobial and physical properties of dental impression materials]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2016</year>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>63-7</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Asopa]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Padiyar]]></surname>
<given-names><![CDATA[UN]]></given-names>
</name>
<name>
<surname><![CDATA[Verma]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Suri]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Somayaji]]></surname>
<given-names><![CDATA[NS]]></given-names>
</name>
<name>
<surname><![CDATA[Radhakrishnan]]></surname>
<given-names><![CDATA[IC]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study]]></article-title>
<source><![CDATA[J Family Med Prim Care]]></source>
<year>2020</year>
<volume>9</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1348-534</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ulgey]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gorler]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Yesilyurt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Importance of disinfection time and procedure with different alginate impression products to reduce dimensional instability]]></article-title>
<source><![CDATA[Niger J Clin Pract]]></source>
<year>2020</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>284-90</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[AlZain]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: a systematic review and meta-analysis study]]></article-title>
<source><![CDATA[Saudi Dent J]]></source>
<year>2020</year>
<volume>32</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>161-70</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
