versión impresa ISSN 1870-249X

Resumen

CARRILLO-CEDILLO, E. G.; HARO-VAZQUEZ, M. P.; DIAZ TRUJILLO, G. C.  y  CANIZARES-MACIAS, M. P.. Plackett-Burman Factorial Design for the Optimization of a Spectrophotometric Flow Injection Method for Phenol Determination in Tap and Bottled Water Using 4-Aminoantipyrine. J. Mex. Chem. Soc [online]. 2014, vol.58, n.2, pp.99-105. ISSN 1870-249X.

Plackett-Burman and Quarter fraction 25-2 factorial designs were applied to evaluate a spectrophotometric flow injection method in order to determine phenol in water by using 4-aminoantipyrine (4-AAP) as derivatizing reagent. With a minimum number of experiments, the designs enabled the best conditions for phenol analysis: 80 cm and 180 cm reactors; flow-rates being: NH3 1.0 mL min-1; 4-AAP 0.35 mL min-1 and K3[Fe(CN)6] 0.35 mL min-1, [NH3] 0.064 mol L-1, [4-AAP] 9.84 × 10-3 mol L-1, [K3[Fe(CN)6]] 0.02 mol L-1, and an injection volume of 200 µL. With the optimized method it was possible to increase the lineal range from 0.3 µg mL-1 to 30 µg mL-1 and also to quantify the maximum allowable phenol concentration in water in comparison with other standard and flow injection methods whose lineal range are from 0.5 µg mL-1 to 20 µg mL-1 and from 0.5 µg mL-1 to 16 µg mL-1, respectively. The detection limit was of 0.13 µg mL-1 and the regression coefficient was of 0.9999, making possible a throughput of 36 determinations an hour with a minimum consume of reagent. With the proposed method, a distillation step was not necessary to remove sulfates but, when the sulfate:phenol ratio was higher than 83, the analytical signal for phenol increased 8%, but hypochlorite interfered with the signal when the hypochlorite:phenol ratio was higher than 1.

Palabras llave : Plackett-Burman factorial design; phenol; 4-aminoantipyrine; water; flow injection; spectrophotometry.