<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0035-001X</journal-id>
<journal-title><![CDATA[Revista mexicana de física]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. mex. fis.]]></abbrev-journal-title>
<issn>0035-001X</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Mexicana de Física]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0035-001X2008000300007</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Transceiver 4-leg birdcage for high field MRI: knee imaging]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Solis]]></surname>
<given-names><![CDATA[S.E]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cuellar]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[R.L]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Tomasi]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodriguez]]></surname>
<given-names><![CDATA[A.O]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Autónoma Metropolitana Centro de Investigación en Instrumentación e Imagenología Médica ]]></institution>
<addr-line><![CDATA[México D.F.]]></addr-line>
<country>México</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Brookhaven National Laboratory Medical Department ]]></institution>
<addr-line><![CDATA[ NY]]></addr-line>
<country>USA</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2008</year>
</pub-date>
<volume>54</volume>
<numero>3</numero>
<fpage>215</fpage>
<lpage>220</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0035-001X2008000300007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0035-001X2008000300007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0035-001X2008000300007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[The radiofrequency coil is a crucial component of the magnetic resonance imaging scanners, so that a solid knowledge on the design and physical characteristics is important for those interested in its development. A birdcage coil with a 10 cm radius and 4 legs (length = 12cm), and a separation between the copper strips of 4 cm, was developed for magnetic resonance imaging (MRI) of the human knee and tuned at the resonance frequency of protons at 4 Tesla (170.3 MHz). MR images were acquired with this coil in phantoms and in the knee of a healthy volunteer using a standard spin echo sequence, The phantom images demonstrated the high uniformity of the radiofrequency field with high signal-to-noise ratio, a characteristic of all birdcage RF coils. The in vivo knee images demonstrated that this birdcage geometry is ideal for knee imaging, promising MR images of the knee with higher spatial resolution at 4 Tesla. This work also demonstrates that volume coils are a good choice for high-field MRI applications.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Las antenas de radio frecuencia son una parte crucial para los sistemas de imagenología por resonancia magnética (IRM), por lo que la adquisición de conocimientos sólidos en el diseño y características es importante para aquellos interesados en su desarrollo. Construimos una antena del tipo jaula para IRM de rodilla humana. El prototipo esta compuesto de un diámetro de 10 cm, 4 elementos cuya longitud es de 12 cm y tienen una separación de 4 cm entre cada elemento y opera a la frecuencia de 170.3 MHz (4 Tesla). La viabilidad de la antena se probó con la adquisición de imágenes por resonancia magnética y de una rodilla sana, junto con secuencias estándar de tipo eco espín. Las imágenes mostraron alta calidad del cociente señal ruido y uniformidad del campo. Las imágenes adquiridas de la rodilla demostraron que la geometría tipo jaula es ideal para obtener imagenes de rodilla con alto cociente señal ruido en altos campos magnéticos. Este trabajo de investigación muestra que las antenas de volumen son una buena opción para aplicaciones de IRM de altos campos.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[knee MRI]]></kwd>
<kwd lng="en"><![CDATA[birdcage coil]]></kwd>
<kwd lng="en"><![CDATA[electromagnetic simulation]]></kwd>
<kwd lng="en"><![CDATA[high field]]></kwd>
<kwd lng="es"><![CDATA[IRM de rodilla]]></kwd>
<kwd lng="es"><![CDATA[antena de jaula de perico]]></kwd>
<kwd lng="es"><![CDATA[simulación electromagnética]]></kwd>
<kwd lng="es"><![CDATA[alto campo]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="justify"><font face="verdana" size="4">Investigaci&oacute;n</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="4"><b>Transceiver 4&#150;leg birdcage for high field MRI: knee imaging</b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="center"><font face="verdana" size="2"><b>S.E. Solis<sup>a,b</sup>, G. Cuellar&ordf;, R.L. Wang<sup>b</sup>, D. Tomasi&ordf;, A.O. Rodriguez&ordf;,</b></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><i>&ordf; Centro de Investigaci&oacute;n en Instrumentaci&oacute;n e Imagenolog&iacute;a M&eacute;dica, Universidad Aut&oacute;noma Metropolitana Iztapalapa, </i><i>M&eacute;xico, D.F. 09340, M&eacute;xico. </i></font></p>     <p align="justify"><font face="verdana" size="2"><i><sup>b </sup>Medical Department, Brookhaven National Laboratory, Upton, NY, 11973, USA.</i></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>* Corresponding author: </b>    ]]></body>
<body><![CDATA[<br> e&#150;mail: <a href="mailto:arog@xanum.uam.mx">arog@xanum.uam.mx</a></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">Recibido el 18 de octubre de 2007    <br> Aceptado el 11 de abril de 2008</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Abstract</b></font></p>     <p align="justify"><font face="verdana" size="2">The radiofrequency coil is a crucial component of the magnetic resonance imaging scanners, so that a solid knowledge on the design and physical characteristics is important for those interested in its development. A birdcage coil with a 10 cm radius and 4 legs (length = 12cm), and a separation between the copper strips of 4 cm, was developed for magnetic resonance imaging (MRI) of the human knee and tuned at the resonance frequency of protons at 4 Tesla (170.3 MHz). MR images were acquired with this coil in phantoms and in the knee of a healthy volunteer using a standard spin echo sequence, The phantom images demonstrated the high uniformity of the radiofrequency field with high signal&#150;to&#150;noise ratio, a characteristic of all birdcage RF coils. The <i>in vivo </i>knee images demonstrated that this birdcage geometry is ideal for knee imaging, promising MR images of the knee with higher spatial resolution at 4 Tesla. This work also demonstrates that volume coils are a good choice for high&#150;field MRI applications.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Keywords: </b>knee MRI; birdcage coil; electromagnetic simulation; high field.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Resumen</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Las antenas de radio frecuencia son una parte crucial para los sistemas de imagenolog&iacute;a por resonancia magn&eacute;tica (IRM), por lo que la adquisici&oacute;n de conocimientos s&oacute;lidos en el dise&ntilde;o y caracter&iacute;sticas es importante para aquellos interesados en su desarrollo. Construimos una antena del tipo jaula para IRM de rodilla humana. El prototipo esta compuesto de un di&aacute;metro de 10 cm, 4 elementos cuya longitud es de 12 cm y tienen una separaci&oacute;n de 4 cm entre cada elemento y opera a la frecuencia de 170.3 MHz (4 Tesla). La viabilidad de la antena se prob&oacute; con la adquisici&oacute;n de im&aacute;genes por resonancia magn&eacute;tica y de una rodilla sana, junto con secuencias est&aacute;ndar de tipo eco esp&iacute;n. Las im&aacute;genes mostraron alta calidad del cociente se&ntilde;al ruido y uniformidad del campo. Las im&aacute;genes adquiridas de la rodilla demostraron que la geometr&iacute;a tipo jaula es ideal para obtener imagenes de rodilla con alto cociente se&ntilde;al ruido en altos campos magn&eacute;ticos. Este trabajo de investigaci&oacute;n muestra que las antenas de volumen son una buena opci&oacute;n para aplicaciones de IRM de altos campos.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Descriptores: </b>IRM de rodilla; antena de jaula de perico; simulaci&oacute;n electromagn&eacute;tica; alto campo.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2">PACS: 87.57.&#150;s; 87.62.+n; 87.61.&#150;c; 84.32</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><a href="/pdf/rmf/v54n3/v54n3a7.pdf" target="_blank">DESCARGAR ART&Iacute;CULO EN FORMATO PDF</a></font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     <p align="justify"><font face="verdana" size="2"><b>Acknowledgments</b></font></p>     <p align="justify"><font face="verdana" size="2">S. E. S. wishes to thank the National Council of Science and Technology of M&eacute;xico (CONACyT) for a Ph. D. scholarship, and grant numbers: 53107, 1&#150;35119 and 1&#150;35106, and Laboratory Directed Research and Development from U.S. Department of Energy (OBER). Support from Innovamedica is gratefully appreciated.</font></p>     <p align="justify"><font face="verdana" size="2">&nbsp;</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><b>References</b></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">1. C.E. Hayes, W.A. Edelstein, J.F. Schenck, and O.M. Mueller, <i>J. Magn. Reson. </i><b>63</b> (1985) 622.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345503&pid=S0035-001X200800030000700001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">2. C.N. Chen, D.I. Hoult, and V.J. Sank, <i>J. Magn. Reson. </i><b>54</b> (1983) 324.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345504&pid=S0035-001X200800030000700002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">3. R.J. Pascone, T. Vullo, J. Farrell, R. Mancuso, P.T. Cahill, <i>Magn. Reson. Imaging. </i><b>11</b> (1993) 705.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345505&pid=S0035-001X200800030000700003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">4. F.D. Doty, G. Entzminger G., C.D. Hauck, and J.P. Staab,  <i>J. Magn. Reson. </i><b>138</b> (1999) 144.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345506&pid=S0035-001X200800030000700004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">5. T. Vullo, R.T. Zipagan, R.J. Pascone, J.P. Whalen, P.T. Cahill, <i>Magn. Reson. Med. </i><b>24</b> (1992) 243.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345507&pid=S0035-001X200800030000700005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">6. R.J. Pascone <i>et al., Magn. Reson. Imaging. </i><b>9</b> (1991) 395.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345508&pid=S0035-001X200800030000700006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">7. G. Giovannetti, L. Landini, and M.F. Santarelli, <i>MAGMA </i><b>15</b> (2002) 36.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345509&pid=S0035-001X200800030000700007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">8. C.L. Chin, C.M. Collins, S. Li, B.J. Dardzinski, and M.B. Smith, <i>Conc. Magn. Reson. Part B: Magn. Reson. Engineering. </i><b>15</b> (2002) 156.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345510&pid=S0035-001X200800030000700008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">9. C.M. Collins, S. Li, Q.X. Yang, and M.B. Smith, J. <i>Mag. Reson. </i><b>125</b> (1997) 233.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345511&pid=S0035-001X200800030000700009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">10. M.D. Harpen, <i>Magn. Reson. Med. </i><b>29</b> (1993) 263.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345512&pid=S0035-001X200800030000700010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">11. W. Schnell, W. Renz, M. Vester, and H. Ermert, <i>IEEE Trans. Ant. Prop. </i><b>48</b> (2000) 418.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345513&pid=S0035-001X200800030000700011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">12. Y. Xu and P. Tang,<i> Magn. Reson. Med. </i><b>38</b> (1997) 168.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345514&pid=S0035-001X200800030000700012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">13. J.C. Watkins and E. Fukushima, <i>Rev. Sci. Instrum.   </i><b>59</b> (1988) 926.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345515&pid=S0035-001X200800030000700013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">14. ANALYZE&ordf;    software.   URL:    <a href="http://www.osirix-viewer.com/" target="_blank">www.mayo.edu/bir/software/Analyze/Analyze.html</a></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345516&pid=S0035-001X200800030000700014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">15. Osirix     medical     imaging     software. URL: <a href="http://www.osirix-viewer.com/" target="_blank">www.osirix&#150;viewer.com</a></font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345517&pid=S0035-001X200800030000700015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">16. J. Jianming, <i>Electromagnetic analysis and design </i>(CRC Press: Boca Raton 1998).</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345518&pid=S0035-001X200800030000700016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">17. J. Jianming, G. Shen, and T. Perkins, <i>Magn. Reson. Med. </i><b>32 </b>(1994) 418.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345519&pid=S0035-001X200800030000700017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">18. E.H.G. Oei, A.Z. Ginai, and M.G.M. Hunink, Sem. <i>US CT MRI. </i><b>28</b> (2007) 141.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345520&pid=S0035-001X200800030000700018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="justify"><font face="verdana" size="2">19. P.M. Cunningham, M. Law, and M.E. Schweitzer, <i>Orthop. Clin. </i>&nbsp;<i>North. Am. </i><b>37</b> (2006) 321.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=8345521&pid=S0035-001X200800030000700019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hayes]]></surname>
<given-names><![CDATA[C.E]]></given-names>
</name>
<name>
<surname><![CDATA[Edelstein]]></surname>
<given-names><![CDATA[W.A]]></given-names>
</name>
<name>
<surname><![CDATA[Schenck]]></surname>
<given-names><![CDATA[J.F]]></given-names>
</name>
<name>
<surname><![CDATA[Mueller]]></surname>
<given-names><![CDATA[O.M]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Magn. Reson]]></source>
<year>1985</year>
<numero>63</numero>
<issue>63</issue>
<page-range>622</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[C.N]]></given-names>
</name>
<name>
<surname><![CDATA[Hoult]]></surname>
<given-names><![CDATA[D.I]]></given-names>
</name>
<name>
<surname><![CDATA[Sank]]></surname>
<given-names><![CDATA[V.J]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Magn. Reson]]></source>
<year>1983</year>
<numero>54</numero>
<issue>54</issue>
<page-range>324</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pascone]]></surname>
<given-names><![CDATA[R.J]]></given-names>
</name>
<name>
<surname><![CDATA[Vullo]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Farrell]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mancuso]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Cahill]]></surname>
<given-names><![CDATA[P.T]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Imaging]]></source>
<year>1993</year>
<numero>11</numero>
<issue>11</issue>
<page-range>705</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Doty]]></surname>
<given-names><![CDATA[F.D]]></given-names>
</name>
<name>
<surname><![CDATA[Entzminger G]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hauck]]></surname>
<given-names><![CDATA[C.D]]></given-names>
</name>
<name>
<surname><![CDATA[Staab]]></surname>
<given-names><![CDATA[J.P]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Magn. Reson]]></source>
<year>1999</year>
<numero>138</numero>
<issue>138</issue>
<page-range>144</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vullo]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zipagan]]></surname>
<given-names><![CDATA[R.T]]></given-names>
</name>
<name>
<surname><![CDATA[Pascone]]></surname>
<given-names><![CDATA[R.J]]></given-names>
</name>
<name>
<surname><![CDATA[Whalen]]></surname>
<given-names><![CDATA[J.P]]></given-names>
</name>
<name>
<surname><![CDATA[Cahill]]></surname>
<given-names><![CDATA[P.T.]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Med]]></source>
<year>1992</year>
<numero>24</numero>
<issue>24</issue>
<page-range>243</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pascone]]></surname>
<given-names><![CDATA[R.J]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Imaging]]></source>
<year>1991</year>
<numero>9</numero>
<issue>9</issue>
<page-range>395</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Giovannetti]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Landini]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Santarelli]]></surname>
<given-names><![CDATA[M.F]]></given-names>
</name>
</person-group>
<source><![CDATA[MAGMA]]></source>
<year>2002</year>
<numero>15</numero>
<issue>15</issue>
<page-range>36</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chin]]></surname>
<given-names><![CDATA[C.L]]></given-names>
</name>
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[C.M]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dardzinski]]></surname>
<given-names><![CDATA[B.J]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[M.B]]></given-names>
</name>
</person-group>
<source><![CDATA[Conc. Magn. Reson. Part B]]></source>
<year>2002</year>
<numero>15</numero>
<issue>15</issue>
<page-range>156</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[C.M]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[Q.X]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[M.B]]></given-names>
</name>
</person-group>
<source><![CDATA[J. Mag. Reson]]></source>
<year>1997</year>
<numero>125</numero>
<issue>125</issue>
<page-range>233</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harpen]]></surname>
<given-names><![CDATA[M.D]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Med]]></source>
<year>1993</year>
<numero>29</numero>
<issue>29</issue>
<page-range>263</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schnell]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Renz]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Vester]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ermert]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans. Ant. Prop]]></source>
<year>2000</year>
<numero>48</numero>
<issue>48</issue>
<page-range>418</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Med]]></source>
<year>1997</year>
<numero>38</numero>
<issue>38</issue>
<page-range>168</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Watkins]]></surname>
<given-names><![CDATA[J.C]]></given-names>
</name>
<name>
<surname><![CDATA[Fukushima]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Rev. Sci. Instrum]]></source>
<year>1988</year>
<numero>59</numero>
<issue>59</issue>
<page-range>926</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="">
<source><![CDATA[ANALYZEª software]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="">
<source><![CDATA[Osirix medical imaging software]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jianming]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Electromagnetic analysis and design]]></source>
<year>1998</year>
<publisher-loc><![CDATA[Boca Raton ]]></publisher-loc>
<publisher-name><![CDATA[CRC Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jianming]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Perkins]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<source><![CDATA[Magn. Reson. Med]]></source>
<year>1994</year>
<numero>32</numero>
<issue>32</issue>
<page-range>418</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oei]]></surname>
<given-names><![CDATA[E.H.G]]></given-names>
</name>
<name>
<surname><![CDATA[Ginai]]></surname>
<given-names><![CDATA[A.Z]]></given-names>
</name>
<name>
<surname><![CDATA[Hunink]]></surname>
<given-names><![CDATA[M.G.M]]></given-names>
</name>
</person-group>
<source><![CDATA[Sem. US CT MRI]]></source>
<year>2007</year>
<numero>28</numero>
<issue>28</issue>
<page-range>141</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cunningham]]></surname>
<given-names><![CDATA[P.M]]></given-names>
</name>
<name>
<surname><![CDATA[Law]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Schweitzer]]></surname>
<given-names><![CDATA[M.E]]></given-names>
</name>
</person-group>
<source><![CDATA[Orthop. Clin. North. Am.]]></source>
<year>2006</year>
<numero>37</numero>
<issue>37</issue>
<page-range>321</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
