vol.78 número3Comparación de frecuencia de factores de riesgo cardiovascular tradicionales en mujeres con distinto nivel educativoLa cirugía de revascularización por toracotomía izquierda sin circulación extracorpórea, es una alternativa viable en la re-operación de puentes coronarios índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos de cardiología de México

versão On-line ISSN 1665-1731versão impressa ISSN 1405-9940

Resumo

GAMBOA, Ricardo et al. Pulsatile Fontan: Transcatheter closure of patent pulmonary artery: Follow up mid-term. Arch. Cardiol. Méx. [online]. 2008, vol.78, n.3, pp.293-298. ISSN 1665-1731.

Objective: We report the percutaneous closure of the pulmonary artery with residual shunt in patients with Fontan type circuit. Method: Patients aged 9 and 11 years, with SaO2 of 88 and 96%, respectively. One of them coursing with headaches and functional class II. Both patients with total cavopulmonary anastomosis and fenestrated extracardiac conduit and permeable pulmonary artery (pulsatile Fontan). An Amplatzer duct-occluder device was implanted in the pulmonary artery entering from the femoral vein. Follow-up by means of clinical examination, imaging, and catetherization was pursued. Results: Case 1, patency fenestration, Qp/Qs: 0.7/1. Case 2, closed fenestration, Qp/Qs; 1.3/1. We obtained immediate occlusion with 6/4 and 8/6 devices, respectively; pressure recordings revealed modification of the arterial morphology to biphasic; pulmonary pressure dropped 2 mm Hg in the first patient, without alteration in the second case; no changes in SaO2 were registered. Time of fluoroscopy was 57 and 45 minutes, respectively. Follow-up was maintained for 2.8 and 2.3 years, respectively. In patient 1, headaches disappeared and the fenestration was occluded with an Amplatzer septal-occluder one year later, raising SaO2 to 96%; no complications occurred nor was recanalization of the pulmonary artery needed in either case. Conclusions: Percutaneous occlusion of patent pulmonary artery in patients with Fontan type circuit is a feasible and effective procedure, and avoids overload of the single ventricle.

Palavras-chave : Catheterization; Fontan-type circuit; Occluder device.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 