SciELO - Scientific Electronic Library Online

 
vol.87 número1Anomalía de Ebstein «like» en doble entrada ventricular. Una rara asociación índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Archivos de cardiología de México

versión On-line ISSN 1665-1731versión impresa ISSN 1405-9940

Resumen

BECERRA-LUNA, Brayans; MARTINEZ-MEMIJE, Raúl; CARTAS-ROSADO, Raúl  y  INFANTE-VAZQUEZ, Oscar. Increase in the effectiveness of identifying peaks and feet of the photoplethysmographic pulse to be reconstructed it using adaptive filtering. Arch. Cardiol. Méx. [online]. 2017, vol.87, n.1, pp.61-71. ISSN 1665-1731.  https://doi.org/10.1016/j.acmx.2016.10.005.

Objective:

To improve the identification of peaks and feet in photoplethysmographic (PPG) pulses deformed by myokinetic noise, through the implementation of a modified fingertip and applying adaptive filtering.

Method:

PPG signals were recordedfrom 10 healthy volunteers using two photoplethysmography systems placed on the index finger of each hand. Recordings lasted three minutes andwere done as follows: during the first minute, both handswere at rest, and for the lasting two minutes only the left hand was allowed to make quasi-periodicmovementsin order to add myokinetic noise. Two methodologies were employed to process the signals off-line. One consisted on using an adaptive filter based onthe Least Mean Square (LMS) algorithm, and the other includeda preprocessing stage in addition to the same LMS filter. Both filtering methods were compared and the one with the lowest error was chosen to assess the improvement in the identification of peaks and feet from PPG pulses.

Results:

Average percentage errorsobtained wereof 22.94% with the first filtering methodology, and 3.72% withthe second one. On identifying peaks and feet from PPG pulsesbefore filtering, error percentages obtained were of 24.26% and 48.39%, respectively, and once filtered error percentageslowered to 2.02% for peaks and 3.77% for feet.

Conclusions:

The attenuation of myokinetic noise in PPG pulses through LMS filtering, plusa preprocessing stage, allows increasingthe effectiveness onthe identification of peaks and feet from PPG pulses, which are of great importance for medical assessment.

Palabras llave : Least mean square algorithm; Photoplethysmographic pulse signal; Accelerometer; Adaptive filters; Motion artifacts.

        · resumen en Español     · texto en Español     · Español ( pdf )