<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-199X</journal-id>
<journal-title><![CDATA[Revista odontológica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Odont. Mex]]></abbrev-journal-title>
<issn>1870-199X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Facultad de Odontología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-199X2015000400240</article-id>
<article-id pub-id-type="doi">10.1016/j.rodmex.2015.10.005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Comparación de la precisión marginal de cofias de zirconia entre los sistemas CAD/CAM Cerec InLab (Sirona ® ), CAD/CAM Zirkonzahn (Zirkonzahn ® ) y sistema pantográfico Zirkograph 025 ECO (Zirkonzahn ® )]]></article-title>
<article-title xml:lang="en"><![CDATA[Comparison of marginal fit of zirconia copings manufactured with the use of two CAD/CAM systems Cerec InLab (Sirona ® ) CAD/CAM Zirkonzahn (Zirkonzahn ® ) and Zirkograph 025 ECO pantographic system (manual milling system) (Zirkonzahn ® )]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Jiménez Suárez]]></surname>
<given-names><![CDATA[María José]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sandoval Vernimmen]]></surname>
<given-names><![CDATA[Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Merchán]]></surname>
<given-names><![CDATA[Estefanía Alexandra]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad San Francisco de Quito Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad San Francisco de Quito Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad San Francisco de Quito Facultad de Odontología ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2015</year>
</pub-date>
<volume>19</volume>
<numero>4</numero>
<fpage>240</fpage>
<lpage>245</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-199X2015000400240&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-199X2015000400240&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-199X2015000400240&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[ Objetivo: Comparar la precisión marginal de cofias de zirconia elaboradas empleando dos sistemas CAD/CAM Cerec InLab (Sirona®) y Zirkonzahn (Zirkonzahn®) y un sistema pantográfi co Zirkograph 025 ECO (Zirkonzahn®).  Material y métodos:  Se elaboró un muñón maestro de Cr-Co con preparación para corona de zirconia de un premolar superior. Se fabricaron 10 cofias de zirconia por grupo siguiendo los parámetros de cada sistema. El grupo control consistió en 10 cofias metálicas. Se ejecutó una técnica de réplica, utilizando polivinilsiloxano elite HD+ (Zhermack®). Mediante observación estereomicroscópica con aumento de 50x, se determinó en micras la discrepancia marginal absoluta y el espesor marginal de un punto por cara de cada cofia. El análisis estadístico se ejecutó con el software IBM SPSS®. Para comparar los datos obtenidos se realizó el test t.  Resultados:  La discrepancia marginal absoluta media y el espesor marginal fue 92.14 ± 38.59 y 78.62 ± 31.33 &#956;m para el sistema CAD/CAM Cerec InLab (Sirona®), 38.71 ± 12.62 y 36.91 ± 13.56 &#956;m para el sistema CAD/CAM Zirkonzahn (Zirkonzahn®), 77.92 ± 38.01 y 69.42 ± 33.23 &#956;m para el sistema pantográfico Zirkograph 025 ECO (Zirkonzahn®) y 44.11 ± 15.36 y 43.74 ± 15.70 &#956;m para el grupo control. Existieron diferencias estadísticamente significativas entre los sistemas Cerec InLab (Sirona®) y Zirkograph 025 ECO (Zirkonzahn®) en comparación con el grupo control para la discrepancia marginal absoluta y el espesor marginal. No existieron diferencias estadísticamente significativas entre los sistemas CAD/CAM Zirkonzahn (Zirkonzahn®) y el grupo control. El nivel de significancia fue p &gt; 0.001.  Conclusiones: El sistema más preciso fue CAD/CAM Zirkonzahn (Zirkonzahn®). El sistema que mostró menor precisión marginal fue Cerec InLab (Sirona®).]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ Objective: To compare marginal fit of zirconia copings manufactured following two different systems: CAD/CAM Cerec InLab (Sirona®) and Zirkonzahn (Zirkonzahn®) as well as a Zirkograph 025 ECO (Zirkonzahn®) pantograph system.  Material and methods:  A master Cr-Co model stump was manufactured; it was prepared for the zirconia crown of an upper premolar. Ten zirconia copings were manufactured for each group following manufacturer¿s instructions. Control group consisted on ten metallic copings. A replication technique was followed using elite HD+ polyvinyl siloxane (Zhermack®). Measurements were taken using a stereomicroscope at 50x magnification so as to obtain marginal width in microns and thus determine absolute marginal discrepancy of each coping. Statistical analysis was conducted using IBM SPSS® software. T-test study was conducted in order to compare obtained data.  Results:  Mean marginal absolute discrepancy and marginal width were as follows: 92.14 ± 38.59 and 78.62 ± 31.33 &#956;m for Cerec InLab (Sirona®) CAD/CAM system, 38.71 ± 12.62 and 36.91 ± 13.56 &#956;m for Zirkonzahn (Zirkonzahn®) CAD/CAM system, 77.92 ± 38.01 and 69.42 ± 33.23 &#956;m for Zirkograph 025 ECO (Zirkonzahn®) pantograph system. Control group made of metal copings exhibited 44.11 ± 15.36 and 43.74 ± 15.70 &#956;m. With respect to absolute marginal discrepancy and marginal width, significant differences were observed when comparing Cerec InLab (Sirona®) and Zirkograph 025 ECO (Zirkonzahn®) with control group. Nevertheless, no significant differences were observed between Zirkonzahn (Zirkonzahn®) CAD/CAM system and the control group. Overall level of statistical significance was p &gt; 0.001.  Conclusions: Zirkonzahn® CAD/CAM system was the most accurate system of all. CAD/CAM Cerec InLab system (Sirona®) proved to be the less precise system.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[CAD/CAM]]></kwd>
<kwd lng="es"><![CDATA[discrepancia marginal]]></kwd>
<kwd lng="es"><![CDATA[zirconia]]></kwd>
<kwd lng="es"><![CDATA[sistemas pantográficos]]></kwd>
<kwd lng="en"><![CDATA[CAD/CAM]]></kwd>
<kwd lng="en"><![CDATA[marginal discrepancy]]></kwd>
<kwd lng="en"><![CDATA[zirconia]]></kwd>
<kwd lng="en"><![CDATA[pantograph (milling) systems]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Comparación de la desadaptación marginal de cofias de zirconio (Y-TZP) realizadas con dos sistemas diferentes: CAD/CAM (Cerec) y pantográfico (Zirkonzahn), mediante estereomicroscopio]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[Revista Odontos.]]></source>
<year>2010</year>
<volume>12</volume>
<page-range>8-22</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[CAD/CAM systems available for the fabrication of crown and bridge restorations]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miyazaki]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hotta]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<source><![CDATA[Australian Dental Journal.]]></source>
<year>2011</year>
<volume>56</volume>
<page-range>97-106</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Roberson]]></surname>
<given-names><![CDATA[T.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Heymann]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Swift]]></surname>
<given-names><![CDATA[E.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Sturdevant]]></surname>
<given-names><![CDATA[C.M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Sturdevant's art and science of operative dentistry]]></source>
<year>2006</year>
<edition>5</edition>
<publisher-loc><![CDATA[Elsevier ]]></publisher-loc>
<publisher-name><![CDATA[St. Louis]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kohorst]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Brinkmann]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Borchers]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Stiesch]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Eur J Oral Sci.]]></source>
<year>2009</year>
<volume>117</volume>
<page-range>319-25</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Euán]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Figueras-Álvarez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Cabratosa-Termes]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Brufau-de Barbera]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gomes-Azevedo]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Prosthodont.]]></source>
<year>2012</year>
<volume>21</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>291-5</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[An overview of zirconia ceramics: basic properties and clinical applications]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manicone]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Iommetti]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Raffaelli]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Dent.]]></source>
<year>2007</year>
<volume>35</volume>
<page-range>819-26</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Influence of low-temperature environmental exposure on the mechanical properties and structural stability of dental zirconia]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alghazzawi]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lemons]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Essig]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bartolucci]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Janowski]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Prosthodont.]]></source>
<year>2012</year>
<volume>21</volume>
<page-range>363-9</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Systematic reviews: I. The correlation between laboratory test on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heintze]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Adhes Dent.]]></source>
<year>2007</year>
<volume>9</volume>
<page-range>77-106</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beuer]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Korczynski]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Rezac]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Naumann]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Gernet]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Clinical Clin Cosmet Investig Dent.]]></source>
<year>2010</year>
<volume>2</volume>
<page-range>5-11</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Biscaro]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Bonfiglioli]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Soattin]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Vigolo]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Prosthodont.]]></source>
<year>2013</year>
<volume>22</volume>
<page-range>36-41</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Evaluation of marginal gap of Ni-Cr copings made with conventional and accelerated casting techniques]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tannamala]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Azhagarasan]]></surname>
<given-names><![CDATA[N.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Shankar]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<source><![CDATA[Indian J Dent Res.]]></source>
<year>2013</year>
<volume>24</volume>
<page-range>146-52</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[The estimation of cement film thickness by an in vivo technique]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[McLean]]></surname>
<given-names><![CDATA[J.W.]]></given-names>
</name>
<name>
<surname><![CDATA[von Frauenhofer]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Br Dent J.]]></source>
<year>1971</year>
<volume>131</volume>
<page-range>107-11</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Considerations in measurement of marginal fit]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holmes]]></surname>
<given-names><![CDATA[J.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Bayne]]></surname>
<given-names><![CDATA[S.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Holland]]></surname>
<given-names><![CDATA[G.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Sulik]]></surname>
<given-names><![CDATA[W.D.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Prosthet Dent.]]></source>
<year>1989</year>
<volume>62</volume>
<page-range>405-8</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Clinical fit of allcermic three-unit fixed partial dentures, generated with three different CAD/CAM systems]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reich]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Wichmann]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Nkenke]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Proeschel]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Eur J Oral Sci.]]></source>
<year>2005</year>
<volume>113</volume>
<page-range>174-9</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Marginal and internal fits of fixed dental prostheses zirconia retainers]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beuer]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Aggstaller]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Gernet]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Sorensen]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Dental Materials.]]></source>
<year>2009</year>
<volume>25</volume>
<page-range>94-102</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Fit of single tooth copings: comparison between various manufacturing processes]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grenade]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Mainjot]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vanheusden]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Prosthet Dent.]]></source>
<year>2011</year>
<volume>105</volume>
<page-range>249-55</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kohorst]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Junghanns]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Dittmer]]></surname>
<given-names><![CDATA[M.P.]]></given-names>
</name>
<name>
<surname><![CDATA[Borchers]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Stiesch]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Clin Oral Investig.]]></source>
<year>2011</year>
<volume>15</volume>
<page-range>527-36</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Adaptación marginal y ajuste interno en estructuras de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera y Cerec InLab]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Caparroso-Pérez]]></surname>
<given-names><![CDATA[C.B.]]></given-names>
</name>
<name>
<surname><![CDATA[Marín-Muñóz]]></surname>
<given-names><![CDATA[D.V.]]></given-names>
</name>
<name>
<surname><![CDATA[Velásquez]]></surname>
<given-names><![CDATA[A.E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Revista Facultad de Odontología Universidad de Antioquia.]]></source>
<year>2011</year>
<volume>22</volume>
<page-range>186-97</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Marginal and internal fit of all-ceramic CAD/CAM crown copings on chamfer preparations]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bindl]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Mormann]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Oral Rehabil.]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>441-7</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santamaría]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Aldana]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Martín]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Comparación de la adaptación marginal e interna de las coronas fabricadas con tres sistemas totalmente cerámicos]]></source>
<year>2009</year>
<publisher-name><![CDATA[Institución Universitaria Colegios de Colombia]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A comparative study on the marginal fit of zirconia cores manufactured by CAD/CAM and copy milling methods]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[J.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[T.K.]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[J.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[J.B.]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[S.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Yeo]]></surname>
<given-names><![CDATA[I.S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Dentistry.]]></source>
<year>2013</year>
<volume>3</volume>
<page-range>163</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD/CAM and conventional wax up techniques]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vojdani]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Torabi]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Farjood]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Khaledi]]></surname>
<given-names><![CDATA[A.A.R.]]></given-names>
</name>
</person-group>
<source><![CDATA[J Dent.]]></source>
<year>2013</year>
<volume>14</volume>
<page-range>118-29</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
