Sistema Informático para Análisis de Cardiopatía Holter

 

Computer System for Analysis of Holter Cardiopathy

 

Jesús Antonio Álvarez Cedillo, Juan Carlos Herrera Lozada y Patricia Pérez Romero

 

Centro de Innovación y Desarrollo Tecnológico en Cómputo del Instituto Politécnico Nacional, México, D.F. (e–mail: jaalvarez@ipn.mx, jlozada@ipn.mx, promerop@ipn.mx).

 

Manuscrito recibido el 8 de febrero del 2010.
Manuscrito aceptado para su publicación el 31 de mayo del 2010.

 

Resumen

El presente artículo, muestra los avances de desarrollo de una herramienta médica relacionada con los estudios de cardiopatía que esté disponible y al alcance de cualquier hospital, centro médico, o consultorio médico, que sea accesible en el costo, de fácil manejo y comprensible. Como un beneficio para el paciente, este proyecto le permitiría tener un mayor acceso a este tipo de estudios. Este proyecto también permite apoyar al médico profesional en cuanto a obtener en ciertos casos, un posible diagnóstico.

Palabras clave: Holter electrocardiográfico, cardiopatía.

 

Abstract

This paper presents the development of a medical tool related to cardiopathy studies that is available and accessible to any hospital, medical center, or doctor's office, which is accessible at low cost, user friendly and understandable. As a benefit for patients, this project allows major accessibility of the corresponding medical studies. This project also allows to the medical professional obtaining in certain cases a possible diagnosis.

Key words: Holter electrocardiography, cardiopathy.

 

DESCARGAR ARTÍCULO EN FORMATO PDF

 

REFERENCIAS

[1] C. M. Agulhari, R. M. R. Silveira, and I. S. Bonatti, Lossless compression applied to sequences of bits, Technical report, Unicamp, Brazil, 2007. Available: http://www.dt.fee.unicamp.br/~ivanil/lossless_bitmap_agulhari_2007.pdf.         [ Links ]

[2] A. Alshamali and A. S. Al–Fahoum. "Comments on An efficient coding algorithm for the compression of ECG signals using the wavelet transform," IEEE Transactions on Biomedical Engineering, 50 (8), 1034–1037, Aug. 2003.         [ Links ]

[3] C. Rodriguez, S. Borromeo, R. de la Prieta, J. A. Hernández, N. Malpica, "Wireless ECG based on Bluetooth protocol: design and implementation," in Proc. of IEEE int. conf. on Information Technologies in Biomedicine, Ionannina, Greece, Oct. 2006.         [ Links ]

[4] P. Bifulco, G. Gargiulo, "Bluetooth Portable Device for Continuous ECG and Patient Motion Monitoring During Daily Life," Medicon 2007 IFMBE Proceedings 16, 2007, pp.369–372.         [ Links ]

[5] V. Noparrat, P. Keeratiwintakorn "The Three–Lead Wireless ECG in Sensor Networks for Mobile Patients," in SICE Annual Conference Japan, August 20–22, 2008.         [ Links ]

[6] Harri Kailanto, Esko Hyvärinen, and Jari Hyttinen, "Mobile ECG measurement and Analysis System Using Mobile Phone as the Base Station." in Proc. of Second International Conference on Pervasive Computing Technologies for Healthcare, 2008.         [ Links ]

[7] F. Sufi, Q. Fang and I. Cosic, "ECG R–R Peak Detection on Mobile Phones," in Proceedings of the 29th Annual International Conference of the IEEEEMBS Cité Internationale, Lyon, France, August 23–26, 2007.         [ Links ]

[8] S. Arslan and K. Kose, "A Design of DSPIC Based Signal Monitoring and Processing System," Journal of Electrical and Electronics Engineering. number 1, volume 9. 2009.         [ Links ]

[9] F. Spadini and F. Vergari, "A Wireless and Context–Aware ECG Monitor : An iMote2 Based Portable System," Computers in Cardiology 35, pp. 997––1000, 2008.         [ Links ]

[10] H. Ming , Z. Yajun , and H. Xiaoping, "Portable ECG Measurement Device based on MSP430 MCU," in Proceedings of the 2008 International Conference on BioMedical Engineering and Informatics, May 27–30, 2008, p.667–671.         [ Links ]

[11] J. Zhu , N. Rao , D. Liang , and W. Chen, "Design of Pre–processing Circuit for Wireless ECG Monitoring System," in Proceedings of the 2008 International Conference on BioMedical Engineering and Informatics, May 27–30, 2008, pp. 598–602.         [ Links ]

[12] A. Tahat, "Mobile Personal Electrocardiogram Monitoring System and Transmission Using MMS," in Proceedings of the 7th International Caribbean Conference on Devices, Circuits and Systems, Mexico, Apr. 2008, pp. 28–30.         [ Links ]

[13] P. Frehill and D. Chambers. "Using Zigbee to Integrate Medical Devices," in Proceedings of the 29th Annual International Conference of the IEEE EMBS Cité Internationale, Lyon, France, August 2007, pp.23–26.         [ Links ]

[14] S. Pavel, M. Pavlik, and R. Vrba, "Smart Differential Pressure Sensor with Bluetooth Communication Interface," in Proceedings of the Third International Conference on Systems, April 13–18, 2008, pp.363–367.         [ Links ]

[15] M. J. Moron, R. Luque, E. Casilari and A. Díaz–Estrella, "Analysis of Bluetooth Transmission Delay in Personal Area Networks," IEEE, 2008.         [ Links ]

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License