<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0484-7903</journal-id>
<journal-title><![CDATA[Revista mexicana de anestesiología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. anestesiol.]]></abbrev-journal-title>
<issn>0484-7903</issn>
<publisher>
<publisher-name><![CDATA[Colegio Mexicano de Anestesiología A.C.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0484-79032019000200129</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Fuego en el quirófano. Reporte de un caso]]></article-title>
<article-title xml:lang="en"><![CDATA[Fire in the operating room. A case report]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Salim-Terreros]]></surname>
<given-names><![CDATA[Anahí]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López-Castruita]]></surname>
<given-names><![CDATA[Victor Manuel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bautista-Guzmán]]></surname>
<given-names><![CDATA[Iván]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Centro de Especialidades Medicas del Estado de Veracruz Dr. Rafael Lucio Departamento de Anestesiología ]]></institution>
<addr-line><![CDATA[Xalapa Veracruz]]></addr-line>
<country>México</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Centro de Especialidades Medicas del Estado de Veracruz Dr. Rafael Lucio Departamento de Anestesiología ]]></institution>
<addr-line><![CDATA[Xalapa Veracruz]]></addr-line>
<country>México</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Centro de Especialidades Medicas del Estado de Veracruz Dr. Rafael Lucio Departamento de Anestesiología ]]></institution>
<addr-line><![CDATA[Xalapa Veracruz]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2019</year>
</pub-date>
<volume>42</volume>
<numero>2</numero>
<fpage>129</fpage>
<lpage>132</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0484-79032019000200129&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0484-79032019000200129&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0484-79032019000200129&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: Existen diversos reportes en la literatura de eventos adversos dentro de quirófano, éstos pueden ser de distinta naturaleza; uno de ellos es la presencia de fuego en el quirófano, el cual no se aleja de nuestra realidad, ya que el uso de oxígeno suplementario propicia un ambiente rico en oxidante y al hacer contacto con otros dispositivos de uso común en cirugía, pueden originar un incendio. Reportamos un caso de fuego en el quirófano, en el que participaron elementos que se han visto relacionados, como el electrocauterio, oxígeno, vello y campos quirúrgicos, que resultó en quemaduras de segundo grado en el 30% de la superficie corporal total de la paciente que se sometía a cirugía. Se hizo una revisión bibliográfica de la evidencia existente al respecto, así como un repaso al algoritmo de la ASA para la prevención y manejo del fuego en el quirófano, el cual es de relevancia para el anestesiólogo y todos los profesionistas que conforman el equipo quirúrgico.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: There are several reports in the literature of adverse events within the operating room, these may be of a different nature; one of them is the presence of fire in the operating room, which does not depart from our reality, since the use of supplemental oxygen promotes an environment rich in oxidant and when contacting other devices commonly used in surgery, can cause a fire. We report a case of fire in the operating room, in which elements that have been related, such as electrocautery, oxygen, hair, and surgical fields, were involved and that resulted in 2nd degree burns in 30% total body surface of the patient who underwent surgery. A literature review of the existing evidence was made, as well as a review of the ASA algorithm for the prevention and management of fire in the operating room, which is of relevance to the anesthesiologist and all professionals who make up the surgical team.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Fuego]]></kwd>
<kwd lng="es"><![CDATA[evento adverso]]></kwd>
<kwd lng="es"><![CDATA[manejo de crisis]]></kwd>
<kwd lng="es"><![CDATA[manejo de riesgos]]></kwd>
<kwd lng="es"><![CDATA[seguridad del paciente]]></kwd>
<kwd lng="es"><![CDATA[quemaduras]]></kwd>
<kwd lng="en"><![CDATA[Fire]]></kwd>
<kwd lng="en"><![CDATA[adverse event]]></kwd>
<kwd lng="en"><![CDATA[crisis management]]></kwd>
<kwd lng="en"><![CDATA[risk management]]></kwd>
<kwd lng="en"><![CDATA[patient safety]]></kwd>
<kwd lng="en"><![CDATA[burns]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hart]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
<name>
<surname><![CDATA[Yajnik]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ashford]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Springer]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Harvey]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Operating room fire safety]]></article-title>
<source><![CDATA[Ochsner J]]></source>
<year>2011</year>
<volume>11</volume>
<page-range>37-42</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Eriksson]]></surname>
<given-names><![CDATA[LI]]></given-names>
</name>
<name>
<surname><![CDATA[Fleisher]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<source><![CDATA[Miller anestesia]]></source>
<year>2015</year>
<edition>8</edition>
<publisher-loc><![CDATA[España ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier Health Sciences]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Apfelbaum]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Caplan]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
<name>
<surname><![CDATA[Barker]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Connis]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Cowles]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Practice advisory for the prevention and management of operating room fires]]></article-title>
<source><![CDATA[Anesthesiology]]></source>
<year>2013</year>
<volume>118</volume>
<page-range>271-90</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<source><![CDATA[Recommendations to Reduce Surgical Fires and Related Patient Injury: FDA safety communication]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mehta]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Bhananker]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Posner]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Domino]]></surname>
<given-names><![CDATA[KB]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Operating room fires: a closed claims analysis]]></article-title>
<source><![CDATA[Anesthesiology]]></source>
<year>2013</year>
<volume>118</volume>
<page-range>1133-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Del Rosario]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Errando]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
<name>
<surname><![CDATA[García del Valle]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Fuego en el quirófano: mito o realidad?; y... qué podemos aprender?]]></article-title>
<source><![CDATA[Rev Esp Anestesiol Reanim]]></source>
<year>2010</year>
<volume>57</volume>
<page-range>133-5</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaye]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Kolinsky]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Urman]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Management of a fire in the operating room]]></article-title>
<source><![CDATA[J Anesth]]></source>
<year>2014</year>
<volume>28</volume>
<page-range>279-87</page-range></nlm-citation>
</ref>
</ref-list>
</back>