SciELO - Scientific Electronic Library Online

 
vol.87 issue5Volumetric measurement of the acetabular cavity in patients with unilateral neglected developmental dysplasia of the dislocated hip operated in a single timeResults and complications of carotid endarterectomy in a hospital from Madrid, Spain author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Cirugía y cirujanos

On-line version ISSN 2444-054XPrint version ISSN 0009-7411

Abstract

PEREZ-ARAGON, Beatriz J. et al. Steam roller maneuver in pneumatic retinopexy. Does it work?. Cir. cir. [online]. 2019, vol.87, n.5, pp.496-500.  Epub Nov 29, 2021. ISSN 2444-054X.  https://doi.org/10.24875/ciru.18000438.

Objective:

To identify the efficacy and safety of the steam-roller maneuver, in patients treated with pneumatic retinopexy.

Method:

Experimental, prospective, comparative, longitudinal study in patients with retinal detachment, treated with pneumatic retinopexy. Patients were assigned to one of two groups: without steam roller maneuver (group 1) or with it (group 2). The proportions of single-intervention anatomical success, visual improvement, anatomical success with reintervention, and adverse events were compared between groups (chi squared); preoperative and postoperative visual acuity in logMAR was compared within groups (Wilcoxon's t).

Results:

40 eyes were evaluated (mean age 55.9 ± 13.3 years); 15 were assigned to group 1, 25 to group 2. The proportions of single-intervention anatomical success, visual improvement, anatomical success with reintervention, and adverse events did not differ between groups (p > 0.05). At the end of follow up, visual acuity improved in both groups; however, it only improved in group 2, in eyes with single intervention anatomical success (mean log MAR before surgery 1.72 ± 1.64; after surgery 0.61 ± 0.61; p = 0.008).

Conclusions:

The steam roller maneuver is efficient for improving visual acuity in patients with pneumatic retinopexy, who achieve single intervention anatomical success; furthermore, the maneuver does not impair prognosis in eyes that require reintervention.

Keywords : Pneumatic retinopexy; Retinal detachment; Retinopexy; Steam-roller maneuver.