<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1665-6423</journal-id>
<journal-title><![CDATA[Journal of applied research and technology]]></journal-title>
<abbrev-journal-title><![CDATA[J. appl. res. technol]]></abbrev-journal-title>
<issn>1665-6423</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Instituto de Ciencias Aplicadas y Tecnología]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1665-64232004000300005</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Digital blood pressure monitor]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fuentes]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bañuelos]]></surname>
<given-names><![CDATA[M. A.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Nacional Autónoma de México Centro de Ciencias Aplicadas y Desarrollo Tecnológico Laboratorio de Electrónica]]></institution>
<addr-line><![CDATA[México Distrito Federal]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2004</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2004</year>
</pub-date>
<volume>2</volume>
<numero>3</numero>
<fpage>224</fpage>
<lpage>229</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1665-64232004000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1665-64232004000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1665-64232004000300005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[In this work we present a blood pressure monitor which measures both the high blood pressure (systolic pressure), and the low blood pressure (diastolic pressure). It is a semiautomatic meter because the inflation of the occlusive cuff is carried out in a manual way. The transducer used is a piezoresistive silicon pressure sensor integrated on chip which provides a proportional voltage to the input pressure, with a measurement range from 0 to 50 kPa (07.3 PSI). The oscillometric method is employed, which consists on detecting the oscillometric signal on brachial artery, being processed at each pressure step, when the cuff is gradually deflated. Signal sampling is carried out at a rate determined by the heart rate. In order to program the digital electronics of the circuit we used Altera tools, with the compiler MAX-PLUS II, and the device selected to implement the design was an EPM7128SLC84-15 CPLD (Complex Programmable Logic Device).]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[El monitor digital de presión sanguínea disefado, que se presenta en este trabajo, mide tanto la presión sanguínea alta (presión sistólica), como la presión sanguínea baja (presión diastólica). Es un medidor semiautomático, es decir, el inflado de la faja de presión para el brazo se hace en forma manual. El transductor utilizado es un sensor de presión piezoresistivo integrado en forma de chip, cuya salida es un voltaje proporcional a la presión de entrada, con un intervalo de medición entre cero y 50 kPa (0-7.3 PSI). Para realizar la medición se utiliza el principio oscilométrico, que consiste en detectar la sefal oscilométrica sobre la arteria branquial, la cual es procesada para cada paso de presión, al tiempo que la faja de presión es desinflada en forma gradual. El muestreo de sefal se efectúa a un valor determinado por el valor del pulso cardiaco. Para programar la electrónica digital del circuito se usó la plataforma Altera, con el compilador MAX-PLUS II, y el dispositivo que se utilizó para implantar el diseño fue un CPLD, EPM7128SLC84-15.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Blood pressure monitor]]></kwd>
<kwd lng="en"><![CDATA[Altera applications]]></kwd>
<kwd lng="en"><![CDATA[Biomedical instrumentation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="center"><font face="verdana" size="4"><b>Digital blood pressure monitor</b></font></p>     <p align="center">&nbsp;</p>  	    <p align="center"><b><font face="verdana" size="2">R. Fuentes &amp; M. A. Ba&ntilde;uelos</font></b><font face="verdana" size="2"></font></p>     <p align="center">&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><i>Laboratorio de Electr&oacute;nica, Centro de Ciencias Aplicadas y Desarrollo Tecnol&oacute;gico UNAM, Apdo. Postal 70 &#45; 186, Coyoac&aacute;n 04510, M&eacute;xico, D. F.</i> Email: <a href="mailto:fuentesr@aleph.cinstrum.unam.mx">fuentesr@aleph.cinstrum.unam.mx</a></font></p>     <p align="justify">&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2">Received: January 15<sup>th</sup>, 2003.     <br>     Accepted: May 5<sup>th</sup>, 2003.</font></p> 	    <p align="justify">&nbsp;</p> 	    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"> <b>Abstract</b></font></p>  	    <p align="justify"><font face="verdana" size="2">In this work we present a blood pressure monitor which measures both the high blood pressure (systolic pressure), and the low blood pressure (diastolic pressure). It is a semiautomatic meter because the inflation of the occlusive cuff is carried out in a manual way. The transducer used is a piezoresistive silicon pressure sensor integrated on chip which provides a proportional voltage to the input pressure, with a measurement range from 0 to 50 kPa (07.3 PSI). The oscillometric method is employed, which consists on detecting the oscillometric signal on brachial artery, being processed at each pressure step, when the cuff is gradually deflated. Signal sampling is carried out at a rate determined by the heart rate.</font></p>  	    <p align="justify"><font face="verdana" size="2">In order to program the digital electronics of the circuit we used Altera tools, with the compiler MAX&#45;PLUS II, and the device selected to implement the design was an EPM7128SLC84&#45;15 CPLD (Complex Programmable Logic Device).</font></p> 	    <p align="justify"><font face="verdana" size="2"><b>Keywords:</b> Blood pressure monitor, Altera applications, Biomedical instrumentation.</font></p>     <p align="justify">&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>  	    <p align="justify"><font face="verdana" size="2">El monitor digital de presi&oacute;n sangu&iacute;nea disefado, que se presenta en este trabajo, mide tanto la presi&oacute;n sangu&iacute;nea alta (presi&oacute;n sist&oacute;lica), como la presi&oacute;n sangu&iacute;nea baja (presi&oacute;n diast&oacute;lica). Es un medidor semiautom&aacute;tico, es decir, el inflado de la faja de presi&oacute;n para el brazo se hace en forma manual. El transductor utilizado es un sensor de presi&oacute;n piezoresistivo integrado en forma de chip, cuya salida es un voltaje proporcional a la presi&oacute;n de entrada, con un intervalo de medici&oacute;n entre cero y 50 kPa (0&#45;7.3 PSI). Para realizar la medici&oacute;n se utiliza el principio oscilom&eacute;trico, que consiste en detectar la sefal oscilom&eacute;trica sobre la arteria branquial, la cual es procesada para cada paso de presi&oacute;n, al tiempo que la faja de presi&oacute;n es desinflada en forma gradual. El muestreo de sefal se efect&uacute;a a un valor determinado por el valor del pulso cardiaco.</font></p>  	    <p align="justify"><font face="verdana" size="2">Para programar la electr&oacute;nica digital del circuito se us&oacute; la plataforma Altera, con el compilador MAX&#45;PLUS II, y el dispositivo que se utiliz&oacute; para implantar el dise&ntilde;o fue un CPLD, EPM7128SLC84&#45;15.</font></p>     <p align="justify">&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><a href="/pdf/jart/v2n3/v2n3a5.pdf" target="_blank">DESCARGAR ART&Iacute;CULO EN FORMATO PDF</a></font></p> 	    ]]></body>
<body><![CDATA[<p align="justify">&nbsp;</p>  	    <p align="justify"><font face="verdana" size="2"><b>Reference</b></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;1&#93;&nbsp;Cromwell L. and Weibell F. J. Biomedical instrumentation and measurements, Prentice&#45;Hall, Inc, 1980.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816049&pid=S1665-6423200400030000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;2&#93;&nbsp;Aston R. Principles of Biomedical Instrumentation and Measurement, Merrill Publishing Company, 1990.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816051&pid=S1665-6423200400030000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;3&#93;&nbsp;Motorola Inc. Pressure Sensor Device Data, 1993.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816053&pid=S1665-6423200400030000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;4&#93;&nbsp;Franco S. Design with operational amplifiers and analog integrated circuits, Mc Graw&#45;Hill, 1988.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816055&pid=S1665-6423200400030000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">&#91;5&#93;&nbsp;Fabricius E. Modern digital design switching theory, CRC Press, Inc. U.S.A., 1992.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816057&pid=S1665-6423200400030000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;6&#93;&nbsp;Mano M. Digital Logic and computer Design, Prentice Hall, Inc. Mexico, 1987.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816059&pid=S1665-6423200400030000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;7&#93;&nbsp;Altera Corporation. MAX+PLUS II Graphic &amp; Symbol Editors. San Jose, California,1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816061&pid=S1665-6423200400030000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;8&#93;&nbsp;Altera Corporation. MAX+PLUS II Compiler. San Jose, California,1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816063&pid=S1665-6423200400030000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;9&#93;&nbsp;Altera Corporation. MAX+PLUS II Simulator, Timing Analizer &amp; Waveform Editor, 1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816065&pid=S1665-6423200400030000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>  	    ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">&#91;10&#93;&nbsp;Altera Corporation. MAX+PLUS II Text Editor &amp; AHDL. San Jose, California,1997.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=4816067&pid=S1665-6423200400030000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cromwell]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Weibell]]></surname>
<given-names><![CDATA[F. J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Biomedical instrumentation and measurements]]></source>
<year>1980</year>
<publisher-name><![CDATA[Prentice-Hall, Inc]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aston]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Principles of Biomedical Instrumentation and Measurement]]></source>
<year>1990</year>
<publisher-name><![CDATA[Merrill Publishing Company]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="">
<collab>Motorola Inc.</collab>
<source><![CDATA[Pressure Sensor Device Data]]></source>
<year>1993</year>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franco]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Design with operational amplifiers and analog integrated circuits]]></source>
<year>1988</year>
<publisher-name><![CDATA[Mc Graw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fabricius]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Modern digital design switching theory]]></source>
<year>1992</year>
<publisher-name><![CDATA[CRC Press, Inc.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mano]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Digital Logic and computer Design]]></source>
<year>1987</year>
<publisher-name><![CDATA[Prentice Hall, Inc.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="">
<collab>Altera Corporation</collab>
<source><![CDATA[MAX+PLUS II Graphic & Symbol Editors]]></source>
<year>1997</year>
<publisher-loc><![CDATA[^eCalifornia California]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<collab>Altera Corporation</collab>
<source><![CDATA[MAX+PLUS II Compiler]]></source>
<year>1997</year>
<publisher-loc><![CDATA[^eCalifornia California]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<collab>Altera Corporation</collab>
<source><![CDATA[MAX+PLUS II Simulator]]></source>
<year>1997</year>
<publisher-name><![CDATA[Timing Analizer & Waveform Editor]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<collab>Altera Corporation</collab>
<source><![CDATA[MAX+PLUS II Text Editor & AHDL]]></source>
<year>1997</year>
<publisher-loc><![CDATA[San Jose^eCalifornia California]]></publisher-loc>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>