<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1870-0195</journal-id>
<journal-title><![CDATA[Revista mexicana de ciencias farmacéuticas]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. cienc. farm]]></abbrev-journal-title>
<issn>1870-0195</issn>
<publisher>
<publisher-name><![CDATA[Asociación Farmacéutica Mexicana A.C.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1870-01952011000100006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Desarrollo y validación de un método analítico por cromatografía de líquidos de alta resolución para la determinación de indometacina en crema]]></article-title>
<article-title xml:lang="en"><![CDATA[Development and validation of an analytical method by high performance liquid chromatography for determination of indomethacin in cream]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vázquez R.]]></surname>
<given-names><![CDATA[María Luisa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández L.]]></surname>
<given-names><![CDATA[Alejandra]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Retchkiman C.]]></surname>
<given-names><![CDATA[Berta]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Autónoma Metropolitana-Xochimilco Departamento de Sistemas Biológicos ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2011</year>
</pub-date>
<volume>42</volume>
<numero>1</numero>
<fpage>45</fpage>
<lpage>51</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1870-01952011000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1870-01952011000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1870-01952011000100006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se desarrolló un método analítico rápido y sencillo por Cromatografía de Líquidos de Alta Resolución (CLAR) con detección UV para la determinación de indometacina en crema al 2.5%. Se probaron diferentes condiciones para la cuantificación, encontrando mejores resultados con una columna L, (Supelcosil LC18, 250 mm x 4.6 mm, 5 &#956;m), una fase móvil compuesta por metanol y solución amortiguadora de fosfatos pH 7.1 (70:30), una velocidad de flujo de 1.0 mL/min y una longitud de onda de detección de 254 nm. El método es rápido y lineal en un intervalo de concentraciones de 10 a 50 &#956;g/mL (r² = 0.999), exacto (IC 100.32±4.5%) y preciso (CV< 1.5%) resultando adecuado para la cuantificación del fármaco como método de control de calidad.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[An easy, quick and completely automatizated analytical method was developed by High Performance Liquid Chromatography (HPLC) with UV detection for quantitative determination of Indomethacin in 2.5% cream. Different conditions for its determination were tested, finding the best conditions using a L column1 (Supelcosil LC18, 250 mm x 4.6 mm, 5 &#956;m), a movil phase with metanol and phosphate buffer pH 7.1 (70:30), flow speed 1.0 mL/min and detection lambda of 254 nm. The method is quick and linear from 10 to 50 &#956;g/mL ((r² = 0.999), accurate (IC 100.32±4.5%) and adequate precision (CV< 1.5%), and it results in an adequate analytical method to quantification of Indomethacin in a quality control test.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[indometacina]]></kwd>
<kwd lng="es"><![CDATA[CLAR]]></kwd>
<kwd lng="es"><![CDATA[ingredientes activos farmacéuticos]]></kwd>
<kwd lng="en"><![CDATA[indomethacin]]></kwd>
<kwd lng="en"><![CDATA[HPLC]]></kwd>
<kwd lng="en"><![CDATA[pharmaceuticals]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="justify"><font face="verdana" size="4">Trabajos cient&iacute;ficos</font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="4"><b>Desarrollo y validaci&oacute;n de un m&eacute;todo anal&iacute;tico por cromatograf&iacute;a de l&iacute;quidos de alta resoluci&oacute;n para la determinaci&oacute;n de indometacina en crema</b></font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="3"><b>Development and validation of an analytical method by high performance liquid chromatography for determination of indomethacin in cream</b></font></p>  	    <p>&nbsp;</p>  	    <p align="center"><font face="verdana" size="2"><b>Mar&iacute;a Luisa V&aacute;zquez R., Alejandra Hern&aacute;ndez L., Berta Retchkiman C.</b></font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><i> Departamento de Sistemas Biol&oacute;gicos, Universidad Aut&oacute;noma Metropolitana&#45;Xochimilco</i></font></p>  	    ]]></body>
<body><![CDATA[<p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Correspondencia:</b></font></p>  	    <p align="justify"><font face="verdana" size="2"><i>M en C Ma. Luisa V&aacute;zquez R.    <br> Departamento de Sistemas Biol&oacute;gicos    <br> Universidad Aut&oacute;noma Metropolitana&#45;Xochimilco    <br> Calzada del Hueso 1100, Colonia Villa Quietud    <br> Delegaci&oacute;n Coyoac&aacute;n C.P. 04960, M&eacute;xico D.F., M&eacute;xico    <br> Tel. 5483 7511 Fax 5483 7511, 5483 7237     <br> e&#45;mail:</i> <a href="mailto:lramirez@correo.xoc.uam.mx">lramirez@correo.xoc.uam.mx</a></font></p>     <p>&nbsp;</p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Fecha de recepci&oacute;n: 11 de noviembre de 2010.    <br> 	Fecha de recepci&oacute;n de modificaci&oacute;n: 7 de febrero de 2011.    <br> 	Fecha de aceptaci&oacute;n: 21 de febrero de 2011.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Se desarroll&oacute; un m&eacute;todo anal&iacute;tico r&aacute;pido y sencillo por Cromatograf&iacute;a de L&iacute;quidos de Alta Resoluci&oacute;n (CLAR) con detecci&oacute;n UV para la determinaci&oacute;n de indometacina en crema al 2.5%. Se probaron diferentes condiciones para la cuantificaci&oacute;n, encontrando mejores resultados con una columna L, (Supelcosil LC<sub>18</sub>, 250 mm x 4.6 mm, 5 &#956;m), una fase m&oacute;vil compuesta por metanol y soluci&oacute;n amortiguadora de fosfatos pH 7.1 (70:30), una velocidad de flujo de 1.0 mL/min y una longitud de onda de detecci&oacute;n de 254 nm. El m&eacute;todo es r&aacute;pido y lineal en un intervalo de concentraciones de 10 a 50 &#956;g/mL (r<sup>2</sup> = 0.999), exacto (IC 100.32&plusmn;4.5%) y preciso (CV&lt; 1.5%) resultando adecuado para la cuantificaci&oacute;n del f&aacute;rmaco como m&eacute;todo de control de calidad.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> indometacina, CLAR, ingredientes activos farmac&eacute;uticos.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>  	    <p align="justify"><font face="verdana" size="2">An easy, quick and completely automatizated analytical method was developed by High Performance Liquid Chromatography (HPLC) with UV detection for quantitative determination of Indomethacin in 2.5% cream. Different conditions for its determination were tested, finding the best conditions using a L column<sub>1</sub> (Supelcosil LC18, 250 mm x 4.6 mm, 5 &#956;m), a movil phase with metanol and phosphate buffer pH 7.1 (70:30), flow speed 1.0 mL/min and detection lambda of 254 nm. The method is quick and linear from 10 to 50 &#956;g/mL ((r<sup>2</sup> = 0.999), accurate (IC 100.32&plusmn;4.5%) and adequate precision (CV&lt; 1.5%), and it results in an adequate analytical method to quantification of Indomethacin in a quality control test.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Key words:</b> indomethacin, HPLC, pharmaceuticals.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La indometacina &#91;&Aacute;cido 1&#45;(4&#45;clorobenzoil)&#45;2&#45;metil&#45;5metoxi&#45;1H&#45;indol&#45;3&#45;ac&eacute;tico&#93; &#45;metilindol&#45;3&#45;il&#93; ac&eacute;tico; &Aacute;cido (1&#45;(4&#45;clorbenzoil)&#45;5&#45;metoxi&#45;2&#45;metilindo&#45;3&#45;leacetico)&#93; es un antiinflamatorio no esteroideo, analg&eacute;sico y antipir&eacute;tico. Su efecto se basa en la inhibici&oacute;n de la s&iacute;ntesis de prostaglandinas en tejidos perif&eacute;ricos y a la inhibici&oacute;n de la migraci&oacute;n leucocitaria a las &aacute;reas inflamadas. Se usa frecuentemente en el tratamiento de los s&iacute;ntomas de la artritis reumatoide, osteoartritis y espondilitis anquilosante. La v&iacute;a de administraci&oacute;n usualmente es oral, pero puede administrarse por v&iacute;a intravenosa, v&iacute;a rectal o t&oacute;pica<sup>1</sup>.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se han utilizado una gran variedad de t&eacute;cnicas anal&iacute;ticas para la cuantificaci&oacute;n de indometacina como materia prima y en preparaciones farmac&eacute;uticas principalmente tabletas y c&aacute;psulas, por ejemplo, titulaciones &aacute;cido&#45;base<sup>2</sup>, espectrofotometr&iacute;a<sup>3&#45;5</sup>, espectrofluorometr&iacute;a<sup>6</sup>, electroforesis capilar<sup>7</sup>, densitometr&iacute;a<sup>8</sup> y cromatograf&iacute;a de l&iacute;quidos de alta resoluci&oacute;n (CLAR).<sup>9&#45;14</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">En la mayor&iacute;a de los m&eacute;todos publicados para cuantificar indometacina en plasma tambi&eacute;n se determina por CLAR.<sup>15&#45;18</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">La metodolog&iacute;a anal&iacute;tica de la FEUM 9<sup>a</sup> edici&oacute;n<sup>19</sup>, incluye en sus monograf&iacute;as el an&aacute;lisis por CLAR, para indometacina materia prima y un m&eacute;todo por espectrofotometr&iacute;a UV, para la determinaci&oacute;n de indometacina en tabletas utilizando cloruro de metileno como disolvente final.</font></p>  	    <p align="justify"><font face="verdana" size="2">La valoraci&oacute;n de la suspensi&oacute;n de indometacina se lleva a cabo con un procedimiento de extracci&oacute;n utilizando una mezcla de agua y &eacute;ter, posteriormente, se disuelve una al&iacute;cuota de la fase et&eacute;rea, en una mezcla de metanol:&aacute;cido ac&eacute;tico glacial (99:1) determinando la absorbancia de la soluci&oacute;n a 320 nm.</font></p>  	    <p align="justify"><font face="verdana" size="2">La USP 32<sup>20</sup> recomienda un m&eacute;todo por CLAR para indometacina materia prima utilizando una columna anal&iacute;tica conteniendo empaque L1 (4mm x 30cm, 10 &#956;m). La cuantificaci&oacute;n de indometacina en c&aacute;psulas y supositorios se determina por un m&eacute;todo espectrofotom&eacute;trico a 320 nm con cloruro de metileno como disolvente. Para las c&aacute;psulas de liberaci&oacute;n extendida y la suspensi&oacute;n de indometacina se utiliza un m&eacute;todo por CLAR con una columna L1. Las muestras se disuelven en &aacute;cido fosf&oacute;rico diluido utilizando un sonicador, para ser inyectadas posteriormente en el cromat&oacute;grafo.</font></p>  	    <p align="justify"><font face="verdana" size="2">En diversos art&iacute;culos cient&iacute;ficos se ha reportado metodolog&iacute;a anal&iacute;tica por CLAR para la determinaci&oacute;n de indometacina con detecci&oacute;n ultravioleta. Khuhawar y col. desarrollaron un m&eacute;todo para cuantificar isoniazida y pirazinamida en tabletas e indometacina en c&aacute;psulas. La columna utilizada es YMC&#45;ODS (150mm x 4.6 mm d.i), con una fase m&oacute;vil agua:metanol:tetrahidrofurano (59:39:2) y una velocidad de flujo de 2 mL/min a una longitud de onda de 328 nm. El rango de concentraciones estudiadas fue de 10.7 a 64.08 &#956;g/mL.<sup>11</sup></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Para la cuantificaci&oacute;n de indometacina en gel por CLAR Nov&aacute;kov&aacute; y colaboradores utilizaron varias columnas para el desarrollo de este m&eacute;todo, siendo la mejor Zorbax SB&#45;Phenyl (75 mm x 4.6 mm, 3.5 &#956;m) con la cual se eliminaban las interferencias del placebo, una fase m&oacute;vil compuesta de acetonitrilo:&aacute;cido fosf&oacute;rico 0.2% (50:50) y una velocidad de flujo de 1.2 mL/min utilizando para la determinaci&oacute;n una longitud de onda de 237 nm.<sup>10</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">El desarrollo de la na notecnolog&iacute;a implica la formaci&oacute;n de part&iacute;culas lip&iacute;dicas s&oacute;lidas de tama&ntilde;o nanosc&oacute;pico que contienen al f&aacute;rmaco de inter&eacute;s, para mejorar las propiedades de solubilidad e incrementar el &aacute;rea superficial efectiva, entre otros aspectos, lo que las convierte en una excelente alternativa a sistemas de liberaci&oacute;n como emulsiones y liposomas.<sup>21</sup> Estos sistemas de liberaci&oacute;n ahora se enfrentan al reto, de desarrollar conjuntamente ensayos validados que permitan detectar y cuantificar el f&aacute;rmaco contenido en las nanopart&iacute;culas en productos terminados.<sup>22,23</sup></font></p>  	    <p align="justify"><font face="verdana" size="2">Para el caso espec&iacute;fico de Indometacina, el desarrollo de la nanotecnolog&iacute;a ha empleado esta metodolog&iacute;a para elaborar principalmente cremas de aplicaci&oacute;n t&oacute;pica lo que facilita la absorci&oacute;n de la indometacina a trav&eacute;s de la epidermis, sobre todo en los tejidos que rodean las articulaciones donde se requiere la acci&oacute;n del f&aacute;rmaco.</font></p>  	    <p align="justify"><font face="verdana" size="2">Es importante resaltar que aunque existe un gran n&uacute;mero de m&eacute;todos por CLAR para cuantificar indometacina, no existe un m&eacute;todo para su cuantificaci&oacute;n en la forma farmac&eacute;utica de crema (conteniendo nanopart&iacute;culas). Para alcanzar este prop&oacute;sito, en este art&iacute;culo se presenta el desarrollo de un m&eacute;todo por CLAR simple, sencillo y r&aacute;pido para la determinaci&oacute;n de indometacina en este tipo de formas farmac&eacute;uticas.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Material y m&eacute;todo</b></font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Reactivos</b></font></p>  	    <p align="justify"><font face="verdana" size="2">El est&aacute;ndar de referencia de Indometacina fue proporcionado por FEUM. El fosfato monob&aacute;sico de potasio, el fosfato dib&aacute;sico de sodio y el &aacute;cido ortofosf&oacute;rico fueron grado reactivo (Baker). El metanol fue grado cromatogr&aacute;fico (Merck). El agua utilizada fue grado cromatogr&aacute;fico preparada con Direct Q3 Millipore.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Equipo</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Para llevar a cabo todos los an&aacute;lisis se utiliz&oacute; un sistema cromatogr&aacute;fico Perkin Elmer modelo LC&#45;95 equipado con una bomba cuaternaria, un inyector manual y un detector UV/ visible de longitud de onda variable 553. El equipo cuenta con un sistema de inyecci&oacute;n de volumen constante calibrado a 20 &#956;L. La separaci&oacute;n de la indometacina se llev&oacute; a cabo con una columna L<sub>1</sub> (Supelcosil LC18), de 250 mm x 4.6 mm y 5 &#956;m de tama&ntilde;o de part&iacute;cula. Se ten&iacute;a acoplado un integrador Waters 745 Data Module.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Condiciones cromatogr&aacute;ficas</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Se probaron diferentes mezclas para la fase m&oacute;vil, encontrando que la m&aacute;s adecuada fue metanol: soluci&oacute;n amortiguadora de fosfatos pH 7.1, 70:30 con una velocidad de flujo de 1 mL/min y la detecci&oacute;n a una longitud de onda de 254 nm.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Preparaci&oacute;n del est&aacute;ndar y curva est&aacute;ndar</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La soluci&oacute;n del est&aacute;ndar de referencia para el an&aacute;lisis de la crema de indometacina, se prepar&oacute; disolviendo 50 mg de indometacina FEUM en metanol y llevando a un aforo a 100 mL con el mismo disolvente. Posteriormente, se realiz&oacute; una curva de calibraci&oacute;n con un rango de concentraciones de 10 a 50 &#956;g/mL haciendo la diluci&oacute;n final con fase m&oacute;vil.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Preparaci&oacute;n de la muestra</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Se pesaron exactamente 800 mg de crema de indometacina equivalente a 20 mg de principio activo, se le adicion&oacute; 50 mL de metanol y se someti&oacute; a sonicaci&oacute;n por 15 minutos, posteriormente se afor&oacute; a 100 mL con metanol y se filtr&oacute; utilizando un filtro Millipore de 0.45 &#956;m. Las diluciones finales para la curva de calibraci&oacute;n con la muestra se llevaron a cabo con fase m&oacute;vil.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>M&eacute;todo de validaci&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La validaci&oacute;n del m&eacute;todo se realiz&oacute; con base en las gu&iacute;as de ICH y los requerimientos farmac&eacute;uticos de fuente farmacop&eacute;ica. Una parte importante de la validaci&oacute;n, es la adecuabilidad del sistema, para lo cual se calcularon el n&uacute;mero de platos te&oacute;ricos, la asimetr&iacute;a del pico, resoluci&oacute;n y &aacute;rea bajo la curva. Todos los an&aacute;lisis estad&iacute;sticos fueron realizados con el software SPSS versi&oacute;n 19.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Linealidad y precisi&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La linealidad del sistema se determin&oacute; con el coeficiente de correlaci&oacute;n en un rango de concentraciones de 10 a 50 &#956;g/ mL (33.34&#45;166.67%), utilizando cinco curvas de calibraci&oacute;n del est&aacute;ndar disuelto en la fase m&oacute;vil metanol: soluci&oacute;n amortiguadora pH 7.1 (70:30). La precisi&oacute;n del sistema fue evaluada con el coeficiente de variaci&oacute;n utilizando nueve muestras de la concentraci&oacute;n correspondiente al 100%.</font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Para la linealidad del m&eacute;todo se analizaron cinco curvas de calibraci&oacute;n con la crema de indometacina en un intervalo de concentraciones de 10 a 50 &#956;g/mL. Para llevar a cabo el an&aacute;lisis del coeficiente de correlaci&oacute;n y el an&aacute;lisis de varianza de la regresi&oacute;n, la variable de respuesta considerada es el &aacute;rea bajo la curva en funci&oacute;n de la concentraci&oacute;n.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se eval&uacute;a el an&aacute;lisis de regresi&oacute;n para el porcentaje de recuperaci&oacute;n obtenido bajo el tratamiento de las muestras como se ha descrito.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Exactitud y precisi&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La exactitud del m&eacute;todo se determin&oacute; con 30 muestras de crema a tres rangos de concentraci&oacute;n 24, 30 y 36 &#956;g/mL (80,100 y 120 %), comparados contra la concentraci&oacute;n nominal de muestras control.</font></p>  	    <p align="justify"><font face="verdana" size="2">La precisi&oacute;n fue evaluada por el an&aacute;lisis de muestras de diferentes concentraciones en diferentes d&iacute;as de an&aacute;lisis. Y se evalu&oacute; a trav&eacute;s de los resultados globales en todas las pruebas de validaci&oacute;n.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Reproducibilidad</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Se analizaron por triplicado muestras de tres concentraciones conocidas de indometacina crema, en tres d&iacute;as. Se evalu&oacute; la posible diferencia a trav&eacute;s de un an&aacute;lisis de varianza de dos criterios de clasificaci&oacute;n con interacci&oacute;n. Y se reporta el coeficiente de variaci&oacute;n inter&#45;d&iacute;a y general.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Selectividad y l&iacute;mite de detecci&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">La selectividad del m&eacute;todo se verific&oacute; por comparaci&oacute;n de la muestra del preparado farmac&eacute;utico y la soluci&oacute;n est&aacute;ndar. El l&iacute;mite de detecci&oacute;n se determin&oacute; con el m&eacute;todo de promedio se&ntilde;al&#45;ruido.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Estabilidad</b></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La estabilidad de la muestra en refrigeraci&oacute;n a 4 &deg;C fue evaluada por un periodo de 3 meses.</font></p>  	    <p align="justify"><font face="verdana" size="2"><b>Resultados y discusi&oacute;n</b></font></p>  	    <p align="justify"><font face="verdana" size="2">Para la determinaci&oacute;n de la indometacina en crema, se eligi&oacute; CLAR, con detecci&oacute;n por espectrofotometr&iacute;a como un m&eacute;todo sencillo r&aacute;pido y efectivo para la determinaci&oacute;n del principio activo.</font></p>  	    <p align="justify"><font face="verdana" size="2">Se probaron diferentes condiciones para el desarrollo de este m&eacute;todo, utilizando metanol, soluci&oacute;n amortiguadora de fosfatos y acetonitrilo en diferentes combinaciones. La fase m&oacute;vil final fue metanol: fosfatos pH 7.1.</font></p>  	    <p align="justify"><font face="verdana" size="2">El tiempo de retenci&oacute;n obtenido para Indometacina bajo las condiciones descritas fue de 1.78 min para el est&aacute;ndar y 1.77 min para la muestra en la presentaci&oacute;n en crema (<a href="#f1">Figura 1</a>).</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f1"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6f1.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Se lograron obtener valores dentro de las especificaciones para la adecuabilidad del sistema (<a href="#t1">Tabla 1</a>).</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t1"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6t1.jpg"></font></p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La linealidad del sistema fue estimada por an&aacute;lisis de regresi&oacute;n utilizando las cinco curvas de calibraci&oacute;n elaboradas con soluci&oacute;n de est&aacute;ndar en concentraciones de 10 a 50 &#956;g/mL, obteniendo el siguiente modelo ajustado:</font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6e1.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">El cual demostr&oacute; ser significativo (p &lt; 0.0001), con r = 0.9998 y r<sup>2</sup> = 0.9995. Tanto el intercepto como la pendiente son significativamente diferentes de cero (p&lt;0.001 en ambos casos). an&aacute;lisis de varianza mostr&oacute; que el modelo es adecuado para la representaci&oacute;n de los datos, como se muestra en la <a href="#t2">Tabla 2</a> con p &lt; 0.0001. La gr&aacute;fica de valores observados y ajustados se muestra en la <a href="#f2">Figura 2</a>.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t2"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6t2.jpg"></font></p>  	    <p align="center"><font face="verdana" size="2"><a name="f2"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6f2.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">Para la linealidad del m&eacute;todo se analizaron cinco curvas de calibraci&oacute;n con la crema de indometacina en un intervalo de concentraciones de 10 a 50 &#956;g/mL. Se realiz&oacute; la regresi&oacute;n entre la cantidad adicionada y la cantidad recuperada para evaluar el manejo de la muestra y el intervalo de trabajo.</font></p>  	    <p align="justify"><font face="verdana" size="2">Los par&aacute;metros de la regresi&oacute;n se muestran en la <a href="#t3">Tabla 3</a>, y se concluye que el m&eacute;todo es adecuado para el manejo de la muestra ya que el intercepto es estad&iacute;sticamente igual que cero, mientras que la pendiente es estad&iacute;sticamente igual a 1, por lo que la recuperaci&oacute;n de las cantidades agregadas se acerca a 100%. La regresi&oacute;n concluye con un coeficiente de correlaci&oacute;n de 0.9999 y un valor de predicci&oacute;n con 95% de confianza de 0.9999, lo cual es significativo para el modelo de recuperaci&oacute;n de las cantidades agregadas, logrando un m&eacute;todo lineal.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t3"></a></font></p>  	    ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6t3.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">La exactitud fue evaluada en 30 muestras preparadas con cantidades agregadas de 23.95, 30.2045 y 34.82 &#956;g/mL, se obtuvo una media de 100.329 % &plusmn; 1.52% (&plusmn; desviaci&oacute;n est&aacute;ndar), con intervalo de confianza de 99.76% a 100.90%, lo que demuestra que el m&eacute;todo es exacto. Adicionalmente se realiza un an&aacute;lisis de varianza para evaluar la posible diferencia entre concentraciones, el cual se muestra en la <a href="#t4">Tabla 4</a>, y se concluye que no existe diferencia entre concentraciones (p = 0.462), por lo que el m&eacute;todo es exacto para las concentraciones evaluadas.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t4"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6t4.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">La reproducibilidad se estima a trav&eacute;s de un an&aacute;lisis de varianza de dos criterios de clasificaci&oacute;n con interacci&oacute;n al evaluar tres concentraciones diferentes en tres d&iacute;as de an&aacute;lisis. El coeficiente de variaci&oacute;n intrad&iacute;a fue de 1.07%, 1.00% y 1.25%. El coeficiente de variaci&oacute;n global para los datos fue de 1.09%.</font></p>  	    <p align="justify"><font face="verdana" size="2">A trav&eacute;s de un an&aacute;lisis de varianza se estima la posible diferencia entre d&iacute;as y entre concentraciones, que se muestra en la <a href="#t5">Tabla 5</a>. No se encuentran diferencias entre d&iacute;as o entre concentraciones. Igualmente la interacci&oacute;n no fue significativa. La conclusi&oacute;n es que el m&eacute;todo es reproducible.</font></p>  	    <p align="center"><font face="verdana" size="2"><a name="t5"></a></font></p>  	    <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmcf/v42n1/a6t5.jpg"></font></p>  	    <p align="justify"><font face="verdana" size="2">La estabilidad de la muestra se evalu&oacute; en un periodo de tres meses, en una serie de 4 muestras, las cuales se mantuvieron en refrigeraci&oacute;n a 4&deg;C, obteniendo una diferencia de 0.98% &plusmn; 0.13% en el periodo establecido y sin que apareciera ninguna se&ntilde;al adicional en los cromatogramas.</font></p>  	    <p>&nbsp;</p>  	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Conclusiones</b></font></p>  	    <p align="justify"><font face="verdana" size="2">De acuerdo a los criterios de ICH y de las gu&iacute;as de validaci&oacute;n utilizadas, el m&eacute;todo cumple con criterios de sistema y de m&eacute;todo (linealidad, reproducibilidad, exactitud), por lo que se concluye que se logra obtener un m&eacute;todo con precisi&oacute;n adecuada de valores peque&ntilde;os de coeficientes de variaci&oacute;n y con t&eacute;rminos independientes en d&iacute;as de an&aacute;lisis y a diferentes concentraciones. Las muestras son estables al ser mantenidas en refrigeraci&oacute;n a 4&deg;C.</font></p>  	    <p align="justify"><font face="verdana" size="2">El m&eacute;todo desarrollado es adecuado para su uso en el laboratorio de control de calidad para el an&aacute;lisis de rutina de Indometacina Crema, considerando que es una formulaci&oacute;n nanoparticulada.</font></p>  	    <p>&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Referencias</b></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">1. Vadem Intl. UBM Medica Espa&ntilde;a. Edici&oacute;n 2010.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903005&pid=S1870-0195201100010000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <p align="justify"><font face="verdana" size="2">2. Eur Pharm Sixth edition 2007 Convention on the Elaboration of a European Pharmacopoeia (European treaty series No. 50). Published: Directorate for the Quality of Medicines &amp; Health Care of the Council of Europe.</font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">3. Adegoke O.A.,Idowu O.S., Olaniyi A.A. 2006. Novel colorimetric assay of indomethacin using 4&#45;carboxyl&#45;2,6&#45;dinitrobenzene diazonium ion. <i>Acta Pharm,</i> 56(2):189&#45;202.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903008&pid=S1870-0195201100010000600002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">4. Nagaraja P., Vasantha R.A., Yathirajan H.S.2003. Sensitive spectrophotometric method for the determination of indomethacin in capsules. <i>J Pharm Biomed Anal,</i> 31(3):563&#45;569.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903010&pid=S1870-0195201100010000600003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">5. Aman T.,Naureen F., Kazi A.A., Khan I.U., Kashmiri M. A. 2002. Ammonium molybdate as a spectrophotometric reagent for the determination of indomethacin in pure and pharmaceutical preparations. <i>Anal Let,</i> 35(6):1007&#45;1020.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903012&pid=S1870-0195201100010000600004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">6. Pinto P., Saraiva M.L., Santos J., Lima J. 2005. A pulsed sequential injection analysis flow system for the flourimetric determination of indomethacin in pharmaceutical preparations. <i>Anal Chim Acta,</i> 539:173&#45;179.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903014&pid=S1870-0195201100010000600005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">7. Makino K., Yano T., Maiguma T., Teshima D., Sendo T., Itoh Y., Oishi R. 2003. A rapid and simultaneous determination of several analgesic antiinflammatory agents by capillary zone electrophoresis. <i>Ther Drug Monit,</i> 25(5): 574&#45;580.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903016&pid=S1870-0195201100010000600006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">8. Krzek J.,Starek M. 2001. Simultaneous densitometric determination of indomethacin and its degradation products, 4&#45;chlorobenzoic acid and 5&#45;methoxy&#45;2&#45;methyl&#45;3&#45;indoleacetic acid, in pharmaceutical preparations. <i>J AOAC Int,</i> 84(6):1703&#45;1707.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903018&pid=S1870-0195201100010000600007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">9. Abdel&#45;Hamid M.E., Novotny L., Hamza H. 2001. Determination of diclofenac sodium, flufenamic acid, indomethacin and ketoprofen by LC&#45;APCI&#45;MS. <i>J Pharm Biomed Anal,</i> 24:587&#45;594.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903020&pid=S1870-0195201100010000600008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">10. Nov&aacute;kov&aacute; L., Matysov&aacute; L., Havl&iacute;kov&aacute; L., Solich P. 2005.Development and validation of HPLC method for determination of indomethacin and its two degradation products in topical gel. <i>J Pharm Biomed Anal,</i> 37:899&#45;903.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903022&pid=S1870-0195201100010000600009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">11. Khuhawar M.Y., Rind F.M.A., Rajper A.D. 2005. High&#45;Performance liquid chromatographic determination of isoniazid, pyrazinamide, and indomethacin en pharmaceutical preparations. <i>Acta Chromatogr,</i> 15:269&#45;275.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903024&pid=S1870-0195201100010000600010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">12. Mart&iacute;nez&#45;Algaba C., Escuder&#45;Gilabert L., Sagrado S., Villanueva&#45;Cama&ntilde;as R.M., Medina&#45;Hern&aacute;ndez J.M. 2004. Comparison between sodium dodecylsulphate and cetyltrimethylammnoium bromide as mobile phases in the micellar liquid chromatography determination of non&#45;steroidal anti&#45;inflammatory drugs in pharmaceuticals. <i>J Pharm Biomed Anal,</i> 36(2):393&#45;399.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903026&pid=S1870-0195201100010000600011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">13. Xueqi L., Ling L., Lianqiu L. 2007. Determination the Content of Indometacin Enteric&#45;Coated Tablets by HPLC. <i>Chin Pharm,</i> 3:27.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903028&pid=S1870-0195201100010000600012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">14. Zhang Y., Zhang Z., Qi G., Sun Y., Wei Y., Ma H. 2007. Detection of indomethacin by high&#45;performance liquid chromatography with in situ electrogenerated Mn (III) chemiluminescence detection. <i>Anal Chim Acta,</i> 582(2):229&#45;234.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903030&pid=S1870-0195201100010000600013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">15. Al Za'abi M.A., Dehghanzadeh G.H., Norris R.L., Charles B.G. 2006. A rapid and sensitive microscale HPLC method for the determination of indomethacin in plasma of premature neonates with patente ductus arteriousus. <i>J Chromatogr B&#45;anal Tech Biomed Sci,</i> 830(2):364&#45;367.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903032&pid=S1870-0195201100010000600014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">16. Boon V., Glass B., Nimmo A. 2006. High&#45;Performance Liquid Chromatographic Assay of Indomethacin in Porcine Plasma with Applicability to Human Levels. <i>J Chromatogr Sci,</i> 44(1):41&#45;44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903034&pid=S1870-0195201100010000600015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">17. Johnson AG., Ray J.E. 1992. Improved high&#45;performance liquid chromatographic method for the determination of indomethacin in plasma. <i>Ther Drug Monit,</i> 14(1):61&#45;65.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903036&pid=S1870-0195201100010000600016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">18. Sato J., Amisuka T., Umetsu M., Ito K. 1997. Simple, rapid and sensitive method for the determination of indomethacin in plasma by high&#45;performance liquid chromatography with ultraviolet detection. <i>J Chromatogr B. Biomed Sci App,</i> 692(1):241&#45;244.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903038&pid=S1870-0195201100010000600017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">19. FEUM. 2008. 9<sup>a</sup>. Edici&oacute;n. Secretar&iacute;a de Salud y Comisi&oacute;n Permanente de la Farmacopea de los Estados Unidos Mexicanos.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903040&pid=S1870-0195201100010000600018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">20. USP&#45;NF2009 (USP 32 NF 27). United States Pharmacopeial Convention, Inc., meeting at Washington, D.C. Prepared by the Committee of Revision and published by the Board Trustees.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903042&pid=S1870-0195201100010000600019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">21. M&uuml;ller RH., M&aacute;der K., Gohla S., 2000: Solid lipid nanoparticles (SLN) for controlled drug delivery &#45; a review of the state of the art. <i>Eur J Pharm Biophar,</i> 50, 161&#45;177.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903044&pid=S1870-0195201100010000600020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">22. Carlucci AM., Bregni C., 2009. Productos nanotecnol&oacute;gicos de aplicaci&oacute;n en farmacoterapia. <i>Lat Am J Pharm,</i> 28(3), 470&#45;477.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903046&pid=S1870-0195201100010000600021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">23. Wechsler J.2006.: Los nanomateriales plantean nuevos desaf&iacute;os. <i>Pharm Technol (en Espa&ntilde;ol),</i> Sep/Oct 2006, 62&#45;66.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=7903048&pid=S1870-0195201100010000600022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<collab>Vadem Intl</collab>
<source><![CDATA[UBM Medica España]]></source>
<year>2010</year>
</nlm-citation>
</ref>
<ref id="B2">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Adegoke]]></surname>
<given-names><![CDATA[O.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Idowu]]></surname>
<given-names><![CDATA[O.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Olaniyi]]></surname>
<given-names><![CDATA[A.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Novel colorimetric assay of indomethacin using 4-carboxyl-2,6-dinitrobenzene diazonium ion]]></article-title>
<source><![CDATA[Acta Pharm]]></source>
<year></year>
<volume>56</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>189-202</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nagaraja]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Vasantha]]></surname>
<given-names><![CDATA[R.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Yathirajan]]></surname>
<given-names><![CDATA[H.S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sensitive spectrophotometric method for the determination of indomethacin in capsules]]></article-title>
<source><![CDATA[J Pharm Biomed Anal]]></source>
<year></year>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>563-569</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aman]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Naureen]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Kazi]]></surname>
<given-names><![CDATA[A.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[I.U.]]></given-names>
</name>
<name>
<surname><![CDATA[Kashmiri]]></surname>
<given-names><![CDATA[M. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ammonium molybdate as a spectrophotometric reagent for the determination of indomethacin in pure and pharmaceutical preparations]]></article-title>
<source><![CDATA[Anal Let]]></source>
<year></year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1007-1020</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pinto]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Saraiva]]></surname>
<given-names><![CDATA[M.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A pulsed sequential injection analysis flow system for the flourimetric determination of indomethacin in pharmaceutical preparations]]></article-title>
<source><![CDATA[Anal Chim Acta]]></source>
<year></year>
<volume>539</volume>
<page-range>173-179</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Makino]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Yano]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Maiguma]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Teshima]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Sendo]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Itoh]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Oishi]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A rapid and simultaneous determination of several analgesic antiinflammatory agents by capillary zone electrophoresis]]></article-title>
<source><![CDATA[Ther Drug Monit]]></source>
<year></year>
<volume>25</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>574-580</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Krzek]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Starek]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simultaneous densitometric determination of indomethacin and its degradation products, 4-chlorobenzoic acid and 5-methoxy-2-methyl-3-indoleacetic acid, in pharmaceutical preparations]]></article-title>
<source><![CDATA[J AOAC Int]]></source>
<year></year>
<volume>84</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1703-1707</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abdel-Hamid]]></surname>
<given-names><![CDATA[M.E.]]></given-names>
</name>
<name>
<surname><![CDATA[Novotny]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Hamza]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of diclofenac sodium, flufenamic acid, indomethacin and ketoprofen by LC-APCI-MS]]></article-title>
<source><![CDATA[J Pharm Biomed Anal]]></source>
<year></year>
<volume>24</volume>
<page-range>587-594</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nováková]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Matysová]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Havlíková]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Solich]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development and validation of HPLC method for determination of indomethacin and its two degradation products in topical gel]]></article-title>
<source><![CDATA[J Pharm Biomed Anal]]></source>
<year></year>
<volume>37</volume>
<page-range>899-903</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khuhawar]]></surname>
</name>
<name>
<surname><![CDATA[Rind]]></surname>
<given-names><![CDATA[F.M.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rajper]]></surname>
<given-names><![CDATA[A.D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-Performance liquid chromatographic determination of isoniazid, pyrazinamide, and indomethacin en pharmaceutical preparations]]></article-title>
<source><![CDATA[Acta Chromatogr]]></source>
<year></year>
<volume>15</volume>
<page-range>269-275</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez-Algaba]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Escuder-Gilabert]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Sagrado]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Villanueva-Camañas]]></surname>
<given-names><![CDATA[R.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Medina-Hernández]]></surname>
<given-names><![CDATA[J.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison between sodium dodecylsulphate and cetyltrimethylammnoium bromide as mobile phases in the micellar liquid chromatography determination of non-steroidal anti-inflammatory drugs in pharmaceuticals]]></article-title>
<source><![CDATA[J Pharm Biomed Anal]]></source>
<year></year>
<volume>36</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>393-399</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xueqi]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Ling]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Lianqiu]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination the Content of Indometacin Enteric-Coated Tablets by HPLC]]></article-title>
<source><![CDATA[Chin Pharm]]></source>
<year></year>
<volume>3</volume>
<page-range>27</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Qi]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Sun]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Wei]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Detection of indomethacin by high-performance liquid chromatography with in situ electrogenerated Mn (III) chemiluminescence detection]]></article-title>
<source><![CDATA[Anal Chim Acta]]></source>
<year></year>
<volume>582</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>229-234</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Al Za'abi]]></surname>
<given-names><![CDATA[M.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Dehghanzadeh]]></surname>
<given-names><![CDATA[G.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Norris]]></surname>
<given-names><![CDATA[R.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Charles]]></surname>
<given-names><![CDATA[B.G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A rapid and sensitive microscale HPLC method for the determination of indomethacin in plasma of premature neonates with patente ductus arteriousus]]></article-title>
<source><![CDATA[J Chromatogr B-anal Tech Biomed Sci]]></source>
<year></year>
<volume>830</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>364-367</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boon]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Glass]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Nimmo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-Performance Liquid Chromatographic Assay of Indomethacin in Porcine Plasma with Applicability to Human Levels]]></article-title>
<source><![CDATA[J Chromatogr Sci]]></source>
<year></year>
<volume>44</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>41-44</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[AG.]]></given-names>
</name>
<name>
<surname><![CDATA[Ray]]></surname>
<given-names><![CDATA[J.E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improved high-performance liquid chromatographic method for the determination of indomethacin in plasma]]></article-title>
<source><![CDATA[Ther Drug Monit]]></source>
<year></year>
<volume>14</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>61-65</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sato]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Amisuka]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Umetsu]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Ito]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simple, rapid and sensitive method for the determination of indomethacin in plasma by high-performance liquid chromatography with ultraviolet detection]]></article-title>
<source><![CDATA[J Chromatogr B. Biomed Sci App]]></source>
<year></year>
<volume>692</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>241-244</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>19</label><nlm-citation citation-type="book">
<collab>FEUM</collab>
<source><![CDATA[]]></source>
<year>2008</year>
<edition>9</edition>
<publisher-name><![CDATA[Secretaría de Salud y Comisión Permanente de la Farmacopea de los Estados Unidos Mexicanos]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<label>20</label><nlm-citation citation-type="book">
<collab>USP-NF2009</collab>
<source><![CDATA[]]></source>
<year></year>
<publisher-loc><![CDATA[Washington^eD.C. D.C.]]></publisher-loc>
<publisher-name><![CDATA[United States Pharmacopeial Convention, Inc.Committee of Revision and published by the Board Trustees]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Müller]]></surname>
<given-names><![CDATA[RH.]]></given-names>
</name>
<name>
<surname><![CDATA[Máder]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Gohla]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solid lipid nanoparticles (SLN) for controlled drug delivery - a review of the state of the art]]></article-title>
<source><![CDATA[Eur J Pharm Biophar]]></source>
<year></year>
<volume>50</volume>
<page-range>161-177</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carlucci]]></surname>
<given-names><![CDATA[AM.]]></given-names>
</name>
<name>
<surname><![CDATA[Bregni]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Productos nanotecnológicos de aplicación en farmacoterapia]]></article-title>
<source><![CDATA[Lat Am J Pharm]]></source>
<year></year>
<volume>28</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>470-477</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wechsler]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Los nanomateriales plantean nuevos desafíos]]></article-title>
<source><![CDATA[Pharm Technol]]></source>
<year>Sep/</year>
<month>Oc</month>
<day>t </day>
<page-range>62-66</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
