SciELO - Scientific Electronic Library Online

 
vol.32 número3Prevalencia de la deficiencia e insuficiencia de vitamina D en pacientes con sepsis y choque séptico en un hospital de tercer nivel índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Medicina crítica (Colegio Mexicano de Medicina Crítica)

versión impresa ISSN 2448-8909

Resumen

TORRES GOMEZ, Erik; MENDOZA PORTILLO, Elizabeth  y  MENDOZA RODRIGUEZ, Martín. Index asynchrony/brain natriuretic peptide as a predictor of successful extubation in patients with chest trauma. Med. crít. (Col. Mex. Med. Crít.) [online]. 2018, vol.32, n.3, pp.121-125.  Epub 27-Mar-2020. ISSN 2448-8909.

Background:

Chest trauma (CT) requires specific mechanical ventilation (MV) strategies; weaning is a complex situation. Ventilatory asynchrony (VA) implies an increased morbimortality, not described in the Mexican population.

Aim:

To correlate the index of asynchrony (IA)/brain natriuretic peptide (BNP), (IABNP), with the result of extubation in patients with chest trauma.

Material and methods:

A longitudinal study was done in intensive care units (ICU), 30 patients were included; the following variables were evaluated: demographics, type of trauma, IA, BNP before (BNP1) and after (BNP2) extubation, as well as IA/BNP as a scale to predict extubation. Endpoint: success or failure of the extubation (reintubation in next 48 hours).

Results:

The study population was 96.7% masculine, 3.3% female; age: 34.4 ± 11.2 years. Successful withdrawal of MV was 70%. Type of trauma was pneumo/hemothorax 40%, hemothorax 16.7%, pneumothorax 10%, flail chest/pulmonary contusion 10%, other types 23.3%. BPN1: 44.2 ± 23.2 pg/dL, BNP2: 67 ± 49 pg/dL, IA: 13 ± 2%, IA/BNP: 0.28 ± 0.15, rapid surface respiration index (IVRS): 83.2 ± 13.1, maximum inspiration pressure (MIP): -24.2 ± 3.07, P 0.1-3.9 ± 0.7. Pearson correlation for IA and BNP1 was r = 0.71, the determination index: r2= 0.50, with significance p < 0.001, confidence interval (CI) 95%; for AI and BNP2: r = 0.83, r2 = 0.68, p < 0.001, CI 95%. Spearman correlation for IA/BNP and failure: r = 0.62, and determination index: r2 = 0.39, with significance p < 0.001, CI 95%; for RSSR and failure: r = 0.31, r2 = 0.09, with p < 0.094, CI 95%. IA/BNP < 0.14 was related with failure at extubation.

Conclusions:

IA/BNP < 0.14 was a predictive marker for failure of weaning MV in the first 48 hours compared with the traditional RSRR, which was not statistically significant.

Palabras llave : Asynchrony; BNP; extubation; chest trauma; mechanical ventilation.

        · resumen en Español | Portugués     · texto en Español     · Español ( pdf )