SciELO - Scientific Electronic Library Online

 
vol.20 número4Correlación histológica de expresión de marcadores Ki-67 y ciclina D1 presentes en carcinomas de células escamosas en cavidad oralEfectividad de la terapia con ácido tricloroacético en el tratamiento de lesiones en la hiperplasia epitelial focal índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Revista odontológica mexicana

versión impresa ISSN 1870-199X

Resumen

MIGUELENA MURO, Karla Eugenia; GUERRERO IBARRA, Jorge; GARCILAZO GOMEZ, Alfredo  y  RIOS SZALAY, Enrique. Resistance to displacement analysis of two resin cements in intra-root dentin. Rev. Odont. Mex [online]. 2016, vol.20, n.4, pp.238-242. ISSN 1870-199X.  https://doi.org/10.1016/j.rodmex.2016.11.003.

Abstract:

Several factors must be taken into account when cementing an endodontic post reinforced with fiberglass, among them we can mention selection of the cementing agent. Market available cements differ with respect to application mode, working time, polymerization and chemical composition. It is therefore necessary to count with sufficient knowledge of all their characteristics and behavior, not only from the clinical approach, but also in the laboratory. The evolution of resin cements is nowadays geared to technique simplificatión so as to decrease time and margin of error during clinical process. Moreover, previous studies have demonstrated that these changes have decreased adhesion force to dentin.

Objective:

The purpose of the present study was to observe the behavior of two resin cementing agents, assessing their adhesion strength in intra-root dentin: the BisCem®, Bisco Inc. system, formed by a dual selfadhesive cement, and the ParaCore® Automix (Coltene/Whaledent) system which is a dual cement system requiring a chemical curing self-conditioning agent and dentin adhesives (ParaBond® Coltene Whaledent).

Material and methods:

Thirty six single rooted teeth we encapsulated in acrylic and worn down until reaching intra-root dentin. Following manufacturer´s instructions, 18 samples were executed for each cement, and then in a universal testing device they were subjected to shearing tests (guillotine test) at a speed of 1 mm per minute.

Results:

It was observed that BisCem® exhibited lesser adhesion force than ParaCore® Automix. After statistically analyzing outcome by means of a «T» Student test, results revealed significant difference between both cements.

Conclusion:

ParaCore® Automix, requiring previous dentin conditioning (ParaBond®), exhibited greater adhesion force.

Palabras llave : Resin cements; self-adhesive cements; self-conditioning cements; resistance to displacement.

        · resumen en Español     · texto en Español | Inglés     · Español ( pdf ) | Inglés ( pdf )