<article-meta>
<article-id>S1405-99402002000300005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Seguimiento de un grupo de pacientes con desfibrilador automático implantable]]></article-title>
<article-title xml:lang="en"><![CDATA[Follow-up of a group of patients with automatic implantable defibrillator]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mendoza González]]></surname>
<given-names><![CDATA[Celso]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Iturralde Torres]]></surname>
<given-names><![CDATA[Pedro]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guevara Valdivia]]></surname>
<given-names><![CDATA[Milton E]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Medeiros Domingo]]></surname>
<given-names><![CDATA[Argelia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Chávez]]></surname>
<given-names><![CDATA[Laura]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Briones]]></surname>
<given-names><![CDATA[Ignacio]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Colin Lizalde]]></surname>
<given-names><![CDATA[Luis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Nacional de Cardiología Ignacio Chávez Departamento de Arritmias ]]></institution>
<addr-line><![CDATA[México Distrito Federal]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2002</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2002</year>
</pub-date>
<volume>72</volume>
<numero>3</numero>
<fpage>220</fpage>
<lpage>226</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402002000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402002000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402002000300005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El desfibrilador automático implantable (DAI) es el tratamiento de elección para la prevención primaria y secundaria de la muerte súbita (MS). En el Instituto Nacional de Cardiología, se han colocado 26 DAI en 25 pacientes de octubre de 1996 a enero del 2002. Hubo 23 hombres (92%) y la edad media del grupo fue de 51.4 años; 23 pacientes (92%) tuvieron cardiopatía estructural, la más frecuente fue la cardiopatía isquémica en 13 pacientes (52%) con un valor medio de la fracción de expulsión (FE) de 37.8%. Un paciente sin cardiopatía estructural tenía síndrome de Brugada. La arritmia clínica más frecuente fue taquicardia ventricular monomórfica sostenida (TVMS) en 14 pacientes (56%). El seguimiento de estos pacientes tuvo un valor medio de 29.3 meses; durante este período se registraron 30 terapias aplicadas por el DAI, 6 de ellas fueron inapropiadas por fibrilación atrial paroxística (FAP). En 10 DAI (34%) no se ha aplicado ninguna terapia. Ha habido tres muertes (12%) por insuficiencia cardíaca refractaria a tratamiento farmacológico. Conclusiones: La implantación del DAI es una medida segura y efectiva para la prevención primaria y secundaria de la MS. En la experiencia mundial, este dispositivo no ha modificado la mortalidad por insuficiencia cardíaca de estos enfermos, pero si la MS arrítmica.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The automatic implantable defibrillator (AID) is the treatment of choice for primary and secondary prevention of sudden death. At the Instituto Nacional de Cardiología, since October 1996 until January 2002, 25 patients were implanted with 26 AID. There were 23 men (92%) and the mean age of the whole group, was 51.4 years. Twenty-three patients (92%) presented structural heart disease, the most common was ischemic heart disease in 13 patients (52%), with a mean ejection fraction of 37.8%. One patient without structural heart disease had Brugada Syndrome. The most frequent clinical arrhythmia was ventricular tachycardia in 14 patients (56%). The mean follow-up was of 29.3 months during which a total of 30 events of ventricular arrhythmia were treated through AID; six of them were inappropriate due to paroxismal atrial fibrillation; 10 AID patients (34%) have not applied for therapy. Three patients (12%) of the group died due to congestive heart failure refractory to pharmacologic treatment. Conclusion: The implant of the AID is a safe and effective measure for primary and secondary prevention of sudden death. World-wide experience evidences, that this kind of device has not modified the mortality rate due to heart failure in these patients, but it has diminished sudden arrhythmic death.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Desfibrilador automático implantable]]></kwd>
<kwd lng="es"><![CDATA[Arritmia cardíaca]]></kwd>
<kwd lng="es"><![CDATA[Muerte súbita]]></kwd>
<kwd lng="en"><![CDATA[Automatic implantable defibrillator]]></kwd>
<kwd lng="en"><![CDATA[Cardiac arrhythmia]]></kwd>
<kwd lng="en"><![CDATA[Sudden death]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="Verdana" size="4">Investigaci&oacute;n cl&iacute;nica</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Seguimiento de un grupo de pacientes con desfibrilador autom&aacute;tico implantable</b></font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="3"><b>Follow&#45;up of a group of patients with automatic implantable defibrillator</b></font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>Celso Mendoza Gonz&aacute;lez,* Pedro Iturralde Torres,* Milton E Guevara Valdivia,* Argelia Medeiros Domingo,* Laura Rodr&iacute;guez Ch&aacute;vez,* Ignacio Rodr&iacute;guez Briones,* Luis Colin Lizalde*</b></font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i>* Departamento de Arritmias, Instituto Nacional de Cardiolog&iacute;a "Ignacio Ch&aacute;vez".</i></font></p>     <p align="justify"><font face="verdana" size="2"><b>Correspondencia: </b><i>    ]]></body>
<body><![CDATA[<br> Dr. Pedro Iturralde Torres.     <br> Departamento de Arritmias del     <br> Instituto Nacional de Cardiolog&iacute;a "Ignacio Ch&aacute;vez"     <br> (INCICH, Juan Badiano No. 1, Col. Secci&oacute;n XVI,     <br> Tlalpan, 14080 M&eacute;xico, D. F.).     <br> Tel: 5513 3740, Fax: 55730994.</i></font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">Recibido: 27 de febrero de 2002     <br> Aceptado: 10 de junio de 2002</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     <p align="justify"><font face="verdana" size="2">El desfibrilador autom&aacute;tico implantable (DAI) es el tratamiento de elecci&oacute;n para la prevenci&oacute;n primaria y secundaria de la muerte s&uacute;bita (MS). En el Instituto Nacional de Cardiolog&iacute;a, se han colocado 26 DAI en 25 pacientes de octubre de 1996 a enero del 2002. Hubo 23 hombres (92%) y la edad media del grupo fue de 51.4 a&ntilde;os; 23 pacientes (92%) tuvieron cardiopat&iacute;a estructural, la m&aacute;s frecuente fue la cardiopat&iacute;a isqu&eacute;mica en 13 pacientes (52%) con un valor medio de la fracci&oacute;n de expulsi&oacute;n (FE) de 37.8%. Un paciente sin cardiopat&iacute;a estructural ten&iacute;a s&iacute;ndrome de Brugada. La arritmia cl&iacute;nica m&aacute;s frecuente fue taquicardia ventricular monom&oacute;rfica sostenida (TVMS) en 14 pacientes (56%). El seguimiento de estos pacientes tuvo un valor medio de 29.3 meses; durante este per&iacute;odo se registraron 30 terapias aplicadas por el DAI, 6 de ellas fueron inapropiadas por fibrilaci&oacute;n atrial parox&iacute;stica (FAP). En 10 DAI (34%) no se ha aplicado ninguna terapia. Ha habido tres muertes (12%) por insuficiencia card&iacute;aca refractaria a tratamiento farmacol&oacute;gico. </font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusiones:</b> La implantaci&oacute;n del DAI es una medida segura y efectiva para la prevenci&oacute;n primaria y secundaria de la MS. En la experiencia mundial, este dispositivo no ha modificado la mortalidad por insuficiencia card&iacute;aca de estos enfermos, pero si la MS arr&iacute;tmica.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave:</b> Desfibrilador autom&aacute;tico implantable. Arritmia card&iacute;aca. Muerte s&uacute;bita.</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Summary</b></font></p>     <p align="justify"><font face="verdana" size="2">The automatic implantable defibrillator (AID) is the treatment of choice for primary and secondary prevention of sudden death. At the Instituto Nacional de Cardiolog&iacute;a, since October 1996 until January 2002, 25 patients were implanted with 26 AID. There were 23 men (92%) and the mean age of the whole group, was 51.4 years. Twenty&#45;three patients (92%) presented structural heart disease, the most common was ischemic heart disease in 13 patients (52%), with a mean ejection fraction of 37.8%. One patient without structural heart disease had Brugada Syndrome. The most frequent clinical arrhythmia was ventricular tachycardia in 14 patients (56%). The mean follow&#45;up was of 29.3 months during which a total of 30 events of ventricular arrhythmia were treated through AID; six of them were inappropriate due to paroxismal atrial fibrillation; 10 AID patients (34%) have not applied for therapy. Three patients (12%) of the group died due to congestive heart failure refractory to pharmacologic treatment. </font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusion:</b> The implant of the AID is a safe and effective measure for primary and secondary prevention of sudden death. World&#45;wide experience evidences, that this kind of device has not modified the mortality rate due to heart failure in these patients, but it has diminished sudden arrhythmic death. </font></p>     <p align="justify"><font face="verdana" size="2"><b>Key words:</b> Automatic implantable defibrillator. Cardiac arrhythmia. Sudden death.</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Introducci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">El desfibrilador autom&aacute;tico implantable (DAI) se ha convertido en el m&eacute;todo de elecci&oacute;n para la prevenci&oacute;n primaria y secundaria de la muerte s&uacute;bita (MS). Los adelantos tecnol&oacute;gicos han mejorado la efectividad de estos dispositivos pero su costo elevado implica un uso limitado. La alta incidencia de la MS ha motivado el estudio de nuevas estrategias de prevenci&oacute;n y de este modo, en los 20 a&ntilde;os de evoluci&oacute;n de estos dispositivos, se ha logrado mejorar su efectividad quedando demostrada la superioridad que tienen en relaci&oacute;n con los f&aacute;rmacos antiarr&iacute;tmicos en pacientes de alto riesgo para MS.<sup>1&#45;3</sup></font></p>     <p align="justify"><font face="verdana" size="2">En este estudio se definen las caracter&iacute;sticas cl&iacute;nicas, evoluci&oacute;n y seguimiento de los pacientes a quienes se les ha implantado un DAI en el Instituto Nacional de Cardiolog&iacute;a.</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Material y m&eacute;todos</b></font></p>     <p align="justify"><font face="verdana" size="2">Se revisaron los expedientes cl&iacute;nicos de 25 pacientes a quienes se les ha implantado un DAI a partir del mes de octubre de 1996 hasta el mes de enero del 2002. Se recab&oacute; la informaci&oacute;n relacionada al perfil cl&iacute;nico, laboratorio y gabinete de estos enfermos, la arritmia cl&iacute;nica documentada, los datos del electrocardiograma, ecocardiograf&iacute;a, perfusi&oacute;n mioc&aacute;rdica, coronariograf&iacute;a y estudio electrofisiol&oacute;gico. El seguimiento se realiz&oacute; a trav&eacute;s de interrogatorio del dispositivo mediante telemetr&iacute;a.</font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resultados</b></font></p>     <p align="justify"><font face="verdana" size="2">Durante el per&iacute;odo comprendido de octubre de 1996 a enero del 2002 se han colocado 26 desfibriladores en 25 pacientes con un seguimiento de uno a 63 meses (media de 29.3 meses). Las caracter&iacute;sticas generales de los pacientes se muestran en la <i><a href="#c1">Tabla I</a></i>. En el grupo hubo 23 hombres (92%) y el rango de edad se encontr&oacute; de los 30 a los 78 a&ntilde;os con una media de 51.43. Al momento de implantar el DAI 14 pacientes (56%) se encontraron en clase funcional I de la New York Heart Association, 7 pacientes (28%) estaban en clase funcional II y 4 pacientes (16%) en clase funcional III. La cardiopat&iacute;a isqu&eacute;mica se encontr&oacute; en 13 pacientes (52%), ninguno de ellos con isquemia residual, mientras que 7 pacientes (28%) tuvieron miocardiopat&iacute;a dilatada y 3 pacientes (12%) tuvieron cardiopat&iacute;a valvular. No se document&oacute; cardiopat&iacute;a estructural en 2 pacientes (8%); a uno de ellos se le diagnostic&oacute; s&iacute;ndrome de Brugada y al otro taquicardia ventricular idiop&aacute;tica. A un paciente con cardiomiopat&iacute;a dilatada idiop&aacute;tica se le coloc&oacute; el DAI en espera de un trasplante de coraz&oacute;n; durante el tiempo que tuvo este dispositivo se registr&oacute; un evento de TVMS que fue interrumpido por el DAI. A otro paciente se le realiz&oacute; cambio del generador por agotamiento de la fuente. Se encontr&oacute; dilataci&oacute;n del ventr&iacute;culo izquierdo en 12 pacientes (48%), con una media del di&aacute;metro diast&oacute;lico del ventr&iacute;culo izquierdo de 61 mm y media del di&aacute;metro sist&oacute;lico del ventr&iacute;culo izquierdo de 48 mm. La media de la presi&oacute;n telediast&oacute;lica del ventr&iacute;culo izquierdo fue de 18 mmHg. La fracci&oacute;n de expulsi&oacute;n (FE) media fue de 37.8%. La arritmia cl&iacute;nica m&aacute;s com&uacute;n fue TVMS en 14 pacientes (56%) mientras que 5 pacientes (20%) tuvieron fibrilaci&oacute;n ventricular (FV) y este mismo n&uacute;mero present&oacute; ambas. Durante el estudio electrofisiol&oacute;gico se desencaden&oacute; TVMS en 16 pacientes (64%) con una longitud de ciclo (LC) media de 347 mseg, 4 pacientes (16%) desarrollaron FV y 5 pacientes (20%) presentaron ambas durante la estimulaci&oacute;n el&eacute;ctrica. El paciente portador de s&iacute;ndrome de Brugada no tuvo arritmia cl&iacute;nica; la indicaci&oacute;n para implantar el DAI fue la inducci&oacute;n de FV en el estudio electrofisiol&oacute;gico y el antecedente de MS en un hermano joven. Al momento del implante del DAI, 23 pacientes (92%) recib&iacute;an tratamiento farmacol&oacute;gico por insuficiencia card&iacute;aca, 6 pacientes (24%) hab&iacute;an sido sometidos a revascularizaci&oacute;n coronaria, a 2 pacientes (8%) se les hab&iacute;a realizado cambio valvular mitral, y en 2 pacientes (8%) se hab&iacute;a realizado alg&uacute;n tipo de intervenci&oacute;n coronaria. Tuvieron tratamiento antiarr&iacute;tmico con amiodarona previo al estudio electrofisiol&oacute;gico 21 pacientes (84%) y 24 pacientes (96%) lo continuaron despu&eacute;s de implantado el DAI. A un paciente se le trat&oacute; con sotalol para el control de fibrilaci&oacute;n auricular parox&iacute;stica (FAP). En el seguimiento se han detectado un total de 60 eventos de taquicardia; de ellos, 30 episodios fueron no sostenidos y no recibieron ning&uacute;n tipo de terapia. De las terapias aplicadas, 6 fueron consideradas inapropiadas ocasionadas por FAP; de las restantes, 2 fueron por TVMS r&aacute;pida <i>(<a href="/img/revistas/acm/v72n3/a5f1.jpg" target="_blank">Fig. 1</a>)</i>, 10 por TVMS lenta y 12 fueron por FV <i>(<a href="/img/revistas/acm/v72n3/a5f2.jpg" target="_blank">Fig. 2</a>).</i> Se implementaron m&aacute;s criterios para el reconocimiento de la arritmia y se logr&oacute; reducir el n&uacute;mero de descargas inapropiadas. La relaci&oacute;n entre la cardiopat&iacute;a subyacente con las arritmias ventriculares y el seguimiento del DAI se se&ntilde;ala en la <i><a href="/img/revistas/acm/v72n3/a5c2.jpg" target="_blank">Tabla II</a>.</i> Hasta el momento, ha habido tres defunciones (12%) que se relacionaron a insuficiencia card&iacute;aca refractaria a tratamiento farmacol&oacute;gico. No se han encontrado muertes por eventos arr&iacute;tmicos ni se han presentado complicaciones relacionadas al implante del dispositivo.</font></p>     <p align="center"><font face="verdana" size="2"><a name="c1"></a></font></p>     ]]></body>
<body><![CDATA[<p align="center"><font face="verdana" size="2"><img src="/img/revistas/acm/v72n3/a5c1.jpg"></font></p>     <p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Discusi&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">Existe acuerdo general en que el DAI es el tratamiento de elecci&oacute;n para pacientes que han presentado, o que tienen alto riesgo de desarrollar, un evento de MS. La recurrencia de uno de estos eventos en pacientes a quienes se les ha implantado el DAI disminuye a menos de 1%.<sup>4,5</sup> A pesar de la incuestionable eficacia del DAI en la prevenci&oacute;n de la MS, la presencia de insuficiencia card&iacute;aca congestiva sigue limitando los beneficios en la sobrevida global de estos enfermos.<sup>6</sup></font></p>     <p align="justify"><font face="verdana" size="2">Las primeras comunicaciones sobre la utilidad de los DAI tuvieron siempre puntos controversiales, que despertaron la inquietud de realizar estudios controlados prospectivos bien dise&ntilde;ados para evaluar su impacto en la sobrevida de pacientes rescatados de un evento de MS y en portadores de TVS con deterioro hemodin&aacute;mico o bien en pacientes de alto riesgo para el desarrollo de alguno de estos eventos.</font></p>     <p align="justify"><font face="verdana" size="2">El DAI como m&eacute;todo de prevenci&oacute;n primaria, requiere de un adecuado proceso de identificaci&oacute;n de la poblaci&oacute;n con alto riesgo para MS, que incluya la evaluaci&oacute;n de la funci&oacute;n ventricular, de la existencia de insuficiencia card&iacute;aca, ectop&iacute;a ventricular, potenciales tard&iacute;os en el ECG de se&ntilde;al promediada, variabilidad de la frecuencia card&iacute;aca e inducibilidad de las arritmias en el laboratorio de electrofisiolog&iacute;a.<sup>7,8</sup> Los resultados de algunos de los estudios multic&eacute;ntricos,<sup>9&#45;13</sup> que han demostrado la mejor&iacute;a de la sobrevida y disminuci&oacute;n de la mortalidad con el DAI, se muestran en la <i><a href="/img/revistas/acm/v72n3/a5c3.jpg" target="_blank">Tabla III</a>;</i> estos estudios ponen de manifiesto la necesidad de seleccionar a las poblaciones con alto riesgo de MS.</font></p>     <p align="justify"><font face="verdana" size="2">Las indicaciones actuales para el implante de un DAI se han extendido a grupos de pacientes con otras caracter&iacute;sticas; los pacientes con s&iacute;ncope de origen indeterminado, a quienes se les induce TV en el laboratorio de electrofisiolog&iacute;a, han mostrado tener una incidencia alta de descargas adecuadas del DAI.<sup>14</sup></font></p>     <p align="justify"><font face="verdana" size="2">El papel del DAI en pacientes con cardiopat&iacute;a estructural y TV monom&oacute;rfica sostenida estable es menos claro y en ellos se buscan opciones de tratamiento diferentes como la ablaci&oacute;n con cat&eacute;ter.<sup>15</sup> Por otra parte, el DAI no tiene indicaci&oacute;n en aquellos pacientes que han sufrido arritmias ventriculares desencadenadas por infarto agudo del miocardio, alteraciones metab&oacute;licas corregibles o fibrilaci&oacute;n auricular r&aacute;pida que complica un s&iacute;ndrome de Wolff&#45;Parkinson&#45;White. Los pacientes con una expectativa de vida menor a un a&ntilde;o tampoco se consideran como candidatos para el implante de un desfibrilador. En los pacientes que se encuentran en lista de espera para trasplante card&iacute;aco, la colocaci&oacute;n de un DAI como puente hasta el momento del trasplante disminuye la incidencia de MS, sin embargo, no se modifica la evoluci&oacute;n natural de la falla card&iacute;aca.<sup>16,17</sup> Recientemente se ha tenido inter&eacute;s en un subgrupo importante de pacientes que presentan FV idiop&aacute;tica: el s&iacute;ndrome de Brugada.<sup>18</sup> En estos pacientes se ha observado que frecuentemente hay extras&iacute;stoles ventriculares que inician la FV.<sup>19</sup> Debido a la alta recurrencia de FV en este s&iacute;ndrome (hasta 37% a 3 a&ntilde;os) el DAI es la opci&oacute;n de tratamiento generalmente aceptada con lo que se mejora el pron&oacute;stico a largo plazo.<sup>20</sup> En esta serie se incluye un paciente con antecedente de 2 integrantes de su familia que sufrieron MS a edad temprana, y que contaba con las caracter&iacute;sticas electrocardiogr&aacute;ficas del s&iacute;ndrome de Brugada. Se le realiz&oacute; estudio electrofisiol&oacute;gico en el que se indujo FV, por lo que se le coloc&oacute; un DAI. En el seguimiento posterior de este paciente, a 12 meses no ha presentado a&uacute;n alguna descarga.</font></p>     <p align="justify"><font face="verdana" size="2">Las taquicardias supraventriculares pueden ocasionar descargas inapropiadas del DAI en aproximadamente 10 a 20% de los pacientes. Con los nuevos algoritmos de detecci&oacute;n de TV de estos dispositivos se ha logrado disminuir la incidencia de descargas inapropiadas a menos del 5%.<sup>21</sup> El seguimiento de los pacientes portadores de un DAI debe ser realizado por un grupo especializado de electrofisi&oacute;logos que se encarguen de vigilar algunas variables cl&iacute;nicas como los s&iacute;ntomas de taquiarritmias, la aparici&oacute;n de nuevos tipos de arritmias, la necesidad de terapia farmacol&oacute;gica concomitante. El interrogatorio del desfibrilador permite adem&aacute;s conocer algunos par&aacute;metros como el estado del generador y del electrodo y evaluar el n&uacute;mero de descargas realizadas y si &eacute;stas han sido adecuadas. Con toda esta informaci&oacute;n es posible adecuar la programaci&oacute;n del dispositivo para optimizar su funcionamiento. El consenso general es que el balance de costo/beneficio del DAI es favorable debido al marcado beneficio de la sobrevida.<sup>22</sup></font></p>     <p align="justify"><font face="verdana" size="2">En conclusi&oacute;n la implantaci&oacute;n del DAI es una medida segura y efectiva para la prevenci&oacute;n primaria y secundaria de la MS. Este dispositivo no ha modificado la mortalidad por insuficiencia card&iacute;aca de estos enfermos, pero s&iacute; la MS arr&iacute;tmica.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="Verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Referencias</b></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">1. CAPPUCCI A, BORIANI G: <i>Drugs, surgery, cardioverter&#45;defibrillator: a decision based on the clinical problem.</i> Pacing Clin Electrophysiol 1993; 6: 519&#45;526.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015869&pid=S1405-9940200200030000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">2. GILLUM RF: <i>Sudden coronary death in the United States.</i> Circulation 1989; 9: 756&#45;765.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015871&pid=S1405-9940200200030000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">3. MIROWSKI M, REID PR, MOER MM: <i>Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings.</i> N Engl J Med 1980; 303: 322&#45;324.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015873&pid=S1405-9940200200030000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">4. AKHTAR M, JAZAYERI M, SRA J, TCHOU P, ROVANG K, BLANCK Z, ET AL: <i>Implantable cardioverter defibrillator for prevention of sudden cardiac death in patients with VT and ventricular fibrillation.</i> Pacing Clin Electrophysiol 1993; 6: 511&#45;518.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015875&pid=S1405-9940200200030000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">5. TRAPPE HJ: <i>The modern implantable cardioverter&#45;defibrillator: comparing it to those of the late 1980s.</i> Am J Cardiol 1996; 8(Suppl 5): 3&#45;8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015877&pid=S1405-9940200200030000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">6. CONNOLLY SJ, YUSUF S: <i>Evaluation of the implantable cardioverter&#45;defibrillator in survivors of cardiac arrest: the need for randomized trials.</i> Am J Cardiol 1992; 69: 959&#45;962.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015879&pid=S1405-9940200200030000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">7. MYERBURG RJ, KESSLER KM, CASTELLANOS A: <i>Sudden cardiac death: structure function, and time&#45;dependence of risk.</i> Circulation 1992; 85(Suppl I): I&#45;2&#45;I&#45;10.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015881&pid=S1405-9940200200030000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">8. WILBER DJ, KOPP D, OLSHANSKY B: <i>Nonsustained ventricular tachycardia and other high&#45;risk predictors following myocardial infarction: implications for prophylactic automatic implantable cardioverter&#45;defibrillator use.</i> Prog Cardiovasc Dis 1993; 36: 179&#45;194.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015883&pid=S1405-9940200200030000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">9. <i>The antyarrhythmics versus implantable defibrillators (AVID) investigators: a comparison of antiarrhythmic&#45;drug therapy with implantable defibrillators in patients resuscitated from near fatal ventricular arrhythmias.</i> N Engl J Med 1997; 337: 1576&#45;1583.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015885&pid=S1405-9940200200030000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">10. SIEBELS J, CAPPATO R, RUPPEL R: <i>Preliminary results of the cardiac arrest study Hamburg.</i> Am J Cardiol 1993; 72: 109F&#45;113F.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015887&pid=S1405-9940200200030000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">11. MOSS AJ, HALL WJ, CANNOM DS: <i>Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia.</i> N Engl J Med 1996; 335: 1933&#45;1940.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015889&pid=S1405-9940200200030000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">12. BUXTON A, LEE K, FISHER J, JOSEPHSON M, PRYSTOWSKY E, HAFLEY G: <i>The multicenter unsustained tachycardia trial investigators. A randomized study of the prevention of sudden death in patients with coronary artery disease.</i> N Engl J Med 1999; 341: 1882&#45;1890.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015891&pid=S1405-9940200200030000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">13. BUXTON A, LEE K, FISHER J, JOSEPHSON M, PRYSTOWSKY E, HAFLEY G: <i>The multicenter unsustained tachycardia trial investigators. Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death.</i> N Engl J Med 2000; 342: 1937&#45;1945.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015893&pid=S1405-9940200200030000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">14. LINK MS, COSTEAS XF, GRIFFITH JL: <i>High incidence of appropriate implantable cardioverter&#45;defibrillator therapy in patients with syncope of unknown etiology and inducible ventricular arrhythmias.</i> J Am Coll Cardiol 1997; 29: 370&#45;375.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015895&pid=S1405-9940200200030000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">15. STRICKBERGER SA, MAN KC, DAOUD EG: <i>A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease an implantable cardioverter&#45;defibrillator.</i> Circulation 1997; 96: 1525&#45;1531.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015897&pid=S1405-9940200200030000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">16. NATALE A, SRA J, AXTELL K: <i>Ventricular fibrillation and polymorphic ventricular tachycardia with critical coronary artery stenosis: does bypass surgery suffice?</i> J Cardiovasc Electrophysiol 1994; 5: 988&#45;994.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015899&pid=S1405-9940200200030000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">17. SAXON LA, WIENER I, DELURGIO DB: <i>Implantable defibrillators for high risk patients with heart failure who are awaiting cardiac transplantation.</i> Am Heart J 1995; 130: 501&#45;506.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015901&pid=S1405-9940200200030000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">18. BRUGADA P, BRUGADA J: <i>Right bundle block, persistent ST segment elevation and sudden cardiac death: a distinct clinical and electrocardiographic syndrome. A multicenter report.</i> J Am Coll Cardiol 1992; 20: 1391&#45;1396.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015903&pid=S1405-9940200200030000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">19. KAKISHITA M, KURITA T, MATSUO K, TAGUCHI A, SUYAMA K, SHIMIZU W, ET AL: <i>Mode of onset of ventricular fibrillation in patients with Brugada Syndrome detected by implantable cardioverter defibrillator therapy.</i> J Am Coll Cardiol 2000; 36: 1646&#45;1653.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015905&pid=S1405-9940200200030000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">20. BRUGADA J, BRUGADA R, BRUGADA P: <i>Right bundle&#45;branch block and ST segment elevation in leads V1 through V3 a marker for sudden death in patients without demonstrable structural heart disease.</i> Circulation 1998; 97: 457&#45;460.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015907&pid=S1405-9940200200030000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">21. SCHAUMANN A: <i>Managing atrial tachyarrhythmias in patients with implantable cardioverter defibrillators.</i> Am J Cardiol 1999; 83: 214D&#45;217D.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015909&pid=S1405-9940200200030000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">22. GOLLOB MH, SERGER JJ: <i>Current status of the implantable cardioverter&#45;defibrillator.</i> Chest 2001; 119: 1210&#45;1221.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=1015911&pid=S1405-9940200200030000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[CAPPUCCI]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[BORIANI]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Drugs, surgery, cardioverter-defibrillator: a decision based on the clinical problem]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1993</year>
<volume>6</volume>
<page-range>519-526</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[GILLUM]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sudden coronary death in the United States]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1989</year>
<volume>9</volume>
<page-range>756-765</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MIROWSKI]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[REID]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[MOER]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1980</year>
<volume>303</volume>
<page-range>322-324</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[AKHTAR]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[JAZAYERI]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[SRA]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[TCHOU]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[ROVANG]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[BLANCK]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantable cardioverter defibrillator for prevention of sudden cardiac death in patients with VT and ventricular fibrillation]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1993</year>
<volume>6</volume>
<page-range>511-518</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[TRAPPE]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The modern implantable cardioverter-defibrillator: comparing it to those of the late 1980s]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1996</year>
<volume>8</volume>
<numero>^s5</numero>
<issue>^s5</issue>
<supplement>5</supplement>
<page-range>3-8</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[CONNOLLY]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[YUSUF]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of the implantable cardioverter-defibrillator in survivors of cardiac arrest: the need for randomized trials]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1992</year>
<volume>69</volume>
<page-range>959-962</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MYERBURG]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[KESSLER]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[CASTELLANOS]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sudden cardiac death: structure function, and time-dependence of risk]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1992</year>
<volume>85</volume>
<numero>^sI</numero>
<issue>^sI</issue>
<supplement>I</supplement>
<page-range>I-2 - I-10</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[WILBER]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[KOPP]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[OLSHANSKY]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nonsustained ventricular tachycardia and other high-risk predictors following myocardial infarction: implications for prophylactic automatic implantable cardioverter-defibrillator use]]></article-title>
<source><![CDATA[Prog Cardiovasc Dis]]></source>
<year>1993</year>
<volume>36</volume>
<page-range>179-194</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[The antyarrhythmics versus implantable defibrillators (AVID) investigators: a comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near fatal ventricular arrhythmias]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1997</year>
<volume>337</volume>
<page-range>1576-1583</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[SIEBELS]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[CAPPATO]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[RUPPEL]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preliminary results of the cardiac arrest study Hamburg]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1993</year>
<volume>72</volume>
<page-range>109F-113F</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MOSS]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[HALL]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[CANNOM]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1996</year>
<volume>335</volume>
<page-range>1933-1940</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BUXTON]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[LEE]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[FISHER]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[JOSEPHSON]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[PRYSTOWSKY]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[HAFLEY]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The multicenter unsustained tachycardia trial investigators. A randomized study of the prevention of sudden death in patients with coronary artery disease]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>1999</year>
<volume>341</volume>
<page-range>1882-1890</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BUXTON]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[LEE]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[FISHER]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[JOSEPHSON]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[PRYSTOWSKY]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[HAFLEY]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The multicenter unsustained tachycardia trial investigators. Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death]]></article-title>
<source><![CDATA[N Engl J Med]]></source>
<year>2000</year>
<volume>342</volume>
<page-range>1937-1945</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[LINK]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[COSTEAS]]></surname>
<given-names><![CDATA[XF]]></given-names>
</name>
<name>
<surname><![CDATA[GRIFFITH]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High incidence of appropriate implantable cardioverter-defibrillator therapy in patients with syncope of unknown etiology and inducible ventricular arrhythmias]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1997</year>
<volume>29</volume>
<page-range>370-375</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[STRICKBERGER]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[MAN]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[DAOUD]]></surname>
<given-names><![CDATA[EG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease an implantable cardioverter-defibrillator]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1997</year>
<volume>96</volume>
<page-range>1525-1531</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[NATALE]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[SRA]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[AXTELL]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ventricular fibrillation and polymorphic ventricular tachycardia with critical coronary artery stenosis: does bypass surgery suffice]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>1994</year>
<volume>5</volume>
<page-range>988-994</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[SAXON]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[WIENER]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[DELURGIO]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantable defibrillators for high risk patients with heart failure who are awaiting cardiac transplantation]]></article-title>
<source><![CDATA[Am Heart J]]></source>
<year>1995</year>
<volume>130</volume>
<page-range>501-506</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BRUGADA]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[BRUGADA]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right bundle block, persistent ST segment elevation and sudden cardiac death: a distinct clinical and electrocardiographic syndrome. A multicenter report]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>1992</year>
<volume>20</volume>
<page-range>1391-1396</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[KAKISHITA]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[KURITA]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[MATSUO]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[TAGUCHI]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[SUYAMA]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[SHIMIZU]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mode of onset of ventricular fibrillation in patients with Brugada Syndrome detected by implantable cardioverter defibrillator therapy]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2000</year>
<volume>36</volume>
<page-range>1646-1653</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BRUGADA]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[BRUGADA]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[BRUGADA]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Right bundle-branch block and ST segment elevation in leads V1 through V3 a marker for sudden death in patients without demonstrable structural heart disease]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1998</year>
<volume>97</volume>
<page-range>457-460</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[SCHAUMANN]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Managing atrial tachyarrhythmias in patients with implantable cardioverter defibrillators]]></article-title>
<source><![CDATA[Am J Cardiol]]></source>
<year>1999</year>
<volume>83</volume>
<page-range>214D-217D</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[GOLLOB]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
<name>
<surname><![CDATA[SERGER]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Current status of the implantable cardioverter-defibrillator]]></article-title>
<source><![CDATA[Chest]]></source>
<year>2001</year>
<volume>119</volume>
<page-range>1210-1221</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>