<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-199X</journal-id>
<journal-title><![CDATA[Revista odontológica mexicana]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Odont. Mex]]></abbrev-journal-title>
<issn>1870-199X</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Facultad de Odontología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-199X2015000100007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Zirconia para rehabilitación completa maxilar sobre implantes: Caso clínico]]></article-title>
<article-title xml:lang="en"><![CDATA[Use of zirconia in full maxillary rehabilitation on implants: Clinical case report]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pimentel Hernández]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Salazar Urquiza]]></surname>
<given-names><![CDATA[América]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Nacional Autónoma de México Facultad de Odontología División de Estudios de Postgrado e Investigación]]></institution>
<addr-line><![CDATA[México Distrito Federal]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2015</year>
</pub-date>
<volume>19</volume>
<numero>1</numero>
<fpage>43</fpage>
<lpage>47</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-199X2015000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-199X2015000100007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-199X2015000100007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La zirconia (ZrO2) es un material cerámico con propiedades mecánicas adecuadas para uso en estructuras sobre implantes. Los núcleos de zirconia para prótesis parcial fija en dientes e implantes anteriores y posteriores ahora están disponibles. Actualmente, la exactitud y precisión en la elaboración de estructuras son un prerrequisito para el éxito a largo plazo en restauraciones implanto soportadas. La elaboración de estructuras de zirconia requiere de un amplio conocimiento por parte del clínico y el técnico para lograr un adecuado ajuste y pasividad. En este artículo se describe la elaboración de una estructura de ZrO2, y coronas individuales para rehabilitar el segmento maxilar con seis implantes.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Zirconia (ZrO2) is a ceramic material possessing suitable mechanic properties for usage in frameworks over implants. Presently, there is availability of zirconia cores for fixed partial prostheses in anterior and posterior teeth and implants. Accuracy and precision in framework manufacturing are a pre-requisite for long-term success in restorations supported by implants. Manufacturing of zirconia framework requires wide knowledge and skill in clinical operators as well as technicians in order to achieve suitable adjustment and passiveness. The present article describes the manufacture of a ZrO2 structure and individual crowns to rehabilitate the maxillary segment with six implants.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Zirconia]]></kwd>
<kwd lng="es"><![CDATA[implantes dentales]]></kwd>
<kwd lng="es"><![CDATA[restauraciones cerámicas]]></kwd>
<kwd lng="en"><![CDATA[Zirconia]]></kwd>
<kwd lng="en"><![CDATA[dental implants]]></kwd>
<kwd lng="en"><![CDATA[ceramic restorations]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="justify"><font face="verdana" size="4">Casos cl&iacute;nicos</font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="center"><font face="verdana" size="4"><b>Zirconia para rehabilitaci&oacute;n completa maxilar sobre implantes.</b> <b>Caso cl&iacute;nico</b></font></p>  	    <p align="center"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="center"><font face="verdana" size="2"><b>Jorge Pimentel Hern&aacute;ndez,<sup>*</sup> Am&eacute;rica Salazar Urquiza<sup>&sect;</sup></b></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><i>* Profesor del Departamento de Pr&oacute;tesis Bucal e Implantolog&iacute;a.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><i><sup>&sect;</sup> Profesor del Departamento de Implantolog&iacute;a.</i></font></p>  	    <p align="justify"><font face="verdana" size="2"><i>Divisi&oacute;n de Estudios de Postgrado e Investigaci&oacute;n de la Facultad de Odontolog&iacute;a, UNAM.</i></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><a name="n1b"></a><a href="#n1a">Correspondencia</a></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>RESUMEN</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La zirconia (ZrO<sub>2</sub>) es un material cer&aacute;mico con propiedades mec&aacute;nicas adecuadas para uso en estructuras sobre implantes. Los n&uacute;cleos de zirconia para pr&oacute;tesis parcial fija en dientes e implantes anteriores y posteriores ahora est&aacute;n disponibles. Actualmente, la exactitud y precisi&oacute;n en la elaboraci&oacute;n de estructuras son un prerrequisito para el &eacute;xito a largo plazo en restauraciones implanto soportadas. La elaboraci&oacute;n de estructuras de zirconia requiere de un amplio conocimiento por parte del cl&iacute;nico y el t&eacute;cnico para lograr un adecuado ajuste y pasividad. En este art&iacute;culo se describe la elaboraci&oacute;n de una estructura de ZrO<sub>2</sub>, y coronas individuales para rehabilitar el segmento maxilar con seis implantes.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> Zirconia, implantes dentales, restauraciones cer&aacute;micas.</font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>INTRODUCCI&Oacute;N</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La zirconia es un di&oacute;xido cristalino de <i>zirconium.</i> Sus propiedades mec&aacute;nicas son muy similares a las de otros metales y tiene un color similar al color del diente.<sup>1</sup> En 1975, Garvie propuso un modelo para racionalizar las propiedades mec&aacute;nicas de la zirconia, y en virtud de esto ha sido llamado &#171;acero cer&aacute;mico&#187;.<sup>2</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Los cristales de zirconia pueden ser organizados en tres diferentes patrones: monocl&iacute;nica (M), c&uacute;bica (C) y tetragonal (T). Uniendo el ZrO<sub>2</sub> con otros &oacute;xidos met&aacute;licos, por ejemplo MgO, CaO, o Y<sub>2</sub>O<sub>3</sub>, se obtiene una gran estabilidad molecular.<sup>1</sup> La zirconia estabilizada con itrio, es conocida como zirconia tetragonal policristalina (TZP) y es actualmente la combinaci&oacute;n m&aacute;s estudiada.<sup>3</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">El primer prop&oacute;sito del uso de &oacute;xido de zirconia en el &aacute;rea m&eacute;dica fue hecho en 1969 para la aplicaci&oacute;n en ortopedia, principalmente como un nuevo material para reemplazar la cabeza del f&eacute;mur, reemplazada tradicionalmente con pr&oacute;tesis del titanio y al&uacute;mina.<sup>4</sup></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Las propiedades de la zirconia son similares a las del acero inoxidable, es un material radiopaco y presenta una resistencia a la tracci&oacute;n que puede ser de 900 a 1,200 MPa y resistencia a la compresi&oacute;n alrededor de los 2,000 MPa.<sup>5</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">La resistencia a la fractura del &oacute;xido de zirconia se debe a que en el momento de una fisura, &eacute;sta produce un aumento de energ&iacute;a provocando presiones tangenciales y un cambio de estructura, pasando de su forma tetragonal a la monocl&iacute;nica (que tiene un 4.7% m&aacute;s volumen) y por consiguiente se detiene el progreso de la grieta por las fuerzas de compresi&oacute;n.<sup>6</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Recientes estudios han demostrado que las superficies de zirconia acumulan menos bacterias que el titanio comercial puro.<sup>7</sup> Otras investigaciones han evaluado la resistencia a la fractura de aditamentos totalmente cer&aacute;micos (Al<sub>2</sub>O<sub>3</sub> y ZrO<sub>2</sub>). La resistencia de ambos aditamentos excede los m&aacute;ximos valores establecidos para carga incisal reportados en la literatura. Sin embargo, los aditamentos de zirconia fueron dos veces m&aacute;s resistentes que Al<sub>2</sub>O<sub>3</sub>.<sup>8</sup> Tambi&eacute;n se ha demostrado en diversos estudios la alta biocompatibilidad tisular y buena tolerancia del ZrO<sub>2</sub> despu&eacute;s de su colocaci&oacute;n subcut&aacute;nea por un periodo de seis a doce meses.<sup>9</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Las restauraciones de diente &uacute;nico son la indicaci&oacute;n m&aacute;s com&uacute;n para los modernos materiales cer&aacute;micos, pero esto debe ser complementado con el incremento en el uso de implantes dentales y m&uacute;ltiples unidades de pr&oacute;tesis fija.<sup>10</sup> Los materiales de elecci&oacute;n actuales para tratamientos sobre implantes incluyen las aleaciones de titanio (titanio), cer&aacute;mica de &oacute;xido de aluminio densamente sinterizada (al&uacute;mina), y cer&aacute;mica de &oacute;xido de zirconia sinterizada (zirconia).<sup>11</sup> En 1993, el primer componente totalmente cer&aacute;mico fue introducido como una alternativa al com&uacute;nmente usado aditamento de titanio como resultado del incremento en las demandas est&eacute;ticas de restauraciones sobre implantes.<sup>12</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">En implantolog&iacute;a, varios estudios han demostrado la aplicaci&oacute;n exitosa de cer&aacute;mica y titanio para la elaboraci&oacute;n de aditamentos; &eacute;stos guardan una gran estabilidad y biocompatibilidad. A pesar de una resistencia a la fractura superior de coronas metal&#45;cer&aacute;mica cementadas sobre aditamentos de titanio comparado con coronas totalmente cer&aacute;micas y cementadas sobre aditamentos cer&aacute;micos, el uso de materiales totalmente cer&aacute;micos se ha incrementado.<sup>13</sup> Los aditamentos cer&aacute;micos tienen un excelente potencial est&eacute;tico cuando su elaboraci&oacute;n es meticulosa, y ofrecen estabilidad a largo plazo.<sup>14</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Actualmente, un material para la fabricaci&oacute;n de estructuras y aditamentos para implantes es la cer&aacute;mica de &oacute;xido de zirconia (ZrO<sub>2</sub>).<sup>15</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">En la elaboraci&oacute;n de las superestructuras son un requisito indispensable la exactitud y la precisi&oacute;n para el &eacute;xito a largo plazo de restauraciones retenidas sobre implantes.<sup>16</sup> Actualmente, un prometedor e interesante material para confeccionar estructuras y aditamentos es la cer&aacute;mica de ZrO<sub>2</sub>, y el di&oacute;xido de zirconia tetragonal estabilizado con itrio (Y&#45;TZP) es un material cer&aacute;mico que puede ser aplicado en cualquier &aacute;rea de la cavidad oral. Sin embargo, los datos cl&iacute;nicos a largo plazo no han sido a&uacute;n evaluados.<sup>17</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Este art&iacute;culo ilustra la utilizaci&oacute;n de &oacute;xido de zirconia (ZrO<sub>2</sub>) como opci&oacute;n para la fabricaci&oacute;n de estructuras para restauraciones sobre implantes. El objetivo primario es el ajuste pasivo de la estructura y sellado de la interfase, con el fin de evitar el aflojamiento prematuro de los tornillos durante la funci&oacute;n y proveer estabilidad a largo plazo. Otros factores importantes son la biocompatibilidad y la est&eacute;tica.</font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>PRESENTACI&Oacute;N DEL CASO</b></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Se present&oacute; al Departamento de Implantolog&iacute;a de la Divisi&oacute;n de Estudios de Postgrado e Investigaci&oacute;n de la Facultad de Odontolog&iacute;a de la UNAM una paciente de 66 a&ntilde;os de edad con edentulismo total de maxilar superior y m&uacute;ltiples restauraciones cer&aacute;micas en maxilar inferior <i>(<a href="#f1">Figura 1</a>).</i> El examen cl&iacute;nico y radiogr&aacute;fico revel&oacute; en el maxilar superior elevaci&oacute;n de piso de seno maxilar bilateral y seis implantes osteointegrados (Intra&#45;lock<sup>&reg;</sup> System, Biolok) 4.0 x 13 mm, asintom&aacute;ticos e integrados al tejido &oacute;seo. Los sitios de colocaci&oacute;n corresponden a los caninos, segundos premolares y primeros molares ausentes.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f1"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f1.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2"><b>PLAN DE TRATAMIENTO</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La selecci&oacute;n inicial del tipo de restauraci&oacute;n definitiva no siempre es f&aacute;cil en casos de rehabilitaci&oacute;n completa sobre implantes. La forma de la arcada superior influye en el plan de tratamiento y es el primer factor a analizar en el plan de tratamiento. La forma de la arcada dentaria del paciente viene determinada por la posici&oacute;n final de los dientes en la zona premaxilar.<sup>18</sup> Las tres formas t&iacute;picas de arcada son: cuadrangular, ovoide y triangular. En las arcadas cuadrangulares, como es el caso, los incisivos centrales y laterales crean s&oacute;lo un peque&ntilde;o voladizo hacia vestibular; en los implantes de caninos se puede reducir el movimiento excursivo de la mand&iacute;bula y las fuerzas oclusales. Como resultado, los implantes de los caninos pueden bastar, sobre todo si se ferulizan con otros implantes posteriores.<sup>19</sup> Seg&uacute;n la literatura, las pr&oacute;tesis completas fijas del maxilar sujetas por implantes se fabrican con una media de seis implantes, cuyo di&aacute;metro es est&aacute;ndar.<sup>20</sup> Otro factor importante en el plan de tratamiento es la relaci&oacute;n entre los planos vertical y horizontal. El espacio que ocupa la altura de una corona en una zona desdentada var&iacute;a notablemente. Si es superior a 15 mm indica que hay p&eacute;rdida vertical de hueso alveolar y tejido blando, esto implica un problema para las restauraciones fijas. Los dientes artificiales son alargados y es necesario a&ntilde;adir tono gingival en zonas est&eacute;ticas. Cuanto m&aacute;s largo es el espacio, mayor impacto sobre los implantes y m&aacute;s aumentar&aacute; el momento de fuerza, y por lo tanto mayor riesgo de fractura.<sup>21</sup> Con base en los datos anteriores se decide realizar una pr&oacute;tesis fija superior con seis implantes, superestructura en zirconia y coronas cementadas sobre la misma.</font></p>  	    <p align="justify"><font face="verdana" size="2">La primera fase del tratamiento incluy&oacute; la toma de impresiones con polivinilsiloxano (Elite HD, Zhermack Spa), utilizaci&oacute;n de <i>copings</i> de impresi&oacute;n (Intra&#45;lock<sup>&reg;</sup> System, Biolok) est&aacute;ndar, y cucharilla de impresi&oacute;n acr&iacute;lica. Los modelos fueron montados en articulador semiajustable y analizados en cuanto a la posici&oacute;n y la distancia interoclusal. Fue elaborada una dentadura completa superior provisional con: tama&ntilde;o, forma, contornos dentarios deseables y se estableci&oacute; la funci&oacute;n oclusal <i>(<a href="#f2">Figura 2</a>).</i> La pr&oacute;tesis provisional fue atornillada a los implantes mediante aditamentos provisionales (Intra&#45;lock<sup>&reg;</sup> System, Biolok), sumergidos en la dentadura acr&iacute;lica.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f2"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f2.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>ESTRUCTURA DE ZIRCONIA</b></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La obtenci&oacute;n del modelo maestro se realiz&oacute; mediante t&eacute;cnica a cucharilla abierta y uniendo con resina acr&iacute;lica Duralay (Reliance Dental Mfg.) los <i>copings</i> de impresi&oacute;n previamente unidos y seccionados para reducir la distorsi&oacute;n.<sup>22</sup> El modelo maestro fue montado en articulador semiajustable (Hanau Modular 190, Teledyne Water Pik Ft. Collins USA) asegurando una apropiada dimensi&oacute;n vertical. Se obtuvo de la pr&oacute;tesis provisional una matriz para la posici&oacute;n, forma y tama&ntilde;o dental adecuado y elaboraci&oacute;n de la estructura de zirconia en el fresado de las preparaciones para coronas.<sup>23</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">A continuaci&oacute;n se obtuvo la estructura en resina acr&iacute;lica autopolimerizable (Pattern Resin, GC) con los aditamentos tipo UCLA sumergidos en ella, y se lleva al paciente para la verificaci&oacute;n de pasividad <i>(<a href="#f3">Figura 3</a>).</i> Posteriormente posicionamos la estructura en la placa de resina de sistema Zirkonzahn<sup>&reg;</sup> que se coloca en el plato derecho de la fresadora y dispondremos en el plato izquierdo el bloque de zirconio correspondiente. Es fresado el volumen completo de la rehabilitaci&oacute;n, incluyendo las bases c&oacute;nicas de los implantes.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f3"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f3.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Para fresar las salidas de los implantes debemos conseguir que &eacute;stas sean paralelas a la fresa de corte. Esto obliga a la rotaci&oacute;n del modelado a la derecha o izquierda para conseguir ese paralelismo <i>(<a href="#f4">Figura 4</a>).</i></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f4"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f4.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Una vez fresada procedemos a retirarla de su soporte. En este momento se puede detallar con fresas de tungsteno a bajas revoluciones. Logrado esto se sinteriza durante seis horas a 1,600 <sup>o</sup>C, donde reducir&aacute; su tama&ntilde;o en un 25%, consiguiendo as&iacute; todas las propiedades de la zirconia sinterizada.</font></p>  	    <p align="justify"><font face="verdana" size="2">Obtenida la estructura verificamos la pasividad de la restauraci&oacute;n; gracias al elevado punto de fusi&oacute;n de este material, ya no tendremos que preocuparnos por las cocciones cer&aacute;micas.</font></p>  	    <p align="justify"><font face="verdana" size="2">Despu&eacute;s, procedemos a realizar los n&uacute;cleos de las restauraciones finales tambi&eacute;n en zirconia; sobre &eacute;stas se coloca de inicio una peque&ntilde;a capa de <i>wash</i> uniforme de cer&aacute;mica, elevamos la temperatura del horno 20&#45;30<sup>o</sup> por encima de la temperatura de cocci&oacute;n de la dentina y esto mejora la uni&oacute;n entre la zirconia y la cer&aacute;mica.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Las coronas y la caracterizaci&oacute;n de tejido blando se terminan con el montaje cer&aacute;mico (Ice Zirkon Keramik) <i>(<a href="#f5">Figura 5</a>).</i> La morfolog&iacute;a coronaria, posici&oacute;n vestibular y la est&eacute;tica se basan en la pr&oacute;tesis provisional que sirve como matriz para la elaboraci&oacute;n de la restauraci&oacute;n definitiva.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f5"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f5.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Finalmente, la restauraci&oacute;n queda constituida por una estructura de &oacute;xido de zirconia con seis aditamentos UCLA incorporados a &eacute;sta, doce preparaciones para coronas completas y las coronas correspondientes fabricadas en &oacute;xido de zirconia y cer&aacute;mica (Ice Zirkon Keramik).</font></p>  	    <p align="justify"><font face="verdana" size="2">La inserci&oacute;n de la restauraci&oacute;n consisti&oacute; en confirmar el sellado de los aditamentos sobre la plataforma de los implantes usando radiograf&iacute;as, aplicar un torque a los tornillos de 35 Ncm, obliteraci&oacute;n del acceso del tornillo y cementaci&oacute;n de las coronas utilizando cemento de ion&oacute;mero de vidrio <i>(<a href="#f6">Figura</a></i> <a href="#f6">6</a>).<sup>24</sup></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f6"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rom/v19n1/a7f6.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>DISCUSI&Oacute;N</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Las situaciones cl&iacute;nicas complejas requieren un meticuloso plan de tratamiento. El dise&ntilde;o de la restauraci&oacute;n definitiva debe seguir requerimientos b&aacute;sicos para la restauraci&oacute;n como son la funci&oacute;n, fon&eacute;tica y est&eacute;tica, as&iacute; como los materiales apropiados.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">El &oacute;xido de zirconio (ZrO<sub>2</sub>) se presenta en la literatura como un material cer&aacute;mico con adecuadas propiedades mec&aacute;nicas para el uso prot&eacute;sico en odontolog&iacute;a.</font></p>  	    <p align="justify"><font face="verdana" size="2">En el &aacute;rea de la implantolog&iacute;a, desde 1993 que se presenta el primer aditamento cer&aacute;mico hasta la fecha, el uso de (ZrO<sub>2</sub>) va en aumento. Ahora la zirconia tiene un campo de aplicaci&oacute;n para pr&oacute;tesis parcial fija soportada por dientes o implantes. Restauraciones &uacute;nicas y parciales fijas con un p&oacute;ntico son posibles en el sector anterior y posterior porque las condiciones mec&aacute;nicas del material lo permiten.<sup>25</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">La extensi&oacute;n de la pr&oacute;tesis parcial fija usando ZrO<sub>2</sub> no es una limitaci&oacute;n hoy en d&iacute;a; se han reportado restauraciones de hasta cinco unidades.<sup>26</sup> Sin embargo, la viabilidad de pr&oacute;tesis de extensi&oacute;n de arcada completa necesita investigaci&oacute;n que soporte su utilizaci&oacute;n.<sup>27</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>CONCLUSIONES</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La zirconia presenta biocompatibilidad, buenas propiedades mec&aacute;nicas y contabilidad en el sellado de restauraciones para el uso odontol&oacute;gico.</font></p>  	    <p align="justify"><font face="verdana" size="2">Las evaluaciones cl&iacute;nicas a largo plazo son un requerimiento indispensable para el uso de zirconia en estructuras de arcadas completas para implantes.</font></p>  	    <p align="justify"><font face="verdana" size="2">La selecci&oacute;n adecuada del paciente, y la combinaci&oacute;n adecuada de protocolos cl&iacute;nicos y t&eacute;cnicos son imperativos para obtener buenos resultados en este tipo de restauraciones.</font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>REFERENCIAS</b></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">1.&nbsp;Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. <i>Biomaterials.</i> 1999; 20: 1&#45;25.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954825&pid=S1870-199X201500010000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">2.&nbsp;Garvie RC, Hannink RH, Pascoe RT. Ceramic steel? <i>Nature.</i> 1975; 258: 703&#45;704.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954827&pid=S1870-199X201500010000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">3.&nbsp;McLaren EA, Giordano RA. Zirconia&#45;based ceramics: material properties, esthetics and layering techniques of a new veneering porcelain, VM9. <i>Quintessence of Dental Technology.</i> 2005; 28: 99&#45;112.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954829&pid=S1870-199X201500010000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">4.&nbsp;Manicone PF, Rossi I, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. <i>J Dent.</i> 2007; 35 (11): 819&#45;826.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954831&pid=S1870-199X201500010000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">5.&nbsp;Tinschert J, Natt G, Mautsch W. Fracture resistance of lithium disilicate, alumina and zirconio based three unit fixed partial dentures: a laboratory study. <i>Internacional Journal of Prosthodontic.</i> 2001; 14: 231&#45;238.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954833&pid=S1870-199X201500010000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">6.&nbsp;Balmes XB. Zirconio, la respuesta. <i>Dental Dialogue.</i> 2006; 3: 56&#45;63.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954835&pid=S1870-199X201500010000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">7.&nbsp;Rimondini L, Cerroni L. Bacterial colonization of zirconia ceramic surfaces: an <i>in vitro</i> and <i>in vivo</i> study. <i>Int J Oral Maxillofac Implants.</i> 2002; 17: 793&#45;798.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954837&pid=S1870-199X201500010000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">8.&nbsp;Yildirim M, Fischer H, Marx R, Edelhoff D. <i>In vivo</i> fracture resistance of implant&#45;supported all&#45;ceramic restorations. <i>Prosthet</i> <i>Dent.</i> 2003; 90: 325&#45;331.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954839&pid=S1870-199X201500010000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">9.&nbsp;Ichikawa Y, Akagawa Y. Tissue compatibility and stability of a new zirconia ceramic <i>in vivo. J Prosthet Dent.</i> 1992; 68: 322&#45;326.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954841&pid=S1870-199X201500010000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">10.&nbsp;Polack MA. Restoration of maxillary incisors with a zirconia all&#45;ceramic system: a case report. <i>Quintessence Int.</i> 2006; 37: 375&#45;380.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954843&pid=S1870-199X201500010000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">11.&nbsp;Sadam A, Blatz MB, Lang B. Clinical considerations for densely sintered alumina and zirconio restorations: part 2. <i>Int J Periodontics Restorative Dent.</i> 2005; 25: 343&#45;349.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954845&pid=S1870-199X201500010000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">12.&nbsp;Henriksson K, Jemt T. Evaluation of custom&#45;made procera ceramic abutments for single&#45;implant tooth replacement: a prospective 1&#45;year follow&#45;up study. <i>Int J Prosthodont.</i> 2003; 16: 626&#45;630.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954847&pid=S1870-199X201500010000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">13.&nbsp;Van Dooren E. Using zirconia in esthetic implant restorations. <i>Quintessence Dent Technol.</i> 2007; 30: 119&#45;128.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954849&pid=S1870-199X201500010000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">14.&nbsp;Sadoun M, Perelmuter S. Alumina&#45;zirconia machinable abutments for implant supported single tooth anterior crowns. <i>The Implant Report.</i> 1997; 9: 1047&#45;1053.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954851&pid=S1870-199X201500010000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">15.&nbsp;Holst S, Bergler M, Steger E. The application of zirconium oxide frameworks for implant superstructures. <i>Quintessence Dent Te</i><i>chnol.</i> 2006; 29: 103&#45;112.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954853&pid=S1870-199X201500010000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">16.&nbsp;Wittkowski S. CAD/CAM in dental technology. <i>Quintessence</i> <i>Dent Technol.</i> 2005; 28: 169&#45;184.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954855&pid=S1870-199X201500010000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">17.&nbsp;Raigrodski AJ. Contemporary materials and technologies for all&#45;ceramic fixed partial dentures: a review of the literature. <i>J</i> <i>Prosthet Dent.</i> 2004; 92: 557&#45;562.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954857&pid=S1870-199X201500010000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">18.&nbsp;Misch CE. <i>Pr&oacute;tesis dental sobre implantes.</i> Espa&ntilde;a: Elsevier; 2006. p. 625.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954859&pid=S1870-199X201500010000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">19.&nbsp;Naert I, Quirynen M. Prosthetic aspects of osseointegrated mixtures supporting overdentures: a 4&#45;year report. <i>J Prosthet Dent.</i> 1991; 65: 671&#45;680.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954861&pid=S1870-199X201500010000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">20.&nbsp;Br&#507;nemark PI, Svensson B. Ten&#45;year survival rates of fixed prostheses on tour or six implants ad modum Br&#507;nemark in full edentulism. <i>Clin Oral Implants Res.</i> 1995; 6: 227&#45;231.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954863&pid=S1870-199X201500010000700020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">21.&nbsp;Benzina UR, Gail H, Weberr H. Biomechanical aspects of 2 different implant&#45;prosthetic concepts for the edentulous maxilla. <i>Int J Oral Maxillofac Implants.</i> 1995; 10: 188&#45;198.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954865&pid=S1870-199X201500010000700021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">22.&nbsp;Hsu C, Millstein PL, Sheldon RS. A comparative analysis of the accuracy of implant transfer techniques. <i>J Prosthet Dent.</i> 1993; 69: 588&#45;593.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954867&pid=S1870-199X201500010000700022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">23.&nbsp;Morr T. Transfer of information for esthetic and functional predictability in severe wear cases. <i>Quintessence Dent Technol.</i> 2007; 30: 55&#45;65.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954869&pid=S1870-199X201500010000700023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">24.&nbsp;Mitrani R, Duran R. Zirconium oxide CAD/CAM generated restaurations: an esencial option in contemporary restorative dentistry. <i>Quintessence Dent Technol.</i> 2007; 30: 66&#45;76.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954871&pid=S1870-199X201500010000700024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">25.&nbsp;Studart AR, Filser F, Kocher P. Fatigue of zirconia under cyclic loading in water and its implications for the desing of dental bridges. <i>Dental Materials.</i> 2007; 23: 106&#45;114.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954873&pid=S1870-199X201500010000700025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">26.&nbsp;Larsson C, Vult von Steyern P. All ceramic two&#45;to five&#45;unit implant&#45;supported reconstructions. A randomized, prospective clinical trial. <i>Swedish Dental Journal.</i> 2006; 30: 45&#45;53.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954875&pid=S1870-199X201500010000700026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">27.&nbsp;Holst S, Bergler M, Steger E. The application of zirconium oxide frameworks for implant superstructures. <i>Quintessence Dent Te</i><i>chnol.</i> 2006; 29: 103&#45;112.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8954877&pid=S1870-199X201500010000700027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><a name="n1a"></a><a href="#n1b"><img src="/img/revistas/rom/v19n1/flecha.jpg"></a>Direcci&oacute;n para correspondencia:    <br> 	<b>Jorge Pimentel Hern&aacute;ndez</b>    <br> 	E&#45;mail: <a href="mailto:jorgyph@hotmail.com">jorgyph@hotmail.com</a></font></p>  	    <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Nota</b></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Este art&iacute;culo puede ser consultado en versi&oacute;n completa en <a href="http://www.medigraphic.com/facultadodontologiaunam" target="_blank">http://www.medigraphic.com/facultadodontologiaunam</a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Piconi]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Maccauro]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Zirconia as a ceramic biomaterial]]></article-title>
<source><![CDATA[Biomaterials]]></source>
<year>1999</year>
<volume>20</volume>
<page-range>1-25</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garvie]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
<name>
<surname><![CDATA[Hannink]]></surname>
<given-names><![CDATA[RH]]></given-names>
</name>
<name>
<surname><![CDATA[Pascoe]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ceramic steel?]]></article-title>
<source><![CDATA[Nature]]></source>
<year>1975</year>
<volume>258</volume>
<page-range>703-704</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McLaren]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
<name>
<surname><![CDATA[Giordano]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Zirconia-based ceramics: material properties, esthetics and layering techniques of a new veneering porcelain, VM9]]></article-title>
<source><![CDATA[Quintessence of Dental Technology]]></source>
<year>2005</year>
<volume>28</volume>
<page-range>99-112</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Manicone]]></surname>
<given-names><![CDATA[PF]]></given-names>
</name>
<name>
<surname><![CDATA[Rossi]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Raffaelli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An overview of zirconia ceramics: basic properties and clinical applications]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2007</year>
<volume>35</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>819-826</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tinschert]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Natt]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Mautsch]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fracture resistance of lithium disilicate, alumina and zirconio based three unit fixed partial dentures: a laboratory study]]></article-title>
<source><![CDATA[Internacional Journal of Prosthodontic]]></source>
<year>2001</year>
<volume>14</volume>
<page-range>231-238</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balmes]]></surname>
<given-names><![CDATA[XB]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Zirconio, la respuesta]]></article-title>
<source><![CDATA[Dental Dialogue]]></source>
<year>2006</year>
<volume>3</volume>
<page-range>56-63</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rimondini]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cerroni]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>2002</year>
<volume>17</volume>
<page-range>793-798</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yildirim]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fischer]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Marx]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Edelhoff]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo fracture resistance of implant-supported all-ceramic restorations]]></article-title>
<source><![CDATA[Prosthet Dent]]></source>
<year>2003</year>
<volume>90</volume>
<page-range>325-331</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ichikawa]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Akagawa]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tissue compatibility and stability of a new zirconia ceramic in vivo]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1992</year>
<volume>68</volume>
<page-range>322-326</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Polack]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Restoration of maxillary incisors with a zirconia all-ceramic system: a case report]]></article-title>
<source><![CDATA[Quintessence Int]]></source>
<year>2006</year>
<volume>37</volume>
<page-range>375-380</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sadam]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Blatz]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical considerations for densely sintered alumina and zirconio restorations: part 2]]></article-title>
<source><![CDATA[Int J Periodontics Restorative Dent]]></source>
<year>2005</year>
<volume>25</volume>
<page-range>343-349</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Henriksson]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Jemt]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of custom-made procera ceramic abutments for single-implant tooth replacement: a prospective 1-year follow-up study]]></article-title>
<source><![CDATA[Int J Prosthodont]]></source>
<year>2003</year>
<volume>16</volume>
<page-range>626-630</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van Dooren]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Using zirconia in esthetic implant restorations]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2007</year>
<volume>30</volume>
<page-range>119-128</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sadoun]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Perelmuter]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alumina-zirconia machinable abutments for implant supported single tooth anterior crowns]]></article-title>
<source><![CDATA[The Implant Report]]></source>
<year>1997</year>
<volume>9</volume>
<page-range>1047-1053</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holst]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bergler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Steger]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The application of zirconium oxide frameworks for implant superstructures]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>103-112</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wittkowski]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[CAD/CAM in dental technology]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2005</year>
<volume>28</volume>
<page-range>169-184</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raigrodski]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2004</year>
<volume>92</volume>
<page-range>557-562</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Misch]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
</person-group>
<source><![CDATA[Prótesis dental sobre implantes]]></source>
<year>2006</year>
<page-range>625</page-range><publisher-name><![CDATA[Elsevier]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Naert]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Quirynen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prosthetic aspects of osseointegrated mixtures supporting overdentures: a 4-year report]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1991</year>
<volume>65</volume>
<page-range>671-680</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Br&#507;nemark]]></surname>
<given-names><![CDATA[PI]]></given-names>
</name>
<name>
<surname><![CDATA[Svensson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ten-year survival rates of fixed prostheses on tour or six implants ad modum Br&#507;nemark in full edentulism]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1995</year>
<volume>6</volume>
<page-range>227-231</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Benzina]]></surname>
<given-names><![CDATA[UR]]></given-names>
</name>
<name>
<surname><![CDATA[Gail]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Weberr]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomechanical aspects of 2 different implant-prosthetic concepts for the edentulous maxilla]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Implants]]></source>
<year>1995</year>
<volume>10</volume>
<page-range>188-198</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hsu]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Millstein]]></surname>
<given-names><![CDATA[PL]]></given-names>
</name>
<name>
<surname><![CDATA[Sheldon]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative analysis of the accuracy of implant transfer techniques]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>1993</year>
<volume>69</volume>
<page-range>588-593</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morr]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Transfer of information for esthetic and functional predictability in severe wear cases]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2007</year>
<volume>30</volume>
<page-range>55-65</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mitrani]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Duran]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Zirconium oxide CAD/CAM generated restaurations: an esencial option in contemporary restorative dentistry]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2007</year>
<volume>30</volume>
<page-range>66-76</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Studart]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Filser]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kocher]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fatigue of zirconia under cyclic loading in water and its implications for the desing of dental bridges]]></article-title>
<source><![CDATA[Dental Materials]]></source>
<year>2007</year>
<volume>23</volume>
<page-range>106-114</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Larsson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Vult von Steyern]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[All ceramic two-to five-unit implant-supported reconstructions: A randomized, prospective clinical trial]]></article-title>
<source><![CDATA[Swedish Dental Journal]]></source>
<year>2006</year>
<volume>30</volume>
<page-range>45-53</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holst]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Bergler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Steger]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The application of zirconium oxide frameworks for implant superstructures]]></article-title>
<source><![CDATA[Quintessence Dent Technol]]></source>
<year>2006</year>
<volume>29</volume>
<page-range>103-112</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
