SciELO - Scientific Electronic Library Online

 
vol.90 número2Precisión de la calculadora de riesgo quirúrgico ACS NSQIP para predecir morbilidad y mortalidad en pacientes mexicanosHeridas por asta de toro, análisis de 138 casos índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Cirugía y cirujanos

versão On-line ISSN 2444-054Xversão impressa ISSN 0009-7411

Resumo

ROJAS-MURILLO, Tania  e  OLVERA-GONZALEZ, Natael. Relationship between the measurement by tomography and ultrasound of the diameter of the optic nerve sheath as a non-invasive estimator of intracranial pressure. Cir. cir. [online]. 2022, vol.90, n.2, pp.236-241.  Epub 02-Maio-2022. ISSN 2444-054X.  https://doi.org/10.24875/ciru.20001199.

Objective:

To compare the ONSD measured by ultrasound and tomography in patients with a diagnosis of intracranial hypertension.

Method:

Prospective, transversal, observational, analytical study. 105 patients were included, divided into two groups: healthy (control group) and patients presenting clinical data of intracranial hypertension (study group). ONSD was measured by ultrasound and tomography. The Kruskal-Wallis test was used to compare the ONSD between the patients, and the Spearman test was used to assess the correlation between USG and CT. A value of p <0.05 was considered statistically significant.

Results:

Of the 105 patients, 58.1% were men and 41.9% women. The study group included 14 patients with TBI, CVD, intracranial neoplasia, or neuroinfection. The highest median of ONSD by Ultrasound was in the CVD group, followed by TBI, neoplasia and neuroinfection and the lowest was in the control group (7.5, 7.0, 6.8, 6.8 and 5.2 mm respectively); these differences being statistically significant (p < 0.001). In the correlation analysis between Ultrasound and CT, a good statistically significant positive correlation was found (rho = 0.893, p < 0.001).

Conclusions:

The ultrasound evaluation of ONSD has proven to be a reliable test for the diagnosis and non-invasive monitoring of intracranial hypertension.

Palavras-chave : Neuromonitoring; Optic nerve; Intracranial pressure.