SciELO - Scientific Electronic Library Online

 
vol.59 issue1Alternative method to calculate the magnetic field of permanent magnets with azimuthal symmetrySpatial location in 360° of reference points over an object by using stereo vision author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista mexicana de física E

Print version ISSN 1870-3542

Rev. mex. fís. E vol.59 n.1 México Jan./Jun. 2013

 

Education

 

Interface para esqueletizado y suavizado de interferogramas

 

D. H. Penalver-Vidal, D. L. Romero-Antequera y F. S. Granados-Agustín

 

Instituto Nacional de Astrofísica, Óptica y Electrónica Calle Luis Enrique Erro No. 1. Tonantzintla, Puebla, 72000, México.

 

Received 21 March 2012;
Accepted 22 November 2012.

 

Resumen

Se desarrolla una interfaz gráfica para brindar una herramienta computacional de rápido y fiícil manejo para el suavizado y/o esqueletizado de imagenes interferometricas. El código de la interfaz esta basado en un algoritmo de suavizado para interferogramas, en donde se plantea ajustar la distribucion de intensidad de las columnas o filas de imagenes interferometricas mediante mínimos cuadrados, usando como base las funciones de Bessel de primer orden, eliminando así las componentes de ruido de alta frecuencia. Adicionalmente, se utiliza el metodo de dilatacion por medio de un elemento estructural de Strehl para alcanzar el esqueletizado de los interferogramas.

Descriptores: Óptica; esqueletización de interferogramas; algoritmo.

 

Abstract

It is developed a GUI (graphical user interface) in order to provide a fast and easy to use computational tool, which performs smoothing and/or skeletonizing of interferometric images. The code used in the interface is based in smoothing algorithms for interferograms, where the intensity distribution along rows or columns of the image is fitted by means of least squares and using Bessel functions of the first kind as basis functions, allowing the suppression of high frequency noise components. Additionally, the dilation method is used using a Strehl structural element in order to perform skeletonizing of the interferograms.

Keywords: Skelotonizing; interferometry; interferogram smoothing.

PACS: 42.87.-d; 07.05.Pj; 42.25.Hz.

 

DESCARGAR ARTÍCULO EN FORMATO PDF

 

Agradecimientos

Los autores agradecen las sugerencias del revisor del trabajo, asimismo Romero-Antequera y Penalver-Vidal, agradecen al CONCYT por el apoyo recibido a traves de las becas de doctorado con numeros 223982 y 23980, respectivamente.

 

Bibliografía

1. T. Kreis, Handbook of Holographic Interferometry (WILEY-VCH GmbH and Co. KGaA,Weinheim, 2005). pp. 229-234.         [ Links ]

2. H.E. Cline, W. E. Lorensen, y A. S. Holik Appl Opt. 23 (1984).         [ Links ]

3. F. Zhang, M. Shu, y P. Chen, Proceedings of the Society of Photo-Optical Instrumentation Engineers 814 (1987) 806.         [ Links ]

4. K. Ramesh y R. K. Singh, J Electron Imaging 4 (1995)71.         [ Links ]

5. E. Umezaki, T. Tamakai, S. Takahashi Exp Tech. 13 (1989) 22.         [ Links ]

6. D. H. Penalver, D. L. Romero-Antequera, F.-Salomón y G.Agustín, Opt. Eng. 51 (2012) 045601.         [ Links ]

7. D. Malacara. " Optical Shop Testing" Third Edition (A John Wiley & Sons, Inc., Publication 2007).         [ Links ]

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License