Services on Demand
Journal
Article
Indicators
- Cited by SciELO
- Access statistics
Related links
- Similars in SciELO
Share
Revista mexicana de física
Print version ISSN 0035-001X
Rev. mex. fis. vol.51 n.2 México Apr. 2005
Investigación
EPR of borax-alanine mixtures irradiated with thermal neutrons
S. Galindo* and J. Klappt†
Departamento de Física, Instituto Nacional de Investigaciones Nucleares, ININ, Km. 36.5 Carretera México-Toluca, 52045 Estado de México, Mex. *sgu@nuclear.inin.mx, †klapp@nuclear.inin.mx
Recibido el 1 de septiembre de 2004;
aceptado el 12 de noviembre de 2004
Abstract
Electron Paramagnetic Resonance (EPR) of neutron irradiated crystallite mixtures of alanine and borax is reported. These experiments are aimed at establishing an EPR dosimetry technique for thermal neutrons based on the resonance signal enhancement of alanine due to the boron content in the mixtures via a neutron capture reaction. Signal response as a function of boron content and crystallite size of the mixtures is presented.
Keywords: Electron paramagnetic resonance; free radicals; neutron dosimetry.
Resumen
Se reporta la Resonancia Paramagnética Electrónica (EPR) de mezclas de alanina y borax irradiadas con neutrones. El objetivo de estos experimentos es establecer una técnica de dosimetría EPR para neutrones térmicos basada en el incremento de la serial de alanina debido al contenido de boro en las mezclas vía una reacción de captura neutrónica. Se presenta la respuesta de la señal como función del contenido de boro y del tamaño de los cristalitos de las mezclas.
Descriptores: Resonancia paramagnética; radicales libres; dosimetría de neutrones.
PACS: 76.30.Rn; 87.53.Pb
DESCARGAR ARTÍCULO EN FORMATO PDF
Acknowledgments
We value the assistance of the TRIGA Mk III Nuclear Reactor personnel and management. This work is partially supported by the mexican Consejo Nacional de Ciencia y Tecnología (CONACYT) under contracts U43534-R and J200.476/2004.
References
1. ASTM Designation E1607-94, Annual book of ASTM Standards, vol. 12.02, American Society for Testing and Materials "Standard practice for the use of Alanine-EPR dosimetry system" (1994). [ Links ]
2. S. Galindo and F. Ureña-Nuñez, Radiat. Res 133 (1993) 389. [ Links ]
3. I. Riyad and C. F. Callis, "Particle size: measurement, interpretation and application". John Wiley & Sons N.Y. (1963). [ Links ]
4. J.F. Ziegler and F. Biersack, "TRIM-90 (v. 6.0)". This code is based on a paper by J.F. Ziegler and J.M. Mayonan, Nucl. Instrum Methods B35 (1988) 215. [ Links ]
5. J. Flores M and S. Galindo, Radiat. Res. 125 (1991) 335. [ Links ]
6. I. Janovský, J. W. Hansen and P. Cernoch, Appl. Radiat. Isot. 39 (1988)651. [ Links ]
7. F. Ureña-Muñez, S. Galindo and J. Azorín, Appl. Radiat. Isot. 50 (1999) 760. [ Links ]
8. F. Ureña-Nuñez, S. Galindo and J. Azorín, Appl. Radiat. Isot. 50 (1999) 763. [ Links ]