<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1405-9940</journal-id>
<journal-title><![CDATA[Archivos de cardiología de México]]></journal-title>
<abbrev-journal-title><![CDATA[Arch. Cardiol. Méx.]]></abbrev-journal-title>
<issn>1405-9940</issn>
<publisher>
<publisher-name><![CDATA[Instituto Nacional de Cardiología Ignacio Chávez]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1405-99402017000100061</article-id>
<article-id pub-id-type="doi">10.1016/j.acmx.2016.10.005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Aumento en la efectividad de la identificación de cimas y pies en el pulso fotopletismográfico al reconstruirlo mediante filtrado adaptativo]]></article-title>
<article-title xml:lang="en"><![CDATA[Increase in the effectiveness of identifying peaks and feet of the photoplethysmographic pulse to be reconstructed it using adaptive filtering]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Becerra-Luna]]></surname>
<given-names><![CDATA[Brayans]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Martínez-Memije]]></surname>
<given-names><![CDATA[Raúl]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cartas-Rosado]]></surname>
<given-names><![CDATA[Raúl]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Infante-Vázquez]]></surname>
<given-names><![CDATA[Oscar]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Instituto Nacional de Cardiología Ignacio Chávez Departamento de Instrumentación Electromecánica ]]></institution>
<addr-line><![CDATA[México, D.F. ]]></addr-line>
<country>México</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Consejo Nacional de Ciencia y Tecnología  ]]></institution>
<addr-line><![CDATA[Ciudad de México ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2017</year>
</pub-date>
<volume>87</volume>
<numero>1</numero>
<fpage>61</fpage>
<lpage>71</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S1405-99402017000100061&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S1405-99402017000100061&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S1405-99402017000100061&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen:  Objetivo:  Mejorar la identificación de cimas y pies en el pulso fotopletismográfico (PPG, por sus siglas en inglés), deformado por efecto del ruido miocinético, mediante la implementación de un dedal modificado y filtrado adaptativo.  Método:  Se obtuvo el PPG en 10 voluntarios sanos empleando 2 sistemas de fotopletismografía colocados en el dedo índice de cada mano, y registrándolos simultáneamente durante 3 min. Durante el primer minuto de registro, ambas manos estuvieron en reposo, y durante los 2 min posteriores, solo la mano izquierda realizó movimientos cuasi-periódicos para añadir ruido miocinético. Se emplearon 2 metodologías para procesar las señales fuera de línea, en una se usó un filtro con el algoritmo de mínimos cuadrados promediados (LMS, por sus siglas en inglés) y en la otra se hizo un preprocesamiento adicional al filtrado LMS. Ambas metodologías fueron comparadas y la de menor error porcentual en la señal recuperada se utilizó para valorar la mejora en la identificación de cimas y pies del PPG.  Resultados:  El error promedio obtenido fue del 22.94% para la primera metodología, y del 3.72% para la segunda. Los errores en la identificación de cimas y pies antes de filtrar el PPG fueron del 24.26 y 48.39%, respectivamente, una vez filtrados, disminuyeron a 2.02 y 3.77%, respectivamente.  Conclusiones:  El filtrado adaptativo basado en el algoritmo LMS, más una etapa de preprocesamiento, permite atenuar el ruido miocinético en el PPG, y aumentar la efectividad en la identificación de cimas y pies de pulso, que resultan de gran importancia para una valoración médica.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract:  Objective:  To improve the identification of peaks and feet in photoplethysmographic (PPG) pulses deformed by myokinetic noise, through the implementation of a modified fingertip and applying adaptive filtering.  Method:  PPG signals were recordedfrom 10 healthy volunteers using two photoplethysmography systems placed on the index finger of each hand. Recordings lasted three minutes andwere done as follows: during the first minute, both handswere at rest, and for the lasting two minutes only the left hand was allowed to make quasi-periodicmovementsin order to add myokinetic noise. Two methodologies were employed to process the signals off-line. One consisted on using an adaptive filter based onthe Least Mean Square (LMS) algorithm, and the other includeda preprocessing stage in addition to the same LMS filter. Both filtering methods were compared and the one with the lowest error was chosen to assess the improvement in the identification of peaks and feet from PPG pulses.  Results:  Average percentage errorsobtained wereof 22.94% with the first filtering methodology, and 3.72% withthe second one. On identifying peaks and feet from PPG pulsesbefore filtering, error percentages obtained were of 24.26% and 48.39%, respectively, and once filtered error percentageslowered to 2.02% for peaks and 3.77% for feet.  Conclusions:  The attenuation of myokinetic noise in PPG pulses through LMS filtering, plusa preprocessing stage, allows increasingthe effectiveness onthe identification of peaks and feet from PPG pulses, which are of great importance for medical assessment.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Algoritmo de mínimos cuadrados promediado]]></kwd>
<kwd lng="es"><![CDATA[Pulso fotopletismográfico]]></kwd>
<kwd lng="es"><![CDATA[Acelerómetro]]></kwd>
<kwd lng="es"><![CDATA[Filtros adaptativos]]></kwd>
<kwd lng="es"><![CDATA[Artefactos por movimiento]]></kwd>
<kwd lng="en"><![CDATA[Least mean square algorithm]]></kwd>
<kwd lng="en"><![CDATA[Photoplethysmographic pulse signal]]></kwd>
<kwd lng="en"><![CDATA[Accelerometer]]></kwd>
<kwd lng="en"><![CDATA[Adaptive filters]]></kwd>
<kwd lng="en"><![CDATA[Motion artifacts]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Globalization, health, and the role of telemedicine]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frenk]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Telemed J E Health]]></source>
<year>2005</year>
<volume>11</volume>
<page-range>291&#8211;5</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Telemedicina en México]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dabaghi-Richerand]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Chávarri]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Torres-Gómez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[An Med Asoc Med Hosp ABC]]></source>
<year>2012</year>
<volume>57</volume>
<page-range>353&#8211;7</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Monitor de señales de electrocardiografía y frecuencia cardiaca mediante un teléfono móvil con el protocolo de comunicación Bluetooth]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Becerra-Luna]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Dávila-García]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Salgado-Rodríguez]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2012</year>
<volume>82</volume>
<page-range>197&#8211;203</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Photoplethysmography and its application in clinical physiological measurement]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Allen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Physiol Meas]]></source>
<year>2007</year>
<volume>28</volume>
<page-range>R1&#8211;39</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elgendi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Brearley]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[PLoS One]]></source>
<year>2013</year>
<volume>8</volume>
<page-range>e76585</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Pi]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>2015</year>
<volume>62</volume>
<page-range>522&#8211;31</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Allen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Physiol Meas]]></source>
<year>2003</year>
<volume>24</volume>
<page-range>297&#8211;307</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Detection of cardiovascular risk from photoplethysmography signal using a matching pursuit algorithm]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sommermeyer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Zou]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ficker]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
</person-group>
<source><![CDATA[Med Biol Eng Comput]]></source>
<year>2015</year>
<page-range>1&#8211;11</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thakor]]></surname>
<given-names><![CDATA[NV]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1991</year>
<volume>38</volume>
<page-range>785&#8211;94</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Photoplethysmographic fingertip with miokinetic noise attenuation using an accelerometer and adaptive filtering techniques]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Becerra-Luna]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Marti&#324;ez-Memije]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Health Care Exchanges (PAHCE)]]></source>
<year>2013</year>
<page-range>1&#8211;5</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ram]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
<name>
<surname><![CDATA[Madhav]]></surname>
<given-names><![CDATA[KV]]></given-names>
</name>
<name>
<surname><![CDATA[Krishna]]></surname>
<given-names><![CDATA[EH]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Instrum Meas]]></source>
<year>2011</year>
<volume>61</volume>
<page-range>1445&#8211;57</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Photoplethysmography-based method for automatic detection of premature ventricular contractions]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Solosenko]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Petrenas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Marozas]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Biomed Circuits Syst]]></source>
<year>2015</year>
<volume>9</volume>
<page-range>662&#8211;9</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cassani]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Mejía]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Tavares]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<source><![CDATA[Adaptive filtering for respiration influence reduction on heart rate variability]]></source>
<year>2011</year>
<conf-name><![CDATA[ 8International Conference Electrical Engineering Computing Science and Automatic Control (CCE)]]></conf-name>
<conf-date>2011</conf-date>
<conf-loc> </conf-loc>
<page-range>1-5</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Adaptive noise cancelling: Principles and applications]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Widrow]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Glover Jr]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[McCool]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Proceedings]]></source>
<year>1975</year>
<volume>63</volume>
<page-range>1692&#8211;716</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haykin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Widrow]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<source><![CDATA[Least mean square adaptive filters]]></source>
<year>2003</year>
<publisher-loc><![CDATA[New Jersey ]]></publisher-loc>
<publisher-name><![CDATA[John Wiley and Sons Inc]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Mechanical factors of cardiovascular risk in systemic arterial hypertension. A new sign of arterial rigidity]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sánchez-Torres]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Infante-Vázquez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez-Miranda]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Arch Cardiol Mex]]></source>
<year>2003</year>
<volume>73</volume>
<page-range>261&#8211;70</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="">
<source><![CDATA[Introducing TracerDAQ, Help Revision 18, Measurement Computing]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Avalos]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Velázquez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Applications of adaptive filtering]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Adaptive Filtering Applications, 1. InTech]]></source>
<year>2011</year>
<page-range>3&#8211;20</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Akay]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Adaptive noise canceling]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Akay]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Biomedical signal processing Orlando]]></source>
<year>1994</year>
<page-range>139&#8211;45</page-range><publisher-loc><![CDATA[Florida ]]></publisher-loc>
<publisher-name><![CDATA[Academic Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="">
<source><![CDATA[MathWorks, Inc QuickStart Matlab Primer R2015b]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[The use of fast Fourier transform for the estimation of power spectra: A method base on time averaging over short, modified periodograms]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Welch]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Audio and Electroaccoust]]></source>
<year>1967</year>
<volume>15</volume>
<page-range>70&#8211;3</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[On the modified Bartlett-Hanning window (family)]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gautam]]></surname>
<given-names><![CDATA[JK]]></given-names>
</name>
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Saxena]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Signal Processing]]></source>
<year>1996</year>
<volume>44</volume>
<page-range>2098&#8211;102</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[On an automatic delineator for arterial blood pressure waveforms]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[BN]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Vai]]></surname>
<given-names><![CDATA[MI]]></given-names>
</name>
</person-group>
<source><![CDATA[Biomed Signal Process Control]]></source>
<year>2009</year>
<volume>5</volume>
<page-range>76&#8211;81</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[The periodic moving average filter for removing motion artifacts from PPG signals]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[HW]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
<name>
<surname><![CDATA[Jung]]></surname>
<given-names><![CDATA[WG]]></given-names>
</name>
</person-group>
<source><![CDATA[Int J Control Autom]]></source>
<year>2007</year>
<volume>5</volume>
<page-range>701&#8211;6</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[GL]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Stein]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
</person-group>
<source><![CDATA[J Med Eng Technol]]></source>
<year>2009</year>
<volume>33</volume>
<page-range>634&#8211;41</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Agreement between noninvasive oximetric values for oxygen saturation]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cahan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Decker]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hoekje]]></surname>
<given-names><![CDATA[PL]]></given-names>
</name>
</person-group>
<source><![CDATA[Chest]]></source>
<year>1990</year>
<volume>97</volume>
<page-range>814&#8211;9</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[ED]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Chan]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
</person-group>
<source><![CDATA[Respir Med]]></source>
<year>2013</year>
<volume>107</volume>
<page-range>789&#8211;99</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[An adaptive Kalman filter for ECG signal enhancement]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vullings]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Vries]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Bergmans]]></surname>
<given-names><![CDATA[JWM]]></given-names>
</name>
</person-group>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>2011</year>
<volume>58</volume>
<page-range>1094&#8211;103</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>