<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-6266</journal-id>
<journal-title><![CDATA[Acta universitaria]]></journal-title>
<abbrev-journal-title><![CDATA[Acta univ]]></abbrev-journal-title>
<issn>0188-6266</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Guanajuato, Dirección de Investigación y Posgrado]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-62662017000200024</article-id>
<article-id pub-id-type="doi">10.15174/au.2017.1023</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Fuzzy control applied to water distribution systems with a view to reducing the waste of water and energy]]></article-title>
<article-title xml:lang="es"><![CDATA[El control fuzzy aplicada a sistemas de suministro de agua con vistas a la reducción de agua de residuos y energía]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[José Kleber Costa de]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Moura]]></surname>
<given-names><![CDATA[Geraldo de Araújo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Henriques]]></surname>
<given-names><![CDATA[Kenny Rogers da Silva]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[Simplício Arnaud da]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gomes]]></surname>
<given-names><![CDATA[Heber Pimentel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidade Federal da Paraíba Postgraduate Program in Mechanical Engineering, Technology Center ]]></institution>
<addr-line><![CDATA[João Pessoa Paraíba]]></addr-line>
<country>Brazil</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2017</year>
</pub-date>
<volume>27</volume>
<numero>2</numero>
<fpage>24</fpage>
<lpage>31</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-62662017000200024&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-62662017000200024&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-62662017000200024&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract This paper presents an application of fuzzy control technique in order to control pressure at entrance of a Water Distribution Pilot Network (RPDA, for its acronym in spanish), mesh with several points of consumption. Same is pressurized by a pump and motor assembly has power variation, which makes it difficult to stabilize control. Fuzzy controller implemented in system selects an optimum condition of operation regarding pressures available and engine output while maintaining pressure for network to meet demand. Evaluation of operating system energy gain with controller action was performed in comparison with operating system without control. Based on these results, fuzzy controller was satisfactory in controlling operating pressure during operation of distribution network.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen Este trabajo se presenta una aplicación de la técnica de control difuso con el objetivo de controlar la presión en la entrada de una Red Piloto de Distribución de Agua (RPDA), malla, con diversos puntos de consumo. La misma se encuentra presurizada por un conjunto motor bomba y presenta variación del consumo, lo que dificulta la estabilización del control. El controlador difuso implantado en el sistema selecciona una condición excelente de operación referente a las presiones disponibles y el rendimiento del motor, manteniendo las presiones de la red constantes, para atender la demanda. La evaluación del logro energético del sistema operando con la acción del controlador fue realizada en comparación con el sistema operando sin control. De acuerdo a los resultados obtenidos, el controlador difuso fue considerado satisfactorio en el control de la presión del servicio durante la operación de la red de distribución.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Fuzzy control]]></kwd>
<kwd lng="en"><![CDATA[energy efficiency]]></kwd>
<kwd lng="en"><![CDATA[water distribution detwork]]></kwd>
<kwd lng="es"><![CDATA[Control difuso]]></kwd>
<kwd lng="es"><![CDATA[eficiencia energética]]></kwd>
<kwd lng="es"><![CDATA[red de distribución de agua]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bakker]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Rajewicz]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Kien]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Vreeburg]]></surname>
<given-names><![CDATA[J. H.]]></given-names>
</name>
<name>
<surname><![CDATA[Rietveld]]></surname>
<given-names><![CDATA[L. C.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Advanced control of a water supply system: A case study]]></article-title>
<source><![CDATA[Water Practice and Technology]]></source>
<year>2014</year>
<volume>9</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>264-76</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berardi]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Laucellii]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Zeng]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Giustolisi]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy saving and leakage control in Water Distribution Networks: A joint research project between Italy And China]]></article-title>
<source><![CDATA[Procedia Engineering]]></source>
<year>2014</year>
<volume>70</volume>
<page-range>152-61</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bezerra]]></surname>
<given-names><![CDATA[S. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[S. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gomes]]></surname>
<given-names><![CDATA[H. P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Otimização operacional de redes de abastecimento de água usando um sistema fuzzy]]></article-title>
<source><![CDATA[Water SA]]></source>
<year>2012</year>
<volume>38</volume>
<numero>4</numero>
<issue>4</issue>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carrijo]]></surname>
<given-names><![CDATA[I. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Reis]]></surname>
<given-names><![CDATA[L. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[P. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Soares]]></surname>
<given-names><![CDATA[A. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[F. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Otimização da operação de sistemas de distribuição de água utilizandoo algorítimos genéticos multiobjetivo]]></article-title>
<source><![CDATA[Anais do XV Congresso Brasileiro de Recursos Hídricos]]></source>
<year>2003</year>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carvalho]]></surname>
<given-names><![CDATA[P. S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Controle para bombeamento distribuído com vistas à minimização dos custos energéticos aplicado a sistemas de abastecimentos de água]]></source>
<year>2012</year>
<publisher-name><![CDATA[Universidade Federal da Paraíba]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Creaco]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Franchini]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A new algorithm for real-time pressure control in water distribution networks]]></article-title>
<source><![CDATA[Water Science and Technology: Water Supply]]></source>
<year>2013</year>
<volume>13</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>875-82</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schwaller]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[van Zil]]></surname>
<given-names><![CDATA[J. E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Modeling the pressure-leakage response of water distribution systems based on individual leak behavior]]></article-title>
<source><![CDATA[Journal of Hydraulic Engineering]]></source>
<year>2014</year>
<volume>141</volume>
<numero>5</numero>
<issue>5</issue>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Dong]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
</person-group>
<source><![CDATA[Control System Desing for Contant Pressure Water Supply]]></source>
<year>2010</year>
<conf-name><![CDATA[ secondInternational Conference on Multimedia and Information Technology]]></conf-name>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>