<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-9532</journal-id>
<journal-title><![CDATA[Revista mexicana de ingeniería biomédica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. ing. bioméd]]></abbrev-journal-title>
<issn>0188-9532</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Mexicana de Ingeniería Biomédica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-95322018000100021</article-id>
<article-id pub-id-type="doi">10.17488/rmib.39.1.2</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Caracterización de la Lámpara Flash-LED: EBNeuro Usada para Adquirir Potenciales Evocados Visuales en Ratas]]></article-title>
<article-title xml:lang="en"><![CDATA[Characterization of the Flash-LED Lamp: EBNeuro Used to Acquired Visual Evoked Potentials in Rats]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ortiz-Arzate]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Camacho-López]]></surname>
<given-names><![CDATA[M. A.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ballesteros-Zebadua]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Franco-Pérez]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Treviño-Palacios]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Oros-Pantoja]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Autónoma del Estado de México  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Instituto Nacional de Neurología y Neurocirugía  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>México</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Instituto Nacional de Astrofísica, Óptica y Electrónica  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2018</year>
</pub-date>
<volume>39</volume>
<numero>1</numero>
<fpage>21</fpage>
<lpage>28</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-95322018000100021&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-95322018000100021&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-95322018000100021&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen: La señal de la amplitud en análisis de Potenciales Evocados Visuales (PEVs) es una variable que depende del tipo y posición de los electrodos, de la fuente, del estímulo y por consecuente, de la intensidad luminosa por lo que es fundamental reportarla para cada diseño experimental y así, garantizar su reproducibilidad. El objetivo de este trabajo es caracterizar una lámpara con 96 LEDs para la adquisición de PEVs en ratas. Se midió la iluminancia y la intensidad luminosa promedio en un sistema espacial XYZ de 8 cm3 aplicable a un sistema estereotáxico para la fijación de ratas. Se realizaron desplazamientos cada 2 cm en cada plano. Se observó que debido a la distribución geométrica de los LEDs la distribución de la iluminancia no sigue la ley del inverso cuadrado, ya que aumenta conforme la lámpara se aleja. Finalmente, se seleccionó una coordenada para la colocación del ojo de la rata empleando una intensidad luminosa promedio para la adquisición del PEV de 1.043 cd e iluminancia de 128.77 luxes a una distancia ojo-lámpara de 9 cm. Una vez caracterizada la intensidad luminosa y de acuerdo con los PEVs obtenidos, esta lámpara puede utilizarse para estudios PEV en ratas en investigaciones posteriores.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract: Signal amplitude for recordings of Visual Evoked Potentials (VEPs) is a variable dependent on the type and position of the electrodes, the source, the stimulus and consequently the luminous intensity; therefore, it is relevant to report it to assure experimental reproducibility. The objective of this work is to characterize flash lamp with 96 LEDs in order to perform the acquisition of VEPs in rats. We measure the illuminance and mean light intensity on space system XYZ of 8 cm3 corresponding to a stereotaxic frame for rodents. Displacements were performed every 2 cm in each plane. Because of the geometric distribution of the LEDs in the EBNeuro lamp the spatial distribution of illuminance does not follow the law of the inverse square, because the illuminance increases as the lamp goes away. Finally a spatial coordinate was selected for the rat eye positioning were the mean luminous intensity was 1.043 cd and 128.77 luxes of illuminance at an eye-lamp distance of 9 cm. According to the obtained VEPs and spatial characterization this lamp can be used for acquire of recordings PEV in rats for further investigations.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Lámpara Flash-LED]]></kwd>
<kwd lng="es"><![CDATA[iluminancia]]></kwd>
<kwd lng="es"><![CDATA[intensidad luminosa]]></kwd>
<kwd lng="es"><![CDATA[Potenciales Evocados Visuales]]></kwd>
<kwd lng="es"><![CDATA[ratas]]></kwd>
<kwd lng="en"><![CDATA[Flash-LED lamp]]></kwd>
<kwd lng="en"><![CDATA[illuminance]]></kwd>
<kwd lng="en"><![CDATA[luminous intensity]]></kwd>
<kwd lng="en"><![CDATA[Visual Evoked Potentials]]></kwd>
<kwd lng="en"><![CDATA[rats]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Charng]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Nquyen]]></surname>
<given-names><![CDATA[C.T.]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Dang]]></surname>
<given-names><![CDATA[T.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Vinqrys]]></surname>
<given-names><![CDATA[A.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Fish]]></surname>
<given-names><![CDATA[R.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Conscious wireless electroretinogram and visual evoked potentials in rats]]></article-title>
<source><![CDATA[Public Library of Science]]></source>
<year>2013</year>
<volume>8</volume>
</nlm-citation>
</ref>
<ref id="B2">
<label>2.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[You]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Klistorner]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Thie]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Graham]]></surname>
<given-names><![CDATA[S.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Improving reproducibility of VEP recording in rats: electrodes, stimulus source and peak analysis]]></article-title>
<source><![CDATA[Documenta ophthalmologica. Advances in ophthalmology]]></source>
<year>2011</year>
<volume>123</volume>
<page-range>109-19</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Creutzfeldt]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Maekawa]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Hosli]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Forms of spontaneous and evoked postsynaptic potential of cortical nerve cells]]></article-title>
<source><![CDATA[Progress in brain research]]></source>
<year>1969</year>
<volume>31</volume>
<page-range>X 265-73</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[You]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Thie]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Klistorner]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gupta]]></surname>
<given-names><![CDATA[V.K.]]></given-names>
</name>
<name>
<surname><![CDATA[Graham]]></surname>
<given-names><![CDATA[S.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Normalization of visual evoked potentials using underlying electroencephalogram levels improves amplitude reproducibility in rats]]></article-title>
<source><![CDATA[Investigative ophthalmology &amp; visual science]]></source>
<year>2012</year>
<volume>53</volume>
<page-range>1473-8</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nguyen]]></surname>
<given-names><![CDATA[C.T.]]></given-names>
</name>
<name>
<surname><![CDATA[Tsai]]></surname>
<given-names><![CDATA[T.I.]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Vingrys]]></surname>
<given-names><![CDATA[A.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Bui]]></surname>
<given-names><![CDATA[B.V.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Simultaneous recordings of electroretinography and visual evoked potentials in anesthetized rats]]></article-title>
<source><![CDATA[Journal of visualized experiments: JoVE]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B6">
<label>6.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarkadi]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Inczefly]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Simultaneous quantitative evaluation of visual evoked responses and background EEG activity in rat: normative data]]></article-title>
<source><![CDATA[Journal of pharmacological and toxicological methods]]></source>
<year>1996</year>
<volume>35</volume>
<page-range>145-51</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Göçmen]]></surname>
<given-names><![CDATA[A.Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Celikbilek]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Hac&#305;o&#287;lu]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Tan&#305;k]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[A&#287;ar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Yarg&#305;co&#287;lu]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The relationship between oxidative stress markerkers and visual evoked potentials in different hypertension models]]></article-title>
<source><![CDATA[Anadolu kardiyoloji dergisi]]></source>
<year>2014</year>
<volume>14</volume>
<page-range>498-504</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yan]]></surname>
<given-names><![CDATA[H.Q.]]></given-names>
</name>
<name>
<surname><![CDATA[Mazow]]></surname>
<given-names><![CDATA[M.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Dafny]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Monocular visual deprivation at the critical period modulates photic evoked responses]]></article-title>
<source><![CDATA[Brain research bulletin]]></source>
<year>1995</year>
<volume>36</volume>
<page-range>545-8</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Iwamura]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Fujii]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Kamei]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The effects of certain H1-antagonists on visual evoked potential in rats]]></article-title>
<source><![CDATA[Brain research bulletin]]></source>
<year>2003</year>
<volume>61</volume>
<page-range>393-8</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haynes]]></surname>
<given-names><![CDATA[J.R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Radiaton resulting from the recombination of holes and electrons in silicon]]></article-title>
<source><![CDATA[Physical review]]></source>
<year>1956</year>
<volume>101</volume>
<page-range>1676-8</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11.</label><nlm-citation citation-type="">
<source><![CDATA[Descripción del medidor digital de luminosidad (luxómetro) HER-410]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B12">
<label>12.</label><nlm-citation citation-type="">
<source><![CDATA[Descripción de la lámpara Flash EBNeuro]]></source>
<year></year>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
