<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-4999</journal-id>
<journal-title><![CDATA[Revista internacional de contaminación ambiental]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Int. Contam. Ambient]]></abbrev-journal-title>
<issn>0188-4999</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Instituto de Ciencias de la Atmósfera y Cambio Climático]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-49992016000300315</article-id>
<article-id pub-id-type="doi">10.20937/RICA.2016.32.03.06</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Evaluación de la sustentabilidad de instalaciones solares con colectores de placa plana y tubos evacuados]]></article-title>
<article-title xml:lang="en"><![CDATA[Sustainability assessment of solar installations with flat plate and evacuated tube collectors]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Albizzati]]></surname>
<given-names><![CDATA[Enrique]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Nacional del Litoral Facultad de Ingeniería Química ]]></institution>
<addr-line><![CDATA[Santa Fe ]]></addr-line>
<country>Argentina</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>08</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>08</month>
<year>2016</year>
</pub-date>
<volume>32</volume>
<numero>3</numero>
<fpage>315</fpage>
<lpage>322</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-49992016000300315&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-49992016000300315&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-49992016000300315&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN: La generación y el uso de los recursos energéticos producen efectos ambientales, de modo que en la evaluación de la aplicación de la energía solar es necesario considerar el ciclo completo de los aprovechamientos a través del análisis del ciclo de vida. En este trabajo se calculan indicadores de sustentabilidad para el calentamiento solar de agua, con electricidad (SE) y gas licuado (SGL) como energía auxiliar. Los dispositivos con colectores de placa plana (PP) tienen valores más bajos de la contribución solar a la demanda y la eficiencia térmica (84.3 % y 34 %), mientras que con tubos evacuados (TE) ambos valores son 89.3 % y 46.3 % respectivamente. La energía solar térmica generada y las emisiones evitadas se determinan descontando sobre los valores brutos, el consumo de energía y las emisiones debido a los requerimientos específicos para la recogida de la radiación solar. La energía térmica total máxima generada es 189 161.6 MJ (SGL-PP) y la mitigación máxima total es 21 375.2 kg CO2 eq (SE-PP). La energía térmica generada por año y por m2 de colector es más alta con gas licuado y el colector evacuado (SGL-TE). Sin embargo este tipo de colector maximiza las mitigaciones por año y por m2 usando electricidad (SE-TE). Los periodos de amortización energética de las instalaciones se encuentran entre 8.1 (SGL-TE) y 12.3 meses (SE-PP), mientras que los periodos de amortización ambientales entre 5.5 (SE-TE) y 12.1 (SGL-PP) meses.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT: The generation and use of energy resources produce environmental effects, so that in the assessment of the application of solar energy is necessary to consider the complete cycle of the exploitation through the life cycle analysis. In this work sustainability indicators for solar installations of water heating, to use electricity (SE) and liquified gas (SLG) as auxiliary energy are calculated. Devices with flat plate collectors (FP) have lower values of solar contribution to the demand and thermal efficiency (84.3% and 34.0%) however, with evacuated tubes (ET) are 89.3% and 46.3%, respectively. The solar thermal energy generated and the emissions avoided are determined by discounting on gross values of energy consumption and emissions due to the specific requirements for the collection of solar radiation. The maximum total thermal energy generated is 189 161.6 MJ (SLG-FP), and the maximum total mitigation is 21 375.2 kg CO2 eq (SE-FP). The energy generated from the collector per year and per square meter is higher with liquefied gas and evacuated collector (SLG-ET). However this type of collector maximizes the mitigations per year and per square meter using electricity (SE-ET). The energy payback periods for these technologies are among 8.1 (SLG-ET) and 12.3 (SE-FP) months, but the environmental paybacks are among 5.5 (SE-ET) and 12.1 (SLG-FP) months.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[solar]]></kwd>
<kwd lng="es"><![CDATA[calentamiento]]></kwd>
<kwd lng="es"><![CDATA[agua]]></kwd>
<kwd lng="es"><![CDATA[energía]]></kwd>
<kwd lng="es"><![CDATA[emisiones]]></kwd>
<kwd lng="en"><![CDATA[solar]]></kwd>
<kwd lng="en"><![CDATA[heating]]></kwd>
<kwd lng="en"><![CDATA[water]]></kwd>
<kwd lng="en"><![CDATA[energy]]></kwd>
<kwd lng="en"><![CDATA[emissions]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albizzati]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Energía solar térmica: principios básicos y aplicaciones tecnológicas]]></source>
<year>2012</year>
<month>a</month>
<publisher-loc><![CDATA[Santa Fe, Argentina ]]></publisher-loc>
<publisher-name><![CDATA[Centro de Publicaciones de la Universidad Nacional del Litoral]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Albizzati]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Cálculos de la energía generada y la mitigación de emisiones de gases en instalaciones para calentamiento solar de agua]]></source>
<year>2012</year>
<month>b</month>
<volume>31</volume>
<page-range>9-16</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alcorn]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Embodied energy and CO2 coefficients for NZ buildings materials. Centre for Building Performance Research]]></source>
<year>2003</year>
<publisher-loc><![CDATA[Nueva Zelanda ]]></publisher-loc>
<publisher-name><![CDATA[Victoria University of Wellington]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Life cycle assessment of a solar thermal collector]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ardente]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Beccali]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Cellura]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Lo Brano]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
</person-group>
<source><![CDATA[Renew. Energ.]]></source>
<year>2005</year>
<volume>30</volume>
<page-range>1031-54</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="book">
<collab>ANSI/ASHRAE 93</collab>
<source><![CDATA[Methods of testing to determine the thermal performance of solar collectors]]></source>
<year>2010</year>
<publisher-loc><![CDATA[Atlanta, EUA ]]></publisher-loc>
<publisher-name><![CDATA[American National Standards Institute /American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="">
<collab>Consejo Mundial de Energía</collab>
<source><![CDATA[Comparison of energy systems using life cycle assessment]]></source>
<year>2004</year>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Consoli]]></surname>
<given-names><![CDATA[Allen D.]]></given-names>
</name>
<name>
<surname><![CDATA[Boustead I.]]></surname>
<given-names><![CDATA[Fava J.]]></given-names>
</name>
<name>
<surname><![CDATA[Franklin W.]]></surname>
<given-names><![CDATA[Jensen A. de Oude N.]]></given-names>
</name>
<name>
<surname><![CDATA[Parrish R.]]></surname>
<given-names><![CDATA[Perriman R.]]></given-names>
</name>
<name>
<surname><![CDATA[Postlethwaite D.]]></surname>
<given-names><![CDATA[Quay B.]]></given-names>
</name>
<name>
<surname><![CDATA[Séguin J.]]></surname>
<given-names><![CDATA[Vigon B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Guidelines for life-cycle assessment: a 'code of practice']]></source>
<year>1993</year>
<edition>1</edition>
<publisher-loc><![CDATA[Pensacola, EUA ]]></publisher-loc>
<publisher-name><![CDATA[SETAC Press (Society of Environmental Toxicology and Chemistry)]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Duffie]]></surname>
<given-names><![CDATA[J. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Beckman]]></surname>
<given-names><![CDATA[W. A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Solar engineering of thermal processes]]></source>
<year>2013</year>
<edition>4</edition>
<publisher-loc><![CDATA[Hoboken, EUA ]]></publisher-loc>
<publisher-name><![CDATA[J. Wiley and Sons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Domestic solar ther-mal water heating: a sustainable option for the UK ?]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greening]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Azapagic]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Renew. Energ.]]></source>
<year>2014</year>
<volume>63</volume>
<page-range>23-36</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hammond]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Jones]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Embodied carbon. The inventory of carbon and energy (ICE)]]></source>
<year>2011</year>
<publisher-loc><![CDATA[Berkshire, Reino Unido ]]></publisher-loc>
<publisher-name><![CDATA[University of Bath-BSRIA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Economic and environ-mental life cycle analysis of solar hot water systems in the United States]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hang]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Qu]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<source><![CDATA[Energ. Buildings]]></source>
<year>2012</year>
<volume>45</volume>
<page-range>181-8</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ihobe]]></surname>
</name>
</person-group>
<source><![CDATA[Análisis de ciclo de vida y huella de carbono: dos maneras de medir el impacto ambiental de un producto]]></source>
<year>2009</year>
<publisher-loc><![CDATA[Gobierno Vasco, España ]]></publisher-loc>
<publisher-name><![CDATA[Sociedad Pública de Gestión Ambiental]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="book">
<collab>IPCC</collab>
<source><![CDATA[Cambio climático 2013: Bases físicas. Resumen para responsables de políticas. Contribución del grupo de trabajo I al quinto informe de evaluación del grupo intergubernamental de expertos sobre el cambio climático]]></source>
<year>2013</year>
<publisher-name><![CDATA[Grupo Intergubernamental de Expertos sobre el Cambio Climático]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kalogirou]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Solar energy engineering: processes and systems]]></source>
<year>2009</year>
<month>a</month>
<publisher-loc><![CDATA[Burlington, EUA ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier/Academic Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Thermal performance, economic and environmental life cycle analysis of thermosiphon solar water heaters]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kalogirou]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Sol. Energy]]></source>
<year>2009</year>
<month>b</month>
<volume>83</volume>
<page-range>39-48</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Life cycle environ-mental impact assessment of a solar water heater]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koroneos]]></surname>
<given-names><![CDATA[C. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Nanaki]]></surname>
<given-names><![CDATA[E. A.]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Clean. Prod.]]></source>
<year>2012</year>
<volume>37</volume>
<page-range>154-61</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Life cycle analysis of a building-integrated solar thermal collector, based on embodied energy and embodied carbon methodologies]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lamnatou]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Notton]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Chemisana]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Cristofari]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Energ. Buildings]]></source>
<year>2014</year>
<volume>4</volume>
<page-range>378-87</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="book">
<collab>NASA</collab>
<source><![CDATA[Surface meteorology and solar energy. A renewable energy resource web site]]></source>
<year>2014</year>
<publisher-name><![CDATA[Atmospheric Science Data Center]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="">
<collab>OMM</collab>
<source><![CDATA[Declaración de la Organización Meteorológica Mundial sobre el estado del clima mundial en 2011]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="book">
<collab>REN 21</collab>
<source><![CDATA[Renewables 2015 global status report. Annual Reporting on Renewables: Ten years of excellence]]></source>
<year>2015</year>
<publisher-name><![CDATA[REN 21]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Life cycle analysis of a thermal solar installation at a rural house in Valladolid (Spain)]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rey-Martínez]]></surname>
<given-names><![CDATA[F. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Velasco-Gómez]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Martín-Gil]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Navas Gracia]]></surname>
</name>
<name>
<surname><![CDATA[Hernández Navarro]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Environ. Eng. Sci.]]></source>
<year>2008</year>
<volume>25</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>713-24</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
