<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1665-2738</journal-id>
<journal-title><![CDATA[Revista mexicana de ingeniería química]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Mex. Ing. Quím]]></abbrev-journal-title>
<issn>1665-2738</issn>
<publisher>
<publisher-name><![CDATA[Universidad Autónoma Metropolitana, División de Ciencias Básicas e Ingeniería]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1665-27382011000200010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Revisión de variables de diseño y condiciones de operación en la electrocoagulación]]></article-title>
<article-title xml:lang="en"><![CDATA[Review of design variables and operation conditions in electrocoagulation]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Piña-Soberanis]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martín-Domínguez]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González-Ramírez]]></surname>
<given-names><![CDATA[C.A.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Prieto-García]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guevara-Lara]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-Espinoza]]></surname>
<given-names><![CDATA[J.E.]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Mexicano de Tecnología del Agua  ]]></institution>
<addr-line><![CDATA[Jiutepec Morelos]]></addr-line>
<country>México</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Autónoma del Estado de Hidalgo Centro de Investigaciones Químicas ]]></institution>
<addr-line><![CDATA[Pachuca de Soto Hidalgo]]></addr-line>
<country>México</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad Nacional Autónoma de México Facultad de Ingeniería ]]></institution>
<addr-line><![CDATA[México ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>08</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>08</month>
<year>2011</year>
</pub-date>
<volume>10</volume>
<numero>2</numero>
<fpage>257</fpage>
<lpage>271</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1665-27382011000200010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1665-27382011000200010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1665-27382011000200010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[En este documento se presenta una revisión bibliográfica sobre los fundamentos teóricos más importantes de la electrocoagulación, se analizan algunos diseños y se muestran los resultados más relevantes al aplicarla al tratamiento de agua para la remoción de diversos contaminantes de origen orgánico e inorgánico. Se enumeran algunas de sus ventajas con respecto a la coagulación química, se hace un análisis comparativo de los diseños experimentales utilizados, así como de las metodologías aplicadas, a fin de poder identificar las principales variables que intervienen en los mecanismos de remoción, tales como: la densidad de corriente; el tipo de material, tamaño y distancia en los electrodos; el tipo de conexiones utilizadas; el amperaje y voltaje aplicado; el pH, temperatura y conductividad del agua; el tiempo de residencia y el tipo de flujo utilizado. De la literatura especializada que fue consultada se concluye que los mecanismos que intervienen en la electrocoagulación no han sido aún claramente entendidos y hay pocas consideraciones de los factores que influyen en la efectiva remoción de especies iónicas, especialmente iones metálicos en el agua.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[This document presents a bibliogr aphical review o f the most important theoretical principles on electrocoagulation; it also analyzes some designs and shows the most relevant results of electrocoagulation, as applied to the treatment of water for the purpose of eliminating several organic and inorganic pollutants. Some advantages of chemical coagulation are listed. Additionally, a comparative analysis of the experimental designs used and of the applied methodologies is made, so as to be able to identify the main variables that operate in removal mechanisms, such as current density, type of material used on the electrodes and their size, distance between electrodes, type of connections used, applied amperage and voltage, pH, temperature and water conductivity, as well as residence time and type of flow used. The specialized literature that was consulted shows that the mechanisms of electrocoagulation have not yet be en clearly understood and thereis little consideration of the factors that influence the effective removal of ionic species, especially metallic ions in water.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[electrocoagulación]]></kwd>
<kwd lng="es"><![CDATA[electrodos]]></kwd>
<kwd lng="es"><![CDATA[tratamiento de agua]]></kwd>
<kwd lng="es"><![CDATA[diseño]]></kwd>
<kwd lng="es"><![CDATA[iones metálicos]]></kwd>
<kwd lng="en"><![CDATA[electrocoagulation]]></kwd>
<kwd lng="en"><![CDATA[electrodes]]></kwd>
<kwd lng="en"><![CDATA[water treatment]]></kwd>
<kwd lng="en"><![CDATA[design]]></kwd>
<kwd lng="en"><![CDATA[metallic ions]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Ingenier&iacute;a ambiental </font></p>     <p align="justify"><font face="verdana" size="4">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Revisi&oacute;n de variables de dise&ntilde;o y condiciones de operaci&oacute;n en la electrocoagulaci&oacute;n</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="3"><b>Review of design variables and operation conditions in electrocoagulation</b></font></p>     <p align="center"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>M. Pi&ntilde;a&#150;Soberanis<sup>1</sup>*, A. Mart&iacute;n&#150;Dom&iacute;nguez<sup>1</sup>, C.A. Gonz&aacute;lez&#150;Ram&iacute;rez<sup>2</sup>, F. Prieto&#150;Garc&iacute;a<sup>2</sup>, A. Guevara&#150;Lara<sup>2</sup> y J.E. Garc&iacute;a&#150;Espinoza<sup>3</sup></b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i><sup>1</sup> Instituto Mexicano de Tecnolog&iacute;a del Agua (IMTA), Jiutepec, Morelos, M</i>&eacute;<i>xico. *Autor para la correspondencia. E&#150;mail: </i><a href="mailto:mpina@tlaloc.imta.mx">mpina@tlaloc.imta.mx</a></font></p>     <p align="justify"><font face="verdana" size="2"><i><sup>2</sup> Universidad Aut&oacute;noma del Estado de Hidalgo (UAEH), Centro de Investigaciones Qu&iacute;micas, Pachuca de Soto, Hidalgo, M&eacute;xico. </i></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><i><sup>3</sup> Estudiante de postgrado de la Facultad de Ingenier&iacute;a, Universidad Nacional Aut&oacute;noma de M&eacute;xico, UNAM, M&eacute;xico.</i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">Recibido 30 de Agosto 2010.    <br> Aceptado 13 de Abril 2011.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     <p align="justify"><font face="verdana" size="2">En este documento se presenta una revisi&oacute;n bibliogr&aacute;fica sobre los fundamentos te&oacute;ricos m&aacute;s importantes de la electrocoagulaci&oacute;n, se anali<i>z</i>an algunos dise&ntilde;os y se muestran los resultados m&aacute;s relevantes al aplicarla al tratamiento de agua para la remoci&oacute;n de diversos contaminantes de origen org&aacute;nico e inorg&aacute;nico. Se enumeran algunas de sus ventajas con respecto a la coagulaci&oacute;n qu&iacute;mica, se hace un an&aacute;lisis comparativo de los dise&ntilde;os experimentales utilizados, as&iacute; como de las metodolog&iacute;as aplicadas, a fin de poder identificar las principales variables que intervienen en los mecanismos de remoci&oacute;n, tales como: la densidad de corriente; el tipo de material, tama&ntilde;o y distancia en los electrodos; el tipo de conexiones utilizadas; el amperaje y voltaje aplicado; el pH, temperatura y conductividad del agua; el tiempo de residencia y el tipo de flujo utilizado. De la literatura especializada que fue consultada se concluye que los mecanismos que intervienen en la electrocoagulaci&oacute;n no han sido a&uacute;n claramente entendidos y hay pocas consideraciones de los factores que influyen en la efectiva remoci&oacute;n de especies i&oacute;nicas, especialmente iones met&aacute;licos en el agua.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave: </b>electrocoagulaci&oacute;n, electrodos, tratamiento de agua, dise&ntilde;o, iones met&aacute;licos.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">This document presents a bibliogr aphical review o f the most important theoretical principles on electrocoagulation; it also analyzes some designs and shows the most relevant results of electrocoagulation, as applied to the treatment of water for the purpose of eliminating several organic and inorganic pollutants. Some advantages of chemical coagulation are listed. Additionally, a comparative analysis of the experimental designs used and of the applied methodologies is made, so as to be able to identify the main variables that operate in removal mechanisms, such as current density, type of material used on the electrodes and their size, distance between electrodes, type of connections used, applied amperage and voltage, pH, temperature and water conductivity, as well as residence time and type of flow used. The specialized literature that was consulted shows that the mechanisms of electrocoagulation have not yet be en clearly understood and thereis little consideration of the factors that influence the effective removal of ionic species, especially metallic ions in water.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Keywords: </b>electrocoagulation, electrodes, water treatment, design, metallic ions.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>1    Introducci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">La electrocoagulaci&oacute;n (EC) es una tecnolog&iacute;a de tratamiento que ha empezado a tomar auge en las &uacute;ltimas d&eacute;cadas, aunque su desarrollo se llev&oacute; a cabo a principios del siglo pasado y fue patentada en los Estados Unidos en 1909. En su forma m&aacute;s sencilla un reactor de electrocoagulaci&oacute;n es una celda electrol&iacute;tica constituida por un &aacute;nodo y un c&aacute;todo. Cuando los electrodos se conectan a una fuente de poder externa, el material del &aacute;nodo ser&aacute; electroqu&iacute;micamente corro&iacute;do por oxidaci&oacute;n y el c&aacute;todo estar&aacute; sujeto a reducci&oacute;n. Sin embargo, se han probado arreglos m&aacute;s eficientes como por ejemplo un par de &aacute;nodos y un par de c&aacute;todos conectados en serie o en paralelo lo que disminuye la pasivaci&oacute;n de los electrodos. Mameriy <i>col. </i>(2001).</font></p>     <p align="justify"><font face="verdana" size="2">Los iones liberados durante la electrocoagulaci&oacute;n forman largas cadenas de polihidr&oacute;xidos, los cuales son diferentes a los formados en la coagulaci&oacute;n convencional cuando se a&ntilde;aden sales qu&iacute;micas, debido a que tienen diferente estructura hidratada. Esta situaci&oacute;n permite retirar, retener y desecar con mayor facilidad los lodos residuales. Los flocs formados de esta forma son menos hidratados, conteniendo menos agua ligada y por lo tanto se compactan m&aacute;s f&aacute;cilmente, Mart&iacute;n <i>y col. </i>(2008).</font></p>     <p align="justify"><font face="verdana" size="2">Durante la formaci&oacute;n de los hidr&oacute;xidos met&aacute;licos, la generaci&oacute;n de los iones est&aacute; acompa&ntilde;ada de la concentraci&oacute;n electrofor&eacute;tica de part&iacute;culas alrededor del electrodo, las cuales neutralizan su carga coagulando. La corriente aplicada obliga a los iones OH&#150; a migrar hacia el &aacute;nodo, por lo que el pH en la capa l&iacute;mite es m&aacute;s alto que en el resto de la soluci&oacute;n, lo que favorece la formaci&oacute;n de hidr&oacute;xidos del metal del electrodo, Mart&iacute;n <i>y col. </i>(2008).</font></p>     <p align="justify"><font face="verdana" size="2">El hidr&oacute;xido formado remueve los contaminantes presentes en el agua por complejaci&oacute;n o atracci&oacute;n electrost&aacute;tica. Adicionalmente, en la proximidad de los electrodos el aumento de la concentraci&oacute;n de los hidr&oacute;xidos con carga positiva atrae aniones como los bicarbonatos y los sulfates que propician la precipitaci&oacute;n del calcio y el magnesio, originando as&iacute; un ablandamiento parcial del agua. Los mecanismos de remoci&oacute;n en electrocoagulaci&oacute;n incluyen oxidaci&oacute;n, reducci&oacute;n, coagulaci&oacute;n, absorci&oacute;n, adsorci&oacute;n, precipitaci&oacute;n y flotaci&oacute;n, Parga <i>y col. </i>(2005).</font></p>     <p align="justify"><font face="verdana" size="2">Los iones Al<sup>3+</sup> &oacute; Fe<sup>2+</sup> son coagulantes muy eficientes para la floculaci&oacute;n de part&iacute;culas, por lo que en EC son frecuentemente utilizados electrodos de hierro o de aluminio.    Los iones de aluminio hidrolizado pueden formar largas cadenas de Al&#150;O&#150;Al&#150;OH las cuales pueden adsorber qu&iacute;micamente una gran cantidad de contaminantes, Shen <i>y col. </i>(2003). El aluminio es normalmente usado para el tratamiento de agua potable y el hierro para el tratamiento de aguas residuales. En el caso del hierro, el Fe(OH)3 forma un coloide caf&eacute; rojizo y dependiendo del pH y de la disponibilidad de iones ferrosos, puede reaccionar con el ox&iacute;geno disuelto para dar Fe<sub>3</sub>O<sub>4</sub>, Yousuf <i>y col. </i>(2001).</font></p>     <p align="justify"><font face="verdana" size="2">Las reacciones qu&iacute;micas que se llevan a cabo en el &aacute;nodo son las siguientes: Chen (2004).</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Para &aacute;nodo de aluminio:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s1.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">En condiciones alcalinas:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s2.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">En condiciones acidas:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s3.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">Para &aacute;nodo de hierro:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s4.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">En condiciones alcalinas:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s5.jpg"></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En condiciones acidas:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s6.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">La electr&oacute;lisis del agua produce ox&iacute;geno e hidr&oacute;geno de la siguiente forma: </font></p>     <p align="justify"><font face="verdana" size="2">En el &aacute;nodo:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s7.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">En el c&aacute;todo es:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s8.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">Entre las principales ventajas de la EC sobre el m&eacute;todo de coagulaci&oacute;n qu&iacute;mica se reportan las siguientes:</font></p>     <blockquote>       <p align="justify"><font face="verdana" size="2">1. La EC requiere equipos relativamente simples, es f&aacute;cil de utilizar y su operaci&oacute;n es flexible, Chen <i>y col. </i>(2002).</font></p>       ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">2. Durante el tratamiento el l&iacute;quido no es enriquecido con aniones y el contenido de sales no se incrementa, como en el caso del tratamiento qu&iacute;mico convencional, Phutdhawong <i>y col. </i>(2000).</font></p>       <p align="justify"><font face="verdana" size="2">3. Se produce hasta un 50% menos de lodos, as&iacute; como un agua con menor concentraci&oacute;n de s&oacute;lidos disueltos (turbiedad), haciendo m&aacute;s factible su reutilizaci&oacute;n, Ogutveren <i>y col. </i>(1997), Tsouris <i>y col. </i>(2001).</font></p>       <p align="justify"><font face="verdana" size="2">4. Los flocs formados por EC son similares a los flocs producidos por coagulaci&oacute;n qu&iacute;mica, excepto que los primeros tienden a ser mucho m&aacute;s largos, contienen menos agua superficial, son &aacute;cido&#150;resistentes y son m&aacute;s estables, por ello pueden ser separados m&aacute;s r&aacute;pido por filtraci&oacute;n.</font></p>       <p align="justify"><font face="verdana" size="2">5. La EC tiene la ventaja de remover las part&iacute;culas coloidales m&aacute;s peque&ntilde;as, debido a que el campo el&eacute;ctrico aplicado incrementa su movimiento facilitando la coagulaci&oacute;n, Yousuf <i>y col. </i>(2001).</font></p>       <p align="justify"><font face="verdana" size="2">6. El proceso de EC evita el uso de agentes qu&iacute;micos, eliminando as&iacute; el problema de neutralizar el exceso de qu&iacute;micos y por lo tanto la posibilidad de una contaminaci&oacute;n secundaria provocada por los mismos, cuando la coagulaci&oacute;n qu&iacute;mica es utilizada, Yousuf <i>y col. </i>(2001).</font></p>       <p align="justify"><font face="verdana" size="2">7. Las burbujas de gas producidas durante la electr&oacute;lisis pueden transportar los contaminantes a la superficie de la soluci&oacute;n, donde &eacute;stos pueden ser m&aacute;s f&aacute;cilmente concentrados, colectados y removidos.</font></p>       <p align="justify"><font face="verdana" size="2">8. Los procesos electrol&iacute;ticos en la celda de EC son controlados el&eacute;ctricamente sin dispositivos mec&aacute;nicos lo que requiere menos mantenimiento.</font></p>       <p align="justify"><font face="verdana" size="2">9. Los componentes del sistema pueden ser fabricados localmente.</font></p>       <p align="justify"><font face="verdana" size="2">10. Las unidades son m&aacute;s compactas.</font></p>       <p align="justify"><font face="verdana" size="2">11. La remoci&oacute;n de ars&eacute;nico trivalente mediante EC es mayor que en la coagulaci&oacute;n qu&iacute;mica empleando cloruro f&eacute;rrico, Ratnay <i>col. </i>(2004).</font></p> </blockquote>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Con el incremento de los par&aacute;metros reguladores de las normas de agua potable y las regulaciones ambientales para las descargas de aguas residuales, las tecnolog&iacute;as electroqu&iacute;micas han tomado nuevamente importancia en todo el mundo durante las dos &uacute;ltimas d&eacute;cadas. Existen diversas industrias que aplican procesos electroqu&iacute;micos para la recuperaci&oacute;n de metales, potabilizaci&oacute;n de agua, tratamiento de descargas de agua residuales procedentes de tener&iacute;as, industrias de electroplatinados, industrias textil, entre otras, Chen (2004).</font></p>     <p align="justify"><font face="verdana" size="2">Aun cuando se ha aplicado exitosamente la EC en el tratamiento de distintos tipos de aguas de desecho ya sea dom&eacute;sticas Chen <i>y col. </i>(2002), industriales Phutdhawong <i>y col. </i>(2000); Shen <i>y col. </i>(2003); Carmona <i>y col. </i>(2006), con alto contenido org&aacute;nico Chen <i>y col. </i>(2000), con presencia de colorantes Xiong <i>y col. </i>(2001) o simplemente para agua potable Mameri <i>y col. </i>(2001); Jiang <i>y col. </i>(2002) esta tecnolog&iacute;a no ha sido aceptada como un sistema convencional de tratamiento Holt <i>y col. </i>(2004) debido a sus elevados costos.</font></p>     <p align="justify"><font face="verdana" size="2">Lo que tambi&eacute;n ha limitado su implementation a gran escala es la falta de un procedimiento sistem&aacute;tico en el dise&ntilde;o y en la operaci&oacute;n del sistema, que reduzca particularmente el problema de la pasivaci&oacute;n de los electrodos y el costo de operaci&oacute;n Holt <i>y col. </i>(2004). El dise&ntilde;o de reactores a escala industrial se basa en criterios emp&iacute;ricos debido a la falta de modelos disponibles que incluyan los principales factores que permitan su optimizaci&oacute;n Chen <i>y col. </i>(2002). Dichos modelos deber&aacute;n considerar factores que influyen en las etapas fisicoqu&iacute;mica, electroqu&iacute;mica e hidr&aacute;ulica del proceso, as&iacute; como sus interacciones.</font></p>     <p align="justify"><font face="verdana" size="2">La mayor&iacute;a de los estudios han estado encaminados a la determinaci&oacute;n de la potencia el&eacute;ctrica requerida para producir una cantidad controlada de coagulante y obtener las caracter&iacute;sticas adecuadas de operaci&oacute;n como son: las propiedades de transporte, tiempo de residencia, voltaje, potencial Z, pH, constituyentes qu&iacute;micos del agua y caracter&iacute;sticas de los electrodos que optimicen el proceso para una condici&oacute;n espec&iacute;fica de operaci&oacute;n. Sin embargo, los mecanismos de la electrocoagulaci&oacute;n no han sido a&uacute;n claramente entendidos y en la mayor&iacute;a de los trabajos existentes s&oacute;lo se establecen las eficiencias para las condiciones de prueba y no se analizan los factores que influyen en la efectiva remoci&oacute;n de especies i&oacute;nicas, especialmente iones met&aacute;licos de agua.</font></p>     <p align="justify"><font face="verdana" size="2">El presente trabajo muestra una revisi&oacute;n bibliogr&aacute;fica de 46 estudios relacionados con la electrocoagulaci&oacute;n en los &uacute;ltimos 23 a&ntilde;os (<a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">Tabla 1</a>), enfatizando los resultados que muestran el an&aacute;lisis de las principales variables de operaci&oacute;n, como son: la densidad de corriente; el tama&ntilde;o, material y distancia de electrodos; las conexiones utilizadas; el amperaje y voltaje aplicado; el pH, temperatura y conductividad del agua; el tiempo de residencia, tipo de flujo utilizado y costos de operaci&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>2 Aplicaciones    de    la    electrocoagulaci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">El an&aacute;lisis de la informaci&oacute;n existente muestra que una gran variedad de part&iacute;culas disueltas y suspendidas pueden ser removidas de manera efectiva de soluciones acuosas por electr&oacute;lisis, Phutdhawong <i>y col. </i>(2000). Entre algunas aplicaciones de la EC se encuentran: la clarificaci&oacute;n de aguas residuales y con fines de potabilizaci&oacute;n, Chen <i>y col. </i>(2002); la remoci&oacute;n de cromato, cianuro y ars&eacute;nico de efluentes industriales, Balasubramanian <i>y col. </i>(2001), de fluoruro en agua para consumo humano, Mameri <i>y col. </i>(2001), de materia org&aacute;nica soluble, Tsai <i>y col. </i>(1996), de aceites en emulsi&oacute;n, Hosny (1996), Biswas <i>y col. </i>(1991); la recuperaci&oacute;n de compuestos fen&oacute;licos, Phutdhawong <i>y col. </i>(2000) y t&aacute;nicos, Chowwanapoonpohn <i>y col. </i>(2003), entre otros. El agua tratada por EC se convierte en agua clara, limpia, sin olor y lista para reutilizarse.</font></p>     <p align="justify"><font face="verdana" size="2">Otros autores, Mohammad <i>y col. </i>(2009) han realizado una amplia revisi&oacute;n bibliogr&aacute;fica para conocer los tipos de contaminantes removidos y su eficiencia mediante procesos de electrocoagulaci&oacute;n y electrocoagulaci&oacute;n&#150;flotaci&oacute;n. En su art&iacute;culo consideran el agua contaminada con aceite, agua de desecho de la industria textil (colorantes), compuestos fen&oacute;licos, aguas residuales municipales e industriales, metales pesados en aguas residuales, turbiedad y metales pesados en agua potable, nitratos, nitritos, amoniaco y fluoruros. En el caso de la industria textil, mencionan que la eficiencia de la EC depende del pH, de la concentraci&oacute;n del colorante, la densidad de corriente aplicada y el tiempo de residencia.</font></p>     <p align="justify"><font face="verdana" size="2">Tambi&eacute;n reportan que los procesos de EC son m&aacute;s eficientes que la coagulaci&oacute;n qu&iacute;mica en el tratamiento del agua potable. Para el caso de los nitratos, nitritos y amoniaco, es factible la EC, pero se requiere de m&aacute;s investigaci&oacute;n ya que no se han establecido los mecanismos de remoci&oacute;n. De igual manera, la defluoraci&oacute;n del agua es efectiva empleando la EC, pero no hay suficiente informaci&oacute;n relacionada con los complejos formados de Al&#150;F.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>3 Configuraciones hidr&aacute;ulicas y el&eacute;ctricas</b></font></p>     <p align="justify"><font face="verdana" size="2">El arreglo de los electrodos puede ser de forma mono&#150;polar o bi&#150;polar y los materiales pueden ser aluminio o hierro, en forma plana o paquetes de l&aacute;minas (ver <a href="#f1">Fig. 1a</a>).</font></p>     <p align="center"><font face="verdana" size="2"><a name="f1"></a></font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10f1.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">Dependiendo de la orientaci&oacute;n de los electrodos (placas), el flujo dentro de la celda de electrocoagulaci&oacute;n puede ser vertical u horizontal (<a href="#f1">Fig. 1b</a>). El agua fluye a trav&eacute;s de los espacios entre las placas, que pueden ser canales m&uacute;ltiples o un solo canal como se aprecia en la <a href="#f2">Fig. 2</a>. Los canales m&uacute;ltiples es un arreglo simple, pero normalmente la velocidad de flujo en cada canal es baja. Cuando no es posible reducir la pasivaci&oacute;n en la superficie de los electrodos, se recomienda incrementar la velocidad del flujo utilizando un sistema con un solo canal, Chen (2004).</font></p>     <p align="center"><font face="verdana" size="2"><a name="f2"></a></font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10f2.jpg"></font></p>     <p align="justify"><font face="verdana" size="2">Tambi&eacute;n se han utilizado electrodos bipolares con celdas en paralelo.    En este caso el electrodo "sacrificable" se localiza entre dos electrodos paralelos sin ninguna conexi&oacute;n el&eacute;ctrica. S&oacute;lo los electrodos monopolares se conectan a la fuente externa de poder. Este tipo de arreglos resuelve en parte la disminuci&oacute;n de la eficiencia de la electrocoagulaci&oacute;n por formaci&oacute;n de una capa de &oacute;xido sobre los electrodos.</font></p>     <p align="justify"><font face="verdana" size="2">Otra forma de aumentar la eficiencia de esta t&eacute;cnica es utilizar corriente alterna que retarda los mecanismos normales de ataque de los electrodos, sin embargo, los campos de corriente alterna pueden desestabilizar el sistema. Tambi&eacute;n se ha aplicado esta tecnolog&iacute;a en unidades de lecho fluidizado equipados con metales no consumibles y con part&iacute;culas de aluminio sometidas a flujo turbulento. La agitaci&oacute;n es mantenida con aire comprimido, Xiong y col. (2001).</font></p>     <p align="justify"><font face="verdana" size="2">Es importante tambi&eacute;n considerar los tiempos de residencia en el reactor, ya que de este depende el tama&ntilde;o del mismo. Algunos autores como Deshpande (2010) emplean mayores tiempos de residencia para incrementar la dosis del coagulante, lo que mejora la eficiencia de remoci&oacute;n, pero aumenta el tama&ntilde;o de las unidades y por lo tanto los costos de inversi&oacute;n.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">En este mismo sentido se debe considerar el tipo de flujo, es decir, si se trata de un sistema en lotes (batch) o en continuo, la configuraci&oacute;n de los electrodos y los tipos de conexi&oacute;n (bipolar y monopolar) que repercuten en la eficiencia y en el costo. Sin embargo, la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a> muestra que la informaci&oacute;n publicada hasta el momento est&aacute; enfocada principalmente a las eficiencias de remoci&oacute;n de los contaminantes, sin mostrar detalles de los dise&ntilde;os de los prototipos utilizados y sin profundizar en la influencia de las variables involucradas en los procesos.</font></p>     <p align="justify"><font face="verdana" size="2">Otros autores, Mart&iacute;n y col. (2008) evaluaron la incidencia del gradiente de velocidad en el mezclado (coagulaci&oacute;n) con la eficiencia en la remoci&oacute;n de ars&eacute;nico (As) en agua para consumo humano utilizando un reactor de EC a flujo pist&oacute;n con electrodos de hierro (Fe). Encontraron que existe una clara tendencia a que la eficiencia del Fe producido y removido aumente al aumentar el gradiente de velocidades en el mezclado (<i>G</i>) y el producto del <i>G</i> con el tiempo <i>t</i> (Gt).</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>4 Material de los electrodos</b></font></p>     <p align="justify"><font face="verdana" size="2">En el caso de la EC con &aacute;nodos de sacrificio, la selecci&oacute;n del material del electrodo va a depender de la naturaleza y afinidad que tenga el contaminante que se pretende remover con el coagulante producido, es decir, si se quiere remover material suspendido, el coagulante debe propiciar una desestabilizaci&oacute;n de los coloides para que &eacute;stos se aglutinen y posteriormente sean separados por precipitaci&oacute;n. En el caso de elementos disueltos se busca que el coagulante los adsorba o los retenga mediante alg&uacute;n mecanismo fisicoqu&iacute;mico. Cuando se trata de electrodos inertes como el acero inoxidable, el titanio, platino, n&iacute;quel, grafito, etc., el mecanismo de remoci&oacute;n es debido a que se presenta una reducci&oacute;n electroqu&iacute;mica del agua en el c&aacute;todo increment&aacute;ndose el pH propiciando la formaci&oacute;n de sales b&aacute;sicas poco solubles e hidr&oacute;xidos de metales polivalentes que precipitan, Gorodovykh <i>y col. </i>(1987).</font></p>     <p align="justify"><font face="verdana" size="2">La utilizaci&oacute;n de electrodos de aluminio tiende a ser minimizada con respecto a los de hierro, debido a los problemas de disposici&oacute;n de los lodos conteniendo ese metal y a la alta pasivaci&oacute;n de los electrodos Morante <i>y col. </i>(2002), Wan <i>y col. </i>(1991), Sin embargo, Mohammad <i>y col. </i>(2009) en su revisi&oacute;n concluyen que de acuerdo a los resultados experimentales de diversos autores, los electrodos de Al son mas eficientes que los de Fe para la remoci&oacute;n de aceites. En el caso de metales pesados se puede remover de manera muy eficiente el ars&eacute;nico (As) y el cadmio de aguas residuales. Para As la remoci&oacute;n es muy eficiente utilizando electrodos de Fe considerando mecanismos de adsorci&oacute;n de los hidr&oacute;xidos de Fe con las especies de As.</font></p>     <p align="justify"><font face="verdana" size="2">Electrodos inertes como el titanio y el paso de una corriente alterna, tambi&eacute;n remueve iones met&aacute;licos y promueve la coagulaci&oacute;n de s&oacute;lidos suspendidos. En este caso el movimiento electrofor&eacute;tico concentra las part&iacute;culas de carga negativa en el &aacute;nodo y por neutralizaci&oacute;n de cargas se facilita la coagulaci&oacute;n, Mart&iacute;n <i>y col. </i>(2008).</font></p>     <p align="justify"><font face="verdana" size="2">En Mohammad <i>y col. </i>(2009) se compar&oacute; la eficiencia de remoci&oacute;n de la Demanda Qu&iacute;mica de Ox&iacute;geno (DQO), turbiedad, fenoles, hidrocarburos y grasas utilizando electrodos de aluminio (Al) e hierro (Fe) a diferentes tiempos de electr&oacute;lisis (2.5, 5, 10, 15 y 20 minutos), y se encontr&oacute; que en general se remueven m&aacute;s fenoles e hidrocarburos con electrodos de Al. Con electrodos de Fe se remueve m&aacute;s turbiedad y grasas y no hay una diferencia importante para la remoci&oacute;n de la DQO utilizando electrodos de Fe y Al. Del an&aacute;lisis se concluy&oacute; que la eficiencia y capacidad de los procesos de electrocoagulaci&oacute;n dependen de la naturaleza del agua residual y de las concentraciones de los contaminantes.</font></p>     <p align="justify"><font face="verdana" size="2">En la <a href="/img/revistas/rmiq/v10n2/a10t2.jpg" target="_blank">Tabla 2</a> se muestra el porcentaje de estudios analizados,  con relaci&oacute;n al tipo de contaminante, material de los electrodos y tipo de flujo utilizado. Se observa una mayor frecuencia de experimentaciones hacia los procesos en lotes (batch) para tratar contaminantes inorg&aacute;nicos utilizando electrodos de aluminio.</font></p>     <p align="justify"><font face="verdana" size="2">Para poder observar un comportamiento general de la frecuencia en relaci&oacute;n a las condiciones experimentales realizadas (lotes y continuo) y al tipo de material empleado en los electrodos se elabor&oacute; un gr&aacute;fico (<a href="/img/revistas/rmiq/v10n2/a10f3.jpg" target="_blank">Fig. 3</a>) donde se resume la revisi&oacute;n bibliogr&aacute;fica de la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a> y la hecha por Mohammad y col. (2009). En algunos casos se utilizaron c&aacute;todos de acero inoxidable u otro elemento resistente a la corrosi&oacute;n como el grafito, Pt y Ti. Se omitieron los datos experimentales de Russell, (1988) y Baklan y col. (1996) de la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a> debido a que no reportaron el tipo de flujo utilizado.</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">El color, en la mayor&iacute;a de los casos mostrados en la <a href="/img/revistas/rmiq/v10n2/a10f3.jpg" target="_blank">Fig. 3</a>, es proveniente de pigmentos de la industria textil; en los metales pesados est&aacute;n incluidos el Cr<sup>+6</sup>, Cd<sup>+2</sup>, Se, St, Ni, Cr, Zn, Pb, CN, As y un caso para el s&iacute;lice que utilizaron electrodos de hierro y aluminio (<a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a>); en las aguas residuales urbanas e industriales se reportaron las remociones de detergentes, pesticidas, humus, carb&oacute;n org&aacute;nico total, DQO, DBO y compuestos fen&oacute;licos. El aluminio como &aacute;nodo de sacrificio sigue siendo el mayormente utilizado para el tratamiento de aguas residuales y para metales pesados se utilizan m&aacute;s los &aacute;nodos de hierro. Tambi&eacute;n se observa en la Fig. (<a href="/img/revistas/rmiq/v10n2/a10f3.jpg" target="_blank">3</a>) una mayor tendencia hacia las pruebas en lotes <i>(batch) </i>debido al mayor control y simplicidad de operaci&oacute;n que &eacute;stos presentan.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>5 Condiciones fisicoqu&iacute;micas del agua</b></font></p>     <p align="justify"><font face="verdana" size="2">Las condiciones de operaci&oacute;n de la electrocoagulaci&oacute;n dependen de la qu&iacute;mica del medio acuoso, especialmente de la conductividad y el pH, pero tambi&eacute;n influyen el tama&ntilde;o de part&iacute;culas, el tipo de electrodos, el tiempo de retenci&oacute;n, el espaciamiento entre electrodos y la concentraci&oacute;n de los contaminantes, Mart&iacute;n <i>y col. </i>(2008).</font></p>     <p align="justify"><font face="verdana" size="2">Tambi&eacute;n hay que tomar en cuenta que las caracter&iacute;sticas fisicoqu&iacute;micas del agua pueden modificar las propiedades de los contaminantes, afectando as&iacute; su remoci&oacute;n, tal es el caso del pH y la temperatura del agua, los cuales deben ser controladas para minimizar los efectos adversos a los mecanismos de remoci&oacute;n. Los efectos del pH en el agua se ven reflejados en la eficiencia de la corriente y en la solubilidad de los hidr&oacute;xidos met&aacute;licos, se ha encontrado una mejor eficiencia de remoci&oacute;n a pH cercanos a 7. Por otro lado, a pesar de que no se ha investigado a profundidad el efecto de la temperatura en la EC, se ha encontrado que la eficiencia de la corriente aplicada para el aluminio se incrementa hasta los 60&deg; C, efecto que se atribuye a la destrucci&oacute;n de la pel&iacute;cula de &oacute;xidos de aluminio que se forma en la superficie de los electrodos. Chen (2004), Tsouris (2001).</font></p>     <p align="justify"><font face="verdana" size="2">Por otra parte, no se observa en los estudios analizados la utilizaci&oacute;n de los criterios que establece la literatura sobre la coagulaci&oacute;n qu&iacute;mica, como son: gradientes y tiempos de mezclado, floculaci&oacute;n, etc., Arboleda (2000) y AWWA (1999), los cuales deben aplicarse y cumplirse en el proceso de la electrocoagulaci&oacute;n y deben utilizarse para el dise&ntilde;o de reactores electroqu&iacute;micos.</font></p>     <p align="justify"><font face="verdana" size="2">Ejemplos de esto se pueden ver en los trabajos publicados por Gorodo&#150;vykh (1987), Renk (1988), Poon (1997), Kovatcheva (1999), Ciorba (2000), Balasubramaniam (2001), Chartrand (2003) y Azarian (2007) quienes no presentan informaci&oacute;n b&aacute;sica como la ca&iacute;da de potencial en el reactor ni la conductividad del agua en la que se llevaron a cabo las pruebas.</font></p>     <p align="justify"><font face="verdana" size="2">De las 38 publicaciones presentadas en la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">Tabla 1</a>, solo 12 reportan la conductividad con la que realizaron sus experimentos, Morante (2002) muestra un caso extremo de conductividad elevada (1.2 E6 juS/cm) para la remoci&oacute;n de grasas, aceites y DQO. Una ventaja que se observa en el tratamiento de aguas residuales, en comparaci&oacute;n con fuentes de agua natural, es la mayor conductividad de la primera que permite disminuir los costos del tratamiento por un menor consumo de energ&iacute;a., Jiang (2002), Paul A. (1996) y Zaied (2008).</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>6 Caracter&iacute;sticas electroqu&iacute;micas</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">La selecci&oacute;n de los par&aacute;metros analizados en la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a> se realiz&oacute; con base en la relaci&oacute;n que guardan entre ellos en un proceso electroqu&iacute;mico. En el caso del voltaje o diferencia de potencial, que es definida como la resistencia en ohmios (&#937;) al paso de una corriente el&eacute;ctrica en amperios (A) aplicada en un circuito el&eacute;ctrico (Ley de Ohm), se requiere considerar principalmente la conductividad el&eacute;ctrica del electrolito y la separaci&oacute;n de los electrodos. Esto finalmente determina el consumo de energ&iacute;a del proceso y por consiguiente el costo del tratamiento.</font></p>     <p align="justify"><font face="verdana" size="2">La densidad de corriente, donde se relaciona la cantidad de corriente el&eacute;ctrica aplicada por unidad de &aacute;rea de electrodos (A/&aacute;rea), se eval&uacute;a con respecto a la pasivaci&oacute;n de los electrodos, es decir, a densidades de corriente altas hay una mayor probabilidad de que se presente la pasivaci&oacute;n del material, pero densidades de corriente bajas implican un mayor volumen de reactor y por lo tanto mayores tiempos de residencia. Deshpande (2010), Ghosh (2008).</font></p>     <p align="justify"><font face="verdana" size="2">Un valor muy elevado de densidad de corriente puede disminuir significativamente la eficiencia de la corriente debido a la producci&oacute;n de ox&iacute;geno y adem&aacute;s influye en la pasivaci&oacute;n de los electrodos, algunos autores recomiendan valores entre 20&#150;25 A/m<sup>2</sup>, Chen (2004).</font></p>     <p align="justify"><font face="verdana" size="2">Siendo la densidad de corriente uno de los par&aacute;metros de mayor relevancia en la EC, autores como Renk (1988), Biswas (1991), Matteson (1995), Tsai (1996), Paul (1996), Bertazzoli (1997), &Oacute;g&uuml;tveren (1997), Xiong (2001), GH Azarian (2007) y Amir (2007) no lo reportan en sus publicaciones.</font></p>     <p align="justify"><font face="verdana" size="2">En la <a href="/img/revistas/rmiq/v10n2/html/a10t1.htm" target="_blank">tabla 1</a> se aprecian valores de densidades de corriente que van de 0.00023, Morante (2002), a 0.073 A/cm<sup>2</sup>, Chartrand (2003), aunque en la mayor&iacute;a de los casos se procura operar a densidades de corrientes bajas para evitar la pasivaci&oacute;n de los electrodos.</font></p>     <p align="justify"><font face="verdana" size="2">Hay autores que no mencionan la distancia ni el tama&ntilde;o de los electrodos y/o su &aacute;rea activa, tal es el caso de Gorodo&#150;vykh (1987), Renk (1988), Balasubramaniam (2001) y Chartrand (2003). Estos par&aacute;metros de operaci&oacute;n son importantes para establecer la resistencia del sistema al paso de la corriente, y por lo tanto los costos por consumo de energ&iacute;a.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>7 Influencia de iones presentes en el sistema</b></font></p>     <p align="justify"><font face="verdana" size="2">Hay estudios que muestran Chen (2004), que la presencia de NaCl reduce el efecto adverso de la presencia de otros iones como <img src="/img/revistas/rmiq/v10n2/a10s10.jpg">, <img src="/img/revistas/rmiq/v10n2/a10s11.jpg">, que en presencia de Ca<sup>2+</sup> &oacute; Mg<sup>2+</sup> forman una pel&iacute;cula aislante en la superficie de los electrodos que los pasiva. La presencia de sal tambi&eacute;n ayuda a disminuir el consumo de energ&iacute;a al aumentar la conductividad, adem&aacute;s, cuando hay cloruros en el agua se pueden presentar las reacciones siguientes en presencia de una corriente el&eacute;ctrica, lo que favorece la desinfecci&oacute;n:</font></p>     <p align="center"><font face="verdana" size="2"><img src="/img/revistas/rmiq/v10n2/a10s9.jpg"></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>8 Costos de operaci&oacute;n</b></font></p>     <p align="justify"><font face="verdana" size="2">En cuanto a los costos de operaci&oacute;n, Jaing <i>y col. </i>(2002) compararon la electrocoagulaci&oacute;n contra la coagulaci&oacute;n qu&iacute;mica con flotaci&oacute;n por aire disuelto, y reportaron que el costo se increment&oacute; conforme la densidad de corriente aumentaba, y que el costo por el consumo de los electrodos de aluminio representaba de un 70 a 90% del costo total.</font></p>     <p align="justify"><font face="verdana" size="2">Otros autores, Nielson <i>y col. </i>(2005), mencionan que los costos por concepto de material del electrodo, en el caso de utilizar aluminio, es de CAN$7/kg, lo que para dosificaciones de 81 mgAl/L genera un costo del agua tratada (s&oacute;lo por material de electrodos) de CAN$0.57/m<sup>3</sup>.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Conclusiones</b></font></p>     <p align="justify"><font face="verdana" size="2">En general, en la mayor&iacute;a de los art&iacute;culos revisados solo se muestran las eficiencias de remoci&oacute;n sobre alg&uacute;n tipo de contaminante, bajo las condiciones espec&iacute;ficas en que se llevaron a cabo las pruebas, ya sea en lotes (<i>batch</i>) o en continuo y no se describen los detalles de los modelos experimentales empleados ni de todas las variables experimentales que son muy &uacute;tiles para poder tratar de interpretar los posibles mecanismos que se llevan a cabo en el sistema sobre alg&uacute;n contaminante en espec&iacute;fico. Tampoco se observa el uso de los criterios de la coagulaci&oacute;n qu&iacute;mica aplicados a la electrocoagulaci&oacute;n y que son fundamentales para realizar dise&ntilde;os apropiados al tipo de contaminante que se pretende remover.</font></p>     <p align="justify"><font face="verdana" size="2">Se puede decir que la electrocoagulaci&oacute;n funciona adecuadamente como una tecnolog&iacute;a alterna en el tratamiento de aguas residuales y agua potable, ya que los resultados mostrados en los documentos analizados, cumplen con las expectativas del investigador sobre los requerimientos espec&iacute;ficos de cada caso, pero es necesario seguir investigando para poder establecer, en cada caso, los mecanismos mediante los cuales interact&uacute;an los contaminantes y el coagulante generado, as&iacute; como definir el papel que juegan en tales mecanismos la presencia de otros elementos disueltos en el agua.</font></p>     <p align="justify"><font face="verdana" size="2">Por otro lado, se recomienda que en futuras investigaciones se definan, adem&aacute;s de los contaminantes que se pretenden remover, de manera clara y completa el control de variables de operaci&oacute;n de mayor relevancia en los procesos electroqu&iacute;micos, como son el voltaje, la densidad de corriente, el material de los electrodos, la distancia entre los electrodos, el tipo de conexi&oacute;n entre &eacute;stos, su tama&ntilde;o y &aacute;rea activa, as&iacute; tambi&eacute;n se deben establecer las caracter&iacute;sticas fisicoqu&iacute;micas del electrolito como son el pH, la conductividad y la temperatura. Tambi&eacute;n, en ese mismo sentido se deben definir claramente las condiciones de flujo y tiempos de residencia, ya que de &eacute;stos depende su factibilidad de ser aplicados a grandes escalas.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>Referencias</b></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Arboleda Valencia J. (2000). <i>Teor&iacute;a y Pr&aacute;ctica de la purificaci&oacute;n del agua. </i>McGraw&#150;Hill, Tercera edici&oacute;n, Sao Paulo, Brasil.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546334&pid=S1665-2738201100020001000001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">AWWA American Water Works Association. (1999). <i>Water Quality &amp; Treatment. </i>McGraw&#150;Hill., Quinta edici&oacute;n.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546336&pid=S1665-2738201100020001000002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Azarian G.H., Mesdaghinia A.R., Vaezi F., Nabizadeh R., Nematollahi D. (2007). Algae Removal by electro&#150;coagulation process, application for treatment of the effluent from industrial wastewater treatment plant. <i>Iranian Journal of Public Health 36, </i>57&#150;64.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546338&pid=S1665-2738201100020001000003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Balasubramanian N. y Madhavan K. (2001). Arsenic Removal from industrial effluent through electrocoagulation. <i>Chemical Engineering Technology 24, </i>519&#150;521.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546340&pid=S1665-2738201100020001000004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Baklan V. Yu. y Kolesnikova I. P. (1996). Influence of electrode material on the electrocoagulation. <i>Journal of Aerosol Science 27, </i>209&#150;210.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546342&pid=S1665-2738201100020001000005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Bertazzoli R., Widner R. C., Lanza M.R.V., Di Iglia R.A., Sousa F.B.M. (1997). Electrolytic removal of metals using a flow&#150;through cell with a reticulated vitreous carbon cathode. <i>Journal of the Brazilian Society 8</i>, 487&#150;493.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546344&pid=S1665-2738201100020001000006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Biswas N. y Lazarescu G. (1991). Removal of oil from emulsions using electrocoagulation. <i>International Journal of Environmental Studies 38</i>, 65&#150;75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546346&pid=S1665-2738201100020001000007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Burns S. E., Yiacoumi S., Tsouris C. (1997). Microbubble generation for environmental and industrial separations. <i>Separation and Purification Technology 11</i>, 221&#150;232.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546348&pid=S1665-2738201100020001000008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Chartrand M.M.G. y Bunce N.J. (2003). Electrochemical remediation of acid mine drainage. <i>Journal of Applied Electrochemistry 33</i>, 259&#150;264.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546350&pid=S1665-2738201100020001000009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Ciorba G.A., Radovan C., Vlaicu I. y Pitulice L. (2000). Correlation between organic component and electrode material: Consequences on removal of surfactants from wastewater. <i>Electrochimica Acta 46</i>, 297&#150;303.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546352&pid=S1665-2738201100020001000010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Chen X., Chen G. y Yue Po L. (2002). Novel electrode system for electroflotation of wastewater. <i>Environmental Science &amp; Technology 36</i>, 778&#150;783</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546354&pid=S1665-2738201100020001000011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Chen G. (2004). Electrochemical technologies in wastewater treatment. <i>Separation and Purification Technology 38</i>, 11&#150;41.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546355&pid=S1665-2738201100020001000012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Chen, X, Chen, G. y Yue, L.P. (2002). Investigation on the electrolysis voltage of electrocoagulation. <i>Chemical Engineering Science 57</i>, 2449&#150;2455.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546357&pid=S1665-2738201100020001000013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Chowwanapoonpohn S., Chewchanwuttiwong S., Garson M. J. y Buddhasukh, D. (2003). Electrocoagulation and recovery of tannins from tree barks. <i>Journal of Applied Electrochemistry 33</i>, 647&#150;650.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546359&pid=S1665-2738201100020001000014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Den W., Wang C.J. (2008). Removal of silica from brackish water by electrocoagulation pretreatment to prevent fouling of reverse osmosis    membranes.  &nbsp; <i>Separation    and Purification Technology 59</i>, 318&#150;325.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546361&pid=S1665-2738201100020001000015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">Deshpande, A. M., Satyanarayan, S. y Ramakant, S. (2010). <i>Treatment of high&#150;strength pharmaceutical wastewater by electrocoagulation  combined  with  anaerobic process</i>. Water Science and Technology&#150;WST&#150;61.2. IWA Publishing.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546363&pid=S1665-2738201100020001000016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Emamjomeh M.M., Sivakumar M. (2009). Fluoride removal by a continuous flow electrocoagulation    reactor. <i>Journal    of Environmental Management 90</i>, 1204&#150;1212.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546365&pid=S1665-2738201100020001000017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Emamjomeh M.M., Sivakumar M. (2009). Review of pollutants removed by electrocoagulation and electrocoagulation/flotation processes. <i>Journal of Environmental Management 90</i>, 1663&#150;1679.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546367&pid=S1665-2738201100020001000018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Ghosh D., Medhi C.R., Purkait M.K. (2008). Treatment of fluoride containing drinking water by electrocoagulation using monopolar and bipolar electrode connections. <i>Chemosphere 73</i>, 1393&#150;1400.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546369&pid=S1665-2738201100020001000019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Gorodovykh V. E., Kaplin A. A., Svishchenko N. M., Obraztsov S. V. (1987). Purification of water by electrocoagulation with an alternating asymmetrical current for stripping voltammetry. <i>Zhurnal Analiticheskoi Khimii 42</i>, 1024&#150;1026.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546371&pid=S1665-2738201100020001000020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">Hernlem B. J., Tsai L. S. (2000). Chlorine generation and disinfection by electroflotation. <i>Journal of Food Science 65</i>, 834&#150;837.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546373&pid=S1665-2738201100020001000021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Hosny A.Y. (1996). Separating oil from oil&#150;water emulsions by electroflotation technique. <i>Separations Technology 6</i>, 9&#150;17</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546375&pid=S1665-2738201100020001000022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Hossein Mahvi A. y Bazrafshan E. <i>Removal of Cadmium from Industrial Effluents by Electrocoagulation Process Using Aluminum Electrodes</i>. World Applied Sciences Journal (2007).    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546376&pid=S1665-2738201100020001000023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Jiang J. Q., Graham N. J. D., Andr&eacute; C. M., Kelsall G. H., Brandon N. P., Chipps M. J. (2002). Comparative performance of an electro coagulation/flotation system with chemical coagulation/dissolved air flotation: A pilot&#150;scale trial. Electrolytic treatment of turbid water in package plant. <i>Water Science and Technology: Water Supply 2</i>, 289&#150;297.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546378&pid=S1665-2738201100020001000024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Jumpatong K., Buddhasukh D. (2003). Electrocoagulation of some heavy metals. Contributed paper <i>Chiang Mai Journal of Science 30</i> (1), 33&#150;40.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546380&pid=S1665-2738201100020001000025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Kovatcheca Valeria K., Parlapanski Marin D. (1999). Sono&#150;electrocoagulation of iron hydroxides. <i>Colloids and Surfaces A: Physicochemical and Engineering Aspects 149</i>, 603&#150;608.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546382&pid=S1665-2738201100020001000026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Lescuras&#150;Darrou V., Lapicque F., Valentin G. (2001). Electrochemical ferrate generation for waste water treatment using cast irons with high silicon contents.<i> Journal of Applied Electrochemistry 32</i>, 57&#150;63</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546384&pid=S1665-2738201100020001000027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Mameri N., Loucini H., Belhocine D., Grib H., Piron D. L., Yahiat Y. (2001). Defluoridation of sahara water by small plant electro coagulation using bipolar aluminium electrodes. <i>Separation and Purification Technology 24</i>, 113&#150;119.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546385&pid=S1665-2738201100020001000028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Mart&iacute;n D.A., Rivera H.M.L., Pi&ntilde;a S.M., P&eacute;rez C.S. (2008). Incidencia del gradiente de velocidad en la eficiencia de la electrocoagulaci&oacute;n para remover ars&eacute;nico en un reactor a flujo pist&oacute;n. <i>Interciencia, Revista de Ciencia y Tecnolog&iacute;a 33</i>, 503&#150;509.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546387&pid=S1665-2738201100020001000029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Matteson Michael J., Dobson Regina L., Glenn Robert W. Jr., Kukunoor S. Nagesh, Waits William H. III, Clayfield Eric J. (1995). Electrocoagulation and separation of aqueous suspensions of ultra fine particles. <i>Colloids and Surfaces A: Physicochemical and Engineering Aspects 104</i>, 101&#150;109.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546389&pid=S1665-2738201100020001000030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Morante G.G. (2002). Electrocoagulaci&oacute;n de aguas residuales.<i> Revista Colombiana de F&iacute;sica 34</i>, 484&#150;487.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546391&pid=S1665-2738201100020001000031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">Morales Posada N.B., Acosta Ni&ntilde;o G.E. (2010). Sistema de electrocoagulaci&oacute;n como tratamiento de aguas residuales galv&aacute;nicas. <i>Ciencia e Ingenier&iacute;a Neogranadina 20</i>, 33&#150;44.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546393&pid=S1665-2738201100020001000032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">&Ouml;g&uuml;tveren &Uuml;lker B., Koparal S. (1997). Electrocoagulation for oil&#150;water emulsion treatment. <i>Journal of Environmental Science and Health 32</i>, 2507&#150;2520.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546395&pid=S1665-2738201100020001000033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Paul A. B. (1996). Electrolytic treatment of turbid water in package plant. <i>22nd WEDC Conference</i>, New Delhi India, 35&#150;47.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546397&pid=S1665-2738201100020001000034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Parga J.R., Cocke D.L., Valenzuela J.L., Gomes J.A., Kesmez M., Irwin G., Moreno H., Weir M. (2005). Arsenic removal via electrocoagulation from heavy metal contaminated groundwater in La Comarca Lagunera M&eacute;xico. <i>Journal of Hazardous Materials B124</i>, 247&#150;254.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546399&pid=S1665-2738201100020001000035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Phutdhawong W., Chowwanapoonpohn S., Buddhasukh D. (2000). Electrocoagulation and subsequent recovery of phenolic compounds. <i>Analytical Sciences 16</i>, 1083&#150;1084.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546401&pid=S1665-2738201100020001000036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">Poon C. P. C. (1997). Electroflotation for groundwater decontamination. <i>Journal of Hazardous Materials 55</i>, 159&#150;170</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546403&pid=S1665-2738201100020001000037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Pouet M. &#150;F. and Grasmick A. (1995). Urban wastewater treatment by electrocoagulation and flotation. <i>Water Science &amp; Technology 31</i>, 275&#150;283.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546404&pid=S1665-2738201100020001000038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Pouet M&#150;F, Persin F., Rumeau M. (1992). Intensive treatment by electrocoagulation&#150;flotation&#150;tangential flow micro filtration in areas of high seasonal population. <i>Water Science and Technology 25</i>, 247&#150;253</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546406&pid=S1665-2738201100020001000039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Ratna Kumar P., Chaudhari S., Khilar K.C., Mahajan S.P. (2004). Removal of arsenic from water by electrocoagulation. <i>Chemosphere 55</i>, 1245&#150;1252.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546407&pid=S1665-2738201100020001000040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Renk R. (1988).  <i>Treatment of Hazardous Wastewaters by Electrocoagulation</i>. Research Engineer. Western Research Institute.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546409&pid=S1665-2738201100020001000041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Sanfan W. (1991). Studies on economic property of pretreatment process of brackish using electrocoagulation (EC) method. <i>Desalination 82</i>, 365&#150;373.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546411&pid=S1665-2738201100020001000042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">Subramanyan V., Jothinathan L., Jeganathan J., Ganapathy S. (2009). Remediation of phosphate&#150;contaminated water by electrocoagulation with aluminium, aluminium alloy and mild steel anodes. <i>Journal of Hazardous Materials 164</i>, 1480&#150;1486.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546413&pid=S1665-2738201100020001000043&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Tsai C. T., Lin S. T., Shue Y. C., Su P. L. (1996). Electrolysis of soluble organic matter in leachate from landfills. <i>Water Research 31</i>, 3073&#150;3081.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546415&pid=S1665-2738201100020001000044&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Tsouris C., DePaoli D. W., Shor J. T., Hu M.Z. &#150;C., Ying T.&#150;Y. (2001). Electrocoagulation for magnetic seeding of colloidal particles. <i>Colloids and Surfaces. A: Physicochemical and Engineering Aspects 177</i>, 223&#150;233</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546417&pid=S1665-2738201100020001000045&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Xiong Y., Strunk P.J., Xia H., Zhu X., Karlson H.T. (2001). Treatment of dye wastewater containing acid orange II using a cell with three&#150;phase three&#150;dimensional electrode. <i>Water Research 35</i>, 4226&#150;4230</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546418&pid=S1665-2738201100020001000046&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">Yousuf M., Mollah A., Schennach R., Parga J.R., Cocke D.L. (2001). Electrocoagulation (EC)&#150;science and applications. <i>Journal of Hazardous Materials B84</i>, 29&#150;41.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546419&pid=S1665-2738201100020001000047&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">Zaied M., Bellakhal N. (2009).  Electrocoagulation treatment of black liquor from paper industry.<i> Journal of Hazardous Materials 30,</i>995&#150;1000.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8546421&pid=S1665-2738201100020001000048&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </font></p>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arboleda Valencia]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Teoría y Práctica de la purificación del agua]]></source>
<year>2000</year>
<edition>Tercera</edition>
<publisher-loc><![CDATA[Sao Paulo ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="book">
<collab>AWWA</collab>
<source><![CDATA[Water Quality & Treatment]]></source>
<year>1999</year>
<edition>Quinta</edition>
<publisher-name><![CDATA[McGraw-Hill.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Azarian]]></surname>
<given-names><![CDATA[G.H.]]></given-names>
</name>
<name>
<surname><![CDATA[Mesdaghinia]]></surname>
<given-names><![CDATA[A.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Vaezi]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Nabizadeh]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Nematollahi]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Algae Removal by electro-coagulation process, application for treatment of the effluent from industrial wastewater treatment plant]]></article-title>
<source><![CDATA[Iranian Journal of Public Health]]></source>
<year>2007</year>
<volume>36</volume>
<page-range>57-64</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balasubramanian]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Madhavan]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Arsenic Removal from industrial effluent through electrocoagulation]]></article-title>
<source><![CDATA[Chemical Engineering Technology]]></source>
<year>2001</year>
<volume>24</volume>
<page-range>519-521</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baklan]]></surname>
<given-names><![CDATA[V. Yu.]]></given-names>
</name>
<name>
<surname><![CDATA[Kolesnikova]]></surname>
<given-names><![CDATA[I. P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of electrode material on the electrocoagulation]]></article-title>
<source><![CDATA[Journal of Aerosol Science]]></source>
<year>1996</year>
<volume>27</volume>
<page-range>209-210</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bertazzoli]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Widner]]></surname>
<given-names><![CDATA[R. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Lanza]]></surname>
<given-names><![CDATA[M.R.V.]]></given-names>
</name>
<name>
<surname><![CDATA[Di Iglia]]></surname>
<given-names><![CDATA[R.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Sousa]]></surname>
<given-names><![CDATA[F.B.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrolytic removal of metals using a flow-through cell with a reticulated vitreous carbon cathode]]></article-title>
<source><![CDATA[Journal of the Brazilian Society]]></source>
<year>1997</year>
<volume>8</volume>
<page-range>487-493</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Biswas]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Lazarescu]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of oil from emulsions using electrocoagulation]]></article-title>
<source><![CDATA[International Journal of Environmental Studies]]></source>
<year>1991</year>
<volume>38</volume>
<page-range>65-75</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burns]]></surname>
<given-names><![CDATA[S. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Yiacoumi]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Tsouris]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microbubble generation for environmental and industrial separations]]></article-title>
<source><![CDATA[Separation and Purification Technology]]></source>
<year>1997</year>
<volume>11</volume>
<page-range>221-232</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chartrand]]></surname>
<given-names><![CDATA[M.M.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Bunce]]></surname>
<given-names><![CDATA[N.J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrochemical remediation of acid mine drainage]]></article-title>
<source><![CDATA[Journal of Applied Electrochemistry]]></source>
<year>2003</year>
<volume>33</volume>
<page-range>259-264</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ciorba]]></surname>
<given-names><![CDATA[G.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Radovan]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Vlaicu]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Pitulice]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlation between organic component and electrode material: Consequences on removal of surfactants from wastewater]]></article-title>
<source><![CDATA[Electrochimica Acta]]></source>
<year>2000</year>
<volume>46</volume>
<page-range>297-303</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Yue]]></surname>
<given-names><![CDATA[Po L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Novel electrode system for electroflotation of wastewater]]></article-title>
<source><![CDATA[Environmental Science & Technology]]></source>
<year>2002</year>
<volume>36</volume>
<page-range>778-783</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrochemical technologies in wastewater treatment]]></article-title>
<source><![CDATA[Separation and Purification Technology]]></source>
<year>2004</year>
<volume>38</volume>
<page-range>11-41</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Yue]]></surname>
<given-names><![CDATA[L.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Investigation on the electrolysis voltage of electrocoagulation]]></article-title>
<source><![CDATA[Chemical Engineering Science]]></source>
<year>2002</year>
<volume>57</volume>
<page-range>2449-2455</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chowwanapoonpohn]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Chewchanwuttiwong]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Garson]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Buddhasukh]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation and recovery of tannins from tree barks]]></article-title>
<source><![CDATA[Journal of Applied Electrochemistry]]></source>
<year>2003</year>
<volume>33</volume>
<page-range>647-650</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Den]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[C.J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of silica from brackish water by electrocoagulation pretreatment to prevent fouling of reverse osmosis membranes]]></article-title>
<source><![CDATA[Separation and Purification Technology]]></source>
<year>2008</year>
<volume>59</volume>
<page-range>318-325</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deshpande]]></surname>
<given-names><![CDATA[A. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Satyanarayan]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ramakant]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Treatment of high-strength pharmaceutical wastewater by electrocoagulation combined with anaerobic process. Water Science and Technology-WST-61.2.]]></source>
<year>2010</year>
<publisher-name><![CDATA[IWA Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Emamjomeh]]></surname>
<given-names><![CDATA[M.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Sivakumar]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fluoride removal by a continuous flow electrocoagulation reactor]]></article-title>
<source><![CDATA[Journal of Environmental Management]]></source>
<year>2009</year>
<volume>90</volume>
<page-range>1204-1212</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Emamjomeh]]></surname>
<given-names><![CDATA[M.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Sivakumar]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Review of pollutants removed by electrocoagulation and electrocoagulation/flotation processes]]></article-title>
<source><![CDATA[Journal of Environmental Management]]></source>
<year>2009</year>
<volume>90</volume>
<page-range>1663-1679</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghosh]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Medhi]]></surname>
<given-names><![CDATA[C.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Purkait]]></surname>
<given-names><![CDATA[M.K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of fluoride containing drinking water by electrocoagulation using monopolar and bipolar electrode connections]]></article-title>
<source><![CDATA[Chemosphere]]></source>
<year>2008</year>
<volume>73</volume>
<page-range>1393-1400</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gorodovykh]]></surname>
<given-names><![CDATA[V. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Kaplin]]></surname>
<given-names><![CDATA[A. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Svishchenko]]></surname>
<given-names><![CDATA[N. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Obraztsov]]></surname>
<given-names><![CDATA[S. V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Purification of water by electrocoagulation with an alternating asymmetrical current for stripping voltammetry]]></article-title>
<source><![CDATA[Zhurnal Analiticheskoi Khimii]]></source>
<year>1987</year>
<volume>42</volume>
<page-range>1024-1026</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernlem]]></surname>
<given-names><![CDATA[B. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Tsai]]></surname>
<given-names><![CDATA[L. S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chlorine generation and disinfection by electroflotation]]></article-title>
<source><![CDATA[Journal of Food Science]]></source>
<year>2000</year>
<volume>65</volume>
<page-range>834-837</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hosny]]></surname>
<given-names><![CDATA[A.Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Separating oil from oil-water emulsions by electroflotation technique]]></article-title>
<source><![CDATA[Separations Technology]]></source>
<year>1996</year>
<volume>6</volume>
<page-range>9-17</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hossein]]></surname>
<given-names><![CDATA[Mahvi A.]]></given-names>
</name>
<name>
<surname><![CDATA[Bazrafshan]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of Cadmium from Industrial Effluents by Electrocoagulation Process Using Aluminum Electrodes]]></article-title>
<source><![CDATA[World Applied Sciences Journal]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[J. Q.]]></given-names>
</name>
<name>
<surname><![CDATA[Graham]]></surname>
<given-names><![CDATA[N. J. D.]]></given-names>
</name>
<name>
<surname><![CDATA[André]]></surname>
<given-names><![CDATA[C. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Kelsall]]></surname>
<given-names><![CDATA[G. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Brandon]]></surname>
<given-names><![CDATA[N. P.]]></given-names>
</name>
<name>
<surname><![CDATA[Chipps]]></surname>
<given-names><![CDATA[M. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative performance of an electro coagulation/flotation system with chemical coagulation/dissolved air flotation: A pilot-scale trial. Electrolytic treatment of turbid water in package plant]]></article-title>
<source><![CDATA[Water Science and Technology: Water Supply]]></source>
<year>2002</year>
<volume>2</volume>
<page-range>289-297</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jumpatong]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Buddhasukh]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation of some heavy metals]]></article-title>
<source><![CDATA[Contributed paper Chiang Mai Journal of Science]]></source>
<year>2003</year>
<volume>30</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>33-40</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kovatcheca]]></surname>
<given-names><![CDATA[Valeria K.]]></given-names>
</name>
<name>
<surname><![CDATA[Parlapanski Marin]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Sono-electrocoagulation of iron hydroxides]]></article-title>
<source><![CDATA[Colloids and Surfaces A: Physicochemical and Engineering Aspects]]></source>
<year>1999</year>
<volume>149</volume>
<page-range>603-608</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lescuras-Darrou]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Lapicque]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Valentin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrochemical ferrate generation for waste water treatment using cast irons with high silicon contents]]></article-title>
<source><![CDATA[Journal of Applied Electrochemistry]]></source>
<year>2001</year>
<volume>32</volume>
<page-range>57-63</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mameri]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Loucini]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Belhocine]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Grib]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Piron]]></surname>
<given-names><![CDATA[D. L.]]></given-names>
</name>
<name>
<surname><![CDATA[Yahiat]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Defluoridation of sahara water by small plant electro coagulation using bipolar aluminium electrodes]]></article-title>
<source><![CDATA[Separation and Purification Technology]]></source>
<year>2001</year>
<volume>24</volume>
<page-range>113-119</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martín]]></surname>
<given-names><![CDATA[D.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Rivera]]></surname>
<given-names><![CDATA[H.M.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Piña]]></surname>
<given-names><![CDATA[S.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[C.S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Incidencia del gradiente de velocidad en la eficiencia de la electrocoagulación para remover arsénico en un reactor a flujo pistón]]></article-title>
<source><![CDATA[Interciencia, Revista de Ciencia y Tecnología]]></source>
<year>2008</year>
<volume>33</volume>
<page-range>503-509</page-range></nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Matteson]]></surname>
<given-names><![CDATA[Michael J.]]></given-names>
</name>
<name>
<surname><![CDATA[Dobson]]></surname>
<given-names><![CDATA[Regina L.]]></given-names>
</name>
<name>
<surname><![CDATA[Glenn]]></surname>
<given-names><![CDATA[Robert W. Jr.]]></given-names>
</name>
<name>
<surname><![CDATA[Kukunoor]]></surname>
<given-names><![CDATA[S. Nagesh]]></given-names>
</name>
<name>
<surname><![CDATA[Waits]]></surname>
<given-names><![CDATA[William H. III]]></given-names>
</name>
<name>
<surname><![CDATA[Clayfield]]></surname>
<given-names><![CDATA[Eric J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation and separation of aqueous suspensions of ultra fine particles]]></article-title>
<source><![CDATA[Colloids and Surfaces A: Physicochemical and Engineering Aspects]]></source>
<year>1995</year>
<volume>104</volume>
<page-range>101-109</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morante]]></surname>
<given-names><![CDATA[G.G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Electrocoagulación de aguas residuales]]></article-title>
<source><![CDATA[Revista Colombiana de Física]]></source>
<year>2002</year>
<volume>34</volume>
<page-range>484-487</page-range></nlm-citation>
</ref>
<ref id="B32">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morales Posada]]></surname>
<given-names><![CDATA[N.B.]]></given-names>
</name>
<name>
<surname><![CDATA[Acosta Niño]]></surname>
<given-names><![CDATA[G.E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistema de electrocoagulación como tratamiento de aguas residuales galvánicas]]></article-title>
<source><![CDATA[Ciencia e Ingeniería Neogranadina]]></source>
<year>2010</year>
<volume>20</volume>
<page-range>33-44</page-range></nlm-citation>
</ref>
<ref id="B33">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ögütveren]]></surname>
<given-names><![CDATA[Ülker B.]]></given-names>
</name>
<name>
<surname><![CDATA[Koparal]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation for oil-water emulsion treatment]]></article-title>
<source><![CDATA[Journal of Environmental Science and Health]]></source>
<year>1997</year>
<volume>32</volume>
<page-range>2507-2520</page-range></nlm-citation>
</ref>
<ref id="B34">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Paul]]></surname>
<given-names><![CDATA[A. B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrolytic treatment of turbid water in package plant]]></source>
<year>1996</year>
<conf-name><![CDATA[22 WEDC Conference]]></conf-name>
<conf-loc>New Delhi </conf-loc>
<page-range>35-47</page-range></nlm-citation>
</ref>
<ref id="B35">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Parga]]></surname>
<given-names><![CDATA[J.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cocke]]></surname>
<given-names><![CDATA[D.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Valenzuela]]></surname>
<given-names><![CDATA[J.L.]]></given-names>
</name>
<name>
<surname><![CDATA[Gomes]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Kesmez]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Irwin]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Weir]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Arsenic removal via electrocoagulation from heavy metal contaminated groundwater in La Comarca Lagunera México]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>2005</year>
<volume>124</volume>
<page-range>247-254</page-range></nlm-citation>
</ref>
<ref id="B36">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Phutdhawong]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Chowwanapoonpohn]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Buddhasukh]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation and subsequent recovery of phenolic compounds]]></article-title>
<source><![CDATA[Analytical Sciences]]></source>
<year>2000</year>
<volume>16</volume>
<page-range>1083-1084</page-range></nlm-citation>
</ref>
<ref id="B37">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Poon]]></surname>
<given-names><![CDATA[C. P. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electroflotation for groundwater decontamination]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>1997</year>
<volume>55</volume>
<page-range>159-170</page-range></nlm-citation>
</ref>
<ref id="B38">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pouet]]></surname>
<given-names><![CDATA[M. -F.]]></given-names>
</name>
<name>
<surname><![CDATA[Grasmick]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Urban wastewater treatment by electrocoagulation and flotation]]></article-title>
<source><![CDATA[Water Science & Technology]]></source>
<year>1995</year>
<volume>31</volume>
<page-range>275-283</page-range></nlm-citation>
</ref>
<ref id="B39">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pouet]]></surname>
<given-names><![CDATA[M-F]]></given-names>
</name>
<name>
<surname><![CDATA[Persin]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Rumeau]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intensive treatment by electrocoagulation-flotation-tangential flow micro filtration in areas of high seasonal population]]></article-title>
<source><![CDATA[Water Science and Technology]]></source>
<year>1992</year>
<volume>25</volume>
<page-range>247-253</page-range></nlm-citation>
</ref>
<ref id="B40">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ratna]]></surname>
<given-names><![CDATA[Kumar P.]]></given-names>
</name>
<name>
<surname><![CDATA[Chaudhari]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Khilar]]></surname>
<given-names><![CDATA[K.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Mahajan]]></surname>
<given-names><![CDATA[S.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of arsenic from water by electrocoagulation]]></article-title>
<source><![CDATA[Chemosphere]]></source>
<year>2004</year>
<volume>55</volume>
<page-range>1245-1252</page-range></nlm-citation>
</ref>
<ref id="B41">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Renk]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<source><![CDATA[Treatment of Hazardous Wastewaters by Electrocoagulation]]></source>
<year>1988</year>
<publisher-name><![CDATA[Western Research Institute]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B42">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sanfan]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Studies on economic property of pretreatment process of brackish using electrocoagulation (EC) method]]></article-title>
<source><![CDATA[Desalination]]></source>
<year>1991</year>
<volume>82</volume>
<page-range>365-373</page-range></nlm-citation>
</ref>
<ref id="B43">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Subramanyan]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Jothinathan]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Jeganathan]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Ganapathy]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Remediation of phosphate-contaminated water by electrocoagulation with aluminium, aluminium alloy and mild steel anodes]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>2009</year>
<volume>164</volume>
<page-range>1480-1486</page-range></nlm-citation>
</ref>
<ref id="B44">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsai]]></surname>
<given-names><![CDATA[C. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[S. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Shue]]></surname>
<given-names><![CDATA[Y. C.]]></given-names>
</name>
<name>
<surname><![CDATA[Su]]></surname>
<given-names><![CDATA[P. L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrolysis of soluble organic matter in leachate from landfills]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>1996</year>
<volume>31</volume>
<page-range>3073-3081</page-range></nlm-citation>
</ref>
<ref id="B45">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsouris]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[DePaoli]]></surname>
<given-names><![CDATA[D. W.]]></given-names>
</name>
<name>
<surname><![CDATA[Shor]]></surname>
<given-names><![CDATA[J. T.]]></given-names>
</name>
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[M.Z. -C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ying]]></surname>
<given-names><![CDATA[T.-Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation for magnetic seeding of colloidal particles. Colloids and Surfaces]]></article-title>
<source><![CDATA[A: Physicochemical and Engineering Aspects]]></source>
<year>2001</year>
<volume>177</volume>
<page-range>223-233</page-range></nlm-citation>
</ref>
<ref id="B46">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xiong]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Strunk]]></surname>
<given-names><![CDATA[P.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Xia]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Karlson]]></surname>
<given-names><![CDATA[H.T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Treatment of dye wastewater containing acid orange II using a cell with three-phase three-dimensional electrode]]></article-title>
<source><![CDATA[Water Research]]></source>
<year>2001</year>
<volume>35</volume>
<page-range>4226-4230</page-range></nlm-citation>
</ref>
<ref id="B47">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yousuf]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Mollah]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Schennach]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Parga]]></surname>
<given-names><![CDATA[J.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cocke]]></surname>
<given-names><![CDATA[D.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation (EC)-science and applications]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>2001</year>
<volume>84</volume>
<page-range>29-41</page-range></nlm-citation>
</ref>
<ref id="B48">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zaied]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Bellakhal]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electrocoagulation treatment of black liquor from paper industry]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>2009</year>
<volume>30</volume>
<page-range>995-1000</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>