<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0034-8376</journal-id>
<journal-title><![CDATA[Revista de investigación clínica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. invest. clín.]]></abbrev-journal-title>
<issn>0034-8376</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0034-83762019000200085</article-id>
<article-id pub-id-type="doi">10.24875/ric.18002754</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Clinical and Biomedical Applications of Surface Plasmon Resonance Systems]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Meza-Sánchez]]></surname>
<given-names><![CDATA[David E.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Maravillas-Montero]]></surname>
<given-names><![CDATA[José L.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Nacional Autónoma de México Red de Apoyo a la Investigación ]]></institution>
<addr-line><![CDATA[Mexico City ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2019</year>
</pub-date>
<volume>71</volume>
<numero>2</numero>
<fpage>85</fpage>
<lpage>90</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0034-83762019000200085&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0034-83762019000200085&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0034-83762019000200085&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Surface plasmon resonance (SPR)-based biosensors offer superior analytical features such as simplicity, sensitivity, and specificity when compared to conventional methods in clinical analyses. In addition, they deliver real-time monitoring of label-free analytes with high-throughput approaches requiring little sample pretreatment that allows the analysis of virtually every clinical sample type to determine the amount and/or activity of any molecule of interest. Accordingly, SPR emerges as a novel, efficient, powerful, and relatively low-cost alternative tool for routine clinical analysis, opening also new horizons for developments in personalized medicine applied to diagnostics or therapeutics’ monitoring.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Surface plasmon resonance]]></kwd>
<kwd lng="en"><![CDATA[Biomarker]]></kwd>
<kwd lng="en"><![CDATA[Clinical diagnostics]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rich]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Myszka]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Advances in surface plasmon resonance biosensor analysis]]></article-title>
<source><![CDATA[Curr Opin Biotechnol]]></source>
<year>2000</year>
<volume>11</volume>
<page-range>54-61</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Malmqvist]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[BIACORE:an affinity biosensor system for characterization of biomolecular interactions]]></article-title>
<source><![CDATA[Biochem Soc Trans]]></source>
<year>1999</year>
<volume>27</volume>
<page-range>335-40</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mariani]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Minunni]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface plasmon resonance applications in clinical analysis]]></article-title>
<source><![CDATA[Anal Bioanal Chem]]></source>
<year>2014</year>
<volume>406</volume>
<page-range>2303-23</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Fan]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Microfluidic surface plasmon resonance sensors:from principles to point-of-care applications]]></article-title>
<source><![CDATA[Sensors (Basel)]]></source>
<year>2016</year>
<volume>16</volume>
<page-range>E1175</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yanase]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hiragun]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ishii]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface plasmon resonance for cell-based clinical diagnosis]]></article-title>
<source><![CDATA[Sensors (Basel)]]></source>
<year>2014</year>
<volume>14</volume>
<page-range>4948-59</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergwerff]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[van Knapen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface plasmon resonance biosensors for detection of pathogenic microorganisms:strategies to secure food and environmental safety]]></article-title>
<source><![CDATA[J AOAC Int]]></source>
<year>2006</year>
<volume>89</volume>
<page-range>826-31</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wittenberg]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wootla]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Jordan]]></surname>
<given-names><![CDATA[LR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Applications of SPR for the characterization of molecules important in the pathogenesis and treatment of neurodegenerative diseases]]></article-title>
<source><![CDATA[Expert Rev Neurother]]></source>
<year>2014</year>
<volume>14</volume>
<page-range>449-63</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Masson]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Surface plasmon resonance clinical biosensors for medical diagnostics]]></article-title>
<source><![CDATA[ACS Sens]]></source>
<year>2017</year>
<volume>2</volume>
<page-range>16-30</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ferhan]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Jackman]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Nanoplasmonic sensors for detecting circulating cancer biomarkers]]></article-title>
<source><![CDATA[Adv Drug Deliv Rev]]></source>
<year>2018</year>
<volume>125</volume>
<page-range>48-77</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gunn 3rd]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Sealey]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Jamali]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[From the bench to clinical practice:understanding the challenges and uncertainties in immunogenicity testing for biopharmaceuticals]]></article-title>
<source><![CDATA[Clin Exp Immunol]]></source>
<year>2016</year>
<volume>184</volume>
<page-range>137-46</page-range></nlm-citation>
</ref>
</ref-list>
</back>