SciELO - Scientific Electronic Library Online

 
vol.32 número2Biomarcadores de microcirculação vs escala sofa como preditores de mortalidade em choque septicoProva de estresse com furosemida para prever o êxito ou fracasso da remoção da terapia contínua de substituição renal na lesão renal aguda índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Medicina crítica (Colegio Mexicano de Medicina Crítica)

versão impressa ISSN 2448-8909

Resumo

CALZADA TORRES, Pablo; MONTELONGO, Felipe de Jesús; NAVA LOPEZ, Jorge Arturo  e  CARMONA DOMINGUEZ, Aurea. Efficiency and safety of placement of pulmonary artery catheter guided by ultrasound. Med. crít. (Col. Mex. Med. Crít.) [online]. 2018, vol.32, n.2, pp.76-84. ISSN 2448-8909.

Background:

Use of a pulmonary artery catheter (Swan-Ganz) has been discussed because it does not offer changes in the mortality of critically ill patients; however, it is still a useful tool for hemodynamic monitoring.

Objective:

To offer an alternative in the placement of Swan-Ganz catheter by ultrasound in less time and without complications.

Material and methods:

A pilot, prospective, observational, cross-sectional and descriptive study was conducted. Placing 26 patients with various pathologies that required aminergic or inotropic delivery, a pulmonary artery catheter; evaluating placement times and associated complications after placement.

Results:

A mean of 91.46 seconds of placement (range of 60-122 seconds) was obtained after insertion of the tip of the catheter by venodisection and 0% of complications in 26 patients.

Discussion:

The use of ultrasound offers an alternate method of placement of the catheter without fluoroscopy support, monitoring curves or intracavitary pressures; and reduces complications.

Conclusions:

The placement of Swan-Ganz by ultrasound is an alternative and safe method for placement with an average time of 91 seconds in its insertion. A larger sample is required to determine if the method is effective and perhaps a multicenter study.

Palavras-chave : Swan Ganz catheter; FATE protocol; pulmonary artery.

        · resumo em Português | Espanhol     · texto em Espanhol     · Espanhol ( pdf )