<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0188-4999</journal-id>
<journal-title><![CDATA[Revista internacional de contaminación ambiental]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. Int. Contam. Ambient]]></abbrev-journal-title>
<issn>0188-4999</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional Autónoma de México, Instituto de Ciencias de la Atmósfera y Cambio Climático]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0188-49992020000200465</article-id>
<article-id pub-id-type="doi">10.20937/rica.53452</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[ENSAYOS MECÁNICOS SOBRE MORTEROS CON AGREGADOS DE PLÁSTICO RECICLADO DOSIFICADOS SEGÚN MODELO DE CONDUCTIVIDAD TÉRMICA]]></article-title>
<article-title xml:lang="en"><![CDATA[MECHANICAL TESTS ON MORTARS WITH RECYCLED PLASTIC AGGREGATES DOSED UNDER A MODEL OF THERMAL CONDUCTIVITY]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ojeda]]></surname>
<given-names><![CDATA[Juan Pablo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mercante]]></surname>
<given-names><![CDATA[Irma Teresa]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fajardo]]></surname>
<given-names><![CDATA[Nicolás Horacio]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Nacional de Cuyo Instituto de Medio Ambiente, Facultad de Ingeniería Centro de Estudios de Ingeniería de Residuos Sólidos]]></institution>
<addr-line><![CDATA[Mendoza ]]></addr-line>
<country>Argentina</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2020</year>
</pub-date>
<volume>36</volume>
<numero>2</numero>
<fpage>465</fpage>
<lpage>474</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_arttext&amp;pid=S0188-49992020000200465&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_abstract&amp;pid=S0188-49992020000200465&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.mx/scielo.php?script=sci_pdf&amp;pid=S0188-49992020000200465&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Los residuos de plástico constituyen el 10 % de los residuos sólidos a nivel mundial. El uso de agregados de plástico en el hormigón mejora algunas propiedades como el aislamiento térmico y el peso específico, aunque produce disminución de la resistencia a la compresión. En este trabajo se dosificaron mezclas con agregados de plástico reciclado de origen residual para satisfacer requisitos de aislamiento térmico. Para ello se desarrolló un modelo simplificado, calculando los espesores de plástico requeridos en un muro equivalente de 18 cm de espesor. Luego se moldearon probetas y se ensayaron a flexión y compresión. Los resultados confirmaron que la incorporación de plástico produjo una caída de la resistencia a la compresión y la flexión, excepto en el caso de gránulos (pellets). Se requirió un espesor teórico de plástico -con el modelo de muro multicapa propuesto- de 2.4 a 6 cm para lograr el aislamiento térmico deseado, frente a los 37 cm que hubiese requerido un muro realizado exclusivamente con mortero. Sin embargo, sólo una mezcla alcanzó la resistencia mínima requerida para la construcción de paneles. Se concluyó que los agregados redondeados exhibieron mejor comportamiento que los agregados con forma de hojuelas y que el modelo utilizado para la dosificación de agregados de plástico debería ser mejorado y contrastado con resultados experimentales en un trabajo futuro.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT Plastic waste constitutes 10 % of the solid waste worldwide. The use of plastic aggregates in concrete improves some properties such as thermal insulation and specific weight, although it produces a decrease in strength. In this work, mixtures with plastic aggregates of residual origin were dosed to satisfy thermal insulation requirements. For this purpose, a simplified model was made, calculating the required plastic thicknesses in an equivalent wall of 18 cm thick. Then, specimens were molded and tested by bending and compression. The results confirmed that the incorporation of plastic produced a drop in compressive and flexural strength, except in the case of pellets. Under the proposed multilayer wall model, a theoretical thickness of plastic between 2.4 and 6 cm was required to achieve the desired thermal insulation, compared to 37 cm that a wall exclusively made of mortar would have required. However, only one mix reached the minimum strength required for the construction of panels. It was concluded that the rounded aggregates exhibited better behavior than the leaf-shaped aggregates and that the model used for the dosage of plastic aggregates should be improved and contrasted with experimental results in a future paper.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[aislamiento térmico]]></kwd>
<kwd lng="es"><![CDATA[residuos sólidos]]></kwd>
<kwd lng="es"><![CDATA[materiales de construcción]]></kwd>
<kwd lng="es"><![CDATA[mezclas cementicias]]></kwd>
<kwd lng="en"><![CDATA[thermal insulation]]></kwd>
<kwd lng="en"><![CDATA[solid waste]]></kwd>
<kwd lng="en"><![CDATA[construction materials]]></kwd>
<kwd lng="en"><![CDATA[cementitious mixtures]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Batayneh]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Marie]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Asi]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Use of selected waste materials in concrete mixes]]></article-title>
<source><![CDATA[Waste Manage.]]></source>
<year>2007</year>
<volume>27</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1870-6</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Casanova-del Ángel]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Vázquez-Ruiz]]></surname>
<given-names><![CDATA[J.L.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Manufacturing light concrete with PET aggregate]]></article-title>
<source><![CDATA[International Scholarly Research Network Civil Engineering]]></source>
<year>2012</year>
<volume>2012</volume>
<page-range>287323</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Charca]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Noel]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Andia]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Guzman]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Renteros]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Tumialan]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Assessment of Ichu fibers as non-expensive thermal insulation system for the Andean regions]]></article-title>
<source><![CDATA[Energ. Buildings.]]></source>
<year>2015</year>
<volume>108</volume>
<page-range>55-60</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chikhi]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Agoudjil]]></surname>
<given-names><![CDATA[B.]]></given-names>
</name>
<name>
<surname><![CDATA[Boudenne]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Gherabli]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Experimental investigation of new biocomposite with low cost for thermal insulation]]></article-title>
<source><![CDATA[Energ. Buildings.]]></source>
<year>2013</year>
<volume>66</volume>
<page-range>267-73</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[Y.W.]]></given-names>
</name>
<name>
<surname><![CDATA[Moon]]></surname>
<given-names><![CDATA[D.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[J.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[S.K.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effects of waste PET bottles aggregate on the properties of concrete]]></article-title>
<source><![CDATA[Cement Concrete Res.]]></source>
<year>2005</year>
<volume>35</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>776-81</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="book">
<collab>CUE</collab>
<source><![CDATA[Cerrar el círculo: la Comisión adopta un ambicioso paquete de nuevas medidas sobre la economía circular para impulsar la competitividad, crear empleo y generar crecimiento sostenible]]></source>
<year>2015</year>
<publisher-name><![CDATA[Comisión Unión Europea]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Frigione]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Recycling of PET bottles as fine aggregate in concrete]]></article-title>
<source><![CDATA[Waste Manage.]]></source>
<year>2010</year>
<volume>30</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1101-6</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gaggino]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Argüello]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Building components made from recycled plastics]]></article-title>
<source><![CDATA[Key Eng. Mat.]]></source>
<year>2014</year>
<volume>600</volume>
<page-range>615</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="book">
<collab>Goodfellow</collab>
<source><![CDATA[Catálogo de polímeros - propiedades térmicas. Catálogo]]></source>
<year>2018</year>
<page-range>28</page-range><publisher-loc><![CDATA[Cambridge, Inglaterra ]]></publisher-loc>
<publisher-name><![CDATA[Goodfellow]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<collab>ISWA</collab>
<source><![CDATA[Globalisation and Waste Management]]></source>
<year>2014</year>
<page-range>55</page-range><publisher-loc><![CDATA[Viena, Austria ]]></publisher-loc>
<publisher-name><![CDATA[International Solid Waste Association]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<collab>INTI</collab>
<article-title xml:lang=""><![CDATA[Centro de Investigación de los Reglamentos Nacionales de Seguridad para las Obras Civiles (CIRSOC) 202. Hormigón Liviano de Estructura Compacta]]></article-title>
<source><![CDATA[Instituto Nacional de Tecnología Industrial]]></source>
<year>1982</year>
<page-range>89</page-range><publisher-loc><![CDATA[Argentina ]]></publisher-loc>
<publisher-name><![CDATA[Ciudad Autónoma de Buenos Aires]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<collab>IRAM</collab>
<article-title xml:lang=""><![CDATA[Norma 11605. Acondicionamiento térmico de edificios. Condiciones de habitabilidad en edificios. Valores máximos de transmitancia térmica en cerramientos opacos]]></article-title>
<source><![CDATA[Instituto Argentino de Normalización y Certificación. Ciudad Autónoma de Buenos Aires]]></source>
<year>1996</year>
<page-range>27</page-range><publisher-loc><![CDATA[Argentina ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<collab>IRAM</collab>
<article-title xml:lang=""><![CDATA[Norma 11601. Aislamiento térmico de edificios. Método de cálculo. Propiedades térmicas de los componentes y elementos de construcción en régimen estacionario]]></article-title>
<source><![CDATA[Instituto Argentino de Normalización y Certificación. Ciudad Autónoma de Buenos Aires]]></source>
<year>2002</year>
<page-range>52</page-range><publisher-loc><![CDATA[Argentina ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<collab>IRAM</collab>
<article-title xml:lang=""><![CDATA[Norma 1622. Cemento portland. Determinación de resistencias mecánicas]]></article-title>
<source><![CDATA[Instituto Argentino de Normalización y Certificación. Ciudad Autónoma de Buenos Aires]]></source>
<year>2015</year>
<page-range>25</page-range><publisher-loc><![CDATA[Argentina ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ismail]]></surname>
<given-names><![CDATA[Z.Z.]]></given-names>
</name>
<name>
<surname><![CDATA[AL-Hashmi]]></surname>
<given-names><![CDATA[E.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Use of waste plastic in concrete mixture as aggregate replacement]]></article-title>
<source><![CDATA[Waste Manage.]]></source>
<year>2008</year>
<volume>28</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2041-7</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mercante]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Ojeda]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Alejandrino]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Chini]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Revisión bibliográfica: Hormigón con agregados de plástico reciclados]]></source>
<year>2017</year>
<conf-name><![CDATA[ VII Simposio Iberoamericano en Ingeniería de Residuos]]></conf-name>
<conf-date>13 y 14 de junio</conf-date>
<conf-loc>Santander, España </conf-loc>
<page-range>136-41</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[San-Juan]]></surname>
<given-names><![CDATA[G.A.]]></given-names>
</name>
<name>
<surname><![CDATA[Viegas]]></surname>
<given-names><![CDATA[G.M.]]></given-names>
</name>
<name>
<surname><![CDATA[Jodra]]></surname>
<given-names><![CDATA[J.I.]]></given-names>
</name>
</person-group>
<source><![CDATA[Aislación térmica alternativa, reutilizando poliestireno expandido de descarte, orientado a las necesidades de cooperativas de reciclado]]></source>
<year>2018</year>
<conf-name><![CDATA[ X Congreso Regional de Tecnología en Arquitectura (CRETA)]]></conf-name>
<conf-date>29, 30 y 31 de agosto</conf-date>
<conf-loc>La Plata, Argentina </conf-loc>
<page-range>391-400</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Viegas]]></surname>
<given-names><![CDATA[G. M.]]></given-names>
</name>
<name>
<surname><![CDATA[Walsh]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Barros]]></surname>
<given-names><![CDATA[M.V.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluación cuali-cuantitativa de aislaciones térmicas alternativas para viviendas: el caso de la agricultura familiar]]></article-title>
<source><![CDATA[Revista INVI]]></source>
<year>2016</year>
<volume>31</volume>
<numero>86</numero>
<issue>86</issue>
<page-range>89-117</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
