<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-199X</journal-id>
<journal-title><![CDATA[Revista odontológica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Odont. Mex]]></abbrev-journal-title>
<issn>1870-199X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Facultad de Odontología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-199X2015000200002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Profundidad de curado de selladores de fosetas y fisuras utilizando luz emitida por diodos (LED) a diferentes distancias]]></article-title>
<article-title xml:lang="en"><![CDATA[Curing depth of pit and fissure sealants with use of light emitting diode (LED) at different distances]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Villarreal Rojas]]></surname>
<given-names><![CDATA[Azucena]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guerrero Ibarra]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Yamamoto Nagano]]></surname>
<given-names><![CDATA[Adolfo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Barceló Santana]]></surname>
<given-names><![CDATA[Federico Humberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Nacional Autónoma de México Facultad de Odontología División de Estudios de Postgrado e Investigación]]></institution>
<addr-line><![CDATA[México Distrito Federal]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2015</year>
</pub-date>
<volume>19</volume>
<numero>2</numero>
<fpage>76</fpage>
<lpage>80</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-199X2015000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-199X2015000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-199X2015000200002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La colocación de selladores de fosetas y fisuras es un procedimiento seguro, efectivo y económico en la prevención de caries. Actualmente los clínicos prefieren lámparas de LED. Frecuentemente en odontopediatría se tienen complicaciones como falta de cooperación del paciente y tamaño reducido de la apertura bucal. Esto podría resultar en el aumento de la distancia entre la fuente de luz y el sellador. Objetivo: El propósito de este estudio fue determinar si aumentar la distancia entre la fuente de luz y el sellador de fosetas y fisuras afecta su profundidad de curado. Material y métodos: Se fotocuraron 90 muestras de sellador de fosetas y fisuras (Helioseal F®), durante 20 segundos con lámpara LED Bluephase C5 (Ivoclar Vivadent®), 30 con la fuente de luz a 0 mm de distancia, 30 a 5 mm y 30 a 10 mm. Se eliminó con una espátula para resinas (Suter Dental®) el material no polimerizado. La muestra se midió con un Vernier electrónico en mm y el valor obtenido se dividió entre dos (Norma 27 ADA). Los resultados fueron evaluados con las pruebas ANOVA y Tukey. Resultados: El grupo a 0 mm tuvo una profundidad de curado de 2.01 mm (DE 0.11) y el grupo a 10 mm fue el que menor profundidad de curado presentó con 1.62 mm (DE 0.08). Se encontraron diferencias estadísticamente significativas en los valores promedio al comparar los tres grupos (p < 0.05). Conclusión: Alejar la fuente de luz de los selladores afecta su profundidad de curado.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[In the process of caries prevention, placement of pit and fissure sealants is a low-priced, effective and safe procedure. Presently, clinical operators prefer LED lamps. In pediatric dentistry, certain complications might arise such as lack of patient cooperation and small oral opening. This could result in increase of distance between light source and sealant. Objective: The purpose of the present study was to determine whether increase of distance between light source and pit and fissure sealant affected curing depth. Material and methods: 90 samples of pit and fissure sealant Helioseal F® were light-cured for 20 seconds with a Bluephase C5 LED lamp (Ivoclar Vivadent®), 30 seconds with the light source at a distance of 0 mm, 30 seconds at 5 mm and 30 seconds at 10 mm. Non-polymerized material was removed with a spatula for resin (Suter Dental®). The sample was measured in mm with an electronic Vernier caliper; obtained value was divided into two (ADA's Norm 27). Results were assessed with ANOVA and Tukey tests. Results: The group treated at 0 mm exhibited curing depth of 2.01 mm (SD 0.11). The group treated at 10 mm, with 1.62 mm (SD 0.08) showed the least amount of curing depth. Statistically significant differences were found in average values when comparing the three groups (p < 0.05). Conclusion: Distancing light source from sealants affects their curing depth.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Profundidad de curado]]></kwd>
<kwd lng="es"><![CDATA[selladores de fosetas y fisuras]]></kwd>
<kwd lng="es"><![CDATA[LED]]></kwd>
<kwd lng="en"><![CDATA[Curing depth]]></kwd>
<kwd lng="en"><![CDATA[pits and fissure sealants]]></kwd>
<kwd lng="en"><![CDATA[LED]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="justify"><font face="verdana" size="4">Trabajos originales</font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="4"><b>Profundidad de curado de selladores de fosetas y fisuras utilizando luz emitida por diodos (LED) a diferentes distancias</b></font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="2"><b>Azucena Villarreal Rojas,<sup>*</sup> Jorge Guerrero Ibarra,<sup>&sect;</sup> Adolfo Yamamoto Nagano,<sup>II</sup> Federico Humberto Barcel&oacute; Santana<sup>&sect;</sup></b></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><i>* Egresada de la especialidad de Odontopediatr&iacute;a.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><i><sup>&sect;</sup> Laboratorio de Materiales Dentales.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><i><sup>II</sup> Coordinador de la Especialidad de Odontopediatr&iacute;a.</i></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><i>Facultad de Odontolog&iacute;a, Divisi&oacute;n de Estudios de Postgrado e Investigaci&oacute;n, UNAM.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><a name="n1b"></a><a href="#n1a">Correspondencia</a></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>RESUMEN</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La colocaci&oacute;n de selladores de fosetas y fisuras es un procedimiento seguro, efectivo y econ&oacute;mico en la prevenci&oacute;n de caries. Actualmente los cl&iacute;nicos prefieren l&aacute;mparas de LED. Frecuentemente en odontopediatr&iacute;a se tienen complicaciones como falta de cooperaci&oacute;n del paciente y tama&ntilde;o reducido de la apertura bucal. Esto podr&iacute;a resultar en el aumento de la distancia entre la fuente de luz y el sellador. <b>Objetivo:</b> El prop&oacute;sito de este estudio fue determinar si aumentar la distancia entre la fuente de luz y el sellador de fosetas y fisuras afecta su profundidad de curado. <b>Material y m&eacute;todos:</b> Se fotocuraron 90 muestras de sellador de fosetas y fisuras (Helioseal F<sup>&reg;</sup>), durante 20 segundos con l&aacute;mpara LED Bluephase C5 (Ivoclar Vivadent<sup>&reg;</sup>), 30 con la fuente de luz a 0 mm de distancia, 30 a 5 mm y 30 a 10 mm. Se elimin&oacute; con una esp&aacute;tula para resinas (Suter Dental<sup>&reg;</sup>) el material no polimerizado. La muestra se midi&oacute; con un Vernier electr&oacute;nico en mm y el valor obtenido se dividi&oacute; entre dos (Norma 27 ADA). Los resultados fueron evaluados con las pruebas ANOVA y Tukey. <b>Resultados:</b> El grupo a 0 mm tuvo una profundidad de curado de 2.01 mm (DE 0.11) y el grupo a 10 mm fue el que menor profundidad de curado present&oacute; con 1.62 mm (DE 0.08). Se encontraron diferencias estad&iacute;sticamente significativas en los valores promedio al comparar los tres grupos (p &lt; 0.05). <b>Conclusi&oacute;n:</b> Alejar la fuente de luz de los selladores afecta su profundidad de curado.</font></p>      <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> Profundidad de curado, selladores de fosetas y fisuras, LED.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>INTRODUCCI&Oacute;N</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Debido a la morfolog&iacute;a de los molares y premolares con fosas y fisuras marcadas y a los deficientes h&aacute;bitos de limpieza, se acumulan restos de alimentos y bacterias que provocan la aparici&oacute;n de caries. Debido a ello, se han implementado diversas t&eacute;cnicas encaminadas a lograr que las fosas y fisuras retengan placa con menos facilidad.<sup>1</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Buonocore, en 1955 introdujo el primer sellador de fosetas y fisuras.<sup>2</sup> Actualmente, tras la incorporaci&oacute;n de las t&eacute;cnicas de grabado &aacute;cido, su utilizaci&oacute;n en pacientes j&oacute;venes es casi rutinaria.<sup>1</sup></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La eficacia de los selladores para evitar las caries var&iacute;a desde 83% despu&eacute;s de un a&ntilde;o, hasta 53% despu&eacute;s de 15 a&ntilde;os.<sup>3</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">La retenci&oacute;n y longevidad de los selladores depende de 3 factores:</font></p>  	    <p align="justify"><font face="verdana" size="2">1) Penetrabilidad del &aacute;cido grabador al esmalte.</font></p>  	    <p align="justify"><font face="verdana" size="2">2) Sellado marginal.</font></p>  	    <p align="justify"><font face="verdana" size="2">3) Resistencia a la abrasi&oacute;n.</font></p>  	    <p align="justify"><font face="verdana" size="2">Este &uacute;ltimo aspecto es el que resulta m&aacute;s afectado por la reducci&oacute;n de la polimerizaci&oacute;n del material.<sup>4</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Actualmente, los selladores de fosetas y fisuras son compuestos a base de resina, con fotoiniciadores en su composici&oacute;n, tales como la canforoquinona, la cual es sensible a longitudes de onda entre 450 y 490 mm, y una intensidad de alrededor de 300 mW/mm<sup>2</sup>.<sup>5,6</sup> Dicha longitud de onda e intensidad son alcanzadas por diferentes fuentes de luz, como son: l&aacute;mparas de luz hal&oacute;gena, l&aacute;mparas de arco de plasma, l&aacute;mparas de l&aacute;ser de arg&oacute;n y l&aacute;mparas de luz emitida por diodos (LED), siendo la tendencia actual la utilizaci&oacute;n de l&aacute;mparas LED.</font></p>  	    <p align="justify"><font face="verdana" size="2">Considerando que los selladores son compuestos a base de resina, su polimerizaci&oacute;n se ve afectada por la intensidad de luz que incide en ellos. Ya que si s&oacute;lo se consigue una polimerizaci&oacute;n parcial, afectar&aacute; considerablemente sus propiedades mec&aacute;nicas y f&iacute;sicas. Es importante llevar a cabo el fotocurado del material con una distancia adecuada entre la superficie del sellador y la fuente de luz que permita que el material polimerice en su totalidad.</font></p>  	    <p align="justify"><font face="verdana" size="2">Las l&aacute;mparas de luz hal&oacute;gena tienen la desventaja de funcionar a trav&eacute;s del calentamiento de una fibra de tungsteno, lo cual trae consigo la generaci&oacute;n de calor, los dise&ntilde;os son relativamente grandes y las de fibra &oacute;ptica son muy fr&aacute;giles y, por lo tanto susceptibles a fracturarse.</font></p>  	    <p align="justify"><font face="verdana" size="2">Las l&aacute;mparas LED tienen algunas ventajas sobre las l&aacute;mparas de luz hal&oacute;gena, por ejemplo, no generan calor, los dise&ntilde;os son ligeros y ergon&oacute;micos.<sup>6&#45;8</sup> Un estudio publicado report&oacute; que el grado de conversi&oacute;n alcanzado con las unidades de curado basadas en diodos (LED) es &uacute;nicamente 5&#45;10% menor que el grado de conversi&oacute;n alcanzado con unidades de curado hal&oacute;genas.<sup>7</sup> Lo anterior trae como consecuencia que la tendencia actual sea la utilizaci&oacute;n de l&aacute;mparas de LED.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Hoy en d&iacute;a, a&uacute;n persisten algunos cuestionamientos acerca de la eficacia en la polimerizaci&oacute;n de las l&aacute;mparas LED, que han sido abordados en diversos estudios,<sup>9&#45;11</sup> algunos de los cuales consideran la t&eacute;cnica usada durante la polimerizaci&oacute;n,<sup>12&#45;15</sup> mientras que otros han comparado l&aacute;mparas LED con l&aacute;mparas hal&oacute;genas.<sup>13,15&#45;20</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">La polimerizaci&oacute;n parcial puede aumentar la absorci&oacute;n de agua y la solubilidad de los mon&oacute;meros sin reaccionar, lo que afecta la longevidad y est&eacute;tica de la restauraci&oacute;n.<sup>5</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Frecuentemente en odontopediatr&iacute;a se tiene la desventaja de no contar con las condiciones ideales para la colocaci&oacute;n de selladores de fosetas y fisuras, por ejemplo en cuanto a la cooperaci&oacute;n del paciente y en cuanto a que la apertura bucal en pacientes pedi&aacute;tricos es mucho menor que en pacientes adolescentes y adultos. Esto, podr&iacute;a resultar en la necesidad de aumentar la distancia entre la fuente de luz y el sellador, lo cual probablemente disminuya su profundidad de polimerizaci&oacute;n, afectando de manera negativa sus propiedades f&iacute;sicas y mec&aacute;nicas.</font></p>  	    <p align="justify"><font face="verdana" size="2">El objetivo de este estudio es determinar si la distancia entre la fuente de luz (LED) y el sellador afecta la profundidad de curado de selladores de fosetas y fisuras.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>MATERIAL Y M&Eacute;TODOS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Para este estudio se utiliz&oacute; una l&aacute;mpara de LED Bluephase C5 (Ivoclar Vivadent). El sellador utilizado fue Helioseal F (Ivoclar Vivadent).</font></p>  	    <p align="justify"><font face="verdana" size="2">Para llevar a cabo la prueba de profundidad de curado se sigui&oacute; la especificaci&oacute;n No. 27 de la ADA; se utiliz&oacute; un vidrio de 20 mm por 20 mm de 2 mm de grosor, sobre el cual se coloc&oacute; un molde hacedor de muestras (con el que se obtuvieron muestras de 4 mm de di&aacute;metro y 6 mm de longitud).</font></p>  	    <p align="justify"><font face="verdana" size="2">Para mantener la distancia entre la superficie del sellador de fosetas y fisuras y la fuente de luz se utilizaron un tubo de vidrio con una longitud de 5 mm y di&aacute;metro de 6 mm y un tubo de vidrio con una longitud de 10 mm y di&aacute;metro de 6 mm <i>(<a href="#f1">Figura 1</a>).</i></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f1"></a></font></p>  	    ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f1.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Se midi&oacute; la profundidad de polimerizaci&oacute;n en 90 espec&iacute;menes de selladores de fosetas y fisuras. Se agruparon los espec&iacute;menes en tres grupos (30 espec&iacute;menes por grupo). Un grupo se fotocur&oacute; colocando la l&aacute;mpara directamente sobre la superficie del sellador, otro grupo se fotocur&oacute; a una distancia de5mmcontroladacolocando la l&aacute;mpara sobre el tubo de vidrio de 5 mm de longitud, y otro grupo se fotocur&oacute; a una distancia de 10 mm controlada colocando la l&aacute;mpara sobre el tubo de vidrio de 10 mm de longitud. Cada esp&eacute;cimen fue fotocurado durante 20 segundos siguiendo las instrucciones del fabricante.</font></p>  	    <p align="justify"><font face="verdana" size="2">Una vez terminado el proceso de fotocurado, cada esp&eacute;cimen fue retirado del hacedor de muestras y el material no polimerizado se retir&oacute; con una esp&aacute;tula para resinas (Suter Dental<sup>&reg;</sup>) <i>(<a href="#f2">Figuras 2</a> a <a href="#f7">7</a>) (<a href="#f3">3</a>, <a href="#f4">4</a>, <a href="#f5">5</a>, <a href="#f6">6</a>).</i></font></p>      <p align="center"><font face="verdana" size="2"><a name="f2"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f2.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f3"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f3.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f4"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f4.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f5"></a></font></p>  	    ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f5.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f6"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f6.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f7"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f7.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Se midi&oacute; la altura del cilindro de material curado en mil&iacute;metros con un Vernier digital (Maxcal, USA) y se dividi&oacute; entre dos (especificaci&oacute;n No. 27 de la ADA). El valor obtenido es la profundidad de curado.</font></p>  	    <p align="justify"><font face="verdana" size="2">Los resultados fueron capturados en una hoja de c&aacute;lculo Excel y procesados para su an&aacute;lisis en un paquete estad&iacute;stico Sigma Stat 2.0, empleando una prueba ANOVA de una sola v&iacute;a y una comparaci&oacute;n de grupos con la prueba de Tukey.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>RESULTADOS</b></font></p>  	    <p align="justify"><font face="verdana" size="2">El grupo que fue fotocurado a 0 mm registr&oacute; un promedio de profundidad de curado de 2.014 mm (D.E. 0.113) <i>(<a href="#c1">Cuadro I</a>),</i> mientras que el grupo a 10 mm fue el que menor profundidad de curado present&oacute; con 1.623 mm (D.E. 0.0847) <i>(<a href="#f8">Figura 8</a>).</i></font></p>  	    ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><a name="c1"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2c1.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f8"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2f8.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Se encontraron diferencias estad&iacute;sticamente significativas en los valores promedio al comparar los tres grupos a una p &lt; 0.05 (Tukey) <i>(<a href="#c2">Cuadro II</a>).</i></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="c2"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n2/a2c2.jpg"></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>DISCUSI&Oacute;N</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Se ha demostrado que la polimerizaci&oacute;n de los compuestos a base de resina utilizando l&aacute;mpara LED es 6% mayor que la polimerizaci&oacute;n lograda con l&aacute;mpara hal&oacute;gena,<sup>8</sup> por lo que la tendencia actual es la utilizaci&oacute;n de l&aacute;mparas de LED.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Soh y cols. encontraron que la profundidad de curado de las resinas compuestas depende de la unidad de luz (l&aacute;mpara utilizada) y del modo de exposici&oacute;n.<sup>10</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Santos y cols. encontraron que la profundidad de curado de resinas compuestas disminuye dr&aacute;sticamente entre 4 y 5 mm de profundidad utilizando l&aacute;mpara de luz hal&oacute;gena y entre 2 y 3 mm utilizando l&aacute;mpara LED, colocando la fuente de luz directamente sobre la resina.<sup>21</sup> Estos resultados concuerdan con los nuestros ya que encontramos diferencias significativas en la profundidad de curado cuando la fuente de luz se coloc&oacute; directamente sobre el sellador de fosetas y fisuras(2.014mm), a 5 mm de distancia (1.843 mm) y a 10 mm de distancia (1.623 mm).</font></p>  	    <p align="justify"><font face="verdana" size="2">Se han realizado un sinn&uacute;mero de estudios con el objetivo de determinar la eficacia de los selladores de fosetas y fisuras en virtud de su viscosidad,<sup>17,22,23</sup> su material de relleno,<sup>2,22</sup> comparando los selladores con y sin pigmentos,<sup>2,17</sup> comparando selladores autocurables y fotocurables, comparando diferentes fuentes de luz para su fotocurado,<sup>2,6,17,24</sup> comparando el tiempo de fotocurado,<sup>6,17,25&#45;27</sup> as&iacute; como comparando diferentes t&eacute;cnicas de preparaci&oacute;n de la superficie del esmalte (grabado &aacute;cido, aire abrasivo m&aacute;s grabado &aacute;cido, ameloplastia m&aacute;s grabado &aacute;cido).<sup>2,22,23</sup> Sin embargo, los estudios que se han llevado a cabo para determinar la efectividad de las l&aacute;mparas de LED no han considerado la distancia entre la fuente de luz y el material a fotocurar. Por lo que este estudio sugiere una nueva l&iacute;nea de investigaci&oacute;n.</font></p>  	    <p align="justify"><font face="verdana" size="2">Nuestros resultados demuestran que la distancia entre la fuente de luz y el material a fotocurar afecta considerablemente la calidad de fotocurado de materiales a base de resina.</font></p>  	    <p align="justify"><font face="verdana" size="2">La profundidad de las fosetas y fisuras var&iacute;a de 1 a 3 mm y la altura de las c&uacute;spides puede llegar a ser de 3 mm, por lo cual el sellador de fosetas y fisuras no podr&aacute; ser fotocurado a una distancia menor de 3 mm.</font></p>  	    <p align="justify"><font face="verdana" size="2">Por lo anterior recomendamos que durante el foto&#45;curado de selladores de fosetas y fisuras, la punta de la l&aacute;mpara se coloque directamente sobre la superficie oclusal del molar o premolar, para optimizar al m&aacute;ximo sus resultados.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se sugieren futuros estudios con el fin de determinar el grado de conversi&oacute;n de los selladores de fosetas y fisuras utilizando l&aacute;mparas de LED y l&aacute;mparas de luz hal&oacute;gena a diferentes distancias, para determinar a cu&aacute;l de los dos tipos de l&aacute;mparas les afecta m&aacute;s el aumento de la distancia.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>CONCLUSIONES</b></font></p>  	    <p align="justify"><font face="verdana" size="2">En este estudio y bajo esta metodolog&iacute;a se demostr&oacute; que la profundidad de curado de selladores de fosetas y fisuras disminuye conforme aumenta la distancia entre la fuente de luz y la superficie del sellador.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Por lo tanto, podemos afirmar que alejar inadvertidamente la fuente de luz de los selladores afecta negativamente su curado reduciendo la calidad y duraci&oacute;n del material en la boca.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>REFERENCIAS</b></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">1. Pinkham J. <i>Odontolog&iacute;a pedi&aacute;trica.</i> 2a edici&oacute;n. M&eacute;xico, D.F.: Ed. McGraw&#45;Hill Interamericana; 1998: pp. 529&#45;537.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103244&pid=S1870-199X201500020000200001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">2. Simoensen R. Pit and fissure sealant: review of the literature. <i>Pediatr Dent.</i> 2002; 24: 393&#45;414.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103246&pid=S1870-199X201500020000200002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">3. Irinoda Y, Matsumura Y, Kito H, Nakano T, Toyama T, Nakagaki H et al. Effect of sealant viscosity on the penetration of resin into etched human enamel. <i>Oper Dent.</i> 2000; 25: 274&#45;282.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103248&pid=S1870-199X201500020000200003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">4. Barberia E. <i>Odontopediatr&iacute;a.</i> 2a edici&oacute;n. Barcelona, Espa&ntilde;a: Ed. Masson; 2001: pp. 190&#45;191.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103250&pid=S1870-199X201500020000200004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">5. Deb S, Mallet R, Millar B. The effect of curing with plasma light on the shrinkage of dental restorative materials. <i>J Oral Rehabil.</i> 2003; 30: 723&#45;728.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103252&pid=S1870-199X201500020000200005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">6. Gigo D, De Oliveira G, Carneiro C, Pereira J, De Lima M. Microhardness of resin&#45;based materials polymerized with LED and halogen curing units. <i>Braz Dent J.</i> 2005; 16 (2): 98&#45;102.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103254&pid=S1870-199X201500020000200006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">7. Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G. Influence of light intensity from different curing units upon composite temperature rise. <i>J Oral Rehabil.</i> 2005; 32: 362&#45;367.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103256&pid=S1870-199X201500020000200007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">8. Halvorson R, Erickson R, Davidson C. Polymerization efficiency of curing lamps: a universal energy conversion relationship predictive of conversion of resin&#45;based composite. <i>Oper Dent.</i> 2004; 29 (1): 105&#45;111.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103258&pid=S1870-199X201500020000200008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">9. Yap A, Saw T, Cao T. Composite cure and pulp&#45;cell cytotoxicity associated with LED curing lights. <i>Oper Dent.</i> 2004; 29 (1): 92&#45;99.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103260&pid=S1870-199X201500020000200009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">10. Soh M, Yap A, Siow K. Comparative depths of cure among various curing light types and methods. <i>Oper Dent.</i> 2004; 29 (1): 9&#45;15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103262&pid=S1870-199X201500020000200010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">11. Yap A, Soh M. Curing efficacy of a new generation high&#45;power LED lamp. <i>Oper Dent.</i> 2005; 30 (6): 758&#45;763.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103264&pid=S1870-199X201500020000200011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">12. Coelho M, Santos G, Nagem H, Mondelli R, El&#45;Mowafy O. Effect of light curing method on volumetric polymerization shrinkage of resin composites. <i>Oper Dent.</i> 2004; 29 (2): 157&#45;161.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103266&pid=S1870-199X201500020000200012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">13. Yap A, Soh M, Han V, Siow K. Influence of curing lights and modes on cross&#45;link density of dental composites. <i>Oper Dent.</i> 2004; 29&nbsp;(4): 410&#45;415.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103268&pid=S1870-199X201500020000200013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">14. Neo B, Soh M, Teo J, Yap A. Effectiveness of composite cure associated with different light&#45;curing regimes. <i>Oper Dent.</i> 2005; 30&nbsp;(6): 671&#45;675.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103270&pid=S1870-199X201500020000200014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">15. Tarle Z, Knezevic A, Demoli N, Meniga A, Unterbrink G, Ristic M et al. Comparison of composite curing parameters: effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage. <i>Oper Dent.</i> 2006; 31 (2): 219&#45;226.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103272&pid=S1870-199X201500020000200015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">16. Vandewalle K, Roberts H, Tiba A, Charlton D. Thermal emission and curing efficiency of LED and halogen curing lights. <i>Oper</i> <i>Dent.</i> 2005; 30 (2): 257&#45;264.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103274&pid=S1870-199X201500020000200016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">17. Mavropoulos A, Staudt C, Kiliaridis S, Krejci I. Light curing time reduction: in vitro evaluation of new intensive light&#45;emitting diode curing units. <i>Eur J Orthod.</i> 2005; 27: 408&#45;412.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103276&pid=S1870-199X201500020000200017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">18. Nomoto R, McCabe J, Hirano S. Comparison of halogen, plasma and LED curing units. <i>Oper Dent.</i> 2004; 29 (3): 287&#45;294.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103278&pid=S1870-199X201500020000200018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">19. Soh M, Yap A, Yu T, Shen Z. Analysis of the degree of conversion of LED and halogen lights using micro&#45;raman spectroscopy. <i>Oper Dent.</i> 2004; 29 (5): 571&#45;577.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103280&pid=S1870-199X201500020000200019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">20. Bala O, &Uuml;ctasli M, T&uuml;z M. Barcoll hardness of different resin&#45;based composites cured by halogen of light emitting diode (LED). <i>Oper Dent.</i> 2005; 30 (1): 69&#45;74.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103282&pid=S1870-199X201500020000200020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">21. Santos G, Medeiros I, Fellows C, Muench A, Braga R. Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro&#45;raman spectroscopy. <i>Oper Dent.</i> 2007; 31 (1): 79&#45;83.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103284&pid=S1870-199X201500020000200021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">22. Barnes D, Kihn P, Fraunhofer J, Elsabach A. Flow characteristics and sealing ability of fissure sealants. <i>Oper Dent.</i> 2000; 25: 306&#45;310.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103286&pid=S1870-199X201500020000200022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">23. Hatibovik S, Braverman I. Microleakage of sealants after conventional, bur, and air&#45;abrasion preparation of pits and fissures. <i>Pediatr Dent.</i> 1998; 20 (3): 173&#45;176.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103288&pid=S1870-199X201500020000200023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">24. Millar B, Nicholson J. Effect of curing with anplasma light on the properties of polymerizable dental restorative materials. <i>J Oral</i> <i>Rehabil.</i> 2001; 28: 549&#45;552.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103290&pid=S1870-199X201500020000200024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">25. Shortall A.Howlightsourceand product shade influence cure depth for a contemporary composite. <i>J Oral Rehabil.</i> 2005; 32: 906&#45;911.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103292&pid=S1870-199X201500020000200025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">26. Silta T, Dunn W, Peters C. Effect of shorter polymerization times when using the latest generation of light&#45;emitting diodes. <i>Am J</i> <i>Orthod Dentofacial Orthop.</i> 2005; 128: 744&#45;748.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103294&pid=S1870-199X201500020000200026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">27. Staudt C, Marvopoulos A, Boullaguet S, Kiliaridis S, Krejci I. Light&#45;curing time reduction with a new high&#45;power halogen lamp. <i>Am J Orthod Dentofacial Orthop.</i> 2005; 128: 749&#45;754.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=9103296&pid=S1870-199X201500020000200027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><a name="n1a"></a><a href="#n1b"><img src="/img/revistas/rom/v19n2/flecha.jpg"></a>Direcci&oacute;n para correspondencia:    <br> 	<b>Azucena Villarreal Rojas</b>    ]]></body>
<body><![CDATA[<br> 	E&#45;mail: <a href="mailto:azucenavr@yahoo.com.mx">azucenavr@yahoo.com.mx</a></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Nota</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Este art&iacute;culo puede ser consultado en versi&oacute;n completa en <a href="http://www.medigraphic.com/facultadodontologiaunam" target="_blank">http://www.medigraphic.com/facultadodontologiaunam</a></font></p>      ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pinkham]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Odontología pediátrica]]></source>
<year>1998</year>
<edition>2</edition>
<page-range>529-537</page-range><publisher-loc><![CDATA[México^eD.F. D.F.]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill Interamericana]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simoensen]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pit and fissure sealant: review of the literature]]></article-title>
<source><![CDATA[Pediatr Dent]]></source>
<year>2002</year>
<volume>24</volume>
<page-range>393-414</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Irinoda]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Matsumura]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Kito]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Nakano]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Toyama]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Nakagaki]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of sealant viscosity on the penetration of resin into etched human enamel]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2000</year>
<volume>25</volume>
<page-range>274-282</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barberia]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Odontopediatría]]></source>
<year>2001</year>
<edition>2</edition>
<publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Ed. Masson]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deb]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mallet]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Millar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of curing with plasma light on the shrinkage of dental restorative materials]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2003</year>
<volume>30</volume>
<page-range>723-728</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gigo]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[De Oliveira]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Carneiro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Pereira]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[De Lima]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microhardness of resin-based materials polymerized with LED and halogen curing units]]></article-title>
<source><![CDATA[Braz Dent J]]></source>
<year>2005</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>98-102</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Knezevic]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Tarle]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Meniga]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sutalo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Pichler]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of light intensity from different curing units upon composite temperature rise]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>362-367</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Halvorson]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Erickson]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Davidson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Polymerization efficiency of curing lamps: a universal energy conversion relationship predictive of conversion of resin-based composite]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>105-111</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Saw]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Cao]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Composite cure and pulp-cell cytotoxicity associated with LED curing lights]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>92-99</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Siow]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative depths of cure among various curing light types and methods]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>9-15</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Soh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Curing efficacy of a new generation high-power LED lamp]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2005</year>
<volume>30</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>758-763</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coelho]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Nagem]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Mondelli]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[El-Mowafy]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of light curing method on volumetric polymerization shrinkage of resin composites]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>157-161</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Soh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Siow]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of curing lights and modes on cross-link density of dental composites]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>410-415</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neo]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Soh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Teo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effectiveness of composite cure associated with different light-curing regimes]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2005</year>
<volume>30</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>671-675</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tarle]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Knezevic]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Demoli]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Meniga]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Unterbrink]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Ristic]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of composite curing parameters: effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2006</year>
<volume>31</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>219-226</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vandewalle]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Roberts]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tiba]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Charlton]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal emission and curing efficiency of LED and halogen curing lights]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2005</year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>257-264</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mavropoulos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Staudt]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Kiliaridis]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Krejci]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Light curing time reduction: in vitro evaluation of new intensive light-emitting diode curing units]]></article-title>
<source><![CDATA[Eur J Orthod]]></source>
<year>2005</year>
<volume>27</volume>
<page-range>408-412</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nomoto]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[McCabe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hirano]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of halogen, plasma and LED curing units]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>287-294</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Yap]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of the degree of conversion of LED and halogen lights using micro-raman spectroscopy]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2004</year>
<volume>29</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>571-577</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bala]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Üctasli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Tüz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Barcoll hardness of different resin-based composites cured by halogen of light emitting diode (LED)]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2005</year>
<volume>30</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>69-74</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Medeiros]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Fellows]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Muench]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Braga]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-raman spectroscopy]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2007</year>
<volume>31</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>79-83</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barnes]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Kihn]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Fraunhofer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Elsabach]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow characteristics and sealing ability of fissure sealants]]></article-title>
<source><![CDATA[Oper Dent]]></source>
<year>2000</year>
<volume>25</volume>
<page-range>306-310</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hatibovik]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Braverman]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microleakage of sealants after conventional, bur, and air-abrasion preparation of pits and fissures]]></article-title>
<source><![CDATA[Pediatr Dent]]></source>
<year>1998</year>
<volume>20</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>173-176</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Millar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Nicholson]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of curing with anplasma light on the properties of polymerizable dental restorative materials]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2001</year>
<volume>28</volume>
<page-range>549-552</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shortall]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Howlightsourceand product shade influence cure depth for a contemporary composite]]></article-title>
<source><![CDATA[J Oral Rehabil]]></source>
<year>2005</year>
<volume>32</volume>
<page-range>906-911</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silta]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Dunn]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Peters]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of shorter polymerization times when using the latest generation of light-emitting diodes]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2005</year>
<volume>128</volume>
<page-range>744-748</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Staudt]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Marvopoulos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Boullaguet]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kiliaridis]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Krejci]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Light-curing time reduction with a new high-power halogen lamp]]></article-title>
<source><![CDATA[Am J Orthod Dentofacial Orthop]]></source>
<year>2005</year>
<volume>128</volume>
<page-range>749-754</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
